• 제목/요약/키워드: $K^+-ion$ Selective PVC Electrode

검색결과 61건 처리시간 0.019초

Bakelite A-Ni(II) 착물의 질산이온 선택성 막전극 (Nitrate Ion-Selective Membrane Electrode Based on Complex of Ammonia Modified Bakelite A-Ni(II) Nitrate)

  • 김환기;신두순
    • 대한화학회지
    • /
    • 제31권3호
    • /
    • pp.271-279
    • /
    • 1987
  • Amine기를 가진 Bakelite A와 Ni(II) 사이의 착물을 이용한 ${NO_3}^-$이온 선택성 막전극을 만들었다. 이 막전극은 $H^+$ 이온 및 2가 3가 음이온에는 감응하지 않으며, 특히 이 막전극의 재현성, 감응시간 및 이온선택성등 전기화학적 성질을 조사하여 다른 실용화된 막전극과 비교 고찰하였으며 분석화학에의 응용을 고찰하였다.

  • PDF

Novel Silver(I) Ion Selective PVC Membrane Electrode Based on the Schiff Base (N2E,N2'E)-N2,N2'-Bis(Thiophen-2-ylmethylene)-1,1'-Binaphthyl-2,2'-Diamine

  • Jeong, Eunseon;Ahmed, Mohammad Shamsuddin;Jeong, Hae-Sang;Lee, Eun-Hee;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.800-804
    • /
    • 2011
  • A potentiometric sensor based on the Schiff base $(N^2E,N^{2'}E)-N^2,N^{2'}$-bis(thiophen-2-ylmethylene)-1,1'-binaphthl-2,2'-diamine has been synthesized and explored as an ionophore PVC-based membrane sensor selective for the silver ($Ag^+$) ion. Potentiometric investigations indicate a high affinity of this receptor for the silver ion. Seven membranes have been fabricated with different compositions, with the best performance shown by the membrane with an ionophore composition (w/w) of: 1.0 mg, PVC: 33.0 mg, DOA: 66.0 mg in 1.0 mL THF. The sensor worked well within a wide concentration range of $1.0{\times}10^{-2}$ to $1.0{\times}10^{-7}$ M, at pH 5, at room temperature (slope 57.4 mV/dec.), and with a rapid response time of 9 s; the sensor also showed good selectivity towards the silver ion over a huge number of interfering cations, with the highest selectivity coefficient for $Hg^{2+}$ at -3.7. Thus far, the best lower detection limit was $4.0{\times}10^{-8}$ M.

폴리우레탄을 메트릭스로한 액막형 칼륨이온 선택성 전극의 제조 및 특성 (Characteristics and Preparation of Potassium Ion Selective Liquid Membrane Electrode Based on Polyurethane Matrix)

  • 유광식;이용탁;강철용
    • 대한화학회지
    • /
    • 제35권2호
    • /
    • pp.128-134
    • /
    • 1991
  • 기존 칼륨이온 선택성 전극의 메트릭스로는 대체로 PVC가 사용되어졌으나, 본 연구에서는 폴리우레탄을 사용하였고, 용매 매개체로는 2-nitropheny-n-alkylate, 감응물질로는 potassium tetraphenyl borate 및 D-18-Crown-6 등을 써서 전극막을 제조하였다. 본 폴리우레탄 메트릭스의 칼륨이온 선택성전극의 수명은 75일로서 PVC 메트릭스의 칼륨이온 선택성 전극에 비하여 한층 더 길었다. 전극전위응답(slope factor)은 직선응답범위(K$^+$ 농도 : $1{\times}10^{-1}\;{\sim}\;1{\times}10^{-4}$ M)내에서 52 mV/decade이었고, 본 전극은 방해이온들 $(NH^{4+},\;Na^{+},\;Li^{+},\;Ca^{2+},\;Mg^{2+},\;Cu^{2+}$)이 존재하는 해수 중의 칼륨이온을 B(Ph)$_4^-$ 표준용액으로 전위차 적정시 종말점을 검출하는데 성공적으로 적용되었다.

  • PDF

Surface Renewable Hydrogen Ion-Selective Polymeric Composite Electrode Containing Iridium Oxide

  • Quan, Hongmei;Kim, Won;Chung, Koo-Chun;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권10호
    • /
    • pp.1565-1568
    • /
    • 2005
  • A surface renewable pH electrode was prepared by utilizing composite electrode technique. Iridium oxide micro-fine particles was prepared by hydrolysis of $(NH_4)_2IrCl_6$ at elevated temperature. The iridium oxide particles were mixed with well-dispersed carbon black and then filtered. The mixture was suspended in DMF containing PVC as a binder. The mixture was precipitated rapidly by adding large amount of water. The precipitate was ground and pressure-molded to iridium oxide composite electrode material. The electrode showed linear response between pH 1-13 with 50 to 60 mV/pH slope. The electrode maintained the pH response without appreciable slope drift for 170 days if stored in deionized water. The electrode surface can be renewed reproducibly by simple grinding process whenever contaminated or deactivated.

Optimal Immobilization of Penicillinase for Ion-selective Electrode

  • Hur, Moon-Hye;Kang, Hee-Jin;Min, Hye-Young;Lee, Ji-Yeun;Lee, Ki-Hyun;Ahn, Moon-Kyu
    • Archives of Pharmacal Research
    • /
    • 제20권1호
    • /
    • pp.68-71
    • /
    • 1997
  • Penicillin sensor was prepared by immobilizing penicillinase (Pcase) on $H^{+}$-selective carboxylated poly (vinyl chloride) (PVC-COOH) membrane or cellulose filter membrane. The immobilization techniques are as follows. Pcase was immobilized with GTH on $H^{+}$-selective PVC-COOH membrane or some amount of BSA was dropped on that membrane. Another method to make immobilization is to mix type I Pcase with GTH and drop on a cellulose filter membrane. According to immobilization techniques, there were some differences in response properties of enzyme electrodes, however, all electrodes responded to Pcase-resistant penicillin derivatives. Pcase immobilized on cellulose filter membrane with $H^{+}$-selective PVC membrane eletrode was more stable and more sensitive to penicillinase-resistant penicillin derivatives than any other immobilization techniques.

