• 제목/요약/키워드: $CO_2$ supply

검색결과 765건 처리시간 0.027초

AC Chopper 3전극 방식의 듀티비에 따른 $CO_2$ 레이저 출력 특성에 관한 연구 (A Study on the Output Characteristics of AC Chopper Duty-Ratio $CO_2$ Laser System using 3 Electrode-type and Ring Blower)

  • 박성준;정현주;김근용;이유수;김휘영;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1697-1699
    • /
    • 2001
  • In this paper, the circuit of AC Choppers for $CO_2$ laser power supply are proposed and investigated. IGBT-controlled ac voltage regulators, operating at high frequency chopping mode. Chopping-to-supply duty ratio plays an important role in terms of laser output. Laser input energy is varied by controlling the leakage transformer used with the proposed system. This improved circuit employs a 3 electrode - type and Ring Blower. This improved circuit system has many advantages compared with the conventional SMPS such as simple design requirement, easy implementation, high reliability, low switching loss, and consequently high efficiency. As a result, the maximun output was 16W at duty-ratio of 92%, total gas mixture of $CO_2$ : $N_2$ : He = 1 : 9 : 15, total pressure of 15torr.

  • PDF

배터리 충방전특성을 고려한 제주계통의 적정 ESS용량과 탄소배출량 산정에 관한 연구 (A Study on the Evaluation of the ESS Capacity of Considering for Charge-Discharge Characteristic and CO2 Emission in Jeju)

  • 구본희;차준민
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.455-460
    • /
    • 2014
  • South Korea's power consumption is increasing every year. For stable electric power supply, more generation facilities are needed. But it is not easy to build nuclear power generation facilities, so provision of renewable energy is thought of as the solution. For the system's stable management, practical use of energy storing system is needed. Currently, pumping up electric power station is considered most useful. In this study, we have calculated the least amount of energy storing device by considering the renewable energy, HVDC, and change in power for the appliance of ESS in Jeju system, according to The 6th Basic Plan for Long-term Electricity Supply and Demand. Also we have calculated the amount of the battery and about the load equalizing effect to use battery as power storing device. Finally, we have calculated the reduction of electricity generation and the reduction of $CO_2$ emission with this study.

An Experimental Study of Ventilation Effectiveness in Mechanical Ventilation systems using a Tracer Gas Method

  • Lee, Jae keun;Kang, Tae-Wook;Lee, Kam-Gyu;Cho, Min-Chul;Shin, Jin-Hyuk;Kim, Seong-Chan;Koo, Jeong-Hwan;Lee, Jong ho
    • Journal of Mechanical Science and Technology
    • /
    • 제14권11호
    • /
    • pp.1286-1295
    • /
    • 2000
  • The ventilation effectiveness is evaluated as a function of air exchange rate and supply / extract locations in a simplified model chamber using a tracer gas technique of CO$_2$ gas injected into a supply duct. Ventilation systems consist of supply and extract fans, a CO$_2$gas generator, a CO$_2$gas analyzer and a test chamber. The ventilation effectiveness is evaluated using a step-down method based on ASTM Standard E741-83. The room mean age of the model chamber is decreased with increasing air exchange rate fanged from 6to 10 air changes per hour. The ventilation effectiveness of the mechanical inlet/natural extract system is better than that of the mechanical extract system.

  • PDF

누설 변압기를 이용한 반파 AC 주파수 제어형 $CO_2$ 레이저의 전원장치 개발 (The development on Power supply for Pulsed $CO_2$ laser using half-rectified AC frequency control and leakage transformer)

  • 정현주;김도완;이동훈;이유수;김희제;조정수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.82-85
    • /
    • 2000
  • We introduce pulsed $CO_2$ laser power supply excited by half-wave rectified 60Hz AC discharge some advantage of cost and size compared to a typical pulsed power supply. AC frequency is adjusted from 10Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage AC discharge circuits is employed to avoid the HV sampling or switching. The control is achieved by using a ZCS circuit and a PIC one-chip microprocessor that control the gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to a high leakage inductance. The maximum laser output was obtained about 20W at the condition of total pressure, 18Torr and pulse repetition rate,60Hz.

  • PDF

A Study on the Adjusting Output Energy of the $CO_2$ Laser Controlled Directly in AC Power Line

  • Noh, Ki-Kyong;Jeong, Jong-Jin;Chung, Hyun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권4호
    • /
    • pp.152-154
    • /
    • 2005
  • We demonstrate a simple $CO_2$ laser by controlling firing angle of a TRIAC switch in ac power line. The power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply does not need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. In order to control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of TRIAC gate is varied from $45^{circ}$ to $135^{circ}$. A ZCS(Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control the gate signal of the TRIAC precisely. The maximum laser output of 40W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60Hz, and a TRAIC gate firing angle of $90^{circ}$.

상하수도시설에 대한 전과정관리(LCM)시스템 구축방안 연구 (Establishment of Life Cycle Management(LCM) System for Water Supply and Sewerage Systems)

  • 박지형;황용우;김영운;박광호
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.303-312
    • /
    • 2012
  • Water supply and sewerage systems are the large-scale urban infrastructure ejecting large amount of environmental load over the life-cycle. Therefore, it is important not only to optimize in the aspect of economical superiority and process efficiency but also to consider earth scale environmental impact. This study aimed to suggest the establishment of life cycle management(LCM) system as an integrated management solution in urban water supply and sewerage systems. As a result, the methodology for LCM system consisting of life cycle assessment(LCA), life cycle cost(LCC), life cycle $CO_{2}(LCCO_{2})$ and life cycle energy(LCE) was developed. Also, several case studies using the latest statistics data of water supply and sewerage systems were carried out to investigate the field applicability of LCM.

