Chromosomal Integration에 의해 제조한 Bacillus clausii C5 유래의 alkaline protease의 세제 첨가제 응용성 (Feasibility as a Laundry Detergent Additive of an Alkaline Protease from Bacillus clausii C5 Transformed by Chromosomal Integration)

  • 주한승;최장원
    • KSBB Journal
    • /
    • 제27권6호
    • /
    • pp.352-360
    • /
    • 2012
  • Bacillus clausii I-52 which produced SDS- and $H_2O_2$-tolerant extracellular alkaline protease (BCAP) was isolated from heavily polluted tidal mud flat of West Sea in Incheon, Korea and stable strain (transformant C5) of B. clausii I-52 harboring another copy of BCAP gene in the chromosome was developed using the chromosome integration vector, pHPS9-fuBCAP. When investigated the production of BCAP using B. clausii transformant C5 through pilot-scale submerged fermentation (500 L) at $37^{\circ}C$ for 30 h with an aeration rate of 1 vvm and agitation rate of 250 rpm, protease yield of approximately 105,700 U/mL was achieved using an optimized medium (soybean meal 2%, wheat flour 1%, sodium citrate 0.5%, $K_2HPO_4$ 0.4%, $Na_2HPO_4$ 0.1%, NaCl 0.4%, $MgSO_4{\cdot}7H_2O$ 0.01%, $FeSO_4{\cdot}7H_2O$ 0.05%, liquid maltose 2.5%, $Na_2CO_3$ 0.6%). The enzyme stability of BCAP was increased by addition of polyols (10%, v/v) and also, the stabilities of BCAP towards not only the thermal-induced inactivation at $50^{\circ}C$ but also the SDS and $H_2O_2$-induced inactivation at $50^{\circ}C$ were enhanced. Among the polyols examined, the best result was obtained with propylene glycol (10%, v/v). The BCAP supplemented with propylene glycol exhibited extreme stability against not only the detergent components such as ${\alpha}$-orephin sulfonate (AOS) and zeolite but also the commercial detergent preparations. The granulized enzyme of BCAP was prepared with approximately 1,310,000 U/g of granule. Wash performance analysis using EMPA test fabrics revealed that BCAP granule exhibited high efficiency for removal of protein stains in the presence of anionic surfactants as well as bleaching agents. When compared to Savinase 6T$^{(R)}$ and Everlase 6T$^{(R)}$ manufactured by Novozymes, BCAP under this study probably showed similar or higher efficiency for the removal of protein stains. These results suggest that the alkaline protease produced from B. clausii transformant C5 showing high stability against detergents and high wash performance has significant potential and a promising candidate for use as a detergent additive.

한국산 녹두와 중국산 녹두에 있어서 Lectin의 생화학적 특성 비교 (Comparison of Biochemical Characterization of Korean and Chinese Mung Bean Lectin)

  • 노광수
    • 생명과학회지
    • /
    • 제24권6호
    • /
    • pp.603-611
    • /
    • 2014
  • 한국산과 중국산 녹두 종자에서 0.15 M NaCl/0.1 M sodium phosphate buffer (pH7.0)에 의한 추출, $(NH_4)_2SO_4$ 침전, 최종적으로 Sephadex G-100을 이용한 affinity chromatography에 의해 lectin을 분리한 다음, 이들의 생화학적 특성을 조사, 비교하였다. 사람의 적혈구는 trypsin의 처리 유무와 상관없이 응집반응이 일어나지 않으며, 토끼의 적혈구에서는 trypsin을 처리한 경우에만 응집반응이 일어났다. 두 녹두 종자 lectin의 분자량은 SDS-PAGE를 통해 54 kDa와 28 kDa로 확인되었다. 한국산 녹두 종자 lectin의 최적 반응 온도는 $60^{\circ}C$이며, 중국산 녹두 종자 lectin의 경우는 $50^{\circ}C$로 나타났다. 종자 lectin이 열에 가장 안정한 온도는 한국산의 경우는 $50^{\circ}C$이며, 중국산의 경우 $40-50^{\circ}C$로 밝혀졌다. 한국산 녹두 종자 lectin은 pH 3.2에서 가장 높은 활성을 보였으며, 중국산 녹두 종자 lectin은 pH 6.2에서 가장 높은 활성을 보였다. 변성제를 처리했을 때, thiourea와 guanidine-HCl과는 혈액 응집이 일어나지 않아 변성작용이 일어남을 알 수 있었고, urea와는 혈액 응집이 일어나지 않아 변성작용이 일어나지 않음을 알 수 있었다. D-glucose외 6가지의 탄수화물에 대한 특이성이 나타나지 않았다. 또한 두 녹두 종자의 lectin은 $Ca^{2+}$, $Co^{2+}$, $Cu^{2+}$, $Cu^{2+}$, $Mg^{2+}$$Mn^{2+}$ 등의 금속이온에 대한 특이성이 없었다.

