• Title/Summary/Keyword: $CO_2$ heat pump

Search Result 169, Processing Time 0.03 seconds

Evaporation pressure drop of $CO_2$ in a horizontal tube (수평관내 이산화탄소의 증발 압력강하)

  • Lee Dong-Geon;Son Chang-Hyo;Oh Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.552-559
    • /
    • 2005
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor qualify, heat flux and saturation temperature. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations. the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

Analysis of Heat Transfer Performance of a Gas Cooler of CO2 Heat Pump for Water Heating (온수제조용 CO2 히트펌프의 가스쿨러 열전달 성능 해석)

  • Kwon, Jeong-Tae;Lee, Chang-Kyung;Baek, Dong-Seok;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5317-5322
    • /
    • 2013
  • This study presents a prediction method for heat transfer performance of a gas cooler of $CO_2$ heat pump using ${\epsilon}$-NTU method, and compared the results with the experimental data from the open literature. The heat transfer rate, refrigerant side outlet temperature and water side outlet temperature were calculated by using EES(Engineering Equation Solver)program in multi-tube-in-tube type $CO_2$ heat pump gas cooler. Analysis was performed in two methods : The first method performed without dividing into the test section by applying an analysis of the mean properties(mean analysis). The second method, tube length divided into 50 sections, was applied to the local properties(local analysis). From the present study, a good agreement at the local analysis was obtained between the analytical and experimental results by 0.3~1.1%, 1.31~1.88% and 3.12~5.18% for heat transfer rate, water and refrigerant side outlet temperatures, respectively.

Study on the Fuzzy Control of CO2 Heat Pump System (이산화탄소 열펌프 시스템의 퍼지 제어에 관한 연구)

  • Lee, Jae-Seung;Han, Yung-Hee;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.513-518
    • /
    • 2008
  • In the air-conditioning and refrigeration industry, the efforts to protect the environment have been made. One of them is to use carbon dioxide as an alternative refrigerant, however, several researches have shown that the transcritical heat pump system using $CO_2$ has relatively lower efficiency resulting in a degraded steady-state system performance. Capacity control with fuzzy controller was carried out for $CO_2$ heat pump system. Evaporator secondary fluid outlet temperature was suggested for the control variable of compressor speed modulation.

  • PDF

Comparative Evaluation of the Cooling and Heating Performance of a $CO_2$ Heat Pump System for Vehicles (차량용 이산화탄소 열펌프 시스템의 냉난방 성능 비교평가)

  • Kim, Sung-Chul;Kim, Min-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.126-131
    • /
    • 2009
  • A $CO_2$ heat pump system was designed for both cooling and heating in the cabin of electric vehicles, hybrid vehicles or fuel cell vehicles, In this study, the performance characteristics of the heat pump system without any supplementary heating device were analyzed and the heating performance was compared with the cooling performance for various operating conditions. Experiments were carried out by changing the speed of electric drive compressor, the air flow rate of interior heat exchanger and the air inlet temperature and speed of exterior heat exchanger. Therefore, the cooling/heating capacities and the corresponding COPs are quantified. Also, the heat pump system showed an improved performance for the cooling operation and the heating operation. In this study, the experimental results can be used to evaluate the effect of system design changes on system performance as well as the development of a highly efficient heat pump system.

Cooling and Heating Performances of a CO2 Heat Pump with the Variations of Operating Conditions (운전조건 변화에 따른 이산화탄소 열펌프의 냉난방 성능특성 비교)

  • Cho, Hong-Hyun;Baek, Chang-Hyun;Lee, Eung-Chan;Kang, Hun;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.6
    • /
    • pp.454-462
    • /
    • 2008
  • Since operating conditions are significantly different for heating and cooling mode operations in a $CO_2$ heat pump system, it is difficult to optimize the performance of the $CO_2$ cycle. In addition, the performance of a $CO_2$ heat pump is very sensitive to outdoor temperature and gascooler pressure. In this study, the cooling and heating performances of a variable speed $CO_2$ heat pump with a twin-rotary compressor were measured and analyzed with the variations of EEV opening and compressor frequency. As a result, the cooling and heating COPs were 2.3 and 3.0, respectively, when the EEV opening was 22%. When the optimal EEV openings for heating and cooling were 28% and 16%, the cooling and heating COPs increased by 3.3% and 3.9%, respectively, over the COPs at the EEV opening of 22%. Beside, the heating performance was more sensitive to EEV opening than the cooling performance. As the compressor speed decreased by 5 Hz, the cooling COP increased by 2%, while the heating COP decreased by 8%.

