• Title/Summary/Keyword: $CO_2$ leakage

Search Result 381, Processing Time 0.029 seconds

Varistor Properties of Sn2O3- Doped ZnO-Pr6O11-CoO-Doped -Based Ceramics (Sn2O3가 첨가된 ZnO-Pr6O11-CoO계 세라믹스의 바리스터 특성)

  • 남춘우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.1
    • /
    • pp.39-45
    • /
    • 2003
  • The varistor properties of ZnO-Pr$_{6}$O$_{11}$-CoO-based ceramics doped with Sm$_2$O$_3$were investigated in the addition range of 0.0~2.0 mol% Sm$_2$O$_3$at sintering temperature of 130$0^{\circ}C$ and 135$0^{\circ}C$. As Sm$_2$O$_3$ content is increased, the breakdown voltage was increased in the range of 348.9~521.8 V/mm for ceramics sintered at 130$0^{\circ}C$ and 8.5~381.3 V/mm for ceramics sintered at 135$0^{\circ}C$. On the whole, the increase of sintering temperature led to the low nonlinearity regardless of Sm$_2$O$_3$content. ZnO-Pr$_{6}$O$_{11}$-CoO-based ceramics doped with 1.0 mol% at each sintering temperature exhibited the most superior varistor properties, with the nonlinear exponent of 42.1 at 130$0^{\circ}C$, 36.8 at 135$0^{\circ}C$ and the leakage current of 9.2 $\mu$A at 130$0^{\circ}C$, 11.7 $\mu$A at 135$0^{\circ}C$.EX>.EX>.

Parameters On-line Identification of Dual Three Phase Induction Motor by Voltage Vector Injection in Harmonic Subspace

  • Sheng, Shuang;Lu, Haifeng;Qu, Wenlong;Guo, Ruijie;Yang, Jinlei
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.288-294
    • /
    • 2013
  • This paper introduces a novel method of on-line identifying the stator resistance and leakage inductance of dual three phase induction motor (DTPIM). According to the machine mathematical model, the stator resistance and leakage inductance can be estimated using the voltage and current values in harmonic subspace. Thus a method of voltage vector injection in harmonic subspace (VVIHS) is proposed, which causes currents in harmonic space. Then the errors between command and actual harmonic currents are utilized to regulate the machine parameters, including stator resistance and leakage inductance. The principle is presented and analyzed in detail. Experimental results prove the feasibility and validity of proposed method.

Case Study on Stability Assessment of Pre-existing Fault at CO2 Geologic Storage (CO2 지중저장 시 단층 안정성 평가)

  • Kim, Hyunwoo;Cheon, Dae-Sung;Choi, Byung-Hee;Choi, Hun-Soo;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.23 no.1
    • /
    • pp.13-30
    • /
    • 2013
  • Increase of pore fluid pressure resulting from injection of $CO_2$ may reactivate pre-existing faults, and the induced seismic activities can raise the safety issues such as seal integrity, restoration of storage capacity, and, in the worst case, removal of previously injected $CO_2$. Thus, fault stability and potential for $CO_2$ leakage need to be assessed at the stage of site selection and planning of injection pressure, based on the results of large-scale site investigations and numerical modeling for various scenarios. In this report, studies on the assessment of fault stability during injection of $CO_2$ were reviewed. The seismic activities associated with an artificial injection of fluids or a release of naturally trapped high-pressure fluids were first examined, and then site investigation methods for the magnitude and orientation of in situ stresses, the distribution and change of pore fluid pressure, and the location of faults were generally summarized. Recent research cases on possibility estimation of fault reactivation, prediction of seismic magnitude, and modeling of $CO_2$ leakage through a reactivated fault were presented.

