• Title/Summary/Keyword: $Moir\acute{e}$

Search Result 52, Processing Time 0.035 seconds

A Study on the Small Disturbance Measurement of Liquid Film Thickness by $Moir\acute{e}$ Fringe ($Moir\acute{e}$ Fringe에 의한 액막 두께 미소 변위 측정 연구)

  • Jeon, H.S.;Kim, K.H.
    • Journal of ILASS-Korea
    • /
    • v.2 no.4
    • /
    • pp.29-35
    • /
    • 1997
  • Liquid film thickness is measured by $moir\acute{e}$ topography which monitored liquid surface. $Moir\acute{e}$ fringe measurement techniques share the inherent simplicity found in optical interferometric techniques have the advantage of use over a greater range of displacement. $Moir\acute{e}$ fringe are the geometric interference patterns observed when two dense line grating are superposed. Light transmitted through a fixed line grating is deviated by the liquid film surface, producing a distored image of the grating. The $moir\acute{e}$ fringe produced by projection of this optically distored grating onto a second stationary grating permit visualization of the liquid surface and measurement of the liquid film thickness. This study measured the small amplitude of liquid film thickness to the $moir\acute{e}$ fringe pattern produced when spherical metal was dropped glycerin put)1 And the measurement of liquid film thickness flowing down an inclined plate are required to calculate the liquid slope in a position.

  • PDF

3-D Reconstruction of Human Face Using the Derivative Moiré Topography

  • Bae, Yoon Jae;Ha, Byeong Wan;Park, Ji An;Cho, Choon Sik
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.500-506
    • /
    • 2014
  • A new 3-D reconstruction algorithm for the human face is proposed using the derivative Moir$\acute{e}$ topography which ensures fast and robust reconstruction even for rough surfaces. The Moir$\acute{e}$ interference fringe pattern is initially obtained through the projection Moir$\acute{e}$ topography based on phase shifting, and then differentiated to provide a full unwrapped phase map for a human face. $2{\pi}$ ambiguity, which has been a chronically unsolved problem with Moir$\acute{e}$ topography, is successfully surmounted by differentiating the Moir$\acute{e}$ fringe patterns both in x- and y-directions when the object is located in the x-y plane. A real human face is used for verifying the proposed derivative Moir$\acute{e}$ topography. A human face of 4 different phase-shifted images taken in the fixed plane is almost fully reconstructed in 3-D format in 0.1 mm lateral resolution.

Design of Moir${\acute{e}}$- and Starburst-Free Metal Meshes for Touch Screen Panels (모아레, 스타버스트 현상이 없는 터치스크린 패널용 메탈 메쉬 설계)

  • Shin, Dong-Kyun;Park, Jong-Woon;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.1
    • /
    • pp.83-90
    • /
    • 2014
  • Using a ray tracing simulation, we have investigated the moir${\acute{e}}$ and starburst phenomena of touch screen panels (TSPs) based on opaque metallic grids (square, hexagonal, and random grids). It is demonstrated that employing a random metal mesh is the most effective way to suppress the moir${\acute{e}}$ and starburst phenomena at the same time. At high crossing angles between metal mesh of TSPs and black matrix (BM) of displays, however, a random metal mesh brings in stronger moir${\acute{e}}$ phenomenon than a square metal mesh due to point defects. Though the square metal mesh suppresses the moir${\acute{e}}$ effect substantially at high crossing angles, yet it results in the strongest starburst patterns. We have also provided the simulation scheme that can capture the moir${\acute{e}}$ and starburst patterns observed experimentally and useful design guidelines for metal grids.

Moire Reduction in Digital Still Camera by Using Inflection Point in Frequency Domain (주파수 도메인의 변곡점을 이용한 디지털 카메라의 moire 제거 방법)

  • Kim, Dae-Chul;Kyung, Wang-Jun;Lee, Cheol-Hee;Ha, Yeong-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.152-157
    • /
    • 2014
  • Digital still camera generally uses optical low-pass filter(OLPF) to enhance its image quality because it removes high spatial frequencies causing aliasing. However, the use of OLPF causes some loss of detail. On the other hand, when image are captured by using no OLPF, the moir$\acute{e}$ is generally existed in high spatial frequency region of an image. Therefore, in this paper, moir$\acute{e}$ reduction method in case of using no OLPF is suggested. To detect the moir$\acute{e}$, spatial frequency response(SFR) of camera was firstly analyzed by using ISO 12233 resolution chart. Then, moir$\acute{e}$ region is detected by using the patterns that are related to the SFR of camera. next, this region is analysed in the frequency domain. Then, the moir$\acute{e}$ is reduced by removing its frequency component, which represents inflection point between high frequency and DC components. Through the experimental results, it is shown that the proposed method can achieve moir$\acute{e}$ reduction with preserving the detail.

Study on a moir$\acute{e}$ Artifact in the Use of Carbon Interspaced Antiscatter Grids for Digital Radiography (탄소 중간물질 그리드를 사용한 DR system에서의 moir$\acute{e}$ artifact에 관한 연구)

  • Lee, Sung-Ju;Cho, Hyo-Sung;Choi, Sung-Il;Cho, Hee-Moon;Oh, Ji-Eun;Lee, So-Young;Park, Yeon-Ok;Lee, Min-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.4
    • /
    • pp.5-9
    • /
    • 2008
  • Antiscatter grids are widely used in radiography to remove scattered X-rays and thus improve the image contrast. However, the use of grids makes moir$\acute{e}$ artifact in the digital image, and this can be a critical reason for a mistaken diagnosis. In this paper, we examined that moire artifacts are how to relate with grid frequency, pixel pitch and grid rotation angle. To experiment we prepared 6 grids having different line frequencies (4.0 to 8.5lines/mm) and tested with a DR imager having a $139{\mu}m{\times}139{\mu}m$ pixel size. In the result of this experiment, we could get data about moir$\acute{e}$ artifact that could be make solution to remove the line artifact for the successful use of the grid in digital radiography. The acquired data and theory through this experiment, are expected to make contribution to the elimination of moir$\acute{e}$ artifact in the DR system.

