• 제목/요약/키워드: $K^+-ion$ Selective PVC Electrode

검색결과 61건 처리시간 0.021초

Sub-Micro Molar Monitoring of La3+ by a Novel Lanthanum PVC-Based Membrane Sensor Based on 3-Hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide

  • Ganjali, Mohammad Reza;Norouzi, Parviz;Yousefian, Nasrin;Faridbod, Farnoush;Adib, Mehdi
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권10호
    • /
    • pp.1581-1586
    • /
    • 2006
  • A La (III) ion-selective membrane sensor has been fabricated from poly vinyl chloride (PVC) matrix membrane, containing 3-hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide (HPMN) as a neutral carrier, potassium tetrakis (p-chlorophenyl) borate (KTpClPB) as an anionic excluder and ortho-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The effects of membrane composition and pH as well as the influence of the anionic additive on the response properties were investigated. The sensor with 30% PVC, 62% solvent mediator, 6% ionophore and 2% anionic additive, shows the best potentiometric response characteristics. It displays a Nernstian behavior (19.2 mV per decade) across the range of $1.0{\times}10^{-2}-1.0{\times}10^{-7}$ M. The detection limit of the electrode is $7.0{\times}10^{-8}$ M ($\sim$10 ng/mL) and the response time is 15 s from $1.0{\times}10^{-2}$ up to $1.0{\times}10^{-4} $M and 30 s in the range of $1.0 {\times}10^{-5}-1.0{\times}10^{-7}$ M. The sensor can be used in the pH values of 3.0-9.0 for about seven weeks. The membrane sensor was used as an indicator electrode in the potentiometric titration of lanthanum ions with EDTA. It was successfully applied to the lanthanum determination in some mouth wash preparations.

Potentiometric Sensor for the Determination of Dibucaine in Pharmaceutical Preparations and Electrochemical Study of the Drug with BSA

  • Ensafi, Ali A.;Allafchian, A.R.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2722-2726
    • /
    • 2011
  • Plasticized poly(vinyl chloride), PVCs, with different membrane compositions tested for use in the construction of an ion-selective sensor for the determination dibucaine. A prepared membrane with dioctyl phthalate-PVC and ion-pair of N-(1-naphthyl)ethylenediamine dihydrochloride-tetraphenyl borate had a good potential to acts as a potentiometric sensor for the analysis of dibucaine. A linear relationship was obtained between potential and logC varying between $1.0{\times}10^{-6}$ and $1.0{\times}10^{-2}$ M dibucaine with a good repeatability and reproducibility. The sensor was applied for the determination of the drug in pharmaceuticals and biological fluids such as plasma and urine samples with satisfactory results. The drug electrode has also been used to study the interaction of bovine serum albumin (BSA) with dibucaine. The saturated quantities of dibucaine binding were 13.04, 5.30 and 9.70 mol/mol in 0.01, 0.02 and 0.1% of protein, respectively.

Organopalladium(II) Complexes as Ionophores for Thiocyanate Ion-Selective Electrodes

  • Kim, Dong-Wan;Lee, So-Hyun;Kim, Jung-Hwan;Kim, Jin-Eun;Park, Jong-Keun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권10호
    • /
    • pp.2303-2308
    • /
    • 2009
  • A thiocyanate poly(vinyl chloride) (PVC) membrane electrode based on [1,2-bis(diphenylphosphino)ethane]dihalopalladium( II), [(dppe)$PdX_2$, X = Cl ($L^1$), X = I ($L^2$)] as active sensor has been developed. The diiodopalladium complex, [(dppe)$PdI_2](L^2$) displays an anti-Hofmeister selectivity sequence: $SCN^-\;>\;I^-\;>\;{ClO_4}^-\;>\;Sal^-\;>\;Br^-\;>\;{NO_2}^-\;>\;{HPO_4}^-\;>\;AcO^-\;>\;{NO_3}^-\;>\;{H_2PO_4}^-\;>\;{CO_3}^{2-}$. The electrode exhibits a Nernstian response (-59.8 mV/decade) over a wide linear concentration range of thiocyanate ($(1.0\;{\times}\;10^{-1}\;to\;5.0\;{\times}\;10^{-6}$ M), low detection limit ($(1.1\;{\times}\;10^{-6}$ M), fast response $(t_{90%}$ = 24 s), and applicability over a wide pH range (3.5∼11). Addition of anionic sites, potassium tetrakis[p-chlorophenyl] borate (KTpClPB) is shown to improve potentiometric anion selectivity, suggesting that the palladium complex may operate as a partially charged carrier-type ionophore within the polymer membrane phase. The reaction mechanism is discussed with respect to UV-Vis and IR spectroscopy. Application of the electrode to the potentiometric titration of thiocyanate ion with silver nitrate is reported.

