• Title/Summary/Keyword: $K_w$

Search Result 33,106, Processing Time 0.058 seconds

A NOTE ON w-NOETHERIAN RINGS

  • Xing, Shiqi;Wang, Fanggui
    • Bulletin of the Korean Mathematical Society
    • /
    • v.52 no.2
    • /
    • pp.541-548
    • /
    • 2015
  • Let R be a commutative ring. An R-module M is called a w-Noetherian module if every submodule of M is of w-finite type. R is called a w-Noetherian ring if R as an R-module is a w-Noetherian module. In this paper, we present an exact version of the Eakin-Nagata Theorem on w-Noetherian rings. To do this, we prove the Formanek Theorem for w-Noetherian rings. Further, we point out by an example that the condition (${\dag}$) in the Chung-Ha-Kim version of the Eakin-Nagata Theorem on SM domains is essential.

Design and Implementation of Software Utilizing The SDR Software Platform (SDR S/W 폴랫폼을 활용한 S/W 설계 및 구현)

  • Park, Uram;Lee, Jae-Gyun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.485-486
    • /
    • 2016
  • 본 논문에서는 SDR SW 플랫폼을 기반으로 활용 분야에 적용될 수 있는 4종 S/W를 제안한다. SDR SW 플랫폼은 openAPI로 제공되어 확장성과 활용성 및 유연성 측면에 장점이 있다. 웹 서비스를 기반으로 구현한 4종 SW는 교육용, 경계용, 감시용, 교통용으로 각 S/W의 목적성에 따라 사용하는 파형과 밴드를 설정하여 운용하도록 구성하였고, 운용시에 발생한 데이터를 그래프, 도표 등의 시각적으로 사용자에게 정보를 제공한다. 교육용 S/W는 다중대역, 다중파형 설정 및 다양한 정보 제공, 경계용 S/W는 실외 특정 구역 감시, 감시용 S/W는 실내 침입자 탐지, 교통용 S/W는 실시간 차량 현황과 과속 탐지 등 각 S/W에 따라 특정 활용 목적에 기능을 구생하여 구현하였다.

Determination of Nursing Costs for Hospitalized Patients Based on the Patient Classification System (종합병원에 입원한 환자의 간호원가 산정에 관한 연구)

