• 제목/요약/키워드: $K^+-ion$ Selective PVC Electrode

검색결과 61건 처리시간 0.021초

Determination of Copper in Black, Red Pepper and the Waste Water Samples by a Highly Selective Sensitive Cu(II) Microelectrode Based on a New Hexadentates Schiff's Base

  • Norouzi, Parviz;Ganjali, Mohammad Reza;Faridbod, Farnoush;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권9호
    • /
    • pp.1439-1444
    • /
    • 2006
  • A $Cu^{2+}$ ion-selective membrane microelectrode has been fabricated from poly vinyl chloride (PVC) matrix membrane containing a new symmetrical hexadentate Schiff,s base 2-{1-(E)-2-((Z)-2-{(E)-2-[(Z)-1-(2-hydroxyphenyl)ethylidene]hydrazono}-1-methylpropylidene)hydrazono]ethyl}phenol (HDNOS) as a neutral carrier, Potassium tetrakis(4-chlorophenyl) borate (KTpClPB) as an anionic excluder and o-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The microelectrode displays linear potential response in the concentration range of $1.0\;{\times}\;10^{-5}-1.0\;{\times}\;10^{-11}$ M of $Cu^{2+}$. The microelectrode exhibits a nice Nernstian slope of 25.9 ${\pm}$ 0.3 mV $decade^{-1}$ in the pH range of 3.1-8.1. The sensor has a relatively short response time in whole concentration ranges ($\sim$5 s). The detection limit of proposed sensor is $5.0\;{\times}\;10^{-12}$ M (320 pg/L), and it can be used over a period of eight weeks. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of $Cu^{2+}$ with EDTA. The proposed membrane electrode was used for the direct determining of $Cu^{2+}$ content in black and red pepper, and in waste water samples.

캘릭스 [4]크라운 유도체를 이온선택성 물질로 사용한 세슘이온 선택성 막전극 (Cesium Ion-Selective Electrode Based on Upper-rim Calix[4]crown Ionophore)

  • 남궁미옥;임혜재;백경수;윤영자
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.428-432
    • /
    • 2000
  • 새로운 캘릭스[4]크라운 화합물을 이온 선택성 물질로 사용하고 지지체로 PVC(polyvinyl chloride), 가소제로 DOS(dioctyl sebacate)를 사용하여 이온선택성 막전극을 제작 하였다. 제작한 막전극을 지시전극으로 사용하여 알칼리, 알칼리토금속 이온에 대하여 각각의 감응전위를 측정한 결과, pH7.20 Tris buffer에서 $10^{-5}-10^{-1}M$ 농도의 변화에 따른 $Cs^+$이온의 감응전위가 이론적인 Nernst식 기울기에 가까운 52.3 mV/decade로 직선성이 잘 성립하는 감응전위를 나타내었다. $Cs^+$이온 농도변화에 따른 막의 감응시간은 $t_{90%}$=10sec이었고, 막의 사용기간은 2개월 정도이다.

  • PDF

(Phenol-Formaldehyde-Aniline 중합체)-Nickel(Ⅱ) Nitrate 구조에 관한 연구 (Structural Characters of (Phenol-Formaldehyde-Aniline Polymer)-Nickel(Ⅱ) Nitrate)

  • 신두순;박봉근
    • 대한화학회지
    • /
    • 제32권5호
    • /
    • pp.409-415
    • /
    • 1988
  • In this study, an aniline modified Bakelite-A resine was synthesized by polymerizing phenol, formaldehyde and aniline. Structural properties of the polymer were examined by IR spectroscopy, elemental analysis and vapour pressure osmometry. By visible spectroscopy, it was found that nitrogens of amine groups in the polymer are strongly coordinated to Ni(Ⅱ). Also a nitrate ion-selective PVC membrane electrode based on the polymer-Ni(Ⅱ) complex as ion carrier was preparaed. The electrode gave a linear response with a Nernstian slope within the concentration range $10^{-1}$ M∼$10^{-4}$M $KNO_3$.

  • PDF

ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링 (Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System)