고주파 공진현상을 이용한 CW CO2 레이저의 출력리플 최소화 (Minimization of a CW CO2 Laser Output Ripple by using High Frequency Resonance Phenomena)

  • 사쿠라;권민재;김희제;이동길;허국성
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.798-802
    • /
    • 2013
  • In a conventional DC power supply used for CO2 laser, the circuit elements such as a rectifier bridge, a current-limiting resistor, a high voltage switch, energy storage capacitors ans a high-voltage isolation transformer using high turn ratio are necessary. Consequently, those supplies are expensive and require a large space. Thus, laser resonator and power supply should be optimally designed. In this paper, we propose a new power supply using high frequency resonance phenomena for CW(Continuous wave) CO2 laser (maximum output of 23W with discharge length of 450mm). It consists of a transformer including leakage inductance, magnetizing inductance and half-bridge converter, a three-stage Cockcroft-Walton and PFC(Power factor correction) circuit. The output ripple voltage can be controlled the minimum of 0.24% under the high frequency switching of 231kHz. Furthermore, the output efficiency was improved to 16.4% and the laser output stability of about 5.6% was obtained in this laser system.

Response of Soybean to Elevated $\textrm{CO}_2$ Concentrations and Temperatures at Two Levels of Nitrogen Application

  • Kim, Hong-Rae;Song, Hong-Keun;Lee, Sun-Joo;Kim, Seung-Hyun;Han, Sang-Joon;Ahn, Joung-Kuk;Chung, Ill-Min
    • 한국작물학회지
    • /
    • 제49권2호
    • /
    • pp.73-81
    • /
    • 2004
  • Effects of ambient and elevated $\textrm{CO}_2$ and high temperature, and their interactions with zero and applied nitrogen supply (NN-no nitrogen and AN-applied nitrogen) were studied on soybean (Glycine max L.) in 2001. In this experiment, elevated $\textrm{CO}_2$ (650 $\mu\textrm{mol}.\textrm{mol}^{-1}$) and temperature (+$5^{\circ}$) increased total dry mass at final harvest by 125% and 119% and seed weight per plant by 57% and 105% for NN and AN plants, respectively. Although the influence of temperature and temperature x $\textrm{CO}_2$ were not significant, the influences of $\textrm{CO}_2$ concentration and temperature x $\textrm{CO}_2$ concentration were significant on total dry weight and seed weight, respectively. In particular, seed weight per plant was increased, while weight per one hundred seed weight was decreased with elevated $\textrm{CO}_2$ and temperature. The N supply increased biomass and seed weight per soybean plants. The results of this study suggest that the long-term adaptation of soybean growth at an elevated $\textrm{CO}_2$ concentration and high temperature might potentially result in a increase in dry matter production and yield.

세대간 동거와 기혼여성의 노동공급 (Co-residence and Its Effect on Labor Supply of Married Women)

  • 성지미;차은영
    • 노동경제논집
    • /
    • 제24권1호
    • /
    • pp.97-124
    • /
    • 2001
  • 자녀양육에 수반되는 시간적 금전적 비용부담이 기혼여성의 노동시장 진입과 경력단절에 가장 큰 영향을 미치는 요인으로 지적한 선행 연구들은 이에 대한 정책적 지원을 강조하였다. 사회복지정책이 발달한 국가에서 세대간 동거(co-residence)는 고령층의 의료 및 부양과 관련된 공적 비용을 사적 비용으로 전환하고, 공식적인 부양을 비공식적인 것으로 대체하는 동시에 기혼여성의 노동공급을 증가시킨다는 관점에서 정책 설정에서 주요한 개선방안으로 인식되고 있다. 본 연구는 "한국노동패널" 2차년도(1999) 자료를 이용하여 부모세대와의 동거상태, 부모 및 기혼여성 본인의 건강상태가 기혼여성의 노동공급에 미치는 영향을 살펴본다. Tobit모형의 추정 결과, 동거 여부, 여성노인과의 동거, 노동시장 근로를 하지 않는 여성노인과의 동거는 동거하는 노인의 건강상태에 관계 없이 기혼여성의 노동공급량에 정(+)의 효과를 미치는 것으로 나타났다. 세대간 동거는 세대간 사적 자원이전 (intergenerational private transfer of resources)을 통하여 기혼여성의 노동공급에 긍정적인 영향올 미치며, 이는 세대간 사적 자원이전이 여성노인을 중심으로 시간자원의 이전이라는 형태를 취하고 있음을 의미한다.

  • PDF

초고층 공동주택의 환기효율 개선에 관한 연구 (A Study on the Improvement of Ventilation Effectiveness in High-rise Apartment Buildings)

  • 박진철
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.87-94
    • /
    • 2006
  • The efficiency of ventilation system is one of the most important issues of designing ventilation in high-rise apartment buildings. The purpose of this study is to analyze the ventilation efficiency of ventilation system by experimental study using CO2 gas method. The results of this paper can be summarized as follows; (1) An appropriate ventilation including opening planning, mechanical and hybrid system are required. (2) The supply diffuser of ventilation system should be located near the contaminant source. (3) The return grill should be located along with supply diffuser for proper ventilation. and the return grill should be located near or right above the contaminant source. (4) However, the supply location right above the contaminant source has to be avoided. and the supply diffuser should be installed in module with return grill increase ventilation effectiveness.