• Title/Summary/Keyword: $K^+-channel$

Search Result 11,815, Processing Time 0.044 seconds

Effect of Thyroid Hormone on the Electrical Activity of Rabbit Heart (토끼심장의 전기적 활동에 대한 갑상선 호르몬의 영향)

  • Hong, Seong-Geun;Kwun, Jong-Kuk;Chung, Soon-Il
    • The Korean Journal of Physiology
    • /
    • v.20 no.1
    • /
    • pp.17-29
    • /
    • 1986
  • The present study was carried out to observe the effect of triiodothyronine on heart, one of the target organ of thyroid hormone. There are many reports that tachycardia, arrythmia, and agumentation of sodium, potassium pump activity are caused in hyperthyroid animal. To examine these cardiac positive chronotropic effects on sinoatrial (SA) node and atrial muscle, hyperthyroid state was induced experimentally by the injecion of 3,3',5-1-triiodothyronine $(T_3)$ in $3{\sim}6$ month-old rabbits. Then intracellular recordings by inserting glass microelectrode into cell were obtained in SA node and atrial muscle. The results can be summarized as follows : 1) Heartbeat was increased from $169.6{\pm}28.0\;to\;264.2{\pm}18.0$ beats per minute, while body weight was decreased to 68f of the initial body weight (Day 1). 2) In experimental group, the duration of action potential at 80% repolarization was decreased from $148.0{\pm}29.1\;to\;107{\pm}13.6msec$. This suggested the increase heartbeat. 3) The firing rate in hyperthyroid group markedly reduced under the 15 mM potassium Tyrode (p<0.005). 4) In hyperthyroid group, depolarization of atrial muscle cell was lowered significantly in 15 mM (p<0.05), 20 mM (p<0.05) potassium Tyrode solution. 5) Sodium-potassium pump activities in experimental group were higher than those in control group in both SA node (p<0. 1) and atrial muscle (p<0.025). 6) In lower concentration of $MnCl_2$, the excitability of SA node in hyperthyroid group was decreased more than that in control group. Effective inhibitory dose $(ID_{50})$ as 0.6 mM in hyperthyroid statd and 1.1 mM in control group.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Tectonic Structures and Hydrocarbon Potential in the Central Bransfield Basin, Antarctica (남극 브랜스필드 해협 중앙분지의 지체구조 및 석유부존 가능성)

  • Huh Sik;Kim Yeadong;Cheong Dae-Kyo;Jin Young Keun;Nam Sang Heon
    • The Korean Journal of Petroleum Geology
    • /
    • v.5 no.1_2 s.6
    • /
    • pp.9-15
    • /
    • 1997
  • The study area is located in the Central Bransfield Basin, Antarctica. To analyze the morphology of seafloor, structure of basement, and seismic stratigraphy of the sedimentary layers, we have acquired, processed, and interpreted the multi-channel seismic data. The northwest-southeastern back-arc extension dramatically changes seafloor morphology, volcanic and fault distribution, and basin structure along the spreading ridges. The northern continental shelf shows a narrow, steep topography. In contrast, the continental shelf or slope in the south, which is connected to the Antarctic Peninsula, has a gentle gradient. Volcanic activities resulted in the formation of large volcanos and basement highs near the spreading center, and small-scale volcanic diapirs on the shelf. A very long, continuous normal fault characterizes the northern shelf, whereas several basinward synthetic faults probably detach into the master fault in the south. Four transfer faults, the northwest-southeastern deep-parallel structures, controlled the complex distributions of the volcanos, normal faults, depocenters, and possibly hydrocarbon provinces in the study area. They have also deformed the basement structure and depositional pattern. Even though the Bransfield Basin was believed to be formed in the Late Cenozoic (about 4 Ma), the hydrocarbon potential may be very high due to thick sediment accumulation, high organic contents, high heat flow resulted from the active tectonics, and adequate traps.

