• Title/Summary/Keyword: $IrO_2$electrode

Search Result 96, Processing Time 0.036 seconds

Platinum complex oxide electrode catalyst for the solubilization of sewage sludge (하수슬러지 가용화 위한 백금족 복합 산화물 촉매 전극 개발)

  • Yoo, Jaemin;Kim, Hyunsook;pak, Daewon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.352-360
    • /
    • 2016
  • The purpose of this study was to determine the electrochemical properties develop DSA electrode for sewage sludge solubilization. Using Ir as a main catalyst, the catalyst selected for the sewage sludge solubilization durability and proceeds to functional electrode suitable for sewage sludge electrolysis experiment were obtained the following results. Less mass reduction of the sintering temperature of the main catalyst, Ir coated electrodes, the endothermic reaction zone $300^{\circ}C$ to $500^{\circ}C$, which was selected from a range of experiments. The efficiency of the catalyst results came up to $350^{\circ}C$ best. Each Binder stars (Ta, Sn, W) in this experiment was the biggest catalyst efficiency at $350^{\circ}C$. Used as a binder, $TaCl_5$, $SnCl_4$, $WCl_6$ of the Ta and without affecting the other characteristics of the main catalyst than Sn, W. For the 50% $IrO_2$ electrode is 1.4 V (vs. Ag / AgCl) in a current of about $29mA/cm^2$ was caused to evaluate the effectiveness of the electrode.

Reduction and Decomposition of Hazardous NOx by Discharge Plasma with $TiO_2$ ($TiO_2$ 촉매를 이용한 플라즈마반응에 의한 NOx의 분해)

  • Park, Sung-Gug;Woo, In-Sung;Hwang, Myung-Whan
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.54-60
    • /
    • 2008
  • The objective of this study is to obtain the optimal process condition and the maximum decomposition efficiency by measuring the decomposition efficiency, electricity consumption, and voltage in accordance with the change of the process variables such as the frequency, maintaining time period, concentration, electrode material, thickness of the electrode, the number of windings of the electrode, and added materials etc. of the harmful atmospheric contamination gases such as NO, $NO_2$, and $SO_2$ etc. with the plasma which is generated by the discharging of the specially designed and manufactured $TiO_2$ catalysis reactor and SPCP reactor. The decomposition efficiency of the NO, the standard samples, is obtained with the plasma which is being generated by the discharge of the combination effect of the $TiO_2$ catalysis reactor and SPCP reactor with the variation of those process variables such as the frequency of the high voltage generator($5{\sim}50kHz$), maintaining time of the harmful gases($1{\sim}10.5sec$), initial concentration($100{\sim}1,000ppm$), the material of the electrode(W, Cu, Al), the thickness of the electrode(1, 2, 3mm), the number of the windings of the electrode(7, 9, 11turns), basic gases($N_2$, $O_2$, air), and the simulated gas($CO_2$) and the resulting substances are analyzed by utilizing FT-IR & GC.

Degradation of Electrode and Membrane in Proton Exchange Membrane Fuel Cell After Water Electrolysis (수전해 반응에 의한 고분자전해질 연료전지 전극과 막의 열화)

  • Jeong, Jae-Hyeun;Shin, Eun-Kyung;Jeong, Jae-Jin;Na, Il-Chai;Chu, Cheun-Ho;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.695-700
    • /
    • 2014
  • Proton Exchange Membrane Fuel Cells (PEMFC) can generate hydrogen and oxygen from water by electrolysis. But the electrode and polymer electrolyte membrane degrade rapidly during PEM water electrolysis because of high operation voltage over 1.7V. In order to reduce the rate of anode electrode degradation, unsupported $IrO_2$ catalyst was used generally. In this study, Pt/C catalyst for PEMFC was used as a water electrolysis catalyst, and then the degradation of catalyst and membrane were analysed. After water electrolysis reaction in the voltage range from 1.8V to 2.0V, I-V curves, impedance spectra, cyclic voltammograms and linear sweep voltammetry (LSV) were measured at PEMFC operation condition. The degradation rate of electrode and membrane increased as the voltage of water electrolysis increased. The hydrogen yield was 88 % during water electrolysis for 1 min at 2.0V, the performance at 0.6V decreased to 49% due to degradation of membrane and electrode assembly.

