• Title/Summary/Keyword: $LS_{50}$

Search Result 150, Processing Time 0.027 seconds

The AC loss of 22.9kV/50MVA High-Tc Superconducting Power Cable (22.9kV/50MVA급 고온초전도 전력케이블의 교류손실)

  • Choi, Suk-Jin;Lee, Sang-Jin;Sim, Ki-Deok;Cho, Jeon-Wook;Lee, Soo-Gil;Yang, Byeong-Mo;Yoon, Hyung-Hee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.31-34
    • /
    • 2009
  • An HTS power cable is generally composed of 2 layers for conducting and 1 layer for shielding. For the analysis of AC loss of an HTS power cable, 2-dimensional magnetic field analysis is carried out. The magnetization loss in HTS cable core was calculated, and the transport current loss was obtained from the monoblock equation and the elliptical Norris Equation. And the total AC loss of the cable was expected by the sum of magnetization loss and transport current loss. The variation of ac loss with respect to the gap and uncertain factor between the superconducting tapes was investigated, and the ac loss of 22.9kV/50MVA high-Tc superconducting power cable was calculated. These results well agree with those of experiment.

Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging

  • Ayaz, Irem;Shaheen, Eman;Aly, Medhat;Shujaat, Sohaib;Gallo, Giulia;Coucke, Wim;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • Purpose: This study was conducted to objectively and subjectively compare the accuracy and reliability of 2-dimensional(2D) photography and 3-dimensional(3D) soft tissue imaging. Materials and Methods: Facial images of 50 volunteers(25 males, 25 females) were captured with a Nikon D800 2D camera (Nikon Corporation, Tokyo, Japan), 3D stereophotogrammetry (SPG), and laser scanning (LS). All subjects were imaged in a relaxed, closed-mouth position with a normal smile. The 2D images were then exported to Mirror® Software (Canfield Scientific, Inc, NJ, USA) and the 3D images into Proplan CMF® software (version 2.1, Materialise HQ, Leuven, Belgium) for further evaluation. For an objective evaluation, 2 observers identified soft tissue landmarks and performed linear measurements on subjects' faces (direct measurements) and both linear and angular measurements on all images(indirect measurements). For a qualitative analysis, 10 dental observers and an expert in facial imaging (subjective gold standard) completed a questionnaire regarding facial characteristics. The reliability of the quantitative data was evaluated using intraclass correlation coefficients, whereas the Fleiss kappa was calculated for qualitative data. Results: Linear and angular measurements carried out on 2D and 3D images showed excellent inter-observer and intra-observer reliability. The 2D photographs displayed the highest combined total error for linear measurements. SPG performed better than LS, with borderline significance (P=0.052). The qualitative assessment showed no significant differences among the 2D and 3D imaging modalities. Conclusion: SPG was found to a reliable and accurate tool for the morphological evaluation of soft tissue in comparison to 2D imaging and laser scanning.

Analysis of Power Requirement of Agricultural Tractor during Baler Operation (베일러 작업 시 트랙터 소요동력 분석)

  • Kim, Yong-Joo;Lee, Dae-Hyun;Chung, Sun-Ok;Park, Seung-Jae;Choi, Chang-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.36 no.4
    • /
    • pp.243-251
    • /
    • 2011
  • Purpose of this study was to analyze power requirement of an agricultural tractor for baler operation. First, a power measurement system was developed and installed in a 75 kW agricultural tractor. Strain-gages with a telemetry system were used to measure torques of transmission and PTO input shafts. An engine tachometer was used to measure rotational speed of transmission and PTO input shafts. The measurement system also included pressure sensors to measure pressure of hydraulic pumps, an I/O interface to acquire the sensor signals, and an embedded system to determine power requirements. Second, field experiments were conducted at two PTO speed levels, and proportion of utilization ratio of rated engine power and power consumption of major parts (transmission input shaft, PTO input shaft, main hydraulic pump, and auxiliary hydraulic pump) were analyzed. Results of usage proportion of engine power for PTO speed level 1 and 2 were 4.1 and 2.2%, 31.5 and 16.3%, 49.6 and 59.7%, 14.4 and 20.8%, and 0.4 and 1.0%, respectively, for ratio of measured engine power to rated engine power of less than 25%, 25 ~ 50%, 50 ~ 75%, 75 ~ 100%, and greater than 100%. The results showed that the usage proportion increased in the range with the ratio of power requirement to rated engine power of over than 50% when the PTO gear was shifted from P1 to P2. Averaged engine power requirement for baling operation, tying and discharging operation, and total operation were 43.3, 37.3, and 42.0 kW and 49.0, 37.0, and 47.4 kW, respectively, for PTO speed level 1 and 2. Paired t-test showed significant difference in power consumption of engine, transmission input shaft, and PTO input shaft for different PTO speed levels. Therefore, the power consumption of engine for baler operation increased when the PTO gear was shifted from P1 to P2. It was indicated that the power requirement of tractor was affected by the PTO rotational speed for baler operation.

