• Title/Summary/Keyword: $K^+-ion$ Selective PVC Electrode

Search Result 61, Processing Time 0.019 seconds

Determination of Copper in Black, Red Pepper and the Waste Water Samples by a Highly Selective Sensitive Cu(II) Microelectrode Based on a New Hexadentates Schiff's Base

  • Norouzi, Parviz;Ganjali, Mohammad Reza;Faridbod, Farnoush;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1439-1444
    • /
    • 2006
  • A $Cu^{2+}$ ion-selective membrane microelectrode has been fabricated from poly vinyl chloride (PVC) matrix membrane containing a new symmetrical hexadentate Schiff,s base 2-{1-(E)-2-((Z)-2-{(E)-2-[(Z)-1-(2-hydroxyphenyl)ethylidene]hydrazono}-1-methylpropylidene)hydrazono]ethyl}phenol (HDNOS) as a neutral carrier, Potassium tetrakis(4-chlorophenyl) borate (KTpClPB) as an anionic excluder and o-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The microelectrode displays linear potential response in the concentration range of $1.0\;{\times}\;10^{-5}-1.0\;{\times}\;10^{-11}$ M of $Cu^{2+}$. The microelectrode exhibits a nice Nernstian slope of 25.9 ${\pm}$ 0.3 mV $decade^{-1}$ in the pH range of 3.1-8.1. The sensor has a relatively short response time in whole concentration ranges ($\sim$5 s). The detection limit of proposed sensor is $5.0\;{\times}\;10^{-12}$ M (320 pg/L), and it can be used over a period of eight weeks. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of $Cu^{2+}$ with EDTA. The proposed membrane electrode was used for the direct determining of $Cu^{2+}$ content in black and red pepper, and in waste water samples.

Cesium Ion-Selective Electrode Based on Upper-rim Calix[4]crown Ionophore (캘릭스 [4]크라운 유도체를 이온선택성 물질로 사용한 세슘이온 선택성 막전극)

  • Namgung, Miok;Ihm, Hyejae;Paek, Kyungsoo;Yun, Youngja
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.428-432
    • /
    • 2000
  • A PVC membrane electrode based on upper-rim calix[4]crown as ionophore was prepared using dioctyl sebacate (DOS) as a plasticizer. The potential response of this membrane electrode to alkali, alkaline earth metal cations were examined. This membrane electrode exhibited a Nemstian response to $10^{-5}-10^{-1}M$ of CsCI with a slope of 52.3 mV/decade in Tris-buffer(pH 7.20). Its response time ($t_{90%}$) was 10s and it could be used for at least 2 months.

  • PDF

Structural Characters of (Phenol-Formaldehyde-Aniline Polymer)-Nickel(Ⅱ) Nitrate ((Phenol-Formaldehyde-Aniline 중합체)-Nickel(Ⅱ) Nitrate 구조에 관한 연구)

  • Doo Soon Shin;Bong Keun Park
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.409-415
    • /
    • 1988
  • In this study, an aniline modified Bakelite-A resine was synthesized by polymerizing phenol, formaldehyde and aniline. Structural properties of the polymer were examined by IR spectroscopy, elemental analysis and vapour pressure osmometry. By visible spectroscopy, it was found that nitrogens of amine groups in the polymer are strongly coordinated to Ni(Ⅱ). Also a nitrate ion-selective PVC membrane electrode based on the polymer-Ni(Ⅱ) complex as ion carrier was preparaed. The electrode gave a linear response with a Nernstian slope within the concentration range $10^{-1}$ M∼$10^{-4}$M $KNO_3$.

  • PDF

Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System (ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링)

  • Han, Hee-Jo;Kim, Hak-Jin;Jung, Dae-Hyun;Cho, Woo-Jae;Cho, Yeong-Yeol;Lee, Gong-In
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.141-152
    • /
    • 2020
  • The rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.

