• 제목/요약/키워드: $K^+$ ion source

검색결과 633건 처리시간 0.031초

MgO 박막의 $\gamma$ 계수 측정용 이온빔원의 시작 및 동작특성 (Some Characteristics of Ion Beam Source for $\gamma$-Coefficient Measurement of MgO Thin Film)

  • 정신수;김준호;김희제;조정수;박정후;박차수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1752-1754
    • /
    • 1997
  • The Kaufman type ion beam source with focusing lens was prepared to measure $\gamma$-coefficient of MgO thin film. Initial discharge of the system was started with the discharge voltage of 25V, the cathode filament current of 5.5A at the constant magnetic field of 150G. The system shows the maximum ion current density of $120{\mu}A/cm^2$, energy dispersion of 200eV and beam divergence of $30^{\circ}$ under the condition of Ar gas pressure $2.5{\times}10^{-4}Torr$, the beam voltage of 500V, the discharge voltage of 90V, the accelerator voltage of -200V and the cathode filament current of 6.1A. When the focusing lens was installed onto the ion beam source, the spreadness diameter of ion beam was about 10mm.

  • PDF

새로운 이온화된 클라스터 빔원의 제작과 특성 조사 (Investigation of New Ionized Cluster Beam Source)

  • 고석근;장홍규;정형진;최원국
    • 한국진공학회지
    • /
    • 제5권3호
    • /
    • pp.251-257
    • /
    • 1996
  • The present paper the results of development of first experimental tests of a new ionized cluster beam (ICB) source. The novelty of ICB source lies in the fact that the crucible and ionization parts are spaced in one cylincrical shell but are not divided inan electric circuit. The ICB source adapts permanent mannets to increase the ionixation efficiency. The maximum obtained Cu+ ion current density I s1.5μA/㎠ 이었으며, 증착율이 초당 0.4Å일 때 이온화율은 3% 이었으며, 증착율이 초당 0.2Å일때는 이온화율이 6%이었다. 증착율이 초당 0.2Å이고, 가속전압이 4kV에서는 Cu+ 이온빔의 균일성이 95%이상이었다.

  • PDF

SURFACE PROCESSING OF TOOLS AND COMPONENTS BY MEVVA SOURCE ION IMPLANTATION

  • Lin, W.L.;Sang, J.M.;Ding, X.J.;Yuan, X.M.;Xu, J.;Zhang, H.X.;Zhang, X.J.
    • 한국진공학회지
    • /
    • 제4권S2호
    • /
    • pp.106-114
    • /
    • 1995
  • Direct implantation of metallic ion species has been employed in surface processing of industrial components and tools with very encouraging improvements in recent years. In spite of high technicla effectiveness, this new surface processing technique has not been extensively accepted by industries mainly because of high cost(capital and operating) compared with other competitive surface processing techniques. High current and large implantation area with eliminating the mass analyzer and the beam-scanning unit make metal vapor vacuum are(MEVVA)source ion implantation versatile, simple and cheap to operate and well suited to commercial surface processing. In this paper, the recent development of MEVVA source ion implantation technique ar Beijing Normal University has been reviewed and the results of production trials of several industrial components and tools implanted by MEVVA source ion implantation have been presented and discussed.

  • PDF

Quench analysis and protection circuit design of a superconducting magnet system for RISP 28GHz ECR ion source

  • Song, S.;Ko, T.K.;Choi, S.;Ahn, M.C.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.37-41
    • /
    • 2016
  • This paper presents the developed quench analysis code and protection circuit design for a superconducting magnet system of 28GHz electron cyclotron resonance (ECR) ion source. The superconducting magnet is composed of a hexapole magnet and four solenoid magnets located outside of the hexapole one. All magnets are wound with NbTi composite wire and impregnated by epoxy. By using the developed characteristic analysis code, the normal zone resistance, decaying current and temperature rising can be estimated during quench. Also, the stored magnetic energy is successfully consumed from the series resistor of the designed protection circuit. The analytical results are compared with the experimental results to verify the developed quench analysis code and protection circuit.

WC-Co 공구의 이온 주입에 따른 표면층 및 가공된 표면거칠기 특성 (Characteristics of Machined Surface Roughness and Surface Layers of WC-Co Tools with Plasma Source Ion Implantation)

  • 강성기;김영규;왕덕현;전영록;김원일
    • 한국기계가공학회지
    • /
    • 제9권1호
    • /
    • pp.106-113
    • /
    • 2010
  • The most suitable condition for plasma source ion implantation(PSII) was found based on the study of the characteristics of PSIIed tool and machined surfaces. The depth analysis according to the chemical bonding state of elements and surface component elements through the XPS and SIMS, was conducted to find the improved property of the PSIIed surface. Due to the diffusion of PSII, the nitrogen was found up to a depth of about 150nm according to the supplied voltage and ion implanted time. The deep diffusion by nitrogen caused the surface modification, but the formation of oxide component was found due to the residual gas contamination on the surface. Statistical method of ANOVA was conducted to find the effects of spindle speed and feed rate in interaction for machined surface roughness with PSIIed tools. The surface modification was found largely occurred by the nitrogen implanted surface with 2 hours for 27kV, 35kV and 43kV.