Degradation Evaluation of PEM Water Electrolysis by Method of Degradation Analysis Used in PEMFC (고분자전해질 연료전지 열화 분석방법에 의한 PEM 수전해 열화 평가)

  • Oh, Sohyeong;Yang, Jinwon;Chu, Cheun-Ho;Na, Il-Chai;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.1-5
    • /
    • 2021
  • The PEM(Proton Exchange Membrane)water electrolysis uses the same PEM electrolyte membrane as the PEM fuel cell and proceeds by the same reaction but the opposite direction. The PEM fuel cell has many methods of degradation analysis since many studies have been conducted on the degradation and durability of the membrane and catalyst. We examined whether PEM fuel cell durability evaluation method can be applied to PEM electrolytic durability evaluation. During the PEM electrolytic degradation process, LSV(Linear sweep voltammetry), CV(Cyclic voltammetry), Impedance, SEM(Scanning Electron Microscope) and FT-IR(Fourier Transform Infrared spectroscopy) were analyzed and compared under the same conditions as the PEM fuel cell. As the PEM fuel cell, hydrogen passing through the membrane was oxidized at the Pt/C electrode, and the hydrogen permeation current density was measured to analyze the degree of degradation of the PEM membrane. Electrode degradation could be analyzed by measuring the electrode active area (ECSA) by CV under hydrogen/nitrogen flowing conditions. While supplying hydrogen and air to the Pt/C electrode and the IrO2 electrode, the impedance of each electrode was measured to evaluate the durability of the electrode and membrane.

Review on the Determination of Frumkin, Langmuir, and Temkin Adsorption Isotherms at Electrode/Solution Interfaces Using the Phase-Shift Method and Correlation Constants

  • Chun, Jinyoung;Chun, Jang H.
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.734-745
    • /
    • 2016
  • This review article described the electrochemical Frumkin, Langmuir, and Temkin adsorption isotherms of over-potentially deposited hydrogen (OPD H) and deuterium (OPD D) for the cathodic $H_2$ and $D_2$ evolution reactions (HER, DER) at Pt, Ir, Pt-Ir alloy, Pd, Au, and Re/normal ($H_2O$) and heavy water ($D_2O$) solution interfaces. The Frumkin, Langmuir, and Temkin adsorption isotherms of intermediates (OPD H, OPD D, etc.) for sequential reactions (HER, DER, etc.) at electrode/solution interfaces are determined using the phase-shift method and correlation constants, which have been suggested and developed by Chun et al. The basic procedure of the phase-shift method, the Frumkin, Langmuir, and Temkin adsorption isotherms of OPD H and OPD D and related electrode kinetic and thermodynamic parameters, i.e., the fractional surface coverage ($0{\leq}{\theta}{\leq}1$) vs. potential (E) behavior (${\theta}$ vs. E), equilibrium constant (K), interaction parameter (g), standard Gibbs energy (${\Delta}G_{\theta}{^{\circ}}$) of adsorption, and rate (r) of change of ${\Delta}G_{\theta}{^{\circ}}$ with ${\theta}$ ($0{\leq}{\theta}{\leq}1$), at the interfaces are briefly interpreted and summarized. The phase-shift method and correlation constants are useful and effective techniques to determine the Frumkin, Langmuir, and Temkin adsorption isotherms and related electrode kinetic and thermodynamic parameters (${\theta}$ vs. E, K, g, ${\Delta}G_{\theta}{^{\circ}}$, r) at electrode/solution interfaces.

A Review of Chlorine Evolution Mechanism on Dimensionally Stable Anode (DSA®) (DSA 전극에서 염소 발생 메커니즘)

  • Kim, Jiye;Kim, Choonsoo;Kim, Seonghwan;Yoon, Jeyong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.531-539
    • /
    • 2015
  • Chlor-alkali industry is one of the largest electrochemical processes which annually producing 70 million tons of sodium hydroxide and chlorine from sodium chloride solution. $DSA^{(R)}$ (Dimensionally Stable Anodes) electrodes such as $RuO_2$ and $IrO_2$, which is popular in chlor-alkali process, have been investigated to improve the chlorine generation efficiency. Although DSA electrode has been developed with various researches, understanding of the chlorine evolution mechanism is essential to the development of highly efficient DSA electrode. In this review paper, chlorine generation mechanisms are summarized and that of key factors are identified to systematically understand the chlorine generation mechanism. Rate determining step, effect of pH, reaction intermediate, and electrode crystal structure were intensively overviewed as key factors of the chlorine mechanism.

