• Title/Summary/Keyword: $D^*S$

Search Result 41,529, Processing Time 0.063 seconds

Development of World's Largest 21.3' LTPS LCD Using Sequential Lateral Solidification (SLS) Technology

  • Kang, Myung-Koo;Kim, H.J.;Chung, J.K.;Kim, D.B.;Lee, S.K.;Kim, C.H.;Chung, W.S.;Hwang, J.W.;Joo, S.Y.;Maeng, H.S.;Song, S.C.;Kim, C.W.;Chung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.241-244
    • /
    • 2003
  • The world largest 21.3" LTPS LCD has been successfully developed using SLS crystallization technology. Successful integration of gate circuit, transmission gate and level shifter was performed in a large area uniformly. Uniformity and high performance from high quality grains of SLS technology make it possible to come true a uniform large size LTPS TFT-LCD with half number of data driver IC's used in typical a-Si LCD. High aperture ratio of 65% was obtained using an organic inter insulating method, which lead a high brightness of 500cd/cm2.

  • PDF

The Variation of Serum Thyroglobulin Measured after Thyrogen Administration (Thyrogen 투여 후 측정된 Thyroglobulin 농도변화)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.80-83
    • /
    • 2018
  • Purpose Assessment of Serum Thyroglobulin (sTg) value in total thyroidectomy patients having an ablation dose of radioactive iodine indicates remaining cancer or metastasis. Especially, sTg in patients on withdrawal thyroxine or thyrogen administration for radioiodine ablation is an important indicator to determine the direction of further treatment and prognosis. Current guidelines suggest measurement of sTg is performed at 72 hours after the last injection of thyrogen. and assumes that sTg reaches maximum serum levels at that time. The purpose of this study is to evaluate the variation of sTg measured after thyrogen administration. Materials and Methods We compared with sTg performed at 24hours(D0) and 72hours(D2) after the last injection of thyrogen. We reviewed D0 and D2 from 276 patients were divided them into three groups according to ablation dose of radioactive iodine, 5mCi(A group), 30~80mCi(B group) and 100~200mCi(C group). We used T-test for comparison between D0 and D2. sTg was measured in serum using immunoradiometric assay (Tg-plus RIA; BRAHMS, Berlin, Germany). Results There is no critical variation between D0 and D2 in A group(n=100)(P=0.32), The case of increase(D2>D0) is 45, no change(D2=D0) is 23, decrease(D2D0 is 91, D2=D0 is 28, D2D0 is 19, D2=D0 is 2. The biggest increase is 143.6 ng/mL from 98.4 to 242. Conclusion There was a significant difference in the group over 30mCi. and the case of D2>D0 is 45%, 58.7%, 90.5% for each group. therefore, D2 increased as the dose of radioactive iodine increased. Furthermore, the most sTg values of D0 and D2 are variation under 2.0 ng/mL, so reproducibility as well as sensitivity of sTg will be important at values below 2ng/mL.

A Study on Developing Customized Bolus using 3D Printers (3D 프린터를 이용한 Customized Bolus 제작에 관한 연구)

  • Jung, Sang Min;Yang, Jin Ho;Lee, Seung Hyun;Kim, Jin Uk;Yeom, Du Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.61-71
    • /
    • 2015
  • Purpose : 3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. Materials and Methods : RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$ and $V_{95%}$ in treatment plan through Eclipse. Results : Customized bolus production period took about 3 days. The total volume of air gap was average $3.9cm^3$ at the customized bolus. And it was average $29.6cm^3$ at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. Conclusion : The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against the treatment area with irregular surface. However, the air gap between branded bolus and skin was not enough to cause a change in target dose. On the other hand, in the chest wall could confirm that dose decrease for small the air gap. Customized bolus production period took about 3 days and the development cost was quite expensive. Therefore, the commercialization of customized bolus developed by 3D printers requires low-cost 3D printer materials, adequate for the use of bolus.

