• 제목/요약/키워드: $Hg^{2+}$-selectivity

검색결과 60건 처리시간 0.023초

Fluorescence Sensing Properties of 2-(2'-Hydroxyphenyl)quinoline and Derivatives

  • Helal, Aasif;Lee, Sang-Hoon;Ren, Wen Xiu;Cho, Chan-Sik;Kim, Hong-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권5호
    • /
    • pp.1599-1603
    • /
    • 2011
  • Novel chemosensors based on 2-(2'-hydroxyphenyl)quinoline were prepared and evaluated for sensing metal cations. The photophysical properties of chemosensors 1-3 were examined and their ion-selectivity was evaluated by measuring their fluorescent emission responses to alkali, alkaline earth, and transition metal ions. Chemosensors 1, 2 and 3 show ratiometric and enhanced fluorescence changes with transitional metals that are efficient fluorescence quenchers, especially 3 has a high binding constant with $Hg^{+2}$ in $CH_3CN$.

Syntheses and Ion Selectivities of Dimeric Rhodamine 6G Chemosensors

  • Chang, Seung Hyun;Choi, Jin-Wook;Chung, Kwang-Bo
    • 한국환경과학회지
    • /
    • 제22권10호
    • /
    • pp.1273-1278
    • /
    • 2013
  • Novel rhodamine 6G fluorescent chemosensors 1 and 2 for the detection of transition metal cations were synthesized through the condensation of rhodamine 6G ethylenediamine with each of 2-hydroxy-1-naphthaldehyde and 2,6-pyridinedicarbaldehyde, respectively. 1 and 2 were characterized using $^{13}C$ NMR, $^1H$ NMR and mass spectroscopy. Fluorometric and colorimetric measurements involving various metal ions revealed the ring opening of the rhodamine 6G spirocycle framework. In the absence of metal cations, 2 was colorless and non-fluorescent, whereas the addition of metal cations ($Hg^{2+}$ and others) changed the color to pink, accompanied by the appearance of an orange fluorescence. The chemosensors exhibited high selectivity for $Hg^{2+}$ over other divalent first-row transition metals. The complexes of $Hg^{2+}$ with 1 and 2 were successfully isolated. A huge enhancement in the fluorescence for both one- and two-photon excitations makes these compounds suitable candidates to be used for fluorescent labeling of biological systems.

비대칭 Polysulfone계(PS/PES/PPS)막 제조시 물리적 인자의 영향 및 기체투과 특성 (Physical Properties and Permeation Characteristics of Polysulfone group(PS/PES/PPS) membrane for Gas Permeation)

  • 박영해
    • 한국산업융합학회 논문집
    • /
    • 제4권1호
    • /
    • pp.77-85
    • /
    • 2001
  • This paper was to investigate the preparation of polysulfone(PS), polyethersulfone(PES) and polyphenylsulfone(PPS) membrane. The thermal property of PPS was higher than that of others. From the result of SEM, the concentration of polymer was found to have a significant effect on the structure of membrane, and the structure of membrane made of PES is found to have regular micell form of asymmetry. Permeability and selectivity for oxygen and nitrogen gas in the air were analyzed by GC. Permeabilities of the membrane made of PES for oxygen and nitrogen in air, 1.5 and $0.7(x10^9[cm^3(STP)cm/cm^2seccmHg]) $, respectively was higher than that of others. and Selectivity of the membrane made of PPS for oxygen to nitrogen gas in air was 2.9.

  • PDF

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

Rhodamine 6G Based New Fluorophore Chemosensor Toward Hg2+

  • Son, Young-A;Park, June-Min
    • 한국염색가공학회지
    • /
    • 제24권3호
    • /
    • pp.158-164
    • /
    • 2012
  • Rhodamine dyes belong to xanthene family has excellent photostability and photophysical properties. In rhodamine dyes, Rhodamine 6G and its precursors also have xanthene chromophore and it shows high fluorescent quantum yield. Rhodamine 6G derivates are simple to synthesis and its high sensitivity and water solubility are suitable as good chemosensor. In this regard, Rhodamine 6G derivates which have selectivity to specific metal cation can used to detect various heavy metal ions. In this study, rhodamine 6G derivatives were synthesized by reaction of rhodamine 6G hydrazide and glyoxal and 4-phenyl thiosemicarbazide and it showed colorimetric and fluorescence sensing toward $Hg^{2+}$ ion. This novel chemosensor was analyzed and measured on UV-Vis and fluorescence spectrophotometer. HOMO/LUMO values were also calculated by computational calculation.

Effect of Salt on Facilitated Propylene Transport through Crosslinked PVA/Silver Salt Complex Membranes

  • Kim, Jong-Hak;Min, Byoung-Ryul;Lee, Ki-Bong;Kang, Yong-Soo
    • Korean Membrane Journal
    • /
    • 제8권1호
    • /
    • pp.43-49
    • /
    • 2006
  • Complex membranes consisting of silver salt ($AgBF_4,\;AgCF_3SO_3,\;AgSbF_6,\;AgNO_3$) and poly(vinyl alcohol) (PVA) or crosslinked PVA (CPVA) were prepared and tested for the separation of propylene/propane mixtures. For the tested membranes, the complex membranes containing $AgBF_4$ exhibited the highest separation properties, i.e., approximately 20 GPU ($1 GPU=10^{-6}cm^3 (STP)/(cm^2 sec cmHg)$) and 100 of selectivity at 0.2 of silver mole fraction. The CPVA membranes containing silver salt always showed higher selectivity than PVA membranes, presenting silver ions coordinated to -CHO are more effective than those to -OH groups. The threshold silver concentration of CPVA membranes was lower than that of PVA membranes, which might be due to stronger interaction of silver ions with -CHO than that with -OH. The composition at which the selectivity is the highest did not significantly depend on the crosslinking, but did on the kind of silver salt.

