• 제목/요약/키워드: $H_2$ oxidation

검색결과 2,329건 처리시간 0.028초

소규모 염색공장 폐수의 처리에 관한 연구 (A Study on the Treatment of Wastewater from Small-scale dyehouse)

  • 이준현;허항록;김광진;김민영;신재영
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.23-25
    • /
    • 2002
  • This study was conducted to understand characteristics of wastewater which is discharged from small-scale dyehouse located in Seoul downtown area and to Find the appliable treatment method on the spot. The results of this study were summarized as followings. 1. The method which is used at present is mostly flocculation by coagulant or fenton oxidation. But the treatment efficiency of them are not good. 2. The results of fenton oxidation experiment demonstrated that treatment efficiency of COD was limited, which showed the need of the additional process or the improvement of existing treatment method, while the color was reduced considerably in optimal condition. 3. The optimal condition of fenton oxidation are as followings. -Feasible pH was in the 3∼4 regardless of the kinds of iron ions, But the fluctuation of treatment efficiency with the change of pH was small - The mass ratio of H$_2$O/CODcr was used to evaluate the parameter of H$_2$O$_2$ The optimal range of this was in 0.7∼1,3 and it was observed that the ratio got higher as the quality got worse. -For iron ion, FeCl$_2$4H$_2$O turned out to be more effective for removal of color compared with was compared FeSO$_4$7H$_2$Oin. the mass ratio of Fe/H$_2$O$_2$ of 2.3∼2.8 for of FeSO$_4$7H$_2$O and 1.6∼1.8 for FeCl$_2$4H$_2$O resulted in good treatment efficiencies. 4. With adsorption process applied before fenton oxidation in order to treat the high concentration wastewater, the treatment efficiency increased by 61% in CODcr, 55% in color. and if the power activated carbon is injected in more than 2500mg/$\ell$, the wastewater can be treated within the effluent quality criteria.

  • PDF

질화막 성장의 하지의존성에 따른 적층캐패시터의 이상산화에 관한 연구 (A Study on the Abnormal Oxidation of Stacked Capacitor due to Underlayer Dependent Nitride Deposition)

  • 정양희
    • 한국전기전자재료학회논문지
    • /
    • 제11권1호
    • /
    • pp.33-40
    • /
    • 1998
  • The composite SiO$_2$/Si$_3$N$_4$/SiO$_2$(ONO) film formed by oxidation on nitride film has been widely studied as DRAM stacked capacitor multi-dielectric films. Load lock(L/L) LPCVD system by HF cleaning is used to improve electrical capacitance and to scale down of effective thickness for memory device, but is brings a new problem. Nitride film deposited using HF cleaning shows selective deposition on poly silicon and oxide regions of capacitor. This problem is avoidable by carpeting chemical oxide using $H_2O$$_2$cleaning before nitride deposition. In this paper, we study the limit of nitride thickness for abnormal oxidation and the initial deposition time for nitride deposition dependent on underlayer materials. We proposed an advanced fabrication process for stacked capacitor in order to avoid selective deposition problem and show the usefulness of nitride deposition using L/L LPCVD system by $H_2O$$_2$cleaning. The natural oxide thickness on polysilicon monitor after HF and $H_2O$$_2$cleaning are measured 3~4$\AA$, respectively. Two substrate materials have the different initial nitride deposition times. The initial deposition time for polysilicon is nearly zero, but initial deposition time for oxide is about 60seconds. However the deposition rate is constant after initial deposition time. The limit of nitride thickness for abnormal oxidation under the HF and $H_2O$$_2$cleaning method are 60$\AA$, 48$\AA$, respectively. The results obtained in this study are useful for developing ultra thin nitride fabrication of ONO scaling and for avoiding abnormal oxidation in stacked capacitor application.

  • PDF

K-Mn/Fe2O3 촉매 상 H2O2 분해에 의한 건식산화제 생성 및 모사 배가스 유량에 따른 NO 산화공정 (A study on production of dry oxidant by decomposition of H2O2 on K-Mn/Fe2O3 catalyst and NO oxidation process according to simulated flue gas flow)

  • 최희영;신우진;장정희;한기보
    • 한국응용과학기술학회지
    • /
    • 제34권2호
    • /
    • pp.367-375
    • /
    • 2017
  • 본 연구에서는 배가스 내 존재하는 오염물질인 NO의 처리효율을 증대시키기 위하여 NO 산화공정을 연구하였으며, 강력한 산화력의 건식산화제를 제조하는 방법으로 $H_2O_2$ 촉매분해가 도입되었다. $H_2O_2$ 분해공정 상에서 적용 가능한 $K-Mn/Fe_2O_3$ 불균일계 촉매가 제조되었으며, 이들이 가지는 물리화학적 특성이 $H_2O_2$ 분해반응에 미치는 영향이 조사되었다. 제조된 건식산화제는 NO가 포함된 모사 배가스를 처리하기 위한 NO 산화공정에 적용되었으며, 다양한 모사 배가스의 유량(5, 10, 20 L/min)에서 약 100% 가까운 NO 전환율을 확인 하였다.