Development of a Fluoride-Selective Electrode based on Scandium(III) Octaethylporphyrin in a Plasticized Polymeric Membrane

  • Kang, Young-Jea;Lutz, Christopher;Hong, Sung-A;Sung, Da-Yeon;Lee, Jae-Seon;Shin, Jae-Ho;Nam, Hak-Hyun;Cha, Geun-Sig;Meyerhoff, Mark E.
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권6호
    • /
    • pp.1601-1608
    • /
    • 2010
  • A scandium(III) porphyrin-based fluoride-selective potentiometric sensor and its application in the analysis of hydrofluoric acid is described. Scandium(III) octaethylporphyrin, an ionophore recently developed for the optical fluoride sensor, was employed as a host molecule for the selective binding with fluoride in the plasticized PVC membrane. Nernstian response for $F^-$ between $10^{-4.6}$ to $10^{-1}$ M was observed at a glycine-phosphate buffer (pH 3.0). The selectivity pattern was observed as $F^-$, salicylate $\gg$ $SCN^-$ > $Cl^-$, $Br^-$, $NO_3{^-}$, $ClO_4{^-}$, which is consistent with the binding constant data measured in the plasticized PVC membrane based on a sandwich membrane method. This highly selective and reversible fluoride-sensitive electrode was employed for the analysis of hydrofluoric acid (HF). A disposable differential-type HF sensor was fabricated on the screen-printed electrode and demonstrated its ability to detect the neutral HF in the acidic solution.

Salphen H2 as a Neutral Carrier for the Uranyl Ion-Selective PVC Membrane Sensor

  • Kim, Dong-Wan;Park, Kyeong-Won;Yang, Mi-Hyi;Kim, Jin-eun;Lee, Shim-Sung;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권6호
    • /
    • pp.899-902
    • /
    • 2006
  • The complexation of N,N'-4,5-(ethylenedioxy)benzenebis(salicylideneimine), (salphen$H_2$) with uranyl ion was studied in acetonitrile solution spectrophtometrically, and the formation constant of the resulting 1 : 1 complex was evaluated. The salphen$H_2$ ligand was used as an ionophore in plasticized poly(vinyl chloride) (PVC) matrix membrane sensor for uranyl ion. The prepared sensors exhibited a near Nernstian response, 28.0-30.9 mV/decade for uranyl ion over the concentration range $1.0\;{\times}\;10^{-2}$ to $1.0\;{\times}\;10^{-6}$M with a limit of detection of $3.2\;{\times}\;10^{-7}$ M. The proposed electrode could be used at a working pH range of 1.5 - 4.0.