  • 박정호;송미숙
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.1
    • /
    • pp.16-37
    • /
    • 1990
  • A cost analysis for hospitalized patients was carried out based upon Patient Classification System(PCS) in order to determine an appropriate nursing fee. The data were collected from 21 nursing units of three teaching hospitals from April 1 to June 30, 1989. first, all of the 22,056 inpatients were classified into mildly ill(Class Ⅰ), moderately ill(Class Ⅱ), acutely ill(Class Ⅲ), and critically ill(Class Ⅳ) by the PCS which had been carefully developed to be suitable for the Korean nursing units. Second. PCS cost accounting was applied to the above data. The distribution of inpatients, nursing costs, and nursing productivity were as follows : 1) Patient distribution ranged from 45% to class Ⅰ, 36% to class Ⅱ, 15% to class Ⅲ, and 4% to class Ⅳ, the proportion of class Ⅳ in ‘H’ Hospital was greater than that of the other two hospitals. 2) The proportion of Class Ⅲ and Ⅳ in the medical nursing units was greater than that of surgical nursing units. 3) The number of inpatients was greatest on Tuesdays, and least on Sundays. 4) The average nursing cost per hour was W 3,164 for ‘S’ hospital, W 3,511 for ‘H’ hospital and W 4,824 for ‘K’ hospital. The average nursing cost per patient per day was W 14,126 for ‘S’ Hospital, W 15,842 for ‘H’ hospital and W 21,525 for ‘K’ hospital. 5) The average nursing cost calculated by the PCS was W 13,232 for class Ⅰ, W 18,478 for class Ⅱ, W 23,000 for class Ⅲ, and W 25,469 for class Ⅳ. 6) The average nursing cost for the medical and surgical nursing units was W 13,180 and W 13,303 respetively for class Ⅰ, W 18,248 and W 18,707 for class Ⅱ, W 22,303 and W 23,696 for class Ⅲ, and W 24,331 and W 26,606 for class Ⅳ. 7) The nursing costs were composed of 85% for wages and fringe benefits, 3% for material supplies and 12% for overhead. The proportion of wages and fringe benefits among the three Hospitals ranged from 75%, 92% and 98% for the ‘S’, ‘H’, ‘K’ hospitals respectively These findings explain why the average nursing cost of ‘K’ hospital was higher than the others. 8) According to a multi- regression analysis, wages and fringe benefits, material supplies, and overhead had an equal influence on determining the nursing cost while the nursing hours had less influence. 9) The productivity of the medical nursing units were higher than the surgical nursing units, productivity of the D(TS) - nursing units was the lowest while the K(Med) - nursing unit was the highest in 'S' hospital. In ‘H’ hospital, productivity was related to the number of inpatients rather than to the characteristics of the nursing units. The ‘K’ hospital showed the same trend as ‘S’ hospital, that the productivity of the medical nursing unit was higher than the surgical nursing unit. The productivity of ‘S’ hospital was evaluated the highest followed by ‘H’ hospital and ‘K’ hospital. Future research on nursing costs should be extended to the other special nursing areas such as pediatric and psychiatric nursing units, and to ICU or operating rooms. Further, the PCS tool should be carefully evaluated for its appropriateness to all levels of institutions(primary, secondary, tertiary). This study took account only of the quantity of nursing services when developing the PCS tool for evaluating the productivity of nursing units. Future research should also consider the quality of nursing services including the appropriateness of nursing activities.

  • PDF

Magnetism in Ni-W textured substrates for coated conductors

  • Song K. J.;Park Y. M.;Yang J. S.;Kim S. W.;Ko R. K.;Kim H. S.;Ha H. S;Oh S. S.;Park C.;Joo J. H.;Kim C. J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.7-10
    • /
    • 2005
  • The magnetic properties of a series of both annealed (biaxially textured) and as-rolled (non-textured) Ni-xW alloy tapes with compositions x = 0,1,3, and 5 at.$\%$, were studied. Characterization methods included XRD analyses to investigate the biaxial cube texturing of the annealed Ni-W alloy tapes and studies of the magnetization M for both annealed and as-rolled Ni-W alloy tapes. Both the isothermal mass magnetizations M(H) of a series of samples at different fixed temperatures and M(T) in fixed field, employing a PPMS-9 (Quantum Design), were measured. The Ni-W alloys have shown much reduced ferromagnetism as W-content x increases. Both the saturation magnetization Msat and Curie temperature Tc decrease linearly with W-content x, and both Msat and Tc go to zero at critical concentration of Xc - 9.50 at. $\%$ W.

Experimental Research on an Organic Rankine Cycle Using Engine Exhaust Gas (엔진 배기열 이용 유기랭킨사이클에 대한 실험적 연구)

  • Shin, Dong Gil
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.393-397
    • /
    • 2012
  • In this study, an organic Rankine cycle(ORC) for gas engine waste heat recovery for industry has been constructed and a performance analysis test has been carried out. Shell & tube style heat exchanger has been equipped on an engine exhaust manifold in order to absorb heat of engine exhaust gas into the working fluid(refrigerant R134a). Under 60 kW of engine power output, about 63 kW of engine exhaust gas heat was discharged and the proportion of heat recovered was 68~73% while 43~46 kW of heat was absorbed into working fluid. Consequently rated power output of ORC was 4.6 kW while the ratio of rated power output to engine exhaust gas heat was 7.3%.