Evaluation of Effective Process Operation for the Texitile Dyeing Wastewater by Ferrous Solution and Hydrogen Peroxide

  • Lee, Sang Ho;Moon, Hey Jin
    • 한국환경과학회지
    • /
    • 제13권11호
    • /
    • pp.987-991
    • /
    • 2004
  • The purpose of this research is to evaluate the removal efficiencies of COD$\_$Cr/ and color for the dyeing wastewater by the different dosages of ferrous solution and H$_2$O$_2$ in Fenton process. In the case of H$_2$O$_2$ divided dosage for the Fenton's reagent 7:3 of H$_2$O$_2$ was more effective than 3:7 to remove COD$\_$Cr/ and color. The results showed that COD$\_$Cr/ was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand color was removed by Fenton oxidation rather than Fenton coagulation. The removal mechanism of COD$\_$Cr/ and color was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However, the final removal efficiency of COD$\_$Cr/ and color was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide.

Mutational Analysis of the Metal-binding Sites of Peroxide Sensor PerR

  • Won, Young-Bin;Ji, Chang-Jun;Cho, Ju-Hyun;Lee, Jin-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권6호
    • /
    • pp.1573-1576
    • /
    • 2010
  • Bacillus subtilis PerR is a metal-dependent peroxide-sensing transcription factor which uses metal-catalyzed histidine oxidation for peroxide-sensing. PerR contains two metal binding sites, one for structural $Zn^{2+}$ and the other for the regulatory/peroxide-sensing metal. Here we investigated the effect of mutations at both the structural and regulatory metal binding sites on the oxidation of either H37 or H91, two of the peroxide-sensing ligands. All four serine substitution mutants at the structural $Zn^{2+}$ site (C96S, C99S, C136S and C139S) exhibited no detectable oxidation at histidine residues. Two of the alanine substitution mutants at regulatory metal site (H37A and D85A) exhibited selective oxidation preferentially at the H91-containing tryptic peptide, whereas no oxidation was detected in the other mutants (H91A, H93A and D104A). Our results suggest that the cysteine residues coordinating structural $Zn^{2+}$ are essential for peroxide sensing by PerR, and that the C-terminal regulatory metal binding site composed of H91, H93 and D104 can bind $Fe^{2+}$, providing a possible explanation for the peroxide sensing mechanisms by PerR.

펜톤 산화에 의한 하수 슬러지로부터 유기산 생성에 관한 연구 (A Study on the Production of VFAs from Sewage Sludge by Fenton's Oxidation)

  • 한금석;남영우
    • 대한환경공학회지
    • /
    • 제27권2호
    • /
    • pp.184-190
    • /
    • 2005
  • 하수 슬러지를 펜톤 산화공정으로 처리하는 새로운 VFAs 생산 공정을 연구하였다. 과산화수소와 촉매인 $Fe^{2+}$의 적정농도를 실험하고, 최적 반응온도 및 반응시간에 대한 기초 자료를 얻고자 하였다. 기존의 과산화수소를 액상산화제로 사용한 공정보다 저농도의 $Fe^{2+}$를 촉매로 사용하는 펜톤 산화공정으로 과산화수소의 사용량을 대폭 감소시키고도 VFAs 생성량이 4배 정도 증가하는 결과를 얻었다. 과산화수소와 $Fe^{2+}$의 적정 농도는 각각 0.62 M과 0.007M 이었다. VFAs 생성반응은 초기 1분 이내에서 빠르게 진행되었으며 생성된 VFAs의 일부가 초산과 $CO_2$로 분해되는 연속반응의 특성이 나타났다. 경제성을 감안하면 반응온도는 $25^{\circ}C$, 반응시간은 10분 정도가 적절한 반응조건으로 생각된다. 초기 pH $3{\sim}6.3$에서 VFAs의 생성에 미치는 pH의 영향은 관찰되지 않았다.

Selective Oxidation of Hydrogen Sulfide to Elemental Sulfur with Fe/MgO Catalysts in a Slurry Reactor

  • Lee, Eun-Ku;Jung, Kwang-Deog;Joo, Oh-Shim;Shul, Yong-Gun
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권2호
    • /
    • pp.281-284
    • /
    • 2005
  • The Fe/MgO catalysts with different Fe loadings (1, 4, 6, 15 and 30 wt% Fe) were prepared by a wet impregnation with iron nitrate as precursor. All of the catalysts were characterized by BET surface analyzer, X-ray diffraction (XRD), temperature-programmed reduction (TPR), and X-ray photoelectron spectroscopy (XPS). The maximum removal capacity of $H_2S$ was obtained with 15 wt% Fe/MgO catalyst which had the highest BET surface area among the measured catalysts. XRD of Fe/MgO catalysts showed that well dispersed Fe particles could be present on Fe/MgO with Fe loadings below 15 wt%. The crystallites of bulk $\alpha$-$Fe_2O_3$ became evident on 30 wt% Fe/MgO, which were confirmed by XRD. TPR profiles showed that the reducibility of Fe/MgO was strongly related to the loaded amounts of Fe on MgO support. Therefore, the highest removal efficiency of $H_2S$ in wet oxidation could be ascribed to a good dispersion and high reducibility of Fe/MgO catalyst. XPS studies indicated that the $H_2S$ oxidation with Fe/MgO could proceed via the redox mechanism ($Fe^{3+}\;{\leftrightarrow}\;Fe^{2+}$).