Alverine의 정량을 위한 Ion-Selective Electrodes (Ion-Selective Electrodes for the Determination of Alverine)

  • 이은엽;김기묘;김성진;허문희;안문규
    • 분석과학
    • /
    • 제8권1호
    • /
    • pp.79-84
    • /
    • 1995
  • Alverine에 대한 anionic counter ion으로서 acid red 97의 이용 가능성을 살펴보았다. PVC와 가소제의 비율이 같을 때 적절한 감응과 긴 수명을 나타내었으며, 검량선은 $1.0{\times}10^{-5}M$까지 직선성이었고 그 감응 기울기는 55.35mV/dec., 변동계수는 0.61이었다. Methylephedrine에 대하여는 -2.626, histidine에 대하여는 -2.216등의 선택계수를 보였고 pH 7.0~4.0에서 안정된 전위값을 얻을 수 있었다. $10^{-4}M$ 이하에서 20~30초 이내, 그 이상의 농도에서는 약 10초 이내에서 안정된 전위값을 얻을 수 있었다.

  • PDF

안트라센을 포함하는 15-Crown-5 유도체를 이온선택성 물질로 이용한 칼륨이온의 전위차법 정량 (Potentiometric Determination of Postssium Ion Using 15-Crown-5 Derivatives with Anthracene for the Selective Material)

  • 배준용;이상봉;장승현;김의락
    • 대한화학회지
    • /
    • 제45권1호
    • /
    • pp.31-39
    • /
    • 2001
  • 새로이 합성한 15-Crown-5 유도체들을 칼륨이온의 전위차법 정량을 위한 중성운반체로 사용하였다. 다섯 가지 화합물 중에서N-(4'-benzo-15-crown-5-ether)-anthracene-9-imine이 가장 좋은 선택성과 안정성을 보였다. 칼륨이온을 전위차법으로 정량하기 위한 이온선 택성 막의 조성을 조사한 결과, 최적 조성은 중성운반체: PVC:가소제의 조성비가 1.0:33.0:66.0 wt% 이었다. 친유성 첨가제로 0.2wt% KTpClPB를 사용했을 때에 Nernstian 기울기가 많이 좋아졌고, 또 알칼리 및 알칼리 토류 금속에 대한 칼륨이온의 선택성이 크게 개선되었다. 특히 암모늄이온에 대한 칼륨 이온의 선택성은 $logK^{pot}_(K^+,NH_4^+}$=-2.59로 아주 좋은 값을 보였다. 이 전극의 감응시간은 $t_{100}$=5sec로서 짧은 시간에 많은 시료를 분석할 수 있고, 3주 이상 사용하여도 선택성과 분석 특성에 별다른 변화가 없었다.

  • PDF

AC 임피던스 분석법을 이용한 K+ 이온선택성 PVC막 전극 특성 (Electrode Characteristics of K+ Ion-Selective PVC Membrane Electrodes with AC Impedance Spectrum)

  • 김용렬;안형환;강안수
    • 공업화학
    • /
    • 제9권6호
    • /
    • pp.870-877
    • /
    • 1998
  • 본 연구에서는 임피던스 스펙트럼 분석법을 사용하여 중성운반체로 dibenzo-18-crown-6 (D18Cr6)와 valinomycin (Val)을 이용하여 $K^+$이온선택성 PVC막 전극의 막과 용액계면에서의 임피던스 특성을 검토하였다. PVC막에 대한 운반체의 종류와 함량, 가소제, 막두께, 기본전해질의 혼입(doping)여부 및 이온의 농도변화 등을 교류임피던스 분석법을 이용하여 측정하였고, 그 결과를 전극특성과 비교 검토하고 PVC막 전극에서의 전달특성을 규명하였다. 교류 임피던스의 특성을 측정하여 중성운반체로 D18Cr6와 Val을 포함하고 있는 PVC막 전극의 등가회로는 막의 벌크저항과 전기이중층 용량을 포함하는 기하학적용량을 병렬로 하고, 용액저항과 직렬로 구성되는 임피던스의 등가회로임을 확인할 수 있었다. 그러나 저농도 및 저주파수 영역에서 약간의 전하전이저항과 Warburg저항이 나타나 중첩되는 것을 알 수 있었다. $K^+$이온선택성 전극에서 운반체로서 D18Cr6가 Val중 D18Cr6가 기존의 Val보다 전극특성 및 임피던스 특성이 좋았으며 특히 D18Cr6에 기본전해질로 potassium tetraphenylborate (TPB)를 첨가한 경우 이상적인 전극을 제조할 수 있었다. 운반체의 최적 함량은 D18Cr6와 Val의 경우 3.23wt%부근이었고, 가소제는 DBP가 가장 적절하였다. 막두께가 얇아질수록 임피던스 특성이 좋아졌으나, 막두께가 최적 막두께 이하로 얇아지면 전극특성이 나빠짐을 알 수 있었다. D18Cr6의 경우 $K^+$이온에 대한 혼합용액법에 의한 선택계수 서열은 다음과 같았다. $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