  • PDF

Silicone Rubber Blended with Polyurethane as the Matrix for Ion-Selective Membrane Electrodes

  • Lee, Hyun Jung;Rho, Kyung Lae;Kim, Chang Yong;Oh, Bong Kyun;Cha, Geun Sig;Nam, Hakhyun
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.623-630
    • /
    • 1995
  • Silicone rubber-based sodium-selective membranes are developed for solid-state ion sensors. It was shown that the potetiometric performance of SR-based membranes are greatly dependent on the type of neutral carriers employed; among the three ionophores, N,N,N',N'-tetracyclohexyl-1,2-phenylenedioxydiacetamide (ETH 2120), bis[(12-crown-4)methyl]dodecylmethylmalonate (D12C4DMM) and monensin methyl ester (MME), examined, only ETH 2120 was compatible with the SR-based matrix. Addition of about 20 wt% plasticizer to the SR-based matrix provided the resulting membranes with potentiometric properties essentially equivalent to those of the corresponding PVC-based membranes. Owing to the strong adhesive strength of SR-based membranes, the CWEs coated \vith those membranes exhibited long lifetime with conventional electrode-like performance. Blending of PU into the SR matrix increased the lifetime of CWEs from two weeks to one month.

  • PDF

Copper(II) Selective PVC Membrane Electrodes Based on Schiff base 1,2-Bis (E-2-hydroxy benzylidene amino)anthracene-9,10-dione Complex as an Ionophore

  • Jeong, Eun-Seon;Lee, Hyo-Kyoung;Ahmed, Mohammad Shamsuddin;Seo, Hyung-Ran;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권2호
    • /
    • pp.401-405
    • /
    • 2010
  • The Schiff base 1,2-bis(E-2-hydroxy benzylidene amino)anthracene-9,10-dione has been synthesized and explored as ionophore for preparing PVC-based membrane sensors selective to the copper ($Cu^{2+}$) ion. Potentiometric investigations indicate high affinity of these receptors for copper ion. The best performance was shown by the membrane of composition (w/w) of ionophore: 1 mg, PVC: 33 mg, DOP: 66 mg and KTpClPB as additive were added 50 mol % relative to the ionophore in 1 ml THF. The proposed sensor's detection limit is $2.8{\times}10^{-7}$ M over pH 5 at room temperature (Nernstian slope 31.76 mV/dec.) with a response time of 15 seconds and showed good selectivity to copper ion over a number of interfering cations.

Highly Copper(II)-selective PVC Membrane Based on a Schiff Base Complex of N,N'-Bis-pyridin-2-ylmethylene-naphthalene-1,8-diamine as an Ionophore

  • Jeong, Dae-Cheol;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권10호
    • /
    • pp.1593-1596
    • /
    • 2006
  • The polymeric membrane electrodes based on N,N'-bis-pyridin-2-ylmethylene-naphthalene-1,8-diamine as an ion carrier were prepared and tested for the copper-ion selective electrode. The membrane has a linear dynamic range between $10^{-6}$ and $10^{-2}$ M with a Nernstian slope of 29.6 mV per decade, and its detection limit was $10^{-5.62}$M. The potentiometric response is independent of the pH range of 3-5. The proposed electrode showed good selectivity and response for $Cu^{2+}$ over a wide variety of other metal ions in pH 4.0 buffer solutions.

Pilymeric Membrane Sodium Ion-Selective Electrodes Based on Calix[4}arene Triesters

  • 김윤덕;정해상;강성옥;남계천;전승원
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권4호
    • /
    • pp.405-408
    • /
    • 2001
  • New lipophilic triesters of calix[4]arene and calix[4]quinone are investigated as sodium ion-selective ionophores in poly(vinyl chloride) membrane electrodes. For an ion selective electrode based on calix[4]arene triester I, the linear response is 1 ${\times}$10-3.5 to 1 ${\times}$ 10-1 M of Na+ concentrations. The selectivity coefficients for sodium ion over alkali metal and ammonium ions are determined. The detection limit (logaNa+ = -4.50) and the selectivity coefficient (logKNa+,K+pot = -1.86) are obtained for polymeric membrane electrode containing calix[4]arene triester I.

Lead(II)-selective Polymeric Electrode Using a Schiff Base Complex of N,N'-Bis-thiophene-2-ylmethylene-ethane-1,2-diamine as an Ion Carrier

  • Jeong, Tae-Jun;Jeong, Dae-Cheol;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권8호
    • /
    • pp.1219-1224
    • /
    • 2005
  • We prepared lead ion-selective PVC membranes that were based on N,N'-bis-thiophene-2-ylmethylene-ethane-1,2-diamine as a membrane carrier. The membrane electrode has a linear dynamic range between 1.0 ${\times}$ $10^{-5}$ and 1.0 ${\times}$ $10^{-1}$ M with a Nernstian slope of 29.79 mV per decade, and its detection limit was 2.04 ${\times}$ $10^{-6}$ M at room temperature. The potentiometric response is independent of the pH of the solution in the pH range of 5-7. The proposed electrode revealed good selectivity and response for $Pb^{2+}$ over a wide variety of other metal ions in pH 5.0 buffer solutions, and there was good reproducibility of the base line on the subsequent measurements. The membrane electrode has a relatively fast response time, satisfactory reproducibility and a relatively long life time.