우리나라 산림토양의 산성화 민감도평가와 그에 따른 토양 이화학적 특성 비교분석 (Comparison of Soil Physicochemical Properties According to the Sensitivity of Forest Soil to Acidification in the Republic of Korea)

  • 이아림;구남인
    • 한국산림과학회지
    • /
    • 제109권2호
    • /
    • pp.157-168
    • /
    • 2020
  • 본 연구는 국내 산림토양을 대상으로 새로운 민감도 평가기법을 활용하여 산림토양 산성화 민감도를 평가하여 3가지 등급으로 구분하고, 각 민감도 그룹별 산성화 정도 및 토양 이화학적 특성을 비교·분석하여 산림토양의 질적 현황을 파악하려는 목적으로 수행되었다. 공시토양은 국립산림과학원에서 설치한 산성화 모니터링 고정조사지에서 채취하여 이화학적 특성 분석에 활용하였으며, 산림토양 산성화 민감도는 토양 pHH2O, 양이온치환용량(Cation exchange capacity, CEC), 염기포화도(Base saturation, BS)를 활용하여 평가하였다: '양호'(pH≧4.2, CEC≧15cmol/kg, BS≧15%), '주의'(1~2개 지표 '양호'등급 기준미달), '심각'(3가지 지표 모두 미달). 전체 공시토양의 약 19%가 '양호'등급으로 분류되었으며, 66%와 15%는 각각 '주의'와 '심각'등급으로 분류되었다. 양호등급의 경우 양분의 상태(치환성 양이온, 치환성 양이온/전질소 몰비), CEC, BS 등 대부분의 토양 인자들이 수목 생육에 적합한 수준인 것으로 나타났다. 그러나 주의 및 심각 등급으로 갈수록 토양의 양분, CEC, BS 등의 인자들이 양호등급의 토양보다 유의하게 낮았으며, K+ 등의 필수 영양소가 결핍되는 현상이 나타났다. 또한, 독성물질인 치환성 알루미늄의 농도가 양호등급에 비해 2배 이상 높고, 치환성 알루미늄의 독성발현 가능성을 평가하는 Ca/Al지표가 0.6이하로 나타나 산성화로 인해 수목 생육이 저해될 가능성이 높은 것으로 나타났다. 이러한 현상은 토양 산성화로 인한 양분의 용탈 및 치환성알루미늄의 농도 등의 차이 때문으로 사료되며, 주의 및 심각등급의 토양은 산성화로 인한 토양의 질적 저하가 진행되고 있는 것으로 판단된다. 그러므로 산성화로 인한 산림쇠퇴를 방지하기 위해서는 pH교정을 통해 치환성 알루미늄의 유효도를 감소시키고 부족해진 양분을 보충하는 등 토양의 이화학적 환경회복이 필요할 것으로 판단된다.