  • PDF

Research on Environmentally-Sound Erosion Control Works(II) -The Management and Guidelines of Riparian Zone in Japan- (환경(環境)과 조화한 사방사업(砂防事業)(II) -일본(日本)에 있어서 수변지역(水邊地域)의 관리(管理)와 지침(指針)-)

  • Chun, Kun-Woo;Kim, Kyoung-Nam;Seomun, Won;Yeom, Kyu-Jin;Ezaki, Tsugio
    • Journal of Forest and Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.112-127
    • /
    • 1998
  • A meeting for Japan Society of Erosion Control Engineering took place, from May 20-21 in Sapporo, Japan, with the presentations of 21 special topics and 185 general papers. Special topics consists of 6 copies on volcanic disaster prevention, 6 copies on the activity report of Earthquake Erosion Control Engineering Society, 5 copies on the management and guidelines of riparian zone and 4 copies on debris disaster occurred in 1997. General papers consists of 10 copies on slope stability, 10 copies on slope failure, 9 copies on earthquake, 41 copies on environmental erosion control, 25 copies on debris flow, 11 copies on warning and refuge, 10 copies on erosion control plan, 11 copies on erosion control project, 10 copies on erosion control facility, 12 copies on volcanic erosion control, 4 copies on revegetation technology, 4 copies on forest hydrology, 4 copies on avalanche, 4 copies on landslide, 18 copies on debris flow and 2 other copies presented by international student. Among the special topics, 5 papers with the titles of the function and structure of riparian zone, the interactive relation of flood and riparian zone, the management method of channel and river forest for controlling debris flow, the forest restoration efforts by native population, the law and social issue for building river riparian zone were presented in the subsection of "The Management and Guidelines of Riparian Zone". Thus, this article summarize and introduce the presented contents which are very important and can be referred to keep environmentally sound-river in the erosion control field.

  • PDF

Characteristics of Pockmark Topography in Hupo Basin, East Sea (동해 후포분지의 Pockmark 해저지형 특성 연구)

  • Kim, ChangHwan;Park, ChanHong;Lee, MyoungHoon;Choi, SoonYoung;Kim, WonHyuck
    • Economic and Environmental Geology
    • /
    • v.52 no.6
    • /
    • pp.561-571
    • /
    • 2019
  • The Hupo Basin, continental marginal basin, of the East Sea extends to Uljin-gun and Yeongdeok-gun. The Hupo Bank, a terrain that is higher than the surrounding seabed, is located at the eastern boundary of the Hupo Basin. KIOST(Korea Institute of Ocean Science and Technology) conducted detailed bathymetry surveys in the northern, central and southern areas of the Hupo Basin from 2011 to 2013. The Hupo Basin, bounded by steep slopes of the Hupo Bank, is deepened from the west coast to the east and deepest to a maximum depth of about 250 m. A narrow seafloor channel appears in the northern, central, and southern areas with the deepest depths. Numerous pockmarks appear on the seafloor at depths of about 150 ~ 250 m in all the three areas of the detailed bathymetry surveys. These pockmarks generally have diameters of about 20 to 50 m and depths of about 4 to 6 m, with craterlike submarine topography of various sizes. Seafloor sediments in the pockmark areas consist of fine silt. Comparing the shape and size of the pockmark of the Hupo Basin with that of other regions of the world, it is considered to be classified as a normal pockmark. There are about 7 pockmarks/1 ㎢ in the northern part of the three areas and about 8 pockmarks/1 ㎢ in the central part. The southern part has about 5 pockmarks/1 ㎢. If the area with the possibility of pockmarks is extended to the depth area of about 150 ~ 250 m in the entire Hupo Basin, the number of pockmarks is estimated to be more than about 4800. The pockmark of the Hupo Basin is more likely to be generated by a fluid such as a liquid than a gas. But it is necessary to scrutinize the cause and continuously monitor the pockmark.

Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors (삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가)

  • Park, Myung-Hwan;Lee, Jin-Wan;Lee, Kang-Won;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body.

  • PDF

FES Exercise Program for Independent Paraplegic Walking (하반신 마비환자의 FES 독립보행을 위한 근육 강화 프로그램)

  • Khang, Seon-Hwa;Khang, Gon;Choi, Hyun-Joo;Kim, Jong-Moon;Chong, Soon-Yeol;Chung, Jin-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.69-80
    • /
    • 1998
  • This research was designed to investigate how the exercise program affects paraplegic standing and walking employing functional electrical stimulation(FES). Emphasis was also given to fatigue of major lower extremity muscles induced by different types of electrical stimulation. We applied continuous and intermittent rectangular pulse trains to quadriceps of 10 normal subjects and 4 complete paraplegic patients. The frequencies were 20Hz and 80Hz, and the knee angle was fixed at 90$^{\circ}$and 150$^{\circ}$to investigate how muscle fatigue is related to muscle length. The knee extensor torque was measured and monitored. We have been training quadriceps and gastrocnemius of a male paraplegic patient by means of electrical stimulation for the past two year. FES standing was initiated when the knee extensors became strong enough to support the body weight, and then the patient started FES walking utilizing parallel bars and a walker. We used an 8-channel constant-voltage stimulator and surface electrodes. The experimental results indicated that paralyzed muscles fatigued rapidly around the optimal length contrary to normal muscles and confirmed that low frequency and intermittent stimulation delayed fatigue. Our exercise program increased muscle force by approximately 10 folds and decreased the fatigue index to half of the initial value. In addition, the exercise enabled the patient to voluntarily lift each leg up to 10cm, which was of great help to the swing phase of FES walking. Both muscle force and resistance to fatigue were significantly enhanced right after the exercise was applied every day instead of 6 days a week. Up to date, the patient can walk for more than two and half minutes at 10m/min while controlling the on/off time of the stimulator by pushing the toggle switch attached to the walker handle.

  • PDF

The Effect of Habitat Size on Huanren Brown Frog (Rana huanrensis) Larvae's Growth Rate in Mt. Surak (수락산에 서식하는 계곡산개구리(Rana huanrensis Fei, Ye & Huang, 1991) 유생의 서식지 면적에 따른 생장률 연구)

  • Na, Sumi;Um, Yewon;Kim, Hyun-jung;An, Chi-Kyung;Yi, Hoonbok
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.2
    • /
    • pp.75-82
    • /
    • 2017
  • This study was executed to know the effect of the habitat size on huanren brown frog (Rana huanrensis) larvae's growth. We've conducted the study on Mt. Surak in Sanggye-dong, Nowon-gu, Seoul. Our study site was discriminated the huanren brown frog larvae's habitat into the three different areas, such as small area (S1, $3.91m^2$), middle area (S2, $4.42m^2$), and large area (S3, $38.37m^2$) in the same water channel. We measured two times per a week the 15 huanren brown frog larvae's body length, and developmental stages (foreleg, hind leg, tail length) including the environmental factors (humidity, air temperature and water temperature) of the study site from March 30 to June 28 in 2016. The only hatching rate was measured for the three egg sacs at the S2 study site. We found that the average hatching rate was $76.84{\pm}18.23(%)$ at S2. Generally, because of less precipitation during our study periods, all habitat areas for our study site were gradually decreased. The middle area, S2, was not reduced, the small area, S1, was reduced more than a fourth, and the largest area, S3, was drastically reduced more than half from initial area. There was no statistically difference among the three study sites for the three environmental factors (average humidity, average air temperature, and average water temperature) by F-test, but there were significant difference among the three site for the larvae's body length (F-test p< 0.05). Therefore, the larger of habitat areas, the larger of the larvae length as well as the faster of the larvae's developmental stages. When we measured the body lengths of immature huanren brown frogs, the immature frog of S1 was smallest, the immature frog of S3 was middle lenght, and the immature frog of S2 was largest. There were statistically different among the three study sites for the immature huanren brown frogs (F-test, p< 0.05). Because the S2 study site was relatively stable without rarely changing the study area, it meant that huanren brown frog was sensitive to habitat areas. Based on the results of this study, if we study on the effect of the altitude on the growth rate of huanren brown frog, it must be helpful in understanding the habitat environment of the population of huanren brown frog.

