• Title/Summary/Keyword: $Cr^{4+}$:YAG 레이저

Search Result 20, Processing Time 0.024 seconds

The saturating property of $Cr^{4+}:YAG$and dye film as the saturable absorber (포화흡수체 $Cr^{4+}:YAG$와 유기염료 박막의 포화특성 분석)

  • 최영수;전용근;김재기
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.98-102
    • /
    • 2001
  • To analyze the saturating process of $Cr^{4+}:YAG$ crystal and plastic organic dye as the saturable absorber, we have measured the residual optical losses between a free running and a passive Q-switching mode for various optical densities. The undepleted ground state population density and the saturated transmission of the saturable absorber have been evaluated by the additional optical losses with the increased threshold pump energies between two resonators. ill the passive Q-switching mode, the saturable transmission of saturable absorber is less than the maxrnium saturable transmission due to the undepleted ground state population density. nsity.

  • PDF

Generation of Femtosecond Pulses in a Passively Mode-Locked 100 MHz Cr4+:YAG Laser (수동 모드 잠금된 100 MHz Cr4+:YAG 레이저에서의 펨토초 펄스 발생)

  • Cho, Won-Bae;Rotermund Fabian;Kim, Jong-Doo;Jeon, Min-Yong;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.535-541
    • /
    • 2005
  • We report on the development of a passively mode-locked near-infrared femtosecond laser with Cr:YAG crystal that operates near room temperature. The laser wavelength could easily be tuned by using only the internal prism pair over 110 nm from 1400 nm to 1510 nm in cw and over about 30 nm in mode-locked operation, respectively Maximum cw output powers of 810 mW were obtained with $1.5 \%$ output coupler for absorbed pump powers of 7.6 W. For compensation of the internal group velocity dispersion, an IR graded prism pair was used. The Cr:YAG laser delivered nearly Fourier-transform limited pulses with a pulse duration as short as 64 fs at 100 MHz repetition rate. In the mode-locked regime, the laser was operating at 1510 nm with a spectral bandwidth of 44 nm. In order to avoid unstable mode-locking and power instabilities, self-built tubes were inserted into the beam path in the resonator and purged with N2 gas. Finally, output powers of the Cr:YAG laser were optimized to 250 mW fer long time stable mode-locked operation.

Construction and operational characteristics of a Ultra-Short pulse Cr4+:YAG laser (극초단 펄스 Cr4+:YAG 레이저의 제작 및 동작 특성)

  • Lee Bong Yeon;Lee Dong Han;Lee Chi Weon;Yoon Seok Beom;Choo Han Tae
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.455-460
    • /
    • 2004
  • We have developed a mode-locked ultra-short pulse C $r^{4+}$:YAG laser, as well as a continuous wave C $r^{4+}$:YAG laser. The laser was pumped by a Nd:YAG laser and its characteristics were investigated. In continuous wave mode, we obtained as much as 600 mW at 1.436 ${\mu}{\textrm}{m}$ with pumping power of 6 W, by using an output coupler with a reflectivity of 98%. The power slope efficiency was 10%, when the gain medium was cooled to 19$^{\circ}C$. The tuning range was varied from 1.39 ${\mu}{\textrm}{m}$ to 1.55 ${\mu}{\textrm}{m}$ and the maximum power was 400 mW at 1.492 ${\mu}{\textrm}{m}$ with a 3-plate birefringent filter. The C $r^{4+}$:YAG laser was mode-locked by a Kerr lens mode locking method. Mode locking at 1.436 ${\mu}{\textrm}{m}$was initiated by slightly rocking a mirror mount. But the pulses were very unstable because of the strong water absorption at this region. So we shifted the lasing wavelength to 1.492 ${\mu}{\textrm}{m}$ by using a 3-plate birefringent filter. Then we obtained stable state mode-locking with the maximum average power of 280 mW for a pumping power of 6 W. The pulse width of 43 fs was measured using an autocorrelator and the repetition rate was 104.5 MHz.

Development of Laser Typing Process for the High Density Recording (고밀도 기록을 위한 레이저 타이핑 공정 개발)

  • 주영철;송오성;정영순
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.317-321
    • /
    • 2003
  • A conventional typewriter types letters by hammering a carbon ribbon which is attached at a paper. The laser typing process which write a micro pattern of Chrome on a silicon wafer has been developed. A glass that is coated with 100 nm Chrome (Carbon ribbon) is attached on a silicon wafer (paper). An Nd-Yag laser (hammer) is irradiated on the glass, and the Chrome is transferred on the silicon wafer. Micro patterns are made by controlling laser beam trajectory. The suggested micro pattering can be used at the high density data storage of TeraBit/in$^2$ or at the improvement of productivity of semiconductor manufacturing procedure.