장기간 (1990 ~ 2012) 측정자료를 이용한 용인-수원지역에서의 PM2.5의 화학적 특성연구 및 헤이즈와 황사 현상 시 화학성분별 질량분율표의 개발 (Study on Chemical Characterization of PM2.5 based on Long-term Database (1990 ~ 2012) and Development of Chemical Species Profiles During Haze Days and Asian Dust Days in Yongin-Suwon Area)

  • 임효지;이태정;김동술
    • 한국대기환경학회지
    • /
    • 제31권3호
    • /
    • pp.223-238
    • /
    • 2015
  • The $PM_{2.1}$ was collected by LVCI (low volume cascade impactor) during Group-A Period (September 1990 to December 2012) and the $PM_{2.5}$ was collected by HVAS (high volume air sampler) during Group-B Period (September 2009 to April 2012) at Kyung Hee University, Global Campus located on the boarder of Yongin and Suwon. The 8 water-soluble ions ($Na^+$, $NH_4{^+}$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, $ NO_3{^-}$, and $SO_4{^{2-}}$) were analyzed by IC, and the 14 inorganic elements (Al, Mn, Si, Fe, Cu, Pb, Cr, Ni, V, Cd, Ba, Zn, Ti, Ag) were analyzed by XRF and ICP-AES after performing proper pre-treatments of each sample filter. The average total mass fractions of $SO_4{^{2-}}$, $NO_3{^-}$, and $NH_4{^+}$+ to $PM_{2.5}$ samples during Group-B Period were 0.39 in normal days, 0.44 in haze days, and 0.27 in Asian dust days, respectively; however, the average total mass fractions of Al, Fe, and Si to $PM_{2.5}$ mass were 0.043 in normal days, 0.021 in haze days, and 0.036 in Asian dust days, respectively. Especially the concentration of Pb was significantly decreased during Group-B Period rather than during Group-A Period, while Cr and Ni was increased during Group-B Period. In this study, we intensively compared the annual and seasonal patterns of major chemical species among normal days, haze days, and Asian dust days. Further we developed mass fraction profiles by collecting episode cases of haze days and Asian dust days, which were consisting of 22 chemical species. Those profiles are considered to be useful when applying various receptor models and establishing air quality management plans near future.

토양(土壤)에서 분리(分離)한 Streptomyces sp. s-45의 효소학적(酵素學的) 성질(性質)에 관한 연구(硏究) (Studies on the Enzymatical Properties of Streptomyces sp. S-45 Isolated from Soil)

  • 김영일;김용웅;김광식
    • 한국토양비료학회지
    • /
    • 제21권2호
    • /
    • pp.129-134
    • /
    • 1988
  • 토양(土壤)으로부터 분리(分離)한 Streptomyces sp. S-45 균주(菌株)의 효소학적(酵素學的) 성질(性質)을 검토(檢討)한 결과(結果)는 다음과 같다. 1. 분리균(分離菌) Streptomyces sp. S-45의 Chitinase activity는 $3.01({\mu}/m{\ell})$이고 ${\beta}$-1.3-Glucanase activity는 $2.49({\mu}/m{\ell})$이었다. 2. 탄소원(炭素原)으로서 Colloidal chitin 0.7%, Glucose 0.3%, 질소원(窒素原)으로서 Asparagine 0.5%, Peptone 0.2% 존재(存在)가 효소생산(酵素生産)에 효과적(效果的)이었다. 3. 최적(最適) 효소생성(酵素生成) 조건(條件)으로 pH 7.0, $30^{\circ}C$에서 6일간(日間) 진탕배양시(培養時) 최고(最高)의 효소생성(酵素生成)을 나타내었다. 4. 효소(酵素)의 활성(活性)에 미치는 최적(最適) 작용조건(作用條件)은 pH 6.5~7.0, 온도(溫度)는 $45{\sim}50^{\circ}C$였다. 5. 본(本) 효소(酵素)는 pH6.0~7.0에서 안정성(安定性)이 가장 높았고, $80^{\circ}C$로 10분(分) 처리시(處理時) Chitinase는 10%, ${\beta}$-1.3-Glucanase는 12%로 잔존활성(殘存活性)이 감소(減少)하였다. 6. 금속(金屬)이온에 대한 효소(酵素)의 영향(影響)은 $Co^{{+}{+}}$, $Cu^{{+}{+}}$, $Mn^{{+}{+}}$, $Al^{{+}{+}{+}}$$10^{-2}M$$Sn^{{+}{+}}\;10^{-3}M$에서 활성(活性)이 증대(增大)하였고, $Ag^{{+}{+}}$, $Hg^{{+}{+}}$는 현저(顯著)한 저해작용을 하였다.