Characterization of Carboxylated Cellulose Nanocrystals from Recycled Fiberboard Fibers Using Ammonium Persulfate Oxidation

  • KHANJANZADEH, Hossein;PARK, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권2호
    • /
    • pp.231-244
    • /
    • 2020
  • As a way of finding value-added materials from waste medium density fiberboard (MDF), this study characterized cellulose nanocrystals (CNCs) isolated by ammonium persulfate (APS) oxidation using recycled MDF fibers. Chemical composition of the recycled MDF fibers was done to quantify α-cellulose, hemicellulose, lignin, nitrogen, ash and extractives. The APS oxidation was performed at 60 ℃ for 16 h, followed by ultrasonication, which resulted in a CNC yield of 11%. Transmission electron microscope images showed that rod-like CNCs had an average length and diameter of 167±47 nm and 8.24±2.28 nm, respectively, which gave an aspect ratio of about 20. The conductometric titration of aqueous CNCs suspension resulted in a carboxyl content of 0.24 mmol/g and the degree of oxidation was 0.04. Attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy clearly showed the presence of carboxyl group on the CNCs prepared by the APS oxidation. The change of pH of the aqueous CNC suspension from 4 to 7 converted the carboxyl group to sodium carboxylate group. These results showed that the APS oxidation was facile and CNCs had a one-step preparation method, and thus suggested an optimization of the oxidation condition in future.

가축 사체 매몰지 침출수 처리를 위한 Fenton 산화공정의 최적조건 (Optimal Condition of Operation Parameter for Livestock Carcass Leachate using Fenton Oxidation Process)

  • 안상우;정영철;유지영;민지은;이시진;박재우
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권1호
    • /
    • pp.26-35
    • /
    • 2013
  • Outbreak of animal infectious diseases such as foot-and-mouth disease, avian influenza are becoming prevalent worldwide. For prevent the further infection, tremendous numbers of the infected or culled stocks are buried around farm. This burial method can generate a wide range of detrimental components such as leachate, nutrient, salt, and pathogenic bacteria, consequently. In this study, for the stabilization of livestock carcasses leachate, advanced oxidation processes utilizing the Fenton reaction was investigated in lab-scale experiments for the treatment for $COD_{Cr}$ of livestock carcass leachate. $COD_{Cr}$ reduction by the Fenton oxidation was investigated response surface methodology using the Box-Begnken methods were applied to the experimental results. A central composite design was used to investigate the effects of the independent variables of pH ($x_1$), dosage of $FeCl_2{\cdot}4H_2O$ ($x_2$) and dosage of $H_2O_2$ ($x_3$) on the dependent variables $COD_{Cr}$ concentration ($y_1$). A 1 M NaOH and $H_2SO_4$ was using for pH control, $FeCl_2{\cdot}4H_2O$ was used as iron catalyst and NaOH was used for Fenton reaction. The optimal conditions for Fenton oxidation process were determined: pH, dosage of $FeCl_2{\cdot}4H_2O$ and dosage of $H_2O_2$ were 3, 0.6 g (0.0151 M) and 7 mL(0.259 M), respectively. Statistical results showed the order of significance of the independent variables to be pH > initial concentration of ferrous ion > initial concentration of hydrogen peroxide.

Fe-2%Ni 합금의 고온 산화 (High-temperature Oxidation of Fe-2%Ni Alloys)

  • 이동복;정재옥;박순용;조규철;;김민정
    • 한국표면공학회지
    • /
    • 제51권2호
    • /
    • pp.104-109
    • /
    • 2018
  • Fe-2 wt.%Ni alloys were fabricated by metal powder injection molding, and their oxidation behavior at $600-700^{\circ}C$ for 30 h in air was studied in order to find the effect of the small addition of Ni in the iron matrix on the high-temperature oxidation. Oxide scales that formed after oxidation consisted primarily of $Fe_2O_3$, where microscopic voids were scattered. Nickel was segregated initially at the scale/matrix interface, and later at the lower part of the $Fe_2O_3$ scale. At $600^{\circ}C$, Fe-2wt.%Ni alloys oxidized parabolically initially, and linearly after 15 h. At $650-700^{\circ}C$, they oxidized linearly from the initial period. Although Fe-2wt.%Ni alloys oxidized slower than pure iron, their oxidation rates were relatively fast.