A Study on Characteristics of Fly and Bed Ash in Circulating Fluidized Bed Combustion Boiler According to Particle Size of Limestone (석회석 입도의 변화가 석탄회의 성상에 미치는 영향에 관한 연구)

  • Chung Jin-Do;Kim Jang-Woo;Ha Joon-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.6
    • /
    • pp.587-592
    • /
    • 2006
  • The advantage of CFBC(Circulating fluidized bed combustor) is that it can apply to various fuel sources including the lower rank fuel and remove SOx by means of direct supply of limestone to the combustor without additional desulfation facility. In this paper, we denote characteristics of fly and bed ash to reuse finer limestone usually abandoned(used spec[Coarse LS] 0.1mm under 25%, new spec[Fine LS] 0.1mm under 50%). According to the results, the chemical composition of fly ash was as follows; $SiO_2\;40.8%,\;Al_2O_3\;31.9%,\;CaO\;10.7%,\;K_2O\;4.46%$ in the case of coarse limestone and $SiO_2\;41.1%,\;Al_2O_3\;31.3%,\;CaO\;10.9%,\;K_2O\;4.66%$ in the case of fine limestone. The chemical composition of bed ash was as follows; $SiO_2\;54.2%,\;Al_2O_3\;33.1%,\;CaO\;1.56%,\;K_2O\;4.34%$ in the case of coarse limestone and $SiO_2\;53.8%,\;Al_2O_3\;32.6%,\;CaO\;2.21%,\;K_2O\;4.45%$ in the case of fine limestone. It showed that there was no significant change in chemical composition. And it is conformed that there was no significant change in particle size and shapes.

Anti-wear performance and life evaluation of wheel bearing type greases

  • Kim Jung-Young;Chung Keun-Wo;Kim Young-Wun;Jo Won-Oh
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.111-116
    • /
    • 2004
  • Li-complex and urea type greases (each 10 species) which were furnished by Chang-Am LS, analyzed anti-wear performance into fretting wear tester & four-bail wear tester. from the results of fretting wear test, the wear volume of Li-complex greases are $4.6\~8.9mg\;and\;8.3\~14.4mg$ with the test of urea greases. The anti-wear performance for 4-ball wear test of greases produced results around 0.5mm at the value of WSD. The grease life performance were evaluated by SKF-ROF Grease Tester and wheel bearing life tester. From the results of SKF-ROF tester, the life performance evaluated by whole working time produced results $50\~300hr$ with the Li-complex greases and 100-1000hr with the urea greases. That is to say, in spite of severe condition at the higher of $10^{\circ}C$ reaction temp, the life performance with Urea type greases are much superior to Li-complex type greases. Prior to wheel bearing life tester, the grease selected performance evaluation(=anti-wear test) are tested by wheel bearing tester. In this results, we can confirm results those are similar with SKF-ROF tester. In this study, we can draw two major conclusions, one is that Li-complex greases are superior to urea greases with anti-wear properties and the other is that urea greases are much superior to Li-complex greases with life performance.

