• Title/Summary/Keyword: $CO_2$ measurement

Search Result 1,583, Processing Time 0.027 seconds

Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy (가임기 여성의 유방암 토모치료 시 난소선량 평가비교)

  • Lee, Soo Hyeung;Park, Soo Yeun;Choi, Ji Min;Park, Ju Young;Kim, Jong Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.337-343
    • /
    • 2014
  • Purpose : The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. Materials and Methods : The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Results : Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of $64.94{\pm}0.84mGy$ and $37.64{\pm}1.20mGy$ in left ovary part and average of $64.38{\pm}1.85mGy$ and $32.96{\pm}1.11mGy$ in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Conclusion : Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required.

On the Study of Forest Sampling Methods in Natural Deciduous Forest (활엽수림(闊葉樹林)에 대(對)한 자원조사법(資源調査法)의 연구(硏究))

  • Kim, Kap Duk
    • Journal of Korean Society of Forest Science
    • /
    • v.17 no.1
    • /
    • pp.35-42
    • /
    • 1973
  • Deciduous trees grown naturally in the forest of Korea usually have an irregular Lee-form and their utility has been decreased. In Korea, most of the deciduous stands are distributed in the hinterland. A shortage of the total growing stock made utilization of them necessary in this country even though some difficulties to be cutted and transported are accompanied. Therefore, this study was conducted to select the suitable sampling method for surveying them. The results investigated are as follows. 1. Three locations being 10 hectares in each location for the plots were chosen and surveyed with six $20m{\times}50m$ rectangular sample plots by four types of sampling method below. And the result is shown in Table 1. A. Random sampling by grids B. Random sampling by co-ordinates C. Systematic line plot. D. Sub-sampling 2. One hundred and fifty hectares from all plots were sectioned through the application of aerial photography scaled of 1 : 15,000. The author divided forest types according to diameter class and crown density with mirror stereoscope. The forest types were divided into three classes. Seven sample plots from the area of 150 hectars are systematically arranged and the results investigated on the circular sample point of 0.1 hectare are shown in Table 4. 3. There were no significant differences between results by sampling method and by diameter measurement method (population mean) as shown in Table 3. 4. Random sampling by grid and systematic line plot are better than others. 5. There are more over-estimated values when the circular sample point is used than where the rectangular sample point. 6. As forest stands are irregular, smaller number of sample points will make many errors.

  • PDF

Evaluation of Physical Properties of Nanoemulsion Ampoule as Customized Cosmetic Bases and Evaluation of Satisfaction According to Skin Type (맞춤형화장품 베이스로서 나노에멀젼 앰플의 물성 평가 및 피부타입에 따른 만족도 평가)

  • Se-Yeon, Kim;Hyung Guen, An;Ja Young, Kim;Kyung-Sup, Yoon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.4
    • /
    • pp.343-355
    • /
    • 2022
  • Customized cosmetics are continuously mentioned as cosmetics in response to changes in the social environment and trends that emphasize individuality. Therefore, in this study, four types of nanoemulsion ampoules corresponding to skin types were prepared by different ratios of nanoemulsion formulation and ampoule formulation, and the applicability as a customized cosmetic base was checked. Particle size, polydispersity index, zeta potential, and viscosity according to time for 90 d were measured for four nanoemulsion ampoules with different volatile residues, and turbiscan was measured as a method for evaluating the stability of a colloidal dispersion system. Finally, human usability satisfaction was evaluated. As a result, it was confirmed that four kinds of nanoemulsion ampoules had a higher amount of volatile residue in the dry skin test product than in the oily skin test product. The pH was in the range of 6.41 to 6.88, and the particle size was in the range of 170 to 174 nm, and the change after 90 d was within 1.2% of the maximum, and there was no specificity in particle size stability. It was confirmed that the polydispersity index was almost constant, and showed a particle size distribution close to monodispersity by showing a change within a value smaller than 0.21 in all test products. The zeta potential was initially -63 mV or more for all four types of test products, and although it showed a slight decrease with time, there was little change to the extent of a maximum decrease of 2.5%. Viscosity was initially in the range of 4,100 to 5,100 cps and showed a decreasing trend with time, showing a maximum decrease of 37.7%. In the turbiscan measurement, the turbiscan stability index, a measure of stability, was all below 1.0, indicating dispersion stability. In the usability satisfaction evaluation (6 points) of 4 nanoemulsion ampoules corresponding to skin type, oily skin product (5.42 ± 0.67 points) > neutral oily skin product (5.36 ± 0.67 points) > neutral dry skin product (5.15 ± 0.69 point) > dry skin product (4.75 ± 0.75 points) in the order of evaluation. Four types of nanoemulsion ampoules are physically stable and have confirmed their applicability as a customized cosmetic base according to skin type, and are expected to expand in various ways.