  • PDF

Relationship between 25-hydroxyvitamin D and metabolic syndrome among Jordanian adults

  • Khader, Yousef S.;Batieha, Anwar;Jaddou, Hashim;Batieha, Zahi;El-Khateeb, Mohammed;Ajlouni, Kamel
    • Nutrition Research and Practice
    • /
    • v.5 no.2
    • /
    • pp.132-139
    • /
    • 2011
  • Evidence of the association between 25-hydroxyvitamin D (25(OH)D) and metabolic syndrome (MeS) remains uncertain and incongruent. This study aimed to determine the association between 25(OH)D and MeS among Jordanian adults. A complex multistage sampling technique was used to select a national population-based household sample. The present report deals exclusively with adults aged > 18 years who had complete information on all components of MeS (n = 3,234). A structured questionnaire was used to collect all relevant information. Anthropometric, clinical, and laboratory measurements were obtained. MeS was defined according to the International Diabetes Federation (IDF) definition. Of the total, 42.0% had MeS and 31.7% had 25(OH)D < 30 ng/ml. In a stratified analysis, the prevalence of MeS did not differ significantly between subjects with low and normal 25(OH)D levels for men and women in all age groups. In the multivariate analysis, the odds of MeS were not significantly different between subjects with low and normal 25(OH)D levels (OR = 0.85, 95% CI: 0.70, 1.05, P-value = 0.133). The association between 25(OH)D and MeS remained non-significant when 25(OH)D was analyzed as a continuous variable (OR = 1.004, 95% CI; 1.000, 1.008, P = 0.057) and when analyzed based on quartiles. None of the individual components of MeS were significantly associated with 25(OH)D level. This study does not provide evidence to support the association between 25(OH)D level and MeS or its individual components. Prospective studies are necessary to better determine the roles of 25(OH)D levels in the etiology of MeS.

Development of OCB mode with impulsive driving scheme for improving moving picture quality

  • Kim, J.L.;Lee, C.H.;Park, S.Y.;Yoo, S.W.;Oh, J.H.;Lee, S.H.;Chai, C.C.;Park, C.W.;Ban, B.S.;Ahn, S.H.;Hong, M.P.;Chung, K.H.;Lim, S.K.;Kim, K.H.;Souk, J.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1049-1052
    • /
    • 2004
  • In general, contrary to the CRTs with impulsive emission, liquid crystal displays have motion artifacts such as blurring. ghost image, decrease of dynamic CR(contrast ratio), and stroboscopic motion due to hold type driving method. In this paper, to improve motion picture quality of LCDs. impulsive driving method of black data insertion was applied to the OCB mode which is well known for its fast LC response time and wide viewing angle properties. Subject evaluation was carried out with CRT, TN, SIPS(Super IPS). and impulsive driving OCB. Moving picture image quality near CRT was obtained in impulsive OCB driving mode

  • PDF

Effects of Soil EC on Seed Germination, Seeding Growth, Initiation of Female Flower and Fruit Growth of Cucumber (Cucumis sativus L.) Plants (토양 EC가 오이의 종자발아, 유묘의 생장, 자화착생 및 과실비대에 미치는 영향)

  • Chung, Hee-Don;Jang, In-Suk;Choi, Young-Jun
    • Horticultural Science & Technology
    • /
    • v.19 no.4
    • /
    • pp.495-500
    • /
    • 2001
  • Seed germination, seedling growth, plant establishment after transplanting, set of female flowers, and subsequent fruit growth were examined in cucumbers grown in soils having varying electrical conductivities (EC) of $1.0-5.0dS{\cdot}m^{-1}$ adjusted by adding different amount of a commercial compound fertilizer (N : $P_2O_5$ : $K_2O$ = 21 : 17 : 17). Slower seed germination was recorded in soils having EC value of $3.0dS{\cdot}m^{-1}$ or higher and little or no germination took place in soils with EC $4.0dS{\cdot}m^{-1}$ until 8 days after sowing. Suppression of seedling growth was apparent in soils having EC level of $2.5dS{\cdot}m^{-1}$. All seedlings died eventually at EC level of $3.5dS{\cdot}m^{-1}$. Leaf color became progressively dark green with the increase in EC from 1.0 to $3.0dS{\cdot}m^{-1}$. The first female flower was formed at higher node and the number of days required for the first flowering of female flower increased with the increase in EC values up to $3.0dS{\cdot}m^{-1}$. Occasionally, leaf yellowing and self-topping symptoms appeared in plants grown in soils having EC level of $3.0dS{\cdot}m^{-1}$.

  • PDF

ON A PROPERTY OF CONVOLUTION OPERATORS IN THE SPACES $D'_{L^{P'}} p{\geq}1 AND \delta'$

  • Park, D.H.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.21 no.2
    • /
    • pp.91-95
    • /
    • 1984
  • Let D$^{p}$ be the space of distributions of $L^{p}$-growth and S the space of tempered destributions in $R^{n}$: D$^{p}$, 1.leq.P.leq..inf., is the dual of the space $D^{p}$ which we discribe later. We denote by O$_{c}$(S:S') the space of convolution operators in S. In [8] S. Sznajder and Z. Zielezny proved the following necessary conditions for convolution operators in O$_{c}$(S:S) to be solvable in S.

