• Title/Summary/Keyword: $M_1$-index

Search Result 3,448, Processing Time 0.031 seconds

Correlation study between Obesity and Cardiovascular Risk Factors (비만과 심혈관 질환 위험인자와의 상관관계 분석 -건강검진 대상자를 중심으로-)

  • Cho, Tae-Young;Cho, Hyun-Chol;Hong, Seo-Young;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.4 no.1
    • /
    • pp.33-43
    • /
    • 2004
  • Background: Recently obesity has become a social problem in all over the world including Korea. It is known that obesity is closely related with cardiovascular disease. Many studies are carrying out in the relation between several obesity indices, such as body mass index(BMI), waist-circumference(WC), body fat percent and risk factors of cardiovascular disease. Objective: This study was done in order to investigate correlation of obesity and cardiovascular risk factors. Method: We gathered totally 138 subjects who have taken health screening test in university hospital. With the exception of 40 abnormal cases on current illness and laboratory study, 98 healthy cases were analysed. We divided the groups as normal, overweight, obese group according to body mass index $(22.9kg/m^2\;and\;below\;/\;23{\sim}24.9kg/m^2\;/\;25kg/m^2\;and\;above)$and investigated the relationship between obesity based on body mass index(BMI) and cardiovascular risk factors. And investigated the relationship between each cardiovascular risk factor and body mass index, waist-hip ratio, body fat percent. Results: With the exception of blood pressure, other lab data such as total cholesterol, triglycerid, glucose were significantly different between the three groups divided by body mass index$(22.9kg/m^2\;and\;below\;/\;23{\sim}24.9kg/m^2\;/\;25kg/m^2\;and\;above)$. And Correlation coefficient of cardiovascular risk factors with body mass index, waist-hip ratio, body fat precent were acquired. Conclusion: We have concluded that the body mass index and waist-hip ratio body fat precent were predictive factors cardiovascular disease.

  • PDF

SOME INEQUALITIES FOR THE HARMONIC TOPOLOGICAL INDEX

  • MILOVANOVIC, E.I.;MATEJIC, M.M.;MILOVANOVIC, I.Z.
    • Journal of applied mathematics & informatics
    • /
    • v.36 no.3_4
    • /
    • pp.307-315
    • /
    • 2018
  • Let G be a simple connected graph with n vertices and m edges, with a sequence of vertex degrees $d_1{\geq}d_2{\geq}{\cdots}{\geq}d_n$ > 0. A vertex-degree topological index, referred to as harmonic index, is defined as $H={\sum{_{i{\sim}j}}{\frac{2}{d_i+d_j}}$, where i ~ j denotes the adjacency of vertices i and j. Lower and upper bounds of the index H are obtained.

A study on the fabrication of Y-branch for optical power distribution and its coupling properties with optical fiber (광분배를 위한 Y-branch 제작과 광파이버와의 결합특성에 관한 연구)

  • 김상덕;박수봉;윤중현;이재규;김종빈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3277-3285
    • /
    • 1996
  • In this paper, w designed an opical power distribution device for application to an optical switching and an optical subscriber loop. We fabricated PSG thin film by LPCVD. Based on the measured index of fabricted thin film, rib-type waveguide was transformed to two-dimension by the effective index method and we simulated dispersion property to find asingle-mode condition. We found that the optimum design parameters of rib-type waveguide are:cladding layer of 3.mu.m, core layer of 3.mu.m, buffer layer of 10.mu.m, and core width of 4.mu.m. Each side of the guiding region was etched down to 4.mu.m to shape the core. We used these optimum parameters of the rib-type waveguide with branching angle of 0.5.deg. and simulted the Y-branch waveguide by the BPM simulation. Numerical loss in branching area was claculated to be 0.1581dB and equal to the total loss of the Y-branch. The loss of the fabricated Y-branch waveguide on PSG film ws 1.6dB at .lambda.=1.3.mu.m before annealing but was 1.2dB after annealing at 1000.deg. C for 10 minutes. Consequently, the loss of branching area from 3000.mu.m to 6000.mu.m in the z-direction was 0.8dB, and single-mode propagation was confirmed by measuring the near field pattern. For coupling the fabricated Y-branch waveguide with an optical fiber, we fabricated V-groove which was used as the upholder of optical fiber. An etching angle was 54.deg. and the width and depth of guiding groove was 150.mu.m, 70.mu.m, respectively. The optical fiber is inserted onto V-groove. Both the Y-branch and V-groove were connected through the index matching oil. Coupling loss after connecting Y-branch and the optical fiber on V-groove was 0.34dB and that after injecting index mateching oil was 0.14dB.