  • PDF

Electrophysiological and Morphological Classification of Inhibitory Interneurons in Layer II/III of the Rat Visual Cortex

  • Rhie, Duck-Joo;Kang, Ho-Young;Ryu, Gyeong-Ryul;Kim, Myung-Jun;Yoon, Shin-Hee;Hahn, Sang-June;Min, Do-Sik;Jo, Yang-Hyeok;Kim, Myung-Suk
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.6
    • /
    • pp.317-323
    • /
    • 2003
  • Interneuron diversity is one of the key factors to hinder understanding the mechanism of cortical neural network functions even with their important roles. We characterized inhibitory interneurons in layer II/III of the rat primary visual cortex, using patch-clamp recording and confocal reconstruction, and classified inhibitory interneurons into fast spiking (FS), late spiking (LS), burst spiking (BS), and regular spiking non-pyramidal (RSNP) neurons according to their electrophysiological characteristics. Global parameters to identify inhibitory interneurons were resting membrane potential (>-70 mV) and action potential (AP) width (<0.9 msec at half amplitude). FS could be differentiated from LS, based on smaller amplitude of the AP (<∼50 mV) and shorter peak-to-trough time (P-T time) of the afterhyperpolarization (<4 msec). In addition to the shorter AP width, RSNP had the higher input resistance (>200 $M{Omega}$) and the shorter P-T time (<20 msec) than those of regular spiking pyramidal neurons. Confocal reconstruction of recorded cells revealed characteristic morphology of each subtype of inhibitory interneurons. Thus, our results provide at least four subtypes of inhibitory interneurons in layer II/III of the rat primary visual cortex and a classification scheme of inhibitory interneurons.

Uniformity of Bi2212 Tubes Depending on Cooling Conditions (냉각 속도에 따른 Bi-2212 초전도 튜브의 균일성)

  • Lee, Nam-Il;Jnag, Gun-Eik;Park, Gwon-Bae;Oh, Il-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.259-260
    • /
    • 2006
  • This study was progressed to value of Bi2212 tubes uniformity depend on cooling conditions. The tube from 150 mm in length, 30 mm in O.D., 20 mm in I.D., 5 mm in thickness was combined with electrodes by 3 sections. The tube from 60, 70 mm in length, 30, 50 mm in O.D., 20.4, 40.4 mm in I.D., 4.8 mm in thickness was in controled of cooling rate by a heat exchanger. Bi2212 tubes were fabricated by Centrifugal Forming Process (CFP) and they were annealed at $840^{\circ}C$ for 80 h in oxygen atmosphere. The tube from 150 mm in length was analyzed by EFDLab of NIKA to show cooling rate and temperature distributions. When the tube was cooled for 100s, the temperature distributions was $663^{\circ}C$ in the middle, $500{\sim}647^{\circ}C$ in inlet, $598{\sim}647^{\circ}C$ in the other side. Electric characteristics from $I_c$ was 450 A in the middle, 650 A in inlet, 600 A in the other side. Electric characteristics by a heat exchanger showed the more fast cooling rate, the more high $I_c$.

  • PDF

Cryopreservation of Citrus limon (L.) Burm. F Shoot Tips Using a Droplet-vitrification Method