Factors Affecting Wet-Paddy Threshing Performance (탈곡기의 제작동요인이 벼의생탈곡성능에 미치는 영향)

  • 남상일;정창주;류관희
    • Journal of Biosystems Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-14
    • /
    • 1980
  • Threshing operation may be one of the most important processes in the paddy post-production system as far as the grain loss and labor requirement are concerned . head-feeding type threshers commercially available now in Korea originally were developed for threshing dry paddy in the range of 15 to 17 % in wet basis. However, threshing wet-paddy with the grain moisture content above 20 % has been strongly recommended, especially for new high-yielding Indica -type varieties ; (1) to reduce high grain loss incurred due to the handling operations, and (2) to prevent the quantitative and qualitative loss of milled -rice when unthreshed grains are rewetted due to the rainfall. The objective of this study were to investigate the adaptability of both a head-feeding type thresher and a throw-in type thresher to wet-paddy , and to find out the possiblilities of improving the components of these threshers threshing. Four varieties, Suweon 264 and Milyang 24 as Tongil sister line varieties, minehikari and Jinhueng as Japonica-type varieties, were used at the different levels of the moisture content of grains. Both the feed rate and the cylinder speed were varied for each material and each machine. The thresher output quality , composition of tailing return, and separating loss were analyzed from the sampels taken at each treatment. A separate experiment for measurement opf the power requirement of the head-feeding type thresher was also performed. The results are summarized as follows : 1. There was a difference in the thresher output quality between rice varieties. In case of wet-paddy threshing at 550 rpm , grains with branchlet and torn heads for the Suweon 264 were 12 % and 7 % of the total output in weight, respectively, and for the Minehikari 4.5 % and 2 % respectively. In case of dry paddy threshing , those for the Suweon 264 were 8 % and 5% , and for the Minehikari 4% and 1% respectively. However, those for the Milyang 23 , which is highly susceptable to shattering, were much lower with 1 % and 0.5% respectively, regardless of the moisture content of the paddy. Therefore, it is desirable to breed rice varieties of the same physical properties as well as to improve a thresher adaptable to all the varieties. Torn heads, which increased with the moisture content of rall the varieties except the Milyang 23 , decreased as the cylinder speed increased, but grains with branchlet didnt decrease. The damaged kernels increased with the cylinder speed. 3. The thresher output quality was not affected much by the feed rate. But grains with branchlet and torn heads increased slightly with the feed rate for the head-feeding type thresher since higher resistance lowered at the cylinder speed. 4. In order to reduce grains with branchlet and torn heads in wet-paddy threshing , it is desirable to improve the head-feeding type thresher by developing a new type of cylinder which to not give excess impact on kernels or a concave which has differenct sizes of holes at different locations along the cylinder. 5. For the head-feeding type thresher, there was a difference in separating loss between the varieties. At the cylinder speed of 600 rpm the separating losses for the Minehikari and the Suweon 264 were 1.2% and 0.6% respectively. The separating loss of the head-feeding type thresher was not affected by the moisture content of paddy while that of the Mini-aged thresher increased with the moisture content. 6. From the analysis of the tailings return , to appeared that the tailings return mechanism didn't function properly because lots of single grains and rubbishes were unnecessarily returned. 7. Adding a vibrating sieve to the head-feeding type thresher could increase the efficiency of separation. Consequently , the tailing return mechanism would function properly since unnecessary return could be educed greatly. 8. The power required for the head-feeding type thresher was not affected by the moisture content of paddy, but the average power increased linearly with the feed rate. The power also increased with the cylinder speed.

  • PDF

Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan (전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석)

  • 사정호;서태석;최보영;정규회
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.59-71
    • /
    • 2000
  • It is possible to obtain a fast CT scan during breath holding with spiral technique. But the risk of radiation is increased due to detailed and repeated scans. However, the limitation of X-ray doses is not fully specified on CT, yet. Therefore, the purpose of the present study is to define the limitation of X-ray doses on CT The CT unit was somatom plus 4. Alderson Rando phantom, Solenoid water phantom, TLD, and reader were used. For determining adequate position and size of organs, the measurement of distance(${\pm}$2mm) from the midline of vertebral body was performed in 40 women(20~40 years). On the brain scan for 8:8(8mm slice thickness, 8mm/sec movement velocity of the table) and 10:10(10mm slice thickness, 10mm/sec movement velocity of the table) methods, the absorption doses of exposed area of the 10:10 were slightly higher than those of 8:8. The doses of unexposed uterus were negligible on the brain scan for both 8:8 and 10:10. On the chest scan for 8:8, 8:10(8mm slice thickness, 10mm/sec movement velocity of the table), 10:10, 10:12(10mm slice thickness, 12mm/sec movement velocity of the table) and 10:15(10mm slice thickness, 15mm/sec movement velocity of the table) methods, 8:8 method of the absorption doses of exposure area was the most highest and 10:15 method was the most lowest. The absorption doses of 8:10 method was relatively lower than those of the other methods. In conclusion, the 8:10 method is the most suitable to give a low radiation burden to patient without distorting image quality.