Prediction of Adiabatic Capillary Tube Length of Heat Pump Using Carbon Dioxide (CO2 히트펌프용 단열 모세관 길이 예측에 관한 연구)

  • Oh, Hoo-Kyu;Choi, Kwang-Hwan;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.576-581
    • /
    • 2011
  • In this paper, the prediction of adiabatic capillary tube of heat pump using carbon dioxide is investigated theoretically and experimentally to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include evaporation temperature, cooling pressure of gas cooler, mass flowrate, and the length and diameter of capillary tube. Based on study results of several researchers, the correlation predicting the length of capillary tube of $CO_2$ heat pump was proposed. And the experimental results of evaporation temperature, mass flowrate and cooling pressure in adiabatic capillary tube have an good agreement to those calculated from Eq. (3) within 0.63~10.9%. Therefore, the prediction calculating the length of adiabatic capillary tube of $CO_2$ heat pump was proposed at the given conditions such as cooling pressure, evaporation temperature and capillary tube diameter.

Study on Heat Transfer and Pressure Drop Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Cooling Condition ($CO_2$ 열펌프용 내부 열교환기의 냉방조건에서 열전달 및 압력 강하 특성에 대한 연구)

  • Kim, Dae-Hoon;Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.517-525
    • /
    • 2008
  • In order to study the heat transfer and pressure drop of an internal heat exchanger for $CO_2$ heat pump under cooling condition, the experiment and numerical analysis were performed. Four kinds of internal heat exchangers with a coaxial tube type and a micro-channel tube type were used. The experimental apparatus consisted of a test section, a power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. The section-by-section method and Hardy-Cross method were used for the numerical analysis. The effects of the internal heat exchanger refrigerant flow rate, the length of the internal heat exchanger, the operating condition of the gas-cooler, the evaporator and the type of the internal heat exchangers were investigated. With increasing of the flow rate, the heat transfer rate increased about 25%. The heat transfer rate of the micro-channel tube type was higher about 100% than that of the coaxial tube type. With increasing of the length of the internal heat exchanger, the heat transfer rate increased about $20{\sim}50%$. The pressure drop of the low-side tube was larger compared with that of the high-side tube.

Operating Characteristics of Internal Heat Exchanger for $CO_2$ Geothermal Heat Pump in the Heating Mode (난방모드 시 $CO_2$ 지열히트펌프의 내부열교환기에 대한 운전특성)

  • Kim, Jae-Duck;Lee, Sang-Jae;Kim, Seon-Chang;Kim, Young-Lyoul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1226-1231
    • /
    • 2009
  • This paper presents operating characteristics of internal heat exchanger(IHX) for $CO_2$ geothermal heat pump in the heating mode. Mass flow rate of $CO_2$, inlet temperatures of $CO_2$ at high and low pressure side were selected as main effect factors by using fractional factorial DOE(Design of Experiments). And RSM(Response Surface Method) was used in optimization phase. The results show that heat transfer rate of IHX increases when either inlet temperature of low pressure side decreases or inlet temperature of high pressure side increases. Effectiveness of IHX increases with increasing of inlet temperature of either high pressure side or low pressure side. Finally, performance contour map was provided over the operation ranges of the main design factors.

  • PDF

Renewable Energy Production by Heat Pump as Renewable Energy Equipment (신재생에너지 기기로서 히트펌프의 신재생에너지 생산량)

  • Hong, Hiki;Choi, Junyoung;Im, Shin Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.10
    • /
    • pp.551-557
    • /
    • 2017
  • Most European economies, Japan, and many governments have made it a major policy to expand the green business by disseminating heat pump technology, which has a large $CO_2$