  • 한희조;김학진;정대현;조우재;조영열;이공인
    • 생물환경조절학회지
    • /
    • 제29권2호
    • /
    • pp.141-152
    • /
    • 2020
  • 본 연구는 양액 내 존재하는 다량 영양소의 농도를 실시간으로 측정하기 위해 이온 선택 전극 (ISE) 으로 구성된 임베디드 시스템의 개발을 보여준다. NO3, K 및 Ca 이온을 감지하기위한 PVC ISE, H2PO4를 감지하기위한 코발트 전극, 기준 전극, 샘플 용액이 담기는 챔버, 펌프 및 밸브를 사용하여 측정하는 시스템으로 구성된다. 양액 샘플양 조절과 데이터 수집을 위해서 데이터 Due 보드가 사용되었고, 각각의 샘플 측정 전에, 측정 중 발생하는 드리프트를 최소화시키기 위해 2 점 정규화 방법을 사용하였다. PVC 멤브레인을 기반으로 한 NO3 및 K 전극의 농도 예측 성능은 표준 분석기의 결과와 근접한 일치 (R2 = 0.99) 나타내며 만족스러운 결과를 나타냈다. 하지만, Ca II 이온 투과체 제조된 Ca 전극은 고농도 양액 농도에서 Ca 농도를 55 %로 낮게 측정하였다. 코발트 전극 기반 인산 측정은 반복측정 중에 발생한 코발트 전극의 불안정한 신호로 인해 표준 방법과 비교하여 45 ~ 155 mg / L의 인산 농도 범위에서 24.7 ± 9.26 %의 비교적 높은 오차를 나타냈다. 수경 P 감지의 예측 능력을 향상시키기 위해 코발트 전극의 신호 컨디셔닝에 대한 추가 연구가 필요함으로 판단된다.

새로운 캘릭스[4]아렌 유도체를 이용한 $Pb^{2+}$ 이온 친화성 막전극 (The $Pb^{2+}$ Ion Affinitive Membrane Electrode Based on New Calix[4]arene Ionophore)

  • 김은진;김민규;남궁미옥;백경수;윤영자
    • 대한화학회지
    • /
    • 제42권5호
    • /
    • pp.531-538
    • /
    • 1998
  • 캘릭스[4]아렌 유도체(호스트 1)를 이온선택성 물질로 사용하고, 지지체로 poly(vinyl chloride)(PVC), 가소제로 dioctylsebacate(DOS)를 사용하여 이온 선택성 막전극을 제작하였다. 호스트 1 막전극을 지시전극으로 사용하여 알칼리, 알칼리 토금속 양이온 그리고 전이 금속 양이온에 대하여 각각의 감응전위를 측정한 결과, 바탕 전해질이 탈 이온수 일때 $Pb^{2+}$의 감응전위가 $1.0 \times10^-6M~1.0 \times 10^-1 M$ 농도 범위에서 이론적인 Nernstian 감응전위 기울기에 가까운 26.5mV/decade를 보여 주었다. 또한 pH 영향을 조사해 본 결과 pH 4.00∼12.00 범위에서 감응전위값이 일정하게 유지되었다. 따라서 본 연구에서 제작된 호스트 1 막전극은 탈이온수 상에서 $Pb^{2+}$에 친화성을 갖는 이온 막전극으로 나타났다.

  • PDF

Improved Thiocyanate-Selective Electrode Based on Tetra(trimethylphenyl)-porphyrinato Manganese(III) Chloride: The Electronic and pH Effects

  • Seo, Hyung-Ran;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권10호
    • /
    • pp.1484-1488
    • /
    • 2004
  • The thiocyanate-selective PVC membrane electrodes based on 5,10,15,20-tetrakis(2,4,6-trimethylphenyl)-porphyrinatomanganese(III) chloride [Mn(TMP)Cl] and 5,10,15,20-tetrakis(2,6-dichlorophenyl)porphyrinatomanganese(III) chloride $[Mn(Cl_8TPP)Cl]$ as ion carriers were investigated. The effect of ionophores, membrane compositions, plasticizers, and solution pHs on the response characteristics were studied. The Mn(TMP)Cl as an ionophore shows the best potentiometric sensitivity with a slope of -58.7 mV/decade and a detection limit of $log[SCN^-]$ = -6.90, and selectivity for thiocyanate over strong hydrophobic interfering anions such as ${ClO_4}^-$ and salicylate. The potentiometric response is affected by the electronic effect of the substituents and solution pHs. The presence of substituents with electron donating and more liphophilic characters around the ligated metal center produces an improved response toward $SCN^-$.

중성운반체를 이용한 리튬이온 선택 전극 (Lithium Ion Selective Electrode Based on a Synthetic Neutural Carrier)

  • 김재상
    • 분석과학
    • /
    • 제5권1호
    • /
    • pp.33-39
    • /
    • 1992
  • 리튬이온의 새로운 중성운반체로서 tetrahydrofuran 단위의 16고리형 crown-4를 퓨란과 아세톤으로부터 산 촉매하에서 합성하여 수소화시킨 후 리튬-이온과의 착물형성반응을 Li-7 NMR과 전기전도도법으로 조사했다. 합성한 리간드를 PVC-액체막 전극에 사용하여 분리용액법에 의한 리튬이온의 선택성을 결정하였다. 막용매, tris(2-ethylhexyl) phosphate에서 리튬이온의 선택계수는 알칼리금속이온 및 알칼리토금속이온에 대해 $2.4{\times}10^{-1}$에서 $2.3{\times}10^{-4}$ 범위의 값을 가졌으며, 산성용액(pH=2 이하, 0.1M LiCl)에서 액체막은 $H^+$ 이온의 방해로 불안정하였다.