  • PDF

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Effect of Noise in Human Body (소음이 인체에 미치는 영향)

  • 이영노
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.7-8
    • /
    • 1972
  • The effects of noise exposure are of two types: Nonauditory effects and auditory effects. Nonauditory effects of noise exposure are interference with communication by speech, sleeping and emotional behavior. The noise will cause the high blood pressure and rapid pulse, also that decrease the salivation and gastric juice. in experimentaly showed that the Corticoid hormon: Gonatotropic hormone were decrease and Thyrotropic hormoone is increase. Auditory effect of noise exposure. when the normal ear is exposed to noise at noise at hamful intensities (above 90㏈) for sufficiently long periods of time, a temoral depression of hearing results, disappearing after minutes or hours of rest. When the exposure longer or intesity greater is reached the Permanent threshold shift called noise-induced hearing loss. Hearing loss resulting from noise exposure presents legal as well as medical problems. The otologist who examines and evaluates the industrial hearing loss cases must be properly informed, not only concerning the otologic but also about the physical and legal aspects of the problems. The measurement of hearing ability is the most important part of a hearing conservation, both preplacement and periodic follow-up tests of hearing. The ideal hearing conservation program would be able to reduce or eliminate the hazardous noise at its source or by acoustic isolation of noisy working area and two ear protections (plugs and muff type) were developed for personal protection.

  • PDF

How Skin Care Ingredient Concentrations Can Modulate the Effect of polyols and Oils on Skin Moisturization and Skin Surface Roughness (화장품 원료 중 폴리올, 오일 농도에 따른 피부 보습과 피부 표면 거칠기의 변화)

  • Nam, Gae-Won;Kim, Seung-Hun;Kim, Eun-Joo;Kim, Jin-Han;Chae, Byung-Guen;Lee, Hae-Kwang;Moon, Seong-Joon;Kang, Hak-Hee;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.4 s.54
    • /
    • pp.337-342
    • /
    • 2005
  • The aim of this study was to evaluate the influence of different skin care ingredient concentrations on the effect of polyols and oils on the human skin moisturization and skin surface roughness. Polyols and oils were essential ingredients to make a skin care formulation. But these were still not understood how much concentration(s) were tested on human skin in the aspect of efficacy and sensory. We studied to examine various concentrations of ingredient by cosmetic companies using noninvasive methods. Polyols were composed of glycerol and butylene glycol (BG) as 1:1 ratio, and oils were hydrogenated polydecene, cetyl ethylhexanoate and pentaerythrityl tetraethylhexanoate (PTO(R), Stearinerie Dubois Fils Co., France) as 1:1:1 ratio. All compounds were tested $0{\sim}27%dml$ Polyols and $0{\sim}35%dml$ oils in O/W emulsions. We investigated the effect of water contents and the effect of stratum corneum roughness in forearm skin after application of compounds. Water contents of the skin measured by skin capacitance and skin surface roughness measured visual scoring of skin surface biopsy through the scanning electron microscopy. Water contents of the skin were highly related to amount of polyols (to 20%) and oils (to 12%). Correlation coefficients were 0.971 and 0.985 respectively (p<0.01), 2 h after application. Skin surface roughness was positively correlated with polyol contents in concentration dependent manner, and depend on oils up to 6%. The ratio of coefficient was 2.5 to 1 (polyol to oils) by regression analysis. Further studies will be conducted with other ingredients such as surfactants, lipids and aqueous materials, and with ether methods for noninvasive measurement.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

CRANIOFACIAL STRUCTURE AND ARCH DIMENSION OF ADULT CLASS III MALOCCLUSION (성인 III급 부정교합자의 악안면골격구조 및 치열궁형태에 관한 연구)

  • Lee, Dong-Geun;Suhr, Cheong
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.359-372
    • /
    • 1997
  • This study was conducted to discern differences of craniofacial, dentoalveolar structure and model measurements between sex and between class n openbite group and non-openbite group. The sample consisted of 49 adult patients with class Il malocclusion. 24 linear measurements, 22 angular measurements and 12 ratios were selected in lateral cephalometry. Also, arch width, length, anterior crowding, average molar relation were measured or calculated in diagnostic model. The data were evaluated by t-test and multiple discriminant analysis. The results were as follows, 1. Most linear measurements, with the exception of MnBL and AUDH, were significantly larger in male(p<0.05). but, intermaxillary relations and spatial position of maxilla and mandible relative to cranial base were not different for both sex. 2. With the exception of upper and lower anterior crowding, lower arch width, upper arch length, AMR, male exhibited significantly larger measurements in model analysis (p<0.05). 3. Size differences of maxilla and mandible between openbite and non-openbite group were not significant(p>0.05). but openbite group showed significantly increased genial angle(p<0.05), FH-CoGo(p<0.01), FH-NA(p<0.01) and FH-NB, FH-NPog (p<0.05). 4. ALFH and PUDH were larger(p<0.05) in openbite group. this result served as compensation for the spatial position of mandible relative to cranial base. AUPUDH (p<0.001) and ALPLDH(p<0.05) were lower in openbite group. upper anterior crowding was the only measurement which showed difference between openbite and non-openbite group(p<0.05). 5. For the purpose of classifying adult class n openbite and non-openbite group, multiple discriminant analysis was done genial angle, ALPLDH, AUPUDH, FH-NA were included in multiple discriminant equation. 39 cases($92.86\%$) were correctly classified when applied to the sample used in this study.

  • PDF