• Title/Summary/Keyword: $K_1$(mode 1)

Search Result 5,739, Processing Time 0.035 seconds

Comparison of Characteristics between $L_1-B_4$ mode and $L_1-B_8$ mode Ultrasonic Motors ($L_1-B_4$모드와 $L_1-B_8$모드 초음파 선형 전동기의 특성 비교)

  • U, Sang-Ho;Kim, Dong-Yeon;Kim, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1518-1520
    • /
    • 2002
  • Purpose of this research compares best transfer speed about applied frequency and voltage using characteristic of $L_1-B_4$ mode and $L_1-B_8$ mode linear ultrasonic motor that use piezoelectric effect. By method of study, analyzed best transfer speed measuring and comparison load status that use actuality telephone card in $L_1-B_4$ mode linear ultrasonic motor and no-load status of $L_1-B_8$ mode linear ultrasonic motor. Experiment result is applied frequency(58.4Hz) in $L_1-B_4$ mode linear ultrasonic motor (load state) and the best transfer speed by 19.8[cm/s] at applied voltage(56V) point. Also, $L_1-B_8$ mode linear ultrasonic motor (no-load state) is best transfer speed by applied frequency(27.9kHz) and 32.96[cm/s] at applied voltage (50V) point.

  • PDF

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

Mark XIIA(Mode 5) IFF System Integration and Certification Test for Surface to Air Missile System (유도무기체계 모드 5 피아식별 체계통합 및 인증시험)

  • Kim, Woo-Hyun;Jung, Se-Young;Lee, Yun-Soo;Chang, Se-Myong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.160-168
    • /
    • 2022
  • The new IFF mode, Mode-5 replacing Mode-4, has already been established by the US DoD for its allies and NATO forces. A IFF retrofit program for replacing the Mark XII Mode-4 with Mark XIIA Mode-5 is in progress in order to overcome the security limitations of the former in R.O.K. IFF certification test for the new mode, Mode-5, has been performed on medium range surface to air missile platform of the Korean armed forces for the first time in R.O.K and this is regarded as a monumental event in Korean defense industry. The present paper is a discussion on the procedures applied to the IFF system retrofit and integration, lessons learned from AIMS test with the US AIMS PO as observer. The minimum modification from the existing Mark XII Mode-4 to Mark XIIA Mode-5 and evolutional adaption from previous design including interoperability are required for the system retrofit. Letter of Certification was received from the US AIMS PO after the tests. The authors propose that the lessons learned and know-how acquired during the tests are managed by the R.O.K Government as the standard structure of a database. It is expected that the use of the database will reduce the developmental difficulties and risk, also increase efficiency in future developments and other projects.

Attenuation of Fundamental Longitudinal Guided Wave Mode in Steel Pipes Embedded in Soil

  • Lee, Ju-Won;Shin, Sung-Woo;Na, Won-Bae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.6
    • /
    • pp.539-547
    • /
    • 2010
  • In this study, characteristics of the fundamental longitudinal guided wave mode, L(0,1), which is a usual mode employed in the inspection of the above-ground pipe, of the buried pipe were numerically investigated considering property changes in the surrounding soil. Results showed that soil conditions are significantly affecting the attenuation of L(0,1) mode in the pipe embedded in soil. Especially, if the soil is partially saturated, the attenuation of L(0,1) mode is larger and is very similar regardless of the degree of water saturation in the surrounding soil. However, when the soil is fully saturated, the attenuation of L(0,1) mode is less and show different trend with its partially saturated counterparts.

Mode Control Design of Dual Buck Converter Using Variable Frequency to Voltage Converter (주파수 전압 변환을 이용한 듀얼 모드 벅 변환기 모드 제어 설계)

  • Lee, Tae-Heon;Kim, Jong-Gu;So, Jin-Woo;Yoon, Kwang-Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.864-870
    • /
    • 2017
  • This paper describes a Dual Buck Converter with mode control using variable Frequency to Voltage for portable devices requiring wide load current. The inherent problems of PLL compensation and efficiency degradation in light load current that the conventional hysteretic buck converter has faced have been resolved by using the proposed Dual buck converter which include improved PFM Mode not to require compensation. The proposed mode controller can also improve the difficulty of detecting the load change of the mode controller, which is the main circuit of the conventional dual mode buck converter, and the slow mode switching speed. the proposed mode controller has mode switching time of at least 1.5us. The proposed DC-DC buck converter was implemented by using $0.18{\mu}m$ CMOS process and die size was $1.38mm{\times}1.37mm$. The post simulation results with inductor and capacitor including parasitic elements showed that the proposed circuit received the input of 2.7~3.3V and generated output of 1.2V with the output ripple voltage had the PFM mode of 65mV and 16mV at the fixed switching frequency of 2MHz in hysteretic mode under load currents of 1~500mA. The maximum efficiency of the proposed dual-mode buck converter is 95% at 80mA and is more than 85% efficient under load currents of 1~500mA.

Driving Characteristics of L1-B8 Mode Ultrasonic Motor (L1-B8형 초음파 모터의 구동 특성)

  • Kim, Hang-Sik;Park, Tae-Gone;Kim, Myong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.356-359
    • /
    • 2003
  • This paper deals with a flat type ultrasonic motor, which uses a longitudinal-bending multi mode vibrator of rectangular form. This ultrasonic motor was designed by combination of the first longitudinal and eighth bending mode, and the motor consisted of a straight aluminum alloy bar bonded with piezoelectric ceramic elements as a driving element. The geometrical dimensions of the rectangular aluminum vibrator were determined by Euler-Bernoulli theory In the experimental device, piezoelectric ceramics ( a piece of ceramic for the L-mode, $24\;{\times}\;8\;{\times}\;1[mm]$, and four pieces for the B-mode, $12.5\;{\times}\;8\;{\times}\;1[mm]$) were attached to one side of a aluminum plate($100\;{\times}\;8\;{\times}\;1[mm]$), and the stator was supported with a plastic case. As results, no-load rpm was 50[rev./m] when applied voltage was 150[Vrms] at the resonance frequency, and as the voltage was increased, the rpm was increased.