  • PDF

도시 및 농촌 일부지역의 강하분진과 여과액중의 이온농도 (Dustfalls and Various Ion Concentrations in Their Filtrates in an Urban and in a Rural Districts)

  • 홍연표
    • Journal of Preventive Medicine and Public Health
    • /
    • 제18권1호
    • /
    • pp.59-71
    • /
    • 1985
  • During a period from February 1st to November 30th in 1983, measurements were made twice a month on dustfalls and concentrations of various cations ana anions in their filtrates in an urban (Heuksuk-dong, Seoul) and in a rural (Ansung) districts. Standard British Deposit Gauge method was applied for collection of dustfalls and ion chromatographic method using Ion Chromatograph 10 (Dionex, U.S.A.) for determination of cation and anion concentrations. The results obtained were as follows: 1. Annual mean values of dustfalls were $8.30{\pm}5.09tons/km^2/month$ in an urban and $6.20{\pm}0.82tons/km^2/month$ in a rural districts. And annual mean values of pH of filtrates of the collected samples were $5.3{\pm}0.76$ in an urban and $6.0{\pm}0.82$ in a rural districts. 2. Annual mean concentrations of common cations and anions in their filtrates were as follows: urban rural (unit: ppm) $$Na^{+}\;1.7{\pm}1.30\;1.9{\pm}1.86$$ $$NH^{+}_{4}\;2.4{\pm}1.60\;1.3{\pm}1.59$$ $$K^{+}\;0.7{\pm}0.47\;1.5{\pm}3.79$$ $$Ca^{++}\;5.3{\pm}0.95\;3.4{\pm}2.58$$ $$Mg^{++}\;0.7{\pm}0.89\;0.5{\pm}0.83$$ $$Cl^{-}\;2.0{\pm}1.31\;4.0{\pm}2.35$$ $$NO^{-}_{3}\;4.0{\pm}2.35\;2.7{\pm}1.31$$ $$So^{--}_{4}\;16.9{\pm}17.40\;6.8{\pm}8.00$$ Some of anions such as $Br^{-},\;{PO_4}^{-3}\;and\;{NO_2}^{-}$ were scarecely detected and $F^{-}$ was measured at very low concentrations ranging from 0.1 to 0.5 ppm in Feb., Oct. and Nov. in an urban and in Feb. in a rural districts. 3. By two-way analysis of variance with 4 replications for dustfalls, pH and concentrations of various ion by district and month of a year, statistically significant differences were noted in dustfalls (p<0.01), pH (p<0.01) and concentrations of various ion (p<0.01) by month of a year, and in dustfalls (p<0.05) and concentrations of various ion such as ${NH_4}^{+},\;Ca^{++},\;{NO_{3}}^{-}\;and\;{SO_4}^{--}$ (p<0.01) by district. 4. There were statistically significant differences pH in Spring (Feb., Mar and Apr.) (p<0.01) and in ${SO_4}^{--}$ in Autumn (Aug., Sept., Oct. and Nov.) (p<0.05) between the two districts.