Simulation of Under-Ventilated Fires (환기부족 화재의 시뮬레이션)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.12-16
    • /
    • 2016
  • Propane fires of 1000 to 3000 kW in the ISO 9705 fire room were simulated using FDS to study the problem of decreasing temperature with increasing fire size. A criterion is proposed for under-ventilated fires. The computed temperature at 2000 kW and above was lower than that at 1500 kW. The heat release rate was limited by a lack of oxygen in the simulation. It was found that the heat release rate can therefore be a criterion for under-ventilated fires in simulations. Fires of 1700 kW and above in the ISO 9705 fire room are predicted to be under-ventilated.

Development of 5kW PCS for SOFC System (5kW급 SOFC 시스템용 전력변환장치 개발)

  • Lee, J.M.;Choi, J.Y.;Kim, Y.W.;Yi, J.H.;Seo, Y.G.;Suh, I.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.332-333
    • /
    • 2010
  • The 5kW SOFC(Solid Oxide Fuel Cell) System is composed to 3kW parallel Fuel Cell. We propose to the parallel control of 5kW PCS in the unbalance condition of fuel cell. The developed 5kW PCS can be found control ability of DC/DC converters in the operating conditions of the unbalanced parallel operation. It is verify to the control characteristics by simulation and experiment.

  • PDF

Development of a Simulator for 750 kW Gearless Wind Turbine (750kW gearless형 풍력발전 시스템용 모의시험 장치의 개발)

  • Kwon S. J.;Son Y. G.;Seo J. H.;Lee W. W.;Jang S. D.;Oh J. S.;Hwang J. S.;Park G. W.;Kwon O. J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1190-1192
    • /
    • 2004
  • 풍력을 이용한 풍력발전기의 전력변환 시스템을 개발하기 위해서는 바람특성을 정확히 분석하고 이를 대치할 수 있는 모의시험 장치가 필수적이다. 모의시험 장치는 풍향, 풍속 등의 인자들을 입력받아 회전 블레이드의 토오크를 전동기가 대신해서 발전기에 공급하게 된다. 본 논문에서는 풍력발전 모의시험 장치를 이용해서 현재 개발 중인 750kW gearless형 풍력발전 시스템의 인버터 특성과 고효율의 전력변환 설계를 위해 시험용 지그에서 시험한 결과를 보이고자 한다.

  • PDF

Effect of Substituted Residue 139 and 258 on Structural Changes of Mutant Tryptophan Synthase Pro96→Leu α-Subunit (트립토판 중합효소 α 소단위 잔기 치환체 Pro96→Leu의 구조 변화에 영향을 미치는 139 및 258 잔기의 치환 효과)

  • Lee, Joo-Youn;Jeong, Jae-Kap;Shin, Hae-Ja;Lim, Woon-Ki
    • Journal of Life Science
    • /
    • v.12 no.4
    • /
    • pp.464-468
    • /
    • 2002
  • Enzymatic activities and fluorescence spectroscopic properties of the double mutant proteins P96L/F139W, P96L/F258W and a triple mutant protein P96L/F139W/F258W of tryptophan synthase $\alpha$ subunit from Escherichia coli was examined to study tertiary and local structure changes around the tryptophan residues. The enzymatic activities of P96l./F139W and P96L/F258W were similar, but P96L/F139W/F258W had lower activity, as compared to wild type. The fluorescence intensities of double mutant, P96L/F139W and P96L/F258W, were decreased but that of a triple mutant, P96L/F139W/F258W, was increased when compared to wild type. The sum of the maximum fluorescence intensity (fluorescence intensity at the λ$_{max}$) for the double mutant proteins was not equal to the intensity seen in the triple mutant protein. The enzymatic activity and fluorescence data indicate that the replacement of Pro$^{96}$ longrightarrowLeu might affect on the stability of helix 8 and the loop located between strand 4 and helix4. The result suggests that the tertiary structure of triple mutant (P96L/F139W/F258W), being different from wild type, might have more compact residual structure at the vicinity of 139 and 258.8.