CASE REPORTS OF TREATMENT OF ERUPTION-DISTURBED MX. FIRST MOLAR BY SURGICAL EXPOSURE (맹출 장애를 가진 상악 제1대구치의 외과적 노출을 이용한 치험례)

  • Seok, Choong-Ki;Nam, Dong-Woo;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • The eruption of permanent teeth represents the movement in the alveolar bone before appearance in oral cavity, to the occlusal plane after appearance in oral cavity, and additive movement after reaching th the occlusal plane. Tooth eruption is mostly controlled by genetic signals. The eruption stage is divided to preeruptive alveolar stage, alveolar bone stage, mucosal stage according to the process of growth and development. If the disturbance is occured in any stage of eruption, tooth does not erupt. The cause of eruption disturbance are ectopic position of the tooth germ, obstruction of the eruption path and defects in the follicle or PDL. In the treatment of eruption disturbance, surgical procedures are commonly used. There are three kind of surgical procedure ; surgical exposure, surgical repositioning, surgical exposure and traction Surgical exposure is basic procedure. This involves removal of mucosa, bone, lesion that are surrounding the teeth, dental sac when necessary to maintain a patent channel between the crown and the normal eruptive path into the oral cavity. To ensure this patency, many techniques including cementation of a celluloid crown, packing with gutta-percha or zinc oxide-eugenol, or a surgical pack, are used. When surgical exposure is conducted, operators should not expose any part of cervical root cement and not injure periodontium or root of adjunct tooth. After surgical exposure, tooth should be surrounded by keratinized gingiva. There is direct relationship between the extent of development of pathophysiologic aberrations and the intensity of the manipulative injury inflicted on the tooth by surgical treatment, so operator should consider this thing. In these cases, surgical exposure is conducted on Maxillary 1st milars that have a eruption disturbance and improve the eruption disturbance effectively.

  • PDF

Analysis Trap and Device Characteristic of Silicon-Al2O3-Nitride-Oxide-Silicon Memory Cell Transistors using Charge Pumping Method (Charge Pumping Method를 이용한 Silicon-Al2O3-Nitride-Oxide-Silicon Flash Memory Cell Transistor의 트랩과 소자)

  • Park, Sung-Soo;Choi, Won-Ho;Han, In-Shik;Na, Min-Gi;Lee, Ga-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.7
    • /
    • pp.37-43
    • /
    • 2008
  • In this paper, the dependence of electrical characteristics of Silicon-$Al_2O_3$-Nitride-Oxide-Silicon (SANOS) memory cell transistors and program/erase (P/E) speed, reliability of memory device on interface trap between Si substrate and tunneling oxide and bulk trap in nitride layer were investigated using charge pumping method which has advantage of simple and versatile technique. We analyzed different SANOS memory devices that were fabricated by the identical processing in a single lot except the deposition method of the charge trapping layer, nitride. In the case of P/E speed, it was shown that P/E speed is slower in the SANOS cell transistors with larger capture cross section and interface trap density by charge blocking effect, which is confirmed by simulation results. However, the data retention characteristics show much less dependence on interface trap. The data retention was deteriorated as increasing P/E cycling number but not coincides with interface trap increasing tendency. This result once again confirmed that interface trap independence on data retention. And the result on different program method shows that HCI program method more degraded by locally trapping. So, we know as a result of experiment that analysis the SANOS Flash memory characteristic using charge pumping method reflect the device performance related to interface and bulk trap.