• Title/Summary/Keyword: $CO_2$ response

Search Result 1,561, Processing Time 0.038 seconds

Development of Fast-Response CO2 Analyzer and Analysis of Engine-out Emission during Cold Start of SI Engine (고속응답 CO2 분석기의 제작 및 이를 이용한 SI엔진에서의 실시간 배기가스 분석에 관한 연구)

  • Song, Hyun-Soo;Park, Kyoung-Seok;Park, Dong-Sun;Min, Kyoung-Doug
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.2
    • /
    • pp.133-140
    • /
    • 2009
  • A fast-response $CO_2$ analyzer has been developed for measuring the $CO_2$ concentration during transient condition of a SI engine. The analyzer consists of the non-dispersive infrared absorption method, electrical chopping system and water cooling system. The analyzer has good repeatability, linearity and permissible drift characteristic. Besides, it showed 18ms of a response to measure the $CO_2$ concentration. The fast-response $CO_2$ analyzer was applied to a single cylinder SI engine and the $CO_2$ emission was examined during engine start. Simultaneously, the standard exhaust gas analyzer, which has slow response time, was used for confirming the accuracy of the exhaust gas analysis using the fast-response $CO_2$ analyzer. The developed analyzer showed much faster responsive characteristic than that of a standard analyzer and made cycle by cycle exhaust gas analysis possible. The transient engine operating characteristics will be estimated from the $CO_2$ concentration of engine-out emissions and engine operating variables.

Development of Fast-Response $CO_2$ Analyzer and Analysis of Engine-out Emission during Transient Condition of SI engine (고속응답 $CO_2$ 분석기의 제작 및 이를 이용한 SI 엔진에서의 실시간 배기가스 분석에 관한 연구)

  • Song, Hyun-Soo;Min, Kyoung-Doug
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3079-3084
    • /
    • 2008
  • A fast response $CO_2$ analyzer has been developed for measuring the $CO_2$ concentration during transient condition of SI engine. The analyzer is based on the non-dispersive infrared absorption technique, electrical chopping system and water cooling system. The analyzer has good repeatability, linearity and permissible drift characteristic. Besides, it has 18ms with a response to measure the $CO_2$ concentration. The fast response $CO_2$ analyzer was applied to single cylinder SI engine and the $CO_2$ emission was examined during engine start. Simultaneously, the standard exhaust gas analyzer, which has slow response time, was used for considering the engine-out $CO_2$ characteristic. The developed analyzer showed much faster responsive characteristic than that of a standard analyzer and made cycle by cycle exhaust gas analysis possible. The transient engine operating characteristics will be estimated and the transient behaviors on engine-out emission and performance will be improved.

  • PDF

Development of a Fast-Response $CO_2$ Analyzer using NDIR Technique and Its Application to SI Engine (비분산 적외선 흡수법을 이용한 고속응답 $CO_2$ 분석기의 제작 및 엔진 적용에 관한 연구)

  • Lee, Jae-Young;Min, Kyoung-Doug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.102-107
    • /
    • 2007
  • A fast response $CO_2$ ($fCO_2$) analyzer for real-time measurement of carbon dioxide concentration during transient states of internal combustion engines has been developed. This analyzer uses non-dispersive infrared absorption (NDIR) technique for measuring $CO_2$ concentration and Kalman filter for removing noise components from output signals. The analyzer has good linearity, repeatability and drift with a response time of 11 ms; it is sufficiently fast to detect $CO_2$ concentration during transient states of internal combustion engines. The $fCO_2$ analyzer was used to measure transient $CO_2$ concentration of exhaust gas of the SI engine with a standard gas analyzer, and the signal of the $fCO_2$ analyzer was compared to that of the standard gas analyzer. The two concentrations were well matched during the steady state, and the $fCO_2$ analyzer could measure the variations of $CO_2$ concentration during the transient state.