  • PDF

남극 장보고과학기지 인근에서 채취한 눈시료 내의 주요 이온성분들의 고해상도 계절변동성 연구 (A Study on High-Resolution Seasonal Variations of Major Ionic Species in Recent Snow Near the Antarctic Jang Bogo Station)

  • 곽호제;강정호;홍상범;이정훈;장채원;허순도;홍성민
    • Ocean and Polar Research
    • /
    • 제37권2호
    • /
    • pp.127-140
    • /
    • 2015
  • A continuous series of 60 snow samples was collected at a 2.5-cm interval from a 1.5-m snow pit at a site on the Styx Glacier Plateau in Victoria Land, Antarctica, during the 2011/2012 austral summer season. Various chemical components (${\delta}D$, ${\delta}^{18}O$, $Na^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, $SO_4{^2-}$, $NO_3{^-}$, $F^-$, $CH_3SO_3{^-}$, $CH_3CO_2{^-}$ and $HCO_2{^-}$) were determined to understand the highly resolved seasonal variations of these species in the coastal atmosphere near the Antarctic Jang Bogo station. Based on vertical profiles of ${\delta}^{18}O$, $NO_3{^-}$and MSA, which showed prominent seasonal changes in concentrations, the snow samples were dated to cover the time period from 2009 austral winter to 2012 austral summer with a mean accumulation rate of $226kgH_2Om^{-2}yr^{-1}$. Our snow profiles show pronounced seasonal variations for all the measured chemical species with a different pattern between different species. The distinctive feature of the occurrence patterns of the seasonal variations is clearly linked to changes in the relative strength of contributions from various natural sources (sea salt spray, volcanoes, crust-derived dust, and marine biogenic activities) during different short-term periods. The results allow us to understand the transport pathways and input mechanisms for each species and provide valuable information that will be useful for investigating long-term (decades to century scale periods) climate and environmental changes that can be deduced from an ice core to be retrieved from the Styx Glacier Plateau in the near future.

Comparison of Chemical Compositions of Size-segregated Atmospheric Aerosols between Asian Dust and Non-Asian Dust Periods at Background Area of Korea

  • Kim, Won-Hyung;Song, Jung-Min;Ko, Hee-Jung;Kim, Jin Seog;Lee, Joung Hae;Kang, Chang-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권11호
    • /
    • pp.3651-3656
    • /
    • 2012
  • The size-segregated atmospheric aerosols have been collected at 1100 m site of Mt. Halla in Jeju, a background area in Korea, using 8-stage cascade impact air sampler during Asian dust and non-Asian dust storm periods. Their ionic and elemental species were analyzed, in order to examine the pollution characteristics and composition change between Asian dust and non-Asian dust periods. The major ionic species such as nss-$SO_4{^{2-}}$, $NH_4{^+}$, and $K^+$ were predominantly distributed in the fine particles (below $2.1{\mu}m$ diameter), and besides the $NO_3{^-}$ was distributed more in coarse particle fraction than fine particle. On the other hand, the typical soil and marine species i.e., nss-$Ca^{2+}$, $Na^+$, $Cl^-$, and $Mg^{2+}$, were mostly existed in the coarse particles (over $2.1{\mu}m$ diameter). As well in the elemental analysis of aerosols, the major soil-originated Al, Fe, Ca, and others showed prominently high concentrations in the coarse particle fraction, whereas the anthropogenic S and Pb were relatively high in the fine particle fraction. From the comparison of aerosol compositions between Asian dust and non-Asian dust periods, the concentrations of the soil-originated species such as nss-$Ca^{2+}$, Al, Ca, Fe, Ti, Mn, Ba, Sr have increased as 2.7-4.2 times during the Asian dust periods. Meanwhile the concentrations of nss-$SO_4{^{2-}}$ and $NO_3{^-}$ have increased as 1.4 and 2.0 times, and on the contrary $NH_4{^+}$ concentrations have a little bit decreased during the Asian dust periods. Especially the concentrations of both soil-originated ionic and elemental species increased noticeably in the coarse particle mode during the dust storm periods.