Spatio-Temporal Monitoring of Soil CO2 Fluxes and Concentrations after Artificial CO2 Release (인위적 CO2 누출에 따른 토양 CO2 플럭스와 농도의 시공간적 모니터링)

  • Kim, Hyun-Jun;Han, Seung Hyun;Kim, Seongjun;Yun, Hyeon Min;Jun, Seong-Chun;Son, Yowhan
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.2
    • /
    • pp.93-104
    • /
    • 2017
  • CCS (Carbon Capture and Storage) is a technical process to capture $CO_2$ from industrial and energy-based sources, to transfer and sequestrate impressed $CO_2$ in geological formations, oceans, or mineral carbonates. However, potential $CO_2$ leakage exists and causes environmental problems. Thus, this study was conducted to analyze the spatial and temporal variations of $CO_2$ fluxes and concentrations after artificial $CO_2$ release. The Environmental Impact Evaluation Test Facility (EIT) was built in Eumseong, Korea in 2015. Approximately 34kg $CO_2$ /day/zone were injected at Zones 2, 3, and 4 among the total of 5 zones from October 26 to 30, 2015. $CO_2$ fluxes were measured every 30 minutes at the surface at 0m, 1.5m, 2.5m, and 10m from the $CO_2$ releasing well using LI-8100A until November 13, 2015, and $CO_2$ concentrations were measured once a day at 15cm, 30cm, and 60cm depths at every 0m, 1.5m, 2.5m, 5m, and 10m from the well using GA5000 until November 28, 2015. $CO_2$ flux at 0m from the well started increasing on the fifth day after $CO_2$ release started, and continued to increase until November 13 even though the artificial $CO_2$ release stopped. $CO_2$ fluxes measured at 2.5m, 5.0m, and 10m from the well were not significantly different with each other. On the other hand, soil $CO_2$ concentration was shown as 38.4% at 60cm depth at 0m from the well in Zone 3 on the next day after $CO_2$ release started. Soil $CO_2$ was horizontally spreaded overtime, and detected up to 5m away from the well in all zones until $CO_2$ release stopped. Also, soil $CO_2$ concentrations at 30cm and 60cm depths at 0m from the well were measured similarly as $50.6{\pm}25.4%$ and $55.3{\pm}25.6%$, respectively, followed by 30cm depth ($31.3{\pm}17.2%$) which was significantly lower than those measured at the other depths on the final day of $CO_2$ release period. Soil $CO_2$ concentrations at all depths in all zones were gradually decreased for about 1 month after $CO_2$ release stopped, but still higher than those of the first day after $CO_2$ release stared. In conclusion, the closer the distance from the well and the deeper the depth, the higher $CO_2$ fluxes and concentrations occurred. Also, long-term monitoring should be required because the leaked $CO_2$ gas can remains in the soil for a long time even if the leakage stopped.

A Study on the Output Characteristics of theraphy $CO_2$laser AC Converter $CO_2$ Laser System using 3 Electrode-type and Ring Blower (교류콘버터 기반에서 3전극 방식의 Theraphy $CO_2$ Laser 가변출력특성의 연구)

  • 김휘영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.257-260
    • /
    • 2002
  • In this paper, the circuit of AC Choppers for $CO_2$laser Power Supply are proposed and investigated. IGBT-controlled ac voltage regulators, operating at high frequency chopping mode. Chopping-to-supply duty ratio plays an important role in terms of laser output. Laser input energy is varied by controlling the leakage transfomer used with the proposed system. This improved circuit employs a 3 electrode-type and Ring Blower. This improved circuit system has many advantages compared with the conventional SMPS such as simple design requirment, easy implementation, high reliability, low switching loss, and consequently high efficiency. As a result, the maximun output was 16W at duty-ratio of 92%, total gas mixture of $CO_2$: $N_2$: He = 1 : 9 : 15, total pressure of 15torr.

  • PDF

Effect of Sintering lime on Electrical Stability against Surge Stress of Zn-Pr-Co-Cr-Y Oxide-based Varistors (Zn-Pr-Co-Cr-Y 산화물계 바리스터의 써지 스트레스에 대한 전기적 안정성에 소결시간의 영향)

  • Nahm, Choon-Woo;Park, Jong-Ah;Yoo, Dea-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.7
    • /
    • pp.615-621
    • /
    • 2005
  • The electrical stability against surge stress of varistors, which are composed of Zn-Pr-Co-Cr-Y oxide system, were investigated at different sintering times. As sintering time increases, the varistor voltage and nonlinear exponent decreased in the range of $279.6\~179.1$ and $52.5\~24.9$, respectively. On the contrary, the leakage current and dielectric dissipation factor increased in the range of $1.2\~9.8\;{\mu}A$ and 0.0461\~0.0651 with increase of sintering time. For all varistors, the variation rates of V-I characteristic parameters against surge stress were more strongly affected in order of varistor voltage ${\rightarrow}nonlnear$ $exponent{\rightarrow}leakage$ current. On the whole, the electrical stability against surge stress increased with increasing sintering time. Conclusively, it is assumed that the varistors sintered for 2 h exhibited comparatively good characteristics, in view of overall characteristics.