플라즈마 처리에 의한 폴리메틸펜텐 막의 $CO_2/N_2$ 혼합가스의 투과특성 (Permeation Characteristics of $CO_2/N_2$ Mixture Gases through Plasma Treated Poly (methylpentene) Membrane)

  • 전성우;곽현;배성렬
    • 멤브레인
    • /
    • 제13권2호
    • /
    • pp.73-80
    • /
    • 2003
  • 폴리메틸펜텐 막(polymethylpentene membrane, PMP)을 Ar, NH_3$ 플라즈마로 표면 처리하고, 처리 전후의 투과 도와 선택도의 변화를 관찰하였다. Ar 플라즈마로 처리하였을 때 O/C의 비율이 증가하며 친수성기 (OH, COOH, C=O)의 도입이 확인되었고 $NH_3$ 플라즈마로 처리하였을 때 아민, 아미노기가 도입되었다. 플라즈마 처리된 폴리메틸펜텐막에서 $CO_2$의 투과도와 $N_2$,에 대한 선택도 (Actual Separation Factor)의 최적조건은 Ar 플라즈마 처리 (30 W-6 min)의 경우 각각 182 Barrer [$10^{-10}\;cm^3(STP)cm/cm^2$.s.cmHg]와 6.17이며, $NH_3$, 플라즈마 처리 (30 W-8 min)의 경우 각각 144 Barrer [$10^{-10}/cm^2(STP)cm/cm^2$.s.cmHg] 와 6.13을 얻었다.

수질환경에서 광섬유 센서의 구리 이온 감지 물질로서 8-Hydroxyquinoline 합성유도체의 광학적 반응 특성 연구 (Study on Optical Characteristics of 8-Hydroxyquinoline Synthesized Derivative as Sensing Material of the Fiber-Optic Copper Ion Sensor in Aqueous Environment)

  • 김범규;박병기
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.100-105
    • /
    • 2017
  • 수질환경에서 구리이온을 검출하기 위하여 광섬유 센서의 구리 이온 감지 물질로 8-Hydroxyquinolin-2carboxaldehyde와 4-Aminoantipyrine으로 합성된 8-Hydroxyquinoline 합성유도체에 대해 광학적 반응 특성을 조사하였다. 실험은 광섬유를 이용한 측정시스템을 이용하여 수용액에 용해된 구리 이온의 농도에 대해 합성유도체에 의한 흡광도와 관계를 평가하기 위하여 수행되었다. 8-Hydroxyquinoline 합성유도체는 수질 환경에서 다양한 금속 이온들 중에서 구리 이온에 대해 노란색에서 붉은색으로 변화되는 높은 발색 현상을 나타냈으며 530 nm의 고유 흡광 파장을 보였다. 제작된 합성유도체의 Cu 이온에 대한 선택성을 평가하기 위하여 Hg 이온의 영향을 조사하였다. Cu와 Hg 이온의 다양한 농도 비 (Cu:Hg ratio 0.05부터 20까지)에서 흡광도를 측정한 결과, Cu 이온의 농도 증가에 따라 530nm에서 흡광도가 증가하는 경향을 보였다. 구리 이온의 고유 흡광 파장인 530 nm에서 합성 유도체에 의한 흡광도 세기는 구리 이온의 로그 농도에 선형으로 비례하였다. 따라서 8-Hydroxyquinoline합성유도체는 광섬유 센서의 구리 이온 감지 물질로 우수한 특성을 보임을 실험적으로 확인할 수 있었다.

열분해성 그룹이 도입된 폴리이미드로부터 유도된 탄소분자체막의 수소 분리 특성 (Hydrogen Separation of Carbon Molecular Sieve Membranes Derived from Polyimides Having Decomposable Side Groups)

  • Young Moo Lee;Youn Kook Kim;Ji Min Lee;Ho Bum Park
    • 멤브레인
    • /
    • 제14권2호
    • /
    • pp.99-107
    • /
    • 2004
  • Carbon molecular sieve (CMS) membranes were prepared by pyrolysis of polyimides having carboxylic acid groups and applied to the hydrogen separation. The polymeric membranes having carboxylic acid groups showed different steric properties as compared with polymeric membranes having other side groups ($-CH_3$ and $-CF_3$) because of the hydrogen bond between the carboxylic acid groups. However, the microporous CMS membranes were significantly affected by the decomposable side groups evidenced from the wide angle X-rat diffraction, nitrogen adsorption isotherms, and single gas permeation measurement. Furthermore, the gas separation properties of the CMS membranes were essentially affected by the pyrolysis temperature. As a result, the CMS membranes Prepared by Pyrolysis of polyimide containing carboxylic acid froups at $700^{\circ}C$ showed the $H_2$ permeability of 3,809 Baller [$1{\times}10^{-10}$ H $\textrm{cm}^$(STP)cm/$\textrm{cm}^2$.s.cmHg], $H_2$/$N_2$, selectivity of 46 and $H_2$/$CH_4$ selectivity of 130 while the CMS membranes derived from polyimide showed the H$_2$ permeability of 3,272 Barrer, $H_2$/$N_2$ selectivity of 136 and $H_2$/$CH_4$ selectivity of 177.