SEM-EDX 분석법에 의한 부산 S공업단지의 PM10과 PM2.5의 화학적 조성 및 발생원 추정 (Source Apportionment Study and Chemical Composition of PM10 and PM2.5 in the Industrial Complex of Busan City, Korea)

  • 김용석;최금찬;서정민
    • 한국환경과학회지
    • /
    • 제26권11호
    • /
    • pp.1297-1306
    • /
    • 2017
  • This study identified physical characteristics and aerosol particle sources of $PM_{10}$ and $PM_{2.5}$ in the industrial complex of Busan Metropolitan City, Korea. Samples of $PM_{10}$, $PM_{2.5}$ and also soil, were collected in several areas during the year of 2012 to investigate elemental composition. A URG cyclone sampler was used for collection. The samples were collected according to each experimental condition, and the analysis method of SEM-EDX was used to determine the concentration of each metallic element. The comparative analysis indicated that their mass concentration ranged from 1% to 3%. The elements in the industrial region that were above 10% were Si, Al, Fe, and Ca. Those below 5% were Na, Mg, and S. The remaining elements (1% of total mass) consisted of elements such as Ni, Co, Br and Pb. Finally, a statistical tool was applied to the elemental results to identify each source for the industrial region. From a principal components analysis (SPSS, Ver 20.0) performed to analyze the possible sources of $PM_{10}$ in the industrial region, five main factors were determined. Factor 1 (Si, Al), which accounted for 15.8% of the total variance, was mostly affected by soil and dust from manufacturing facilities nearby, Factors 2 (Cu, Ni), 3 (Zn, Pb), and 4 (Mn, Fe), which also accounted for some of variance, were mainly related to iron, non-ferrous metals, and other industrial manufacturing sources. Also, five factors determined to access possible sources of $PM_{2.5}$, Factor 1 (Na, S), accounted for 13.5% of the total variance and was affected by sea-salt particles and fuel incineration sources, and Factors 2 (Ti, Mn), 3 (Pb, Cl), 4 (K, Al) also explained significant proportions of the variance. Theses factors mean that the $PM_{2.5}$ emission sources may be considered as sources of incineration, and metals, and non-ferrous manufacturing industries.

북한산국립공원 내 초미세먼지 농도 및 화학적 특성 (Characterization of Aerosol Composition, Concentration, and Sources in Bukhansan National Park, Korea)

  • 강석원;강태원;박태현;박규태;이준홍;홍제우;홍진규;이재홍;이태형
    • 한국대기환경학회지
    • /
    • 제34권3호
    • /
    • pp.457-468
    • /
    • 2018
  • To improve understanding of the physico-chemical characteristics of aerosols in the national park and comparing the air pollution between national park and the urban area nearby national park, the aerosol characterization study was conducted in Bukhansan National Park, Seoul, from July through September 2017. Semi-continuous measurements of $PM_{2.5}$ using PILS (Particle Into Liquid System) coupled with IC (Ion Chromatography) and TOC (Total Organic Carbon) analyzer allowed quantification of concentrations of major ionic species($Cl^-$, $SO_4{^{2-}}$, $NO_3{^-}$, $Na^+$, $NH_4{^+}$, $K^+$, $Mg{^{2+}}$ and $Ca{^{2+}}$) and water soluble organic carbon (WSOC) with 30-minute time resolution. The total mass concentration of $PM_{2.5}$ was measured by T640 (Teledyne) with 5-minute time resolution. The black carbon (BC) and ozone were measured with a minute time resolution. The timeline of aerosol chemical compositions reveals a strong influence from urban area (Seoul) at the site in Bukhansan National Park. Inorganic aerosol composition was observed to be dominated by ammoniated sulfate at most times with ranging from $0.1{\sim}32.6{\mu}g/m^3$ (6.5~76.1% of total mass of $PM_{2.5}$). The concentration of ammonium nitrate, a potential indicator of the presence of local source, ranged from below detection limits to $20{\mu}g/m^3$ and was observed to be highest during times of maximum local urban (Seoul) impact. The total mass of $PM_{2.5}$ in Bukhansan National Park was observed to be 10~23% lower than the total mass of $PM_{2.5}$ in urban area (Gireum-dong and Bulgwang-dong, Seoul). In general, ozone concentration in Bukhansan National Park was observed to be similar or higher than urban sites in Seoul, suggesting additional biogenic VOCs with $NO_x$ from vehicle emission were to be precursors for ozone formation in Bukhansan National Park.