The $Pb^{2+}$ Ion Affinitive Membrane Electrode Based on New Calix[4]arene Ionophore (새로운 캘릭스[4]아렌 유도체를 이용한 $Pb^{2+}$ 이온 친화성 막전극)

  • Kim, Eun Jin;Kim, Min Kyu;Nam Gung, Mi Ok;Paek, Kyung Soo;Yun, Young Ja
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.5
    • /
    • pp.531-538
    • /
    • 1998
  • The ion selective membrane electrode made of calix[4]arene-based host 1 as ionophore, poly (vinyl chloride) (PVC) as matrix and dioctylsebacate (DOS) as a plasticizer was studied. The potential responses of this membrane electrode to alkali, alkaline earth and transition metal cations were investigated. Especially this membrane electrode was turned out to be affinitive for $Pb^{2+}$ in the deionized water. It was observed that the response was linear in the concentration range from $1.0 \times 10^{-1} M to 1.0 \times 10^{-6} M of Pb^{2+}$ and its slope (26.5 mV/decade) was near to the sub-Nernstian response in deionized water. Also, the potential was maintained constantly in the range of pH $4.00 \sim 12.00$, which supports the potential usage as $Pb^{2+}$ affinitive electrode in the deionized water.

  • PDF

Improved Thiocyanate-Selective Electrode Based on Tetra(trimethylphenyl)-porphyrinato Manganese(III) Chloride: The Electronic and pH Effects

  • Seo, Hyung-Ran;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1484-1488
    • /
    • 2004
  • The thiocyanate-selective PVC membrane electrodes based on 5,10,15,20-tetrakis(2,4,6-trimethylphenyl)-porphyrinatomanganese(III) chloride [Mn(TMP)Cl] and 5,10,15,20-tetrakis(2,6-dichlorophenyl)porphyrinatomanganese(III) chloride $[Mn(Cl_8TPP)Cl]$ as ion carriers were investigated. The effect of ionophores, membrane compositions, plasticizers, and solution pHs on the response characteristics were studied. The Mn(TMP)Cl as an ionophore shows the best potentiometric sensitivity with a slope of -58.7 mV/decade and a detection limit of $log[SCN^-]$ = -6.90, and selectivity for thiocyanate over strong hydrophobic interfering anions such as ${ClO_4}^-$ and salicylate. The potentiometric response is affected by the electronic effect of the substituents and solution pHs. The presence of substituents with electron donating and more liphophilic characters around the ligated metal center produces an improved response toward $SCN^-$.

Lithium Ion Selective Electrode Based on a Synthetic Neutural Carrier (중성운반체를 이용한 리튬이온 선택 전극)

  • Kim, Jae Sang
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.33-39
    • /
    • 1992
  • THF-based crown-4 of 16-membered rings having tetrahydrofuran unit was synthesized by an acid-catalyzed condensation of furan and acetone followed by hydrogenation in an effort to obtain highly elective ionophores for lithium ions. The new ionophore was compared with previously reported ionophores under similar measurement conditions with the same plasticizer, tris(2-ethylhexyl) phosphate in poly(vinyl chloride)(PVC) membrane electrodes. Separate solution method was used to determine relative selectivity coefficients for the electrode. The selectivity coefficients($K_{LiM}^{POT}$) of lithium over ammonium, alkali and alkaline earth metal ions go from about $2.4{\times}10^{-1}$ to $2.3{\times}10^{-4}$ to working range and pH dependence have also been studied.