Electrical and Dielectric Characteristics of Zn-Pr-Co-Er-M(M=Ni, Mg, Cr) Oxides-Based Varistors (Zn-Pr-Co-Er-M(M=Ni, Mg, Cr)산화물계 바리스터의 전기적, 유전적 특성)

  • 남춘우;김명준
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.8
    • /
    • pp.605-609
    • /
    • 2004
  • The microstructure, electrical and dielectric characteristics of ZnO varistors were investigated at various metal oxide (NiO, MgO, and Cr$_2$O$_3$) additives. The average grain size was increased with addition of NiO while that was decreased with addition of Cr$_2$O$_3$-Thereby, the varistor voltage was higher in Cr$_2$O$_3$-added composition. Among varistors, the varistor added with Cr$_2$O$_3$ exhibited the highest nonlinearity, with 40.5 in the nonlinear exponent and 2.7 ${\mu}$A in the leakage current and its dielectric dissipation factor was relatively low value of 0.0589.

Effect of Information Security Incident on Outcome of Investment by Type of Investors: Case of Personal Information Leakage Incident (정보보안사고가 투자주체별 투자성과에 미치는 영향: 개인정보유출사고 중심으로)

  • Eom, Jae-Ha;Kim, Min-Jeong
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.2
    • /
    • pp.463-474
    • /
    • 2016
  • As IT environment has changed, paths of information security in financial environment which is based on IT have become more diverse and damage caused by information leakage has been more serious. Among security incidents, personal information leakage incident is liable to give the greatest damage. Personal information leakage incident is more serious than any other types of information leakage incidents in that it may lead to secondary damage. The purpose of this study is to find how much personal information leakage incident influences corporate value by analyzing 21 cases of personal information leakage incident for the last 15 years 1,899 listing firm through case research method and inferring investors' response of to personal information leakage incident surveying a change in transaction before and after personal information leakage incident. This study made a quantitative analysis of what influence personal information leakage incident has on outcome of investment by types of investors by classifying types of investors into foreign investors, private investors and institutional investors. This study is significant in that it helps improve awareness of importance of personal information security by providing data that personal information leakage incident can have a significant influence on outcome of investment as well as corporate value in Korea stock market.

Evaluation of Structural Integrity and Leakage for a Gas Turbine Casing (가스터빈 케이싱의 구조안전성 및 누설 평가)

  • Seo, Hee Won;Ham, Dong Woo;Kim, Kyung Kook;Han, Jeong Sam
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.4
    • /
    • pp.347-354
    • /
    • 2016
  • Because typical gas turbine systems have frequent startup and shutdown operations, it is likely to cause cracks at the gas turbine casing and gas leakages at casing flanges due to thermal fatigue and embrittlement. Therefore, the evaluation of structural integrity and gas leakage at the gas turbine casings must be performed. In this paper, we have evaluated the structural integrity of the turbine casing and bolts under a normal operation in accordance with ASME B&PVC and evaluated the leakage at casing flanges by examination of contact pressure calculated using the finite element analysis. Finally, we propose a design flow including finite element modeling, the interpretation and evaluation methods for gas turbine casings. This may be utilized in the design and development of gas turbine casings.

Tape-Type Liquid Leakage Film Sensor (액체누설 감지용 테이프형 필름센서)

  • Yu, D.K.;Kim, K.S.;Yub, H.K.;Han, G.H.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.146-154
    • /
    • 2011
  • The adhesive-tape of a liquid leak film sensor including the alarm system is developed. The sensing film is composed of three layers such as base film layer, conductive line layer, and protection film layer. The thickness of film is 300~500 um, the width is 3.55 cm, and the unit length is 200 m. On the conductive line layer, three conducting lines and one resistive line are formulated by the electronic printing method with a conducting ink of silver-nano size. When a liquid leaks for the electricity to be conducted between the conductive line and the resistive line, the position of leakage is monitored by measuring the voltage varied according to the change of resistance between two lines. The error range of sensing position of 200 m film sensor is ${\pm}1m$.