  • PDF

눈에 안전한 $1.57\mum$ OPO 광원 개발

  • Song, Dae-Chan;Park, Jong-Dae;Jo, Chang-Ho
    • The Journal of Natural Sciences
    • /
    • v.14 no.2
    • /
    • pp.25-31
    • /
    • 2004
  • 레이저 거리 측정기나 화생탐지 라이다용으로 사용할 수 있는 눈에 안전한 적외선 레이저 광원을 개발하였다. 펌프레이저로는 소형 플래쉬 램프로 구동되는 Nd:YAG 레이저를 사용하였으며, OPO(Optical Parametric Oscillator) 결정으로는 Flux 성장된 KTP를 사용하였다. OPO 송진기는 레이저 공진기 내부에 설치하여 비선형 광학 현산에 의한 파라메트릭 발진이 쉽게 일어나도록 하였다. 효율적인 파라메트릭 발진을 위해서 Type II 비임계 위상정합$(\theta=90^{\circ},\;\phi = 0^{\circ})$을 사용하여 공진기를 구성하였다. Nd:YAG 레이저는 Cr:YAG 결정을 사용하여 수동형 큐-스위칭 되었으며 OPO 출력은 1mJ 정도이었다. OPO 펄스폭은 4ns로서 수동형 큐스위칭 레이저 펄스폭보다 20% 정도로 작았다. OPO 출력의 펄스폭이 펌프레이저의 펄스폭 보다 작은 것은 이론적 계산을 통하여 확인할 수 있었다.

  • PDF

Effect of the Thermal Lensing on stable Region, Beam Waist and Astigmatic Compensation of Z-fold Cr4+ : YAG laser Cavity (Cr4+ : YAG 레이저에서 열 렌즈 효과에 따른 공진기의 안정영역과 빔 허리 및 비점수차의 보상)

  • Lee, Bong-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.447-454
    • /
    • 2006
  • We obtained analytic solutions of boundary conditions to the stable region of Z-fold $Cr^{4+}$ : YAG laser cavity when the conditions are with and without thermal tensing effect. Also we investigated the influence of the thermal tensing effect on the stability of cavity, beam waist, and astigmatic compensation using aberration transformation matrices. The thermal tensing effect almost has no influence on the stable region of the cavity when the crystal is located in the middle of two concave mirrors and when the distances from the concave mirror to the reflecting mirror and the output coupler are the same. The beam waist, however, is affected more in a tangential plane than in a sagittal plane, and so it is difficult to have astigmatic compensation when the thermal tensing effect exists. This result means that the thermal tensing effect should be considered even for the Kerr-lens mode-locking.

Effects of laser-irradiated dentin on shear bond strength of composite resin (레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향)

  • Kim, Sung-Sook;Park, Jong-Il;Lee, Jae-In;Kim, Gye-Sun;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.520-527
    • /
    • 2008
  • Purpose: This study was conducted to evaluate the shear bond strength of composite resin to dentin when etched with laser instead of phosphoric acid. Material and methods: Recently extracted forty molars, completely free of dental caries, were embedded into acrylic resin. After exposing dentin with diamond saw, teeth surface were polished with a series of SiC paper. The teeth were divided into four groups composed of 10 specimens each; 1) no surface treated group as a control 2) acid-etched with 35%-phosphoric acid 3) Er:YAG laser treated 4) Er,Cr:YSGG laser treated. A dentin bonding agent (Adapter Single Bond2, 3M/ESPE) was applied to the specimens and then transparent plastic tubes (3 mm of height and diameter) were placed on each dentin. The composite resin was inserted into the tubes and cured. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours and the shear bond strength was measured using a universal testing machine (Z020, Zwick, Germany). The data of tensile bond strength were statistically analyzed by one-way ANOVA and Duncan's test at ${\alpha}$= 0.05. Results: The bond strengths of Er:YAG laser-treated group was $3.98{\pm}0.88$ MPa and Er,Cr:YSGG laser-treated group showed $3.70{\pm}1.55$ MPa. There were no significant differences between two laser groups. The control group showed the lowest bond strength, $1.52{\pm}0.42$ MPa and the highest shear bond strength was presented in acid-etched group, $7.10{\pm}1.86$ MPa (P < .05). Conclusion: Laser-etched group exhibited significantly higer bond strength than that of control group, while still weaker than that of the phosphoric acid-etched group.