  • Yi, Jung-Yoon;Balaraju, Kotnala;Baek, Hyung-Jin;Yoon, Mun-Seop;Kim, Haeng-Hoon;Lee, Young-Yi
    • Korean Journal of Plant Resources
    • /
    • v.31 no.6
    • /
    • pp.684-694
    • /
    • 2018
  • This study describes the successful establishment of a cryopreservation protocol for Citrus limon cultivars: 'Frost Eureka limon' and 'Cook Eureka limon', using a droplet-vitrification method. The shoot tips that were excised from in vitro grown seedlings of the two cultivars were preserved in liquid nitrogen (LN) and successfully regenerated into whole plants. Excised shoot tips were pre-cultured for 1 or 2 days in 0.3 M and 0.5 M sucrose solutions at $25^{\circ}C$ and incubated in a loading solution (LS) composed of 17.5% glycerol + 17.5% sucrose in Murashige and Skoog (MS) medium for 40 min at $25^{\circ}C$. Prior to direct immersion in LN for 1 h, the shoot tips were dehydrated with plant vitrification solution 2 (PVS2) at $0^{\circ}C$ or PVS3 at $25^{\circ}C$. The frozen shoot tips were re-warmed and unloaded with 1.2 M sucrose in $\text\tiny{^1/_2}$ MS for 30 min at $25^{\circ}C$. Shoot tips were post-cultured overnight on survival medium and then micrografted onto 'trifoliate orange' (Poncirus trifoliate (L.) Raf. seedling rootstocks for recovery and to produce whole plants. The highest regrowth rates were 53.5% and 50.3% for cryopreserved shoot tips of 'Frost Eureka limon' and 'Cook Eureka limon', respectively, when pre-cultured in 0.3 M and 0.5 M sucrose concentrations in a sequencing manner, with LS and treated with PVS2 for 60 min at $0^{\circ}C$. We also investigated whether the ammonium ion concentration on post-culture medium affected the viability of the cryopreserved Citrus shoot tips. The viability of cooled samples, following culturing on woody plant media (WPM) containing $\text\tiny{^1/_4}$ ammonium nitrate overnight before micrografting, was the highest (70.3%) in 'Frost Eureka limon'. The study described here is a cost-effective and safe method to conserve Citrus fruit cultivars, for the improvement and large-scale multiplication of fruit plants and for breeding disease resistance.

Feasibility study on the design of DC HTS cable core

  • Sim, Ki-Deok;Kim, Seok-Ho;Jang, Hyun-Man;Lee, Su-Kil;Won, Young-Jin;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.24-30
    • /
    • 2010
  • The renewable energy source is considered as a good measure to cope with the global warming problem and the fossil energy exhaustion. The construction of electric power plant such as an offshore wind farm is rapidly increasing and this trend is expected to be continued during this century. The bulky and long distance power transmission media is essential to support and promote the sustainable expansion of renewable energy source. DC power cable is generally considered as the best solution and the demand for DC electric power has been rapidly increasing. Especially, the high temperature superconducting (HTS) DC cable system begins to make a mark because of its advantages of huge power transmission capacity, low transmission loss and other environmental friendly aspects. Technical contents of DC HTS cable system are very similar to those of AC HTS cable system. However the DC HTS cable can be operated near its critical current if the heat generation is insignificant, while the operating current of AC HTS cable is generally selected at about 50~70% of the critical current because of AC loss. We chose the specifications of the cable core of 'Tres Amigas' project as an example for our study and investigated the heat generation when the DC HTS cable operated near the critical current by some electric and thermal analyses. In this paper, we listed some technical issues on the design of the DC HTS cable core and described the process of the cable core design. And the results of examination on the current capacity, heat generation, harmonic loss and current distribution properties of the DC HTS cable are introduced.

Simulation of Low Velocity Impact of Honeycomb Sandwich Composite Panels for the BIMODAL Tram Application (바이모달 트램 적용 하니컴 샌드위치 복합재 패널의 저속 충격 해석)

  • Lee, Jae-Youl;Jeong, Jong-Cheol;Shin, Kwang-Bok
    • Composites Research
    • /
    • v.20 no.4
    • /
    • pp.42-50
    • /
    • 2007
  • This paper describes the results of experiments and numerical simulation studies on the low-velocity impact damage of two different sandwich composite panels for application to bodyshell and floor structure of the BIMODAL tram vehicle. Square test samples of 100mm sides were subjected to low-velocity impact loading using an instrumented testing machine at four impact energy levels. Part of this work presented is focused on the finite element analysis of low-velocity impact response onto a sandwich composite panels. It is based on the application of explicit finite element (FE) analysis codes LS-DYNA 3D to study the impact response of sandwich structures under low-velocity impact conditions. Material testing was conducted to determine the input parameters for the metallic and composite material model, and the effective equivalent damage model for the orthotropic honeycomb materials. Numerical and experimental results showed a good agreement for damage area and the depth of indentation of sandwich composite panels created by the impact loading.