  • PDF

Tetrahydrofuran-Containing Crown Ethers as Ionophores for NH+4-Selective Electrodes

  • Jin, Hua-Yan;Kim, Tae-Ho;Kim, Jin-Eun;Lee, Shim-Sung;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.59-62
    • /
    • 2004
  • The ammonium ion-selective electrodes ($NH^+_4$-ISEs) based on the tetrahydrofuran(THF)-containing-16-crown-4 derivatives,1,4,6,9,11,14,16,19-tetraoxocycloeicosane ($L^1$) and 5,10,15,20,-tetramethyl-1,4,6,9,11,14,16,19-tetraoxocycloeicosane ($L^2$), were prepared and the electrode characteristics were tested. The conditioned $NH_4^+$-ISEs (E1) based on $L^1$ with TEHP as a plasticising solvent mediator gave best results with near-Nernstian slope of 53.9 mV/decade of activity, detection limit of $10^{-4.9}$ M, and enhanced selectivity coefficients for the $NH^+_4$ ion with respect to an interfering $K^+$ ion (log $K^{pot}_{NH_4^+,K^+}$ = -1.84). This result was compared to other ammonium ionophores reported previously, for example, that of nonactin (log $K^{pot}_{NH_4^+,K^+}$ = -0.92). The proposed electrode showed no significant potential changes in the range of 3.0 < pH < 9.0.

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (III). Continuous-Automated Determination of Nitrite Ion Using a New Tubular PVC Membrane Type of Selective Electrode Nitrate (溶解氣體 分析用 氣體感應膜 이온選擇性 電極 (第 3 報). 새로운 管形 PVC膜 질산이온 選擇性 電極을 이용한 아질산이온의連續·自動化 定量)

  • Lee Heung Lark;Yun Jong-Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.51-58
    • /
    • 1991
  • A new tubular poly(vinyl chloride) membrane type of nitrate selective electrode was prepared and its characteristics were evaluated. The response slope, detection limit, and response time (t$_{99}$) under the optimum membrane composition (5${\%}$ aliquat-NO$_3$ solution + 32${\%}$ poly(vinyl chloride) + 63${\%}$ dibutyl sebecate) of the electrode were 58.5 ${\pm}$ 0.1 mV/decade, 2.0 ${\times}$ 10$^{-5}$ M, and 25 seconds, respectively. The nitrite ion was determined by the continuous-automated method using the new electrode. 10$^{-2}$ M phosphate buffer solution (pH 7.6) was used as a recipient solution. And also hydrogen peroxide (0.3${\%}$) was added to the recipient as an oxidant. The linear response range and response range and response slope for the standard nitrite solution under the optimum condition of this electrode system were 8.0 ${\times}$ 10$^{-5}$ M ∼ 5.0 ${\times}$ 10$^{-2}$ M and 56.8 ${\pm}$ 0.2 mV/decade, respectively.

  • PDF

A Highly Selective and Sensitive Calcium(II)-Selective PVC Membrane Based on Dimethyl 1-(4-Nitrobenzoyl)-8-oxo-2,8-dihydro-1H-pyrazolo[5,1-a]isoindole-2,3-dicarboxylate as a Novel Ionophore

  • Zamani, Hassan Ali;Abedini-Torghabeh, Javad;Ganjali, Mohammad Reza
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.835-840
    • /
    • 2006
  • Dimethyl 1-(4-nitrobenzoyl)-8-oxo-2,8-dihydro-1H-pyrazolo[5,1-a]isoindole-2,3-dicarboxylate has been used as an ionophore and o-nitrophenyloctyl ether as a plasticizer in order to develop a poly(vinyl chloride)-based membrane electrode for calcium ion detection. The sensors exhibit significantly enhanced response towards calcium(II) ions over the concentration range $8.0{\times}10^{-7}\;1.0{\times}10^{-1}$ M at pH 3.0-11 with a lower detection limit of $5.0 {\times}10^{-7}$ M. The sensors display Nernstian slope of 29.5 ${\pm}$ 0.5 mV per decade for Ca(II) ions. Effects of plasticizers, lipophilic salts and various foreign common ions are tested. It has a fast response time within 10 s over the entire concentration range and can be used for at least 2 months without any divergence in potentials. The proposed electrode revealed good selectivity and response for $Ca^{2+}$ over a wide variety of other metal ions. The selectivity of the sensor is comparable with those reported for other such electrodes. The proposed sensor was successfully applied as an indicator electrode for the potentiometric titration of a Ca(II) solution, with EDTA.