  • PDF

Discrimination of Spinal Deformity Employing Discriminant Analysis on the $Moir\acute{e}$ Images

  • Kim, Hyoung-Seop;Ishikawa, Seiji;Otsuka, Yoshinori;Shimizu, Hisashi;Nakada, Yasuhiro;Shinomiya, Takashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1990-1993
    • /
    • 2003
  • In this paper, we propose a technique for automatic spinal deformity detection from $moir\acute{e}$ topographic images. Normally the $moir\acute{e}$ stripes show symmetry as a human body is almost symmetric. According to the progress of the deformity of a spine, asymmetry becomes larger. Numerical representation of the degree of asymmetry is therefore useful in evaluating the deformity. First, displacement of local centroids and difference of gray values are evaluated statistically between the left- and the right-hand side regions of the $moir\acute{e}$ images with respect to the extracted middle line. We classify the moire images into two categories i.e., normal and abnormal cases from the features, employing discriminant analysis. An experiment was performed employing 1,200 $moir\acute{e}$ images and 85% of the images were classified correctly.

  • PDF

A Study on the In-plane Motion Measurement of Microstructure using $Moir{\acute{e}}$ Pattern ($Moir{\acute{e}}$ 무늬를 이용한 미세 구조물의 평면 움직임 측정에 관한 연구)

  • You, Bong-An;Lee, Byoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.659-661
    • /
    • 1997
  • An in-plane motion measurement method using $moir{\acute{e}}$ patterns by linear-gratings and cross-gratings, which can be used as micro inertial sensors, micro actuators, and micromachined scanning microscopes is demonstrated. A simple digital image processing method that calculates and analyzes the motion of microstructure from $moir{\acute{e}}$ patterns was developed. And using several grating structures fabricated by surface micromachining, we formed $moir{\acute{e}}$ patterns and analyzed the motion of microstructure.

  • PDF

A Study on 3-D Shape Measurement and Application by using Digital Projection $Moir\acute{e}$ ( I ) (디지털 영사식 무아레를 이용한 3차원 형상 측정과 응용에 관한 연구( I ))

  • Ryu Weon-Jae;Rho Hyung-Min;Lee Dong-Hwan;Kang Young-June
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.88-93
    • /
    • 2005
  • $Moir\acute{e}$ topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by $Moir\acute{e}$ topography has been required, since the method was frequently applied to the engineering and medical fields. The 3-D measurement using projection $Moir\acute{e}$ topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection $Moir\acute{e}$ topography was tested to measuring object with $2\pi-ambiguity$ problems. The experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi-ambiguity$ problems can be effectively overcome so as to treat large step discontinuities in measured objects.

Two-Wavelength Phase-Shifting Projection $Moir\acute{e}$ Topography for Measurement of Three-Dimensional Profiles with High Step Discontinuities (고단차 불연속 형상의 3차원 측정을 위한 이중파장 위상천이 영사식 무아레)

  • Kim, Seung-Woo;Oh, Jung-Taek;Jung, Moon-Sik;Choi, Yi-Bae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.7 s.166
    • /
    • pp.1129-1138
    • /
    • 1999
  • [$Moir\acute{e}$] technique is now being extensively investigated as a fast non-contact means of three-dimensional profile measurement especially for reverse engineering. One problem with $moir\acute{e}$ technique is so called $2\pi$-ambiguity problem that limits the maximum step height difference between two neighboring sampling points to be less than half the equivalent wavelength of $moir\acute{e}$ fringes. In this investigation, a new two-wavelength scheme of projection $moir\acute{e}$ topography is proposed and tested to cope with the $2\pi$-ambiguity problem. Experimental results are discussed to assess the new method in measuring large objects with high step discontinuities.

Nano-level High Sensitivity Measurement Using Microscopic Moiré Interferometry (마이크로 무아레 간섭계를 이용한 초정밀 변형 측정)

  • Joo, Jin-Won;Kim, Han-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.2
    • /
    • pp.186-193
    • /
    • 2008
  • [ $Moir{\acute{e}}$ ] interferometry is an optical method, providing whole field contour maps of in-plane displacements with high resolution. The demand for enhanced sensitivity in displacement measurements leads to the technique of microscopic $moir{\acute{e}}$ interferometry. The method is an extension of the $moir{\acute{e}}$ interferometry, and employs an optical microscope for the required spatial resolution. In this paper, the sensitivity of $moir{\acute{e}}$ interferometry is enhanced by an order of magnitude using an immersion interferometry and the optical/digital fringe multiplication(O/DFM) method. In fringe patterns, the contour interval represents the displacement of 52 nm per fringe order. In order to estimate the reliability and the applicability of the optical system implemented, the measurements of rigid body displacements of grating mold and the coefficient of thermal expansion(CTE) for an aluminium block are performed. The system developed is applied to the measurement of thermal deformation in a flip chip plastic ball grid array package.