• Title/Summary/Keyword: $Cr(CO)_x$

Search Result 222, Processing Time 0.029 seconds

Enhancement of Wear Resistance of CoCrNiAlTi Plasma Sprayed Coatings Using Titanium Carbide

  • De-Yong Li;Chul-Hee Lee
    • Tribology and Lubricants
    • /
    • v.39 no.1
    • /
    • pp.13-20
    • /
    • 2023
  • Large drill bits may face high hardness ore and high working pressure when working. To optimize the use effect of large drill bits and prolong the use time, it is necessary to add a layer of pressure-resistant, wear-resistant, and low-friction coating on the surface of the drill bit. In this study, CoCrNiAlTi high-entropy alloy coatings and CoCrNiAlTi (70 wt%)-TiC (30 wt%) composite coatings are successfully prepared on Q235 steel by plasma spraying. The CoCrNiAlTi (70 wt%)-TiC (30 wt%) coating consists of FCC solid solution and a small amount of TiC phase. The effect of TiC on the composition phase, microhardness, and elastic modulus of HEA coating is studied by X-ray diffractometer (XRD) and microhardness tester. The effect of TiC on the friction and wear properties of HEA coatings is investigated using a wear tester. By improving the process parameters, the metallurgical bonding between the coating and the substrate is well combined, and a coating without pores and cracks is obtained. The experimental results confirm that the microhardness, elastic modulus, and wear resistance of CoCrNiAlTi-TiC composite coating are better, and the friction coefficient is lower.

The Sensor Response for CO Gas of $LaMO_3$ and $LaFe_{1-x}CO_xO_3$ in Perovskite Type Oxides (Perovskite형 산화물 $LaMO_3$$LaFe_{1-x}CO_xO_3$의 일산화탄소가스에 대한 센서 응답 특성)

  • 임병오;손태원;권동혁
    • Journal of the Korean Society of Safety
    • /
    • v.3 no.1
    • /
    • pp.7-13
    • /
    • 1988
  • The oxides in perovskite type, $LaMO_3$ (M=Ni, Cr, Fe, Co), compared with gas sensors which have been used, were synthesised and then examined sensor response comparatively in order to make a thick film gas sensor having a good gas selectivity, durability and simple manufacturing. The oxides in perovskite type, $LaFe_{1-x}O_3$ (x=0.2, 0.4, 0.6, 0.8), which a part of Fe was replaced with Co, were examined with regard to their electric resistance with variable temperature and sensor response for carbon monoxide gas.

  • PDF

Material Degradation of 2Cr and 12Cr Tube Steels for High Temperature and Long-Time Exposure (2Cr 및 12Cr 크롬강튜브의 고온 장시간 사용에 따른 열화현상)

  • Choe, Byung-Hak;Lee, Gil Jae;Kim, Sang-Ho;Hong, Key-Yong;Kim, Woo Sik;Baek, Un Bong;Nahm, Seung Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.28-34
    • /
    • 2012
  • Material degradation of Cr steels in using for boiler tubes was studied in the relation of microstructural changes like carbide behavior and mechanical properties of hardness and creep-rupture life. The carbide dissolution was occurred in 2Cr steel of T22 during high temperature operation. And the grain refinement within martensite lath of 12Cr steel of X20 was derived by the high temperature-long time exposure. But the specific phenomena of material degradation which might be represented by hardness or creep-rupture time of the used tubes were not shown in all the tubes of T22 and X20 even in the fire-side using.

Growth of Synthetic Emerald Single Crystal by Flux Method (Flux법에 의한 합성 에메랄드 단결정 육성)

  • Park, Sun-Min;Lee, Chul-Tae;Kim, Ho-Kun
    • Applied Chemistry for Engineering
    • /
    • v.7 no.1
    • /
    • pp.34-42
    • /
    • 1996
  • Growth of synthetic emerald [($(BeO)_3(Al_{2-x}Cr_xO_3)(SiO_2)_6$] single crystals was carried out by flux method. In this study, the starting materials were prepared by stoichiometric mixing of BeO, $Al_2O_3$ and $SiO_2$ as reaching components. The conditions for the growth of synthetic emerald single crystals are as follows : temperature range ; $1150{\sim}900^{\circ}C$, cooling rate ; 2, 4, $10^{\circ}C/hr$, flux ; $Li_2CO_3$, $V_2O_5$, dopant ; $Cr_2O_3$. The sizes of $Cr_2O_3$emerald single crystals depending on 2, 4, $10^{\circ}C/hr$ cooling rates. The obtained emerald single crystal was characterized and the following results were obtained : lattice parameter : a=0.921nm, c=0.917nm, crystal system ; hexagonal, crystal size ; max. $0.80{\times}0.95mm^2(c{\times}m)$, orientation ; (1000), $m(10{\bar{1}}0)$.