  • PDF

Tetrahydrofuran-Containing Crown Ethers as Ionophores for NH+4-Selective Electrodes

  • Jin, Hua-Yan;Kim, Tae-Ho;Kim, Jin-Eun;Lee, Shim-Sung;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권1호
    • /
    • pp.59-62
    • /
    • 2004
  • The ammonium ion-selective electrodes ($NH^+_4$-ISEs) based on the tetrahydrofuran(THF)-containing-16-crown-4 derivatives,1,4,6,9,11,14,16,19-tetraoxocycloeicosane ($L^1$) and 5,10,15,20,-tetramethyl-1,4,6,9,11,14,16,19-tetraoxocycloeicosane ($L^2$), were prepared and the electrode characteristics were tested. The conditioned $NH_4^+$-ISEs (E1) based on $L^1$ with TEHP as a plasticising solvent mediator gave best results with near-Nernstian slope of 53.9 mV/decade of activity, detection limit of $10^{-4.9}$ M, and enhanced selectivity coefficients for the $NH^+_4$ ion with respect to an interfering $K^+$ ion (log $K^{pot}_{NH_4^+,K^+}$ = -1.84). This result was compared to other ammonium ionophores reported previously, for example, that of nonactin (log $K^{pot}_{NH_4^+,K^+}$ = -0.92). The proposed electrode showed no significant potential changes in the range of 3.0 < pH < 9.0.

溶解氣體 分析用 氣體感應膜 이온選擇性 電極 (第 3 報). 새로운 管形 PVC膜 질산이온 選擇性 電極을 이용한 아질산이온의連續·自動化 定量 (Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (III). Continuous-Automated Determination of Nitrite Ion Using a New Tubular PVC Membrane Type of Selective Electrode Nitrate)

  • 이흥락;윤종훈
    • 대한화학회지
    • /
    • 제35권1호
    • /
    • pp.51-58
    • /
    • 1991
  • 새로운 管形 PVC膜 질산이온 選擇性 電極을 제작하여 그 性能을 조사하였다. 電極膜의 組成을 5${\%}$ aliquat-NO$_3$ 용액+ 32${\%}$ poly(vinyl chloride) + 63${\%}$ dibutyl sebecate로 하였을 때 전극의 感應特性이 최적이었으며, 이 때의 감응기울기는 58.5 ${\pm}$ 0.1 mV/decade, 檢出限界는 0.02mM, 感應時間 (t$_{99}$)은 25초이었다. 이 전극을 써서 아질산이온을 連續${\cdot}$自動化法으로 정량하였다. Recipient 용액은 pH 7.6의 10$^{-2}$ M 燐酸鹽 緩衝溶液을 쓰고, 여기에 酸化劑로서 過酸化水素를 0.3${\%}$가 되도록 포함시켰다. 전극계의 最適條件에서 아질산이온 標集溶液 8.0 ${\times}$ 10$^{-5}$ M ∼ 5.0 ${\times}$ 10$^{-2}$ M의 범위에서 직선적인 감응을 나타내었으며, 이 때의 감응기울기는 56.8 ${\pm}$ 0.2 mV/decade이었다.

  • PDF

A Highly Selective and Sensitive Calcium(II)-Selective PVC Membrane Based on Dimethyl 1-(4-Nitrobenzoyl)-8-oxo-2,8-dihydro-1H-pyrazolo[5,1-a]isoindole-2,3-dicarboxylate as a Novel Ionophore

  • Zamani, Hassan Ali;Abedini-Torghabeh, Javad;Ganjali, Mohammad Reza
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권6호
    • /
    • pp.835-840
    • /
    • 2006
  • Dimethyl 1-(4-nitrobenzoyl)-8-oxo-2,8-dihydro-1H-pyrazolo[5,1-a]isoindole-2,3-dicarboxylate has been used as an ionophore and o-nitrophenyloctyl ether as a plasticizer in order to develop a poly(vinyl chloride)-based membrane electrode for calcium ion detection. The sensors exhibit significantly enhanced response towards calcium(II) ions over the concentration range $8.0{\times}10^{-7}\;1.0{\times}10^{-1}$ M at pH 3.0-11 with a lower detection limit of $5.0 {\times}10^{-7}$ M. The sensors display Nernstian slope of 29.5 ${\pm}$ 0.5 mV per decade for Ca(II) ions. Effects of plasticizers, lipophilic salts and various foreign common ions are tested. It has a fast response time within 10 s over the entire concentration range and can be used for at least 2 months without any divergence in potentials. The proposed electrode revealed good selectivity and response for $Ca^{2+}$ over a wide variety of other metal ions. The selectivity of the sensor is comparable with those reported for other such electrodes. The proposed sensor was successfully applied as an indicator electrode for the potentiometric titration of a Ca(II) solution, with EDTA.