  • PDF

Descending Aorta Index and Pulmonary Index in Infants Comparison between Atrioventricular Septal Defects, At ial Septal Defects and Ventricular Septal Defects (심방실 중격 결손증에서의 하행대동맥, 폐동맥 지수)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.591-594
    • /
    • 1993
  • To clarify the apparent hypoplasia of the descending aorta in infants with atrioventricular septal defect[AVSD] patients, we reviewed the catheterization data and angiograms of 34 consecutive patients with AVSD less than 1 year of age who underwent repair at our institution since 1985. We compared them to 10 patients with Atrial Septal Defect[ASD] and 10 patients with Ventricular Septal Defect[VSD] who were matched for age, size and Qp/Qs. The Descending Aorta Index [DAI] of the AVSD group was not different from the VSD or ASD groups, [147.9$\pm$ 34.8 mm2/m2 versus 158.6$\pm$ 31.5 mm2/m2 and 153.2$\pm$ 43.1 mm2/m2].However, the Pulmonary Artery Index [PAI] of the AVSD group was significantly larger than the other groups [684.3$\pm$ 170.7 mm2/m2 versus 454.1$\pm$ 109.1 mm2/m2 and 534.9$\pm$ 148.4 mm2/m2][p<0.05], as was the ratio of PAI/DAI in the AVSD group [4.99$\pm$ 1.77 versus 2.89$\pm$ 0.81 and 3.6$\pm$ 0.92][p<0.05]. Despite similar Qp/Qs ratios, both the mean PA pressure and the Rp/Rs in the AVSD group was higher than the VSD and ASD groups: 43.1$\pm$ 15.6 mmHg versus 29$\pm$ 11.6 mmHg and 24$\pm$ 18.1 mmHg [p<0.05], and 0.27$\pm$ 0.22 versus 0.14$\pm$ 0.03 and 0.11$\pm$ 0.05 [p<0.05] respectively. The apparent hypoplasia of the descending aorta in infants with AVSD is an illusion created by the abnormally large pulmonary arteries, which are significantly larger than in patients with ASDs or VSDs.

  • PDF

A Study on the characteristics of the Double Refractive Index Fiber in the 1.55$mu extrm{m}$ (파장 1.55$mu extrm{m}$에서 이중굴절율 분포를 가진 광섬유의 특성에 관한 연구)

  • 최태일;이주형;최병하
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.14 no.5
    • /
    • pp.571-577
    • /
    • 1989
  • In this paper, the double-refractive index profile, which is generalized a trapezoidal index profile, is proposed to study the characteristics of a optical fiber in the wave length 1.55um. Being compared with a triangle profile, it has many advantages over an optimum core radius, the minimum refractive index difference and the change of chromati dispersion characteristics with wavelength. Though the value of a varies from 2 to infinite, the same results are approximately obtained. Therefore, in fabrication of a fiber, the step part of trapezoidal index profile can replace the profile of a-power refractive index. Because the refractive index presented in this paper varies with a, it can be applied to multiple cladding fiber or segmented core fiber. And it is expected that the characteristics of the fiber are obtained.

  • PDF

Iterative damage index method for structural health monitoring

  • You, Taesun;Gardoni, Paolo;Hurlebaus, Stefan
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.1
    • /
    • pp.89-110
    • /
    • 2014
  • Structural Health Monitoring (SHM) is an effective alternative to conventional inspections which are time-consuming and subjective. SHM can detect damage early and reduce maintenance cost and thereby help reduce the likelihood of catastrophic structural events to infrastructure such as bridges. After reviewing the Damage Index Method (DIM), an Iterative Damage Index Method (IDIM) is proposed to improve the accuracy of damage detection. These two damage detection techniques are compared based on damage on two structures, a simply supported beam and a pedestrian bridge. Compared to the traditional damage detection algorithm, the proposed IDIM is shown to be less arbitrary and more accurate.