저 에너지 표면 개질 이온원이 설치된 진공 웹 공정을 이용한 2층 flexible copper clad laminate 제작 (Fabrication of 2-layer Flexible Copper Clad Laminate by Vacuum Web Coater with a Low Energy Ion Source for Surface Modification)

  • 최형욱;박동희;최원국
    • 한국재료학회지
    • /
    • 제17권10호
    • /
    • pp.509-515
    • /
    • 2007
  • In order to fabricate adhesiveless 2-layer flexible copper clad laminate (FCCL) used for COF (chip on film) with high peel strength, polyimide (PI; Kapton-EN, $38\;{\mu}m$) surface was modified by reactive $O_2^+$ and $N_2O^+$ ion beam irradiation. 300 mm-long linear electron-Hall drift ion source was used for ion irradiation with ion current density (J) higher than $0.5\;mA/cm^2$ and energy lower than 200 eV. By vacuum web coating process, PI surface was modified by linear ion source and then 10-20 nm thick Ni-Cr and 200 nm thick Cu film were in-situ sputtered as a tie layer and seed layer, respectively. Above this sputtered layer, another $8-9{\mu}m$ thick Cu layer was grown by electroplating and subsequently acid and base resistance and thermal stability were tested for examining the change of peel strength. Peel strength for the FCCLs treated by both $O_2^+$ and $N_2O^+$ ion irradiation showed similar magnitudes and increased as the thickness of tie layer increased. FCCL with Cu (200 nm)/Ni-Cr (20 nm)/PI structure irradiated with $N_2O^+$ at $1{\times}10^{16}/cm^2$ ion fluence was proved to have a strong peel strength of 0.73 kgf/cm for as-received and 0.34 kgf/cm after thermal test.

효율적인 Source Head 개발에 관한 연구 (A Study on Development of Efficient Source Head)

  • 김귀정
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2007년도 추계 종합학술대회 논문집
    • /
    • pp.865-868
    • /
    • 2007
  • 본 연구는 이온주입(Ion Implanter)장비의 성능향상과 재현성 있는 Source Head를 개발하기 위한 방법이다. Source Head의 Life time이 부품 간 사용되는 Life time과 틀리기 때문에 보통 20일 정도 사용하고, 한번 Source Head를 재생하기 위해 교체되는 부품들도 고가일 뿐 만 아니라 50% 이상이 일회성으로 사용되고 있다. 본 개발에서는 원자의 유입방식을 공중 분산방식으로 적용함으로써 열전자의 손실로 발생하는 부분을 억제하는 효과와 Arc Chamber의 압력을 낮게 가지고 갈 수 있고 Chamber의 오염을 억제하는 효과를 얻을 수 있었다.

  • PDF

Dopant-Activation and Damage-Recovery of Ion-Shower-Doped Poly-Si through $PH_3/H_2$ after Furnace Annealing

  • Kim, Dong-Min;Kim, Dae-Sup;Ro, Jae-Sang;Choi, Kyu-Hwan;Lee, Ki-Yong
    • Journal of Information Display
    • /
    • 제5권1호
    • /
    • pp.1-6
    • /
    • 2004
  • Ion shower doping with a main ion source of $P_2H_x$ using a source gas mixture of $PH_3/H_2$ was conducted on excimer-laser- annealed (ELA) poly-Si. The crystallinity of the as-implanted samples was measured using a UV-transmittance. The measured value of as-implanted damage was found to correlate well with the one calculated through/obtained from TRIM-code simulation. The sheet resistance was found to decrease as the acceleration voltage increased from 1 kV to 15 kV at a doping time of 1 min. However, it increases as the acceleration voltage increases under severe doping conditions. Uncured damage after furnace annealing is responsible for the rise in sheet resistance.

Performance of Beam Extractions for the KSTAR Neutral Beam Injector

  • Chang, D.H.;Jeong, S.H.;Kim, T.S.;Lee, K.W.;In, S.R.;Jin, J.T.;Chang, D.S.;Oh, B.H.;Bae, Y.S.;Kim, J.S.;Cho, W.;Park, H.T.;Park, Y.M.;Yang, H.L.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.240-240
    • /
    • 2011
  • The first neutral beam injector (NBI-1) has been developed for the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. A first long pulse ion source (LPIS-1) has been installed on the NBI-1 for an auxiliary heating and current drive of KSTAR core plasmas. Performance of ion and neutral beam extractions in the LPIS-1 was investigated initially on the KSTAR NBI-1 system, prior to the neutral beam injection into the main plasmas. The ion source consists of a JAEA magnetic bucket plasma generator with multi-pole cusp fields and a set of KAERI prototype-III tetrode accelerators with circular apertures. The inner volume of plasma generator and accelerator column in the LPIS-1 is approximately 123 liters. Final design requirements for the ion source were a 120 kV/ 65 A deuterium beam and a 300 s pulse length. The extraction of ion beams was initiated by the formation of arc plasmas in the LPIS-1, called as an arc-beam extraction method. A stable ion beam extraction of LPIS-1 has been achieved up to an 100 kV/42 A for a 4 s pulse length and an 80 kV/25 A for a 14 s pulse length. Optimum beam perveance of 1.21 microperv has been found at an accelerating voltage of 80 kV. Neutralization efficiency has been measured by using a water flow calorimetry (WFC) method of calorimeter and an operation of bending magnet. The full-energy species of ion beams have been detected by using the diagnostic method of optical multichannel analyzer (OMA). An arc efficiency of the LPIS was 0.6~1.1 A/kW depending on the operating conditions of arc discharge.

  • PDF