Photosynthetic Characteristics of Panax ginseng C.A. Meyer I. Photosynthetic Response to Changes of Light Intensity and Leaf Temperature (고려인삼의 광합성 특성 I. 광도와 잎온도의 변화에 따른 광합성 반응)

  • 현동윤;황종규
    • Journal of Ginseng Research
    • /
    • v.17 no.3
    • /
    • pp.240-245
    • /
    • 1993
  • This study was conducted with ginseng plants to investigate photosynthetic response to changes of light intensity and leaf temperature. $CO_2$ uptake in diurnal course was highest in the first phase (8 00~5 : 30 Am.) on May 30, 1992. In $CO_2$ uptake related to stomatal conductance, these relationship was synchronized in diurnal course, but relationship between TEX>$CO_2$ uptake and intercellular $CO_2$ concentration in diurnal course was synchronized oppositely. Leaf temperature and light intensity at the highest $CO_2$ uptake were in the range of 23~$24^{\circ}C$) and 95$\mu$mol.$m^{-2}$.$s^{-1}$), $CO_2$ , respectively. In response to an increasing light intensity under a constant leaf temperature ($18^{\circ}C$), $CO_2$ uptake was increased throughout the light intensity sequence up to 250$\mu$mol.$m^{-2}$.$s^{-1}$), $CO_2$ When $CO_2$ uptake was measured with a series of leaf temperature under a constant light intensity (250 $\mu$mol.$m^{-2}$.$s^{-1}$), $CO_2$ uptake was highest at $18^{\circ}C$ as a 4.1$\mu$mol.$m^{-2}$.$s^{-1}$), $CO_2$ . Similar changes were also observed in stomatal conductance and intercellular $CO_2$ concentration. Evidences from several approaches indicate that synchronization of $CO_2$ uptake, stomatal conductance and intercellular $CO_2$ concentration were closely inter-related and changes of leaf temperature iuluenced the photo-response in photosynthetic processes.

  • PDF

The Electrophysiology Application on Guard Cells to See the Influence of Carbon Dioxide

  • Lee, Joon-Sang
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.763-770
    • /
    • 2014
  • The effect of $CO_2$ on the opening of stomata in the intact leaf of Commelina communis has been investigated. Full opening of stomatal apertures(around $18{\mu}m$) was achieved in the intact leaf by addition of $CO_2$($900{\mu}mol\;mol^{-1}$). At 90 minutes, the stomatal apertures of leaves treated with $CO_2$ free air were reduced. In contrast, stomata opened most widely with the treatment of $CO_2$ air at 90 minutes. The effects of light, $CO_2$ air and $CO_2$ free air on the change of membrane potential difference(PD) were measured. Fast hyperpolarization of guard cell membrane PD was recorded reaching up to -12 mV in response to light. If $CO_2$ free air was given firstly, there was no response. When light was given after $CO_2$ free air, the light effect was very clear. At the onset of $CO_2$ air, the PD showed a dramatic hyperpolarization to about -25 mV. Changes in the pH of apoplast in intact leaves in response to $CO_2$ air were observed. $CO_2$ air caused a change of 0.4 pH unit. Therefore, it can be hypothesized that $CO_2$ flowing could stimulate proton efflux which is a necessary precursor of stomatal opening.

Effect of Working Temperature on Sensitivity of Au/SnO2 Core-Shell Structure Nanoparticles for CO Gas (Au/SnO2 core-shell 나노구조 센서의 구동온도가 CO 감동에 미치는 영향)

  • Yu, Yeon-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.456-460
    • /
    • 2012
  • Au/$SnO_2$ core-shell structure nanoparticles (NPs) were synthesized by microwave hydrothermal method, and the effect of working temperature on sensitivity of Au/$SnO_2$ core-shell NPs for CO gas was investigated. The $SnO_2$ shell layer was consisted of $SnO_2$ primary particles with 4.5 nm diameter. The response of Au/$SnO_2$ core-shell NPs for CO gas was maximized at the working temperature of $350^{\circ}C$ while the sensitivity increased with decreasing the working temperature due to the low grain size effect of $SnO_2$ NPs on the response of CO gas.