  • PDF

Effect of Trace Metallic Additives of Al-Fe-X on Microstructure and Properties of Zn Electrodeposits (아연도금층의 조직 및 물성에 미치는 미량금속원소(Al-Fe-X)의 복합첨가의 영향(I))

  • 예길촌;김대영;서경훈;안덕수
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.6
    • /
    • pp.444-454
    • /
    • 2003
  • The effect of trace metallic additives of Al-Fe-X on microstructure, glossiness and hardness of Zn electrodeposits was investigated by using sulfate bath. The preferred orientation of Zn deposits with Al-Fe additives was (10 l)(l:3,4,2), while that of Zn deposits with Al-Fe-X(Ni,Co) additives was either (002) or (002)+(103)ㆍ(104) mixed orientation. The preferred orientation of Zn deposits with Al-Fe-Cr additives changed from (002)+(10 l) to (10 l) orientation with increasing amount of Al additive. The surface morphology of the Zn deposits was closely related to the preferred orientation of the deposits. The glossiness of Zn deposits with Al-Fe additives increased in comparison with that of pure Zn deposit. That of the Zn deposits with Al-Fe-X additives was related to the morphology of the deposits and changed according to type of additives. The hardness of Zn deposits with Al-Fe-X(Ni,Co,Cr) additives was noticeably higher than that of Zn deposits with Al-Fe additives.

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

Contamination structure and process on SUS 316 under UHV, HV and air (초고진공, 고진공, 대기압에서 SUS 316의 오염 구조와 오염 과정 연구)

  • 서지근;이규장;신용현;홍승수;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 1997
  • The contamination structure and process on SUS 316 under various exposure conditions were investigated using x-ray photoelectron spectroscopy. The metal-oxide, metal-H-oxides, CO, COH, and $C_xH_y$ are the main components of contaminants on the SUS surface. The compositional profiles of the contaminants are shown to be $C_xH_y$/CO(COH)/metal-oxide on SUS. The contamination proceeds in two steps. The oxidation of the metallic constituents followed by adsorption of hydrocarbons. Under UHV conditions the contamination is mainly due to the oxidation, and, as the exposure time increases, the oxidation continues. In HV or higher pressure, most of the oxides are formed almost immediately after exposure and as the exposure time increases the contamination of hydrocarbons continues to grow. For the SUS sample exposed to atmosphere, the metal oxide is distributed deep inside the surface with an exponentially decreasing concentration, and its thickness is nearly in the order of photoelectron mean free path. It is also seen that the Fe oxide is segregated over Cr oxide in the highly oxidized samples.

  • PDF

Structural and Magnetic Properties of Epitaxial FexCo100-x Alloys Grown on Cr Substrate

  • Hossain, M.B.;Kim, C.G.;Chun, B.S.;Kim, W.D.;Hwang, C.
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.1-4
    • /
    • 2014
  • We report the correlation between the magnetic properties and lattice parameter of $Fe_xCo_{100-x}$ alloys as a function of constituent concentration. The saturation magnetization increases with Fe content and has a maximum value at approximately x=70 at.%. However, collapse in relative saturation magnetization is observed at approximately 30 at.% to 70 at.% of Fe in $Fe_xCo_{100-x}$ alloys. The collapse is due to the formation of Co-Co and Fe-Fe antibonding states instead of Fe-Co bonds. The lattice parameter also shrinks at approximately 30 at.% to 70 at.% of Fe. This shrinkage is due to an increase in the number of nearest neighbor antisite atoms, which then leads to a decrease in the long range order parameter.

The effect of CR-CO discrepancy on cephalometric measurements in Class III malocclusion patients (골격성 III급 부정교합자에서 중심위 변위가 두부 방사선 계측치에 미치는 영향)

  • Park, Yang-Soo;Kim, Jong-Chul;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.255-265
    • /
    • 1996
  • The purpose of this study was to investigate if there were a significant difference between cephalometric measurements of mandibular position derived from a centric occlusion tracing compared to those of a converted centric relation tracing in the Class III malocclusion. The sample consisted of 25 Class III malocclusion and 25 normal occlusion persons who had no orthodontic treatment. The records included an lateral cephalometrics in centric occlusion, centric relation and centric occlusion bite registration and diagnostic casts mounted on the SAM II articulator in CR. The amount of CR-CO discrepancy of condyle was recorded using a MPI(Mandibular Position Indicator, MPI $200^{(R)}$, Great Lakes Orthodontics, USA). The conversion of the CO cephalogram to CR using the MPI readings was performed on the Conversion work sheet. Measures of mandibular position were chosen for the purpose of this study. The comparison of the difference between CO and CR cephalometric measurements in the normal occlusion and Class III malocclusion group were studied. The results were as follows: 1. In the features of CR-CO discrepancy of the condyle, the condyle was displaced posterior and inferior when the teeth were in centric occlusion. The horizontal component(${\Delta}X$) in Class HI malocclusion group was greater than the vertical component(${\Delta}Z$) and also greater than the horizontal component(${\Delta}X$) in normal occlusion group. There was no statistically significant correlation between MPI measurements and the groups of normal occlusion and Class III malocclusion group. 2. In the comparison of the cephalometric measurements in each group, Normal occlusion group showed significant difference in measurements such as ANB, Facial angle, Facial convexity and ODI. Class HI malocclusion group showed significant difference in measurements such as ANB, Facial angle, Facial convexity, ODI, SNB, APDI, L1-FP and it had more significance than the normal occlusion group. 3. The Value of cephalometric measurements was significantly different between CO and CR but there were no differences between the groups of normal occlusion and Class III malocclusion. The results of this study suggest that if the discrepancies are greater than the amount of normal displacement from clinically captured centric relation, centric relation should be considered as the starting point for proper diagnosis and treatment planning.

  • PDF