  • PDF

Solid-State Laser Mode-Locking Near 1.25 μm Employing a Carbon Nanotube Saturable Absorber Mirror

  • Cho, Won-Bae;Choi, Sun-Young;Kim, Jun-Wan;Yeom, Dong-Il;Kim, Ki-Hong;Rotermund, Fabian;Lim, Han-Jo
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.56-60
    • /
    • 2011
  • We demonstrate passive mode-locking of a Cr:forsterite laser with a single-walled carbon nanotube saturable absorber mirror (SWCNT-SAM). Without compensation of intra-cavity dispersion, the self-mode-locked laser generates 11.7 ps pulses at a repetition rate of 86 MHz. The dispersion-compensated laser yields ultrashort pulses as short as 80 fs near $1.25\;{\mu}m$ at 78 MHz with average output powers up to 295 mW, representing the highest power ever reported for mode-locked solid-state lasers based on saturable absorption of SWCNTs in this spectral region.

Instability of High-Speed Impinging Jets(II) (고속 충돌제트의 불안정 특성)

  • Gwon, Yeong-Pil;Im, Jeong-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.450-467
    • /
    • 1998
  • The characteristics of the unstable impinging circular jet is investigated based on the frequency characteristics and the sound field of the impinging-tones. Two symmetric modes S1 and S2, associated with low frequency and high frequency respectively, and one helical mode H have been observed. At low speed the S2 mode is dominant and switched by the S1 mode as the speed increases. When the jet speed is high the S1 mode is very active over the impinging distance from half the nozzle diameter to its ten times, while the S2 mode occurs at shorter distance corresponding to stage 2 and 3. The helical mode H seems unstable, likely to be influenced much by the experimental environment, and occurs at relatively high speed with almost the same frequency characteristics as the S2 mode. By estimating the convection speed of the unstable jet, it is found that the ratio of the convection speed to the jet speed decreases with both Strouhal number and Reynolds number and the speed of S2 mode is faster than the Si mode. When the present experimental results are compared with the previous investigations performed for the hole tone and the impinging tone with a small plate, the S1 mode is found to be associated with the ring vortex of large diameter with low speed, but the S2 mode with the vortex of small diameter with high speed. In addition, the frequency is found to be influenced by the nozzle configuration but the characteristics is almost the same. From the impinging distance and frequency range, it can be deduced that S1 mode is related with the jet column mode and S2 mode with the shear mode.

Treatment Plan Delivery Accuracy of the ViewRay System in Two-Headed Mode

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.169-174
    • /
    • 2016
  • The aim of this study is to investigate the delivery accuracy of intensity-modulated radiation therapy (IMRT) plans in the two-headed mode of the ViewRay$^{TM}$ system in comparison with that of the normal operation treatment plan of the machine. For this study, a total of eight IMRT plans and corresponding verification plans were generated (four head and neck, two liver, and two prostate IMRT plans). The delivered dose distributions were measured using ArcCHECK$^{TM}$ with the insertion of an ionization chamber. We measured the delivered dose distributions in three-headed mode (normal operation of the machine), two-headed mode with head 1 disabled, two-headed mode with head 2 disabled, and two-headed mode with head 3 disabled. Therefore, a total of four measurements were performed for each IMRT plan. The global gamma passing rates (3%/3 mm) in three-headed mode, head 1 disabled, head 2 disabled, and head 3 disabled were $99.9{\pm}0.1%$, $99.8{\pm}0.3%$, $99.6{\pm}0.7%$, and $99.7{\pm}0.4%$, respectively. The difference in the gamma passing rates of the three- and two-headed modes was insignificant. With 2%/2 mm, the rates were $96.6{\pm}3.6%$, $97.2{\pm}3.5%$, $95.7{\pm}6.2%$, and $95.5{\pm}4.3%$, respectively. Between three-headed mode and head 3 disabled, a statistically significant difference was observed with a p-value of 0.02; however, the difference was minimal (1.1%). The chamber readings showed differences of approximately 1% between three- and two-headed modes, which were minimal. Therefore, the treatment plan delivery in the two-headed mode of the ViewRay$^{TM}$ system seems accurate and robust.

Quad-Band Bandpass Filter Using Quad-Mode Stub-loaded Resonators

  • Liu, Haiwen;Wang, Xiaomei;Wang, Yan;Li, Shen;Zhao, Yulong;Guan, Xuehui
    • ETRI Journal
    • /
    • v.36 no.4
    • /
    • pp.690-693
    • /
    • 2014
  • Compact multi-band bandpass filters using quad-mode stub-loaded resonators are proposed in this letter. Firstly, a novel approach about the mode-splitting characteristics of the quadruple-mode resonator is investigated, which can provide dual-band behavior. Secondly, a quad-band filter is proposed and designed by cascading two quadruple-mode resonators; the upper one operates at 1.8/2.4 GHz (GSM- and WiMax-band) and the lower one at 1.57/2.1 GHz (GPS- and WCDMA-band). Finally, the proposed filters have been fabricated. Respectable agreement between simulation and measurement verifies the validity of this design methodology.