The Interaction of CO to the Co(salen) Complex in to PEDOT:PSS Film and Sensor Application

  • Memarzadeh, Raheleh;Panahi, Farhad;Javadpour, Sirus;Ali, Khalafi-Nezhad;Noh, Hui-Bog;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.1297-1302
    • /
    • 2012
  • The interaction between carbon monoxide (CO) and a cobalt-salen complex (Co(salen)) was studied and applied to detect CO. The metal complex doped PEDOT:PSS film exhibited good sensitivity to CO and differentiate CO from other gases. The response of the composite to CO was reversible (RSD < 5%) change in resistance upon removal of CO gas from the test chamber. The effects of adding Co(salen) in the probe film on the response of the sensor were investigated using AFM, XPS, and FT-IR spectroscopy. The sensitivity of the sensor increased as the Co(salen) concentration enhanced as it increased from 0.0 to 1.5 wt. %, where the highest sensitivity ($%{\Delta}R/R_o$) of $-25.0{\pm}0.05%$ was achieved with 1.0 wt. % Co(salen). The sensor containing probe exhibited a linear response ($R^2$ = 0.983) in the range of 0.5 to 10.0% CO (v/v) $N_2$, and the detection limit was 1.74% CO (v/v) in $N_2$.

Implementation and Analysis of CoAP-Based Lightweight OpenADR2.0b protocol for Smart Energy IoT Environment (스마트 에너지 IoT를 위한 CoAP 기반 Lightweight OpenADR2.0b 프로토콜의 구현 및 분석)

  • Park, Heon-Il;Kim, Se-Young;Kang, Seong-Cheol;Park, Hyun-Jin;Kim, Il-Yeon;Choi, Jin-Seek
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.904-914
    • /
    • 2017
  • For efficient energy usage, the concept of demand response has been emerged and thereby Open Automated D emand Response(OpenADR) protocol is developed as a standard protocol to provide automated demand response. There have been emerging trends on the demand response services using the Internet of Things(IoT) for smart h ome energy management. In this smart home energy IoT environment, a lightweight protocol is needed rather tha n the existing HTTP/ XML based OpenADR protocol for demand response services since many small devices wi ll be interconnected. In this paper, we propose a lightweight OpenADR protocol based on CoAP protocol for pro viding demand response service in Smart Energy IoT environment, implement the proposed CoAP-based protocol, and analyzed the performance compared to existing HTTP/ XML-based OpenADR 2.0b protocol.

The effect of coenzyme Q10 on endothelial function in a young population

  • Petrofsky, Jerrold;Laymon, M.;Lee, H.;Hernandez, E.;Dequine, D.;Thorsen, L.;Lovell, R.;Andrade, J.
    • Physical Therapy Rehabilitation Science
    • /
    • v.1 no.1
    • /
    • pp.6-12
    • /
    • 2012
  • Objective: Coenzyme (CoQ10) is an enzymatic co factor used in normal cellular metabolism. Recent evidence shows that in people with heart disease it can reverse endothelial cell damage in the blood vessels. It is also a potent antioxidant. Design: One group pretest-posttest design. Methods: In the present study, endothelial function was evaluated using the response to occlusion and heat before and 2 weeks after administration of CoQ10, 300 mg/day. Thirty Eight subjects, who are physical therapy students, participated in a series of experiments to see if taking 300 mg of CoQ10 daily for 2 weeks would impact resting blood flow in the forearm skin and the blood flow response to 4 minutes of vascular occlusion and the response to local heat ($42^{\circ}C$) for 6 minutes. Results: The results showed that, for this population, there was no difference in the response to heat. However, the response to occlusion was improved after administration of CoQ10. Conclusions: It would appear that in a young population CoQ10 has no effect on the nitric oxide vasodilator pathway in skin but does influence other vasodilator pathways.

  • PDF

Sustained SARS-CoV-2 antibody response in domestic pets: Insights from a longitudinal study

  • Yeonsu Oh;Dongseob Tark;Choi-Kyu Park;Ho-Seong Cho
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.4
    • /
    • pp.335-338
    • /
    • 2023
  • The COVID-19 pandemic, triggered by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has not only impacted human health on a global scale but also raised concerns about the vulnerability of a wide array of animals that are in close contact with humans. Particularly, the potential for infection and the subsequent immune response in domestic pets such as dogs and cats remain largely unexplored under natural living conditions. In this study, we have undertaken the task of detecting and tracking the presence of antibodies against SARS-CoV-2 in a small cohort of household pets-specifically, two dogs and two cats. Employing techniques such as the indirect ELISA and plaque reduction neutralization tests, we observed that the neutralizing antibodies against SARS-CoV-2 in these animals were maintained for a duration of up to six months following their initial positive test result. This duration mirrors the antibody response documented in human cases of COVID-19, suggesting a comparable post-infection immune response timeline between humans and these domestic animals.