The Novel SCN- Ion-selective Electrode Based on the 1-Benzyl-3-(4-nitrophenyl) thio-urea Ionophore

  • Lee, Kyungmi;Kang, Dong Hyeon;Choe, Ju Eun;Yun, Mira;You, Jung-Min;Go, Min Jeong;Lee, Junseong;Jeon, Seungwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권11호
    • /
    • pp.3175-3180
    • /
    • 2014
  • A potentiometric sensor based on the 1-benzyl-3-(4-nitrophenyl) thio-urea was synthesized and tested as an ionophore in PVC based membrane sensor towards $SCN^-$ ions. This membrane exhibits a linear stable response over a wide concentration range ($1.0{\times}10^{-5}$ to $1.0{\times}10^{-2}M$) with a slope of -59.2 mV/dec., a detection limit of ${\log}[SCN^-]=-5.05$, and a selectivity coefficient for thiocyanate against perchlorate anion of ${\log}K^{pot}_{SCN^-j}=-0.133$. The selectivity series of the membrane is as follows: $SCN^-$ > $ClO_4{^-}$ > $I^-$ > $NO_3{^-}$ > $HSO_3{^-}$ > $Cl^-$ > $HSO_4{^-}$ > $F^-$ > $CH_3COO^-$ > $HCO_3{^-}$ > $Br^-$ > $H_2PO_4{^-}$ > $SO{_3}^{2-}$ > $SO{_4}^{2-}$ > $CO{_3}^{2-}$. The proposed electrode showed good selectivity and a good response for the $SCN^-$ ion over a wide variety of other anions in pH 6.0 buffer solutions and has a fast response time of about < 5s. The influences of the membrane by pH, ionophore, and plasticizer were studied.

Tetramethylthiuram monosulfide를 ionophore로 이용한 납 이온 선택성 poly(aniline) 고체 접촉 전극 (Lead Ion Selective Solid Contact Electrode based on Tetramethylthiuram monosulfide ionophore)

  • 한원식;박운석;권혜영;이영훈;홍태기
    • 한국응용과학기술학회지
    • /
    • 제30권2호
    • /
    • pp.356-361
    • /
    • 2013
  • Lead (II) ion selective poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore as a sulfur containing sensing material is successfully developed. The electrode exhibits good linear response of 25.6 mV / decade (at $20{\pm}0.2^{\circ}C$, r2=0.995) within the concentration range of $1.0{\times}10^{-1}{\sim}4.0{\times}10^{-7}$ M Pb (II). The composition of this electrode was Ionophore : PVC : dioctylphthalate : potassiumtetrakis(4-chlorophenyl)borate : Oleic acid = 5.0 : 20.0 : 25.0 : 4.0 : 5.0. When we consider the results of using different composition electrodes based on only one potassiumtetrakis(4-chlorophenyl)borate or Oleic acid liphophlic additive, poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore with potassiumtetrakis(4-chlorophenyl)borate and Oleic acid liphophlic additive had the best result in response characteristics. The electrode shows good selectivity for lead (II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. This electrode is suitable for use with aqueous solutions of pH 3.0 ~ 7.0 and their standard deviation in the measured emf differences was ${\pm}2.94$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-2}$ M and ${\pm}2.82$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-3}$ M. Their stabilization time was less than 710 s. and response time was less than 16 s.