Effect of Number of Shutdown on the Decrease of Performance in PEM Water Electrolysis (PEM 수전해에서 정지횟수가 성능 감소에 미치는 영향)

  • Cheunho Chu;Jongwon Yang;Ilchai Na;Yoonjin Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.2
    • /
    • pp.202-207
    • /
    • 2023
  • In the case of driving water electrolysis by receiving surplus electricity from solar and wind power generation, operation and stopping must be repeated according to weather fluctuations. When the PEMWE(Polymer Electrolyte Membrane Water Electrolysis) is driven and stopped, the PEM fuel cell is in the same state as the PEM fuel cell due to the residual hydrogen and oxygen, and the high potential of the water electrolysis formed during operation is highly likely to cause degradation of the electrode and membrane even during stopping. In this study, in order to check how much degradation of the electrode and membrane progresses during the repeated driving/shutdown process of PEM water electrolysis, the performance decrease was measured by changing the number of driving/shutdown for 144 hours. Changes in electrode catalyst active area, hydrogen permeability and fluorine emision rate of membranes were analyzed to measure changes in the properties of electrodes and polymer membranes. Overall, the PEMWE performance decreased as the number of stops increased. When stopped 5 times in 144 hours, the IrOx catalyst activity decreased by more than 30%, and the hydrogen permeability increased by 80%, confirming that both the electrode and the membrane were deteriorated.

Electrochemistry of Hemoglobin in the Chitosan and TiO2 Nanoparticles Composite Film Modified Carbon Ionic Liquid Electrode and Its Electrocatalysis

  • Sun, Wei;Li, Xiaoqing;Liu, Shufeng;Jiao, Kui
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.3
    • /
    • pp.582-588
    • /
    • 2009
  • Direct electron transfer of hemoglobin (Hb) in the chitosan (CTS) and $TiO_2$ nanoparticles (nano-$TiO_2$) composite films was achieved by using a room temperature ionic liquid of 1-butyl-3-methylimidazolium hexafluorophosphate ($BMIMPF_6$) modified carbon paste electrode (CILE) as the basal electrode. UV-Vis and FT-IR spectroscopy indicated that Hb in the film retained the native structure. Electrochemical investigation indicated that a pair of well-defined quasi-reversible redox peaks of Hb heme Fe(III)/Fe(II) was obtained with the formal potential located at -0.340 V (νs. SCE) in pH 7.0 phosphate buffer solution (PBS). The electrochemical parameters such as the electron transfer coefficient (α), the electron transfer number (n) and the standard electron transfer rate constant ($k_s$) were got as 0.422, 0.93 and 0.117 $s^{-1}$, respectively. The fabricated CTS/nano-$TiO_2$/Hb/CILE showed good electrocatalytic ability to the reduction of trichloroacetic acid (TCA) and hydrogen peroxide ($H_2O_2$), which exhibited a potential application in fabricating a new kind of third generation biosensor.

Development of PEMWE MEA & System for Discrete Regenerative Fuel Cell (분리형 재생 연료전지를 위한 수전해 MEA 및 시스템 개발)

  • CHOI, NAKHEON;YOON, DAEJIN;HAN, CHANGHYUN;LEE, JUNYEONG;SONG, MINAH;JUNG, HYEYOUNG;CHOI, YUNKI;MOON, SANGBONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.4
    • /
    • pp.335-340
    • /
    • 2016
  • Hydrogen production through proton exchange membrane water electrolysis (PEMWE) is expeditiously receiving international attention for renewable energy sources as well as energy storage system applications due to its environmentally friendly uses. A series of $Ir_{0.2}Ru_{0.8}O_2$ $Ir_{0.5}Ru_{0.8}O_2$ & $IrO_2$ catalysts were synthesized and electrochemically evaluated by using linear sweep voltammetry (LSV) technique. Furthermore, the PEMWE performances of full cells were evaluated by recording I-V Curves. The developed PEMWE stack was also operated in combination with a proton exchange membrane fuel cell (PEMFC) to demonstrate the discrete regenerative fuel cell (DRFC) performances. Produced hydrogen and oxygen from PEMWE were used as a fuel to operate PEMFC to establish a DRFC system.