On the Subsemigroups of a Finite Cyclic Semigroup

  • Dobbs, David Earl;Latham, Brett Kathleen
    • Kyungpook Mathematical Journal
    • /
    • v.54 no.4
    • /
    • pp.607-617
    • /
    • 2014
  • Let S = C(r,m), the finite cyclic semigroup with index r and period m. Each subsemigroup of S is cyclic if and only if either r = 1; r = 2; or r = 3 with m odd. For $r{\neq}1$, the maximum value of the minimum number of elements in a (minimal) generating set of a subsemigroup of S is 1 if r = 3 and m is odd; 2 if r = 3 and m is even; (r-1)/2 if r is odd and unequal to 3; and r/2 if r is even. The number of cyclic subsemigroups of S is $r-1+{\tau}(m)$. Formulas are also given for the number of 2-generated subsemigroups of S and the total number of subsemigroups of S. The minimal generating sets of subsemigroups of S are characterized, and the problem of counting them is analyzed.

Studies on the volatile compounds of Cnidium officinale (천궁(Cnidium officinale)의 향기성분)

  • 이재곤;권영주;장희진;김옥찬;박준영
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.16 no.1
    • /
    • pp.20-25
    • /
    • 1994
  • The volatile components were extracted from root of Cnidium officinale M. by SDE(Simultaneous steam distillation and extraction) apparatus and analyzed by GC/M.5 and GC retention index matching. The experimental results revealed the presence of over 22 volatile components. Major components were cnidilide (35.1%), neocnidilids (13.4%), ligustilide (23.2%). The essential oils were separated by silica gel column chromatography(Merck 70-230mesh), and 4 fractions among 12 fractions separated had a, good aroma character.

  • PDF

THE ZAGREB INDICES OF BIPARTITE GRAPHS WITH MORE EDGES

  • XU, KEXIANG;TANG, KECHAO;LIU, HONGSHUANG;WANG, JINLAN
    • Journal of applied mathematics & informatics
    • /
    • v.33 no.3_4
    • /
    • pp.365-377
    • /
    • 2015
  • For a (molecular) graph, the first and second Zagreb indices (M1 and M2) are two well-known topological indices, first introduced in 1972 by Gutman and Trinajstić. The first Zagreb index M1 is equal to the sum of the squares of the degrees of the vertices, and the second Zagreb index M2 is equal to the sum of the products of the degrees of pairs of adjacent vertices. Let $K_{n_1,n_2}^{P}$ with n1 $\leq$ n2, n1 + n2 = n and p < n1 be the set of bipartite graphs obtained by deleting p edges from complete bipartite graph Kn1,n2. In this paper, we determine sharp upper and lower bounds on Zagreb indices of graphs from $K_{n_1,n_2}^{P}$ and characterize the corresponding extremal graphs at which the upper and lower bounds on Zagreb indices are attained. As a corollary, we determine the extremal graph from $K_{n_1,n_2}^{P}$ with respect to Zagreb coindices. Moreover a problem has been proposed on the first and second Zagreb indices.

Low Index Contrast Planar SiON Waveguides Deposited by PECVD (PECVD 법에 의해 제작된 저굴절률 차이 평판 SiON광도파로)

  • Kim, Yong-Tak;Yoon, Seok-Gyu;Yoon, Dae-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.3 s.274
    • /
    • pp.178-181
    • /
    • 2005
  • Silicon oxynitride (SiON) layers deposited upon a $SiO_2/Si$ buffer layer placed upon silicon wafers have been obtained by using PECVD from $SiH_4,\;N_2O$, and $N_2$. It can be seen that the refractive index, measured by using a prism coupler, for the SiON films can be varied between 1.4480 and 1.4958 at a wavelength of 1552 nm by changing the process parameters. Optical planar waveguides with a thickness of $6{\mu}m$ and a refractive index contrast ($\Delta$n) of $0.36\% have been deposited. Also, etching experiments were performed using ICP dry etching equipment on thick SiON films grown onto Si substrates covered by a thick $SiO_2$ buffer layer. A polarization maintaining single-mode fiber was used for the input and a microscope objective for the output at $1.55{\mu}m$. As a result, a low index contrast SiON based waveguide is fabricated with easily adjustable refractive index of core layer. It illustrates that the output intensity mode is a waveguiding single-mode.