  • PDF

Antecedents and Effects of R&D Concentration : An Analysis from the Perspective of the Structure-Conduct-Performance paradigm (연구개발(R&D)집중도의 결정요인 및 영향에 관한 연구 : S-C-P 패러다임 관점에서의 접근)

  • Cho, Young-Gon;Shin, Hyuk-Seung;Sul, Won-Sik
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.3
    • /
    • pp.24-35
    • /
    • 2014
  • This paper examines, from the perspective of the structure-conduct-performance (S-C-P) paradigm, the structural factors that determine R&D concentration in industries. The results are as follows. First, an industry's R&D concentration is directly related to its market concentration, R&D intensity, capital intensity, and technological opportunities. In contrast, the higher an industry's performance, the more likely the diffusion of R&D investment is for firms belonging to that industry. Second, an industry's R&D concentration has a positive effect on its market concentration but a negative effect on its performance, suggesting that governments should adopt R&D policies that would induce more firms to invest in R&D instead of focusing only on a few firms to enhance industry performance.

A CONSTRUCTION OF TWO-WEIGHT CODES AND ITS APPLICATIONS

  • Cheon, Eun Ju;Kageyama, Yuuki;Kim, Seon Jeong;Lee, Namyong;Maruta, Tatsuya
    • Bulletin of the Korean Mathematical Society
    • /
    • v.54 no.3
    • /
    • pp.731-736
    • /
    • 2017
  • It is well-known that there exists a constant-weight $[s{\theta}_{k-1},k,sq^{k-1}]_q$ code for any positive integer s, which is an s-fold simplex code, where ${\theta}_j=(q^{j+1}-1)/(q-1)$. This gives an upper bound $n_q(k,sq^{k-1}+d){\leq}s{\theta}_{k-1}+n_q(k,d)$ for any positive integer d, where $n_q(k,d)$ is the minimum length n for which an $[n,k,d]_q$ code exists. We construct a two-weight $[s{\theta}_{k-1}+1,k,sq^{k-1}]_q$ code for $1{\leq}s{\leq}k-3$, which gives a better upper bound $n_q(k,sq^{k-1}+d){\leq}s{\theta}_{k-1}+1+n_q(k-1,d)$ for $1{\leq}d{\leq}q^s$. As another application, we prove that $n_q(5,d)={\sum_{i=0}^{4}}{\lceil}d/q^i{\rceil}$ for $q^4+1{\leq}d{\leq}q^4+q$ for any prime power q.

Reduction in the contents of acetaldehyde, methanol and fusel alcohols in the Muscat Bailey A wine fermented by Korean indigenous sugar-tolerant yeasts Saccharomyces cerevisiae S13 and D8 (토착형 아황산 및 당 내성 효모 Saccharomyces cerevisiae S13과 D8에 의한 Muscat Bailey A 포도주의 아세트알데히드, 메탄올 및 고급알코올의 감소 효과)

  • Kim, Mi-Sun;Park, Heui-Dong
    • Food Science and Preservation
    • /
    • v.21 no.6
    • /
    • pp.851-858
    • /
    • 2014
  • Muscat Bailey A (MBA) wine was fermented using the indigenous Korean Saccahromyces cerevisiae strains S13 and D8, and the fermentation characteristics were compared with those of S. cerevisiae W-3, an industrial wine yeast. The strains S13 and D8 showed delayed alcohol fermentation compared with the W-3 strain, but the final alcohol contents of the S13 and D8 wines after fermentation were similar to those of the W-3 wine. The S13 wine showed significantly lower malic-acid content than the W-3 wine, but the D8 wine showed a similar level. Both the wines fermented using the S13 and D8 strains showed significantly lower acetaldehyde, methanol, and fusel oil contents, including n-propanol, iso-butyl alcohol, and iso-amyl alcohol, compared to the W-3 wine. Especially, the methanol content was 98.6 mg/L in the S13 wine and 112.0 mg/L in the D8 wine, which were much lower than 192.8 mg/L in the W-3 wine. The S13 wine obtained the highest score in terms of color among the three wines in the sensory evaluation, with lower Hunter's L, a, and b values compared to the W-3 wine.