The Effect of ER:YAG Laser & ER,CR:YSGG Laser on the Tissue of the Inflammation-Induced Mouse (Er:YAG 레이저와 Er,Cr: YSGG 레이저가 염증유발 마우스조직에 미치는 영향)

  • Park, Tae-Il;Lee, Hyung-Seok;Lee, Hee-Jong;Chae, Chang-Hoon;Lee, Young-Joo;Byeon, Kwang-Seob;Hong, Soon-Min;Choi, Mee-Ra;Park, Jun-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.396-405
    • /
    • 2010
  • Purpose: This study was performed to find out the effects of the Er:YAG laser (Key Laser) & Er,Cr:YSGG laser (Water Laser) on inflammatory tissues. Materials and Methods: It was performed on about 20 g, 6 weeks male ICR mouses. They were grouped into the control (negative), the inflammation induced 'control'(positive), Er,Cr:YSGG laser exposured group after inducing inflammation, Er:YAG lasere exposured group after inducing inflammation each 15 mouses. The mouses were applicated 0.5% DNFB 1 cc on ear skin twice a day for 4 days until symptom expression. After laser exposure, ear tissues were extracted and defined gene expression by RT-PCR. Then, tissue staining, lymphocytes observation, electromicroscophic laboratory were carried out. Results: Interleukin-$1{\beta}$ was expressed much less in the A-laser exposed group. Interleukin-$1{\beta}$ & Tumor Necrosis Factor-${\alpha}$ were expressed 7 times lesser in the A-laser exposed group. The number of Lymphocytes related to inflammation was decreased rapidly in the A-laser exposed group in vivo. he number of cavity recovered normal was a little bigger in the A-laser exposed group after 5 days Conclusion: The expression of IL-$1{\beta}$ & TNF-${\alpha}$, hitologic change, observation with electron microscope shows that Erbium laser exposure causes lesser inflammation with A-laser rather than B-laser.

A STUDY ON THE EFFECT OF PULSED Nd : YAG LASER IMPACTS TO THE ENAMEL SURFACE AND BOND STRENGTH WITH COMPOSITE RESIN (Nd : YAG레이저 조사시(照射時) 치아(齒牙) 법랑질(琺瑯質)의 변화(變化) 및 접착력(接着力)에 관(關)한 연구(硏究))

  • Park, Jong-Man;Bae, Tae-Seong;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.85-101
    • /
    • 1991
  • The purpose of this study was to determine the optimum range of laser energy density to the enamel surface of permanent incisors when they are irradiated with the pulsed Nd : YAG laser, Laser impacts on each experimental group were made at energy density of $20\sim50J/cm^2$ by 20 pulses of the pulse width 1.2 msec. The author investigated the enamel surface with the sunning electron microscope(SEM) and the surface roughness tester, and measured the shear bond strength between electrolytically etched Ni-Cr-Be alloy casting and composite resin. The obtained results were as follows: 1. The surface roughness of enamel after laser irradiation showed the significant difference level from the energy density $40J/cm^2(P<0.05)$. 2. The mean shear bond strength of etched-metal resin-bonded specimens were $154.23{\pm}33.30kg/cm^2$ at unlased enamel surface and $195.72{\pm}29.56kg/cm^2$ at lased energy density $30J/cm^2$, and showed a significant difference(P<0.05). 8. SEM photographs showed the irregular microcracks and the structural changes of lased enamel surface. 4. SEM photographs of the fracture surface after testing the shear bond strength showed the aspect of interfacial fracture between bonding agent and composite resin at the metal sides.

  • PDF

A Study on a KTP Crystal Laser System for a Cancer Using P.D.T. (KTP 크리스탈을 이용한 PDT용 레이저 시스템 개발)

  • Kim, Byoung-Mun;Nam, Hyo-Duk;Kim, Byoung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.631-634
    • /
    • 2004
  • The method that exists in Photodynamic Therapy uses Photosensibility drug strongly Influencing tumour accumulation together with photochemical laser effect and makes the structure of tumour be localized and become extinct. The intracavity transformation of the Nd :YAP main radiation 1079 nm was Raman converted in barium nitrate crystal and the Stokes frequency (1216 nm) was doubled using KTP or RTA crystals. The LiF or Cr:YAG crystals are used for the Q-switch. The radiation Parameters were obtained at 100 Hz pump repetition frequency. The average power at 608 nm radiation with LiF and KTP was 700 mW at multi-mode generation. The 3-6 single 10-15 ns pulses were generated during one cycle of pumping. The doubling efficiency with RTA was two times more than with KTP. The cells of Ehrlich adenocarcinoma (0.1 ml) were i.m. implanted in hind thighs of ICR white non-imbred mice. The cells were preliminarily diluted in medium 199 in the ratio of 1 to 5. HpD was intravenous administered in a dose of 10 mg/kg. The left clean-shaven hind leg was irradiated with laser light 21-27 hours after the administration of the preparation. The right non-Irradiated leg of each animal served as a control. The animals with the transplanted tumor that were not injected with HpD sewed as a control to estimate the complex effect (HpD+ irradiation). Before the administration of HpD and on 3 and 4 days after irradiation the tumor size was measured and the percent of the tumor growth inhibition was calculated. The results of animal treatments has shown high efficiency of PDT method for cancer treatment by means 0.608 m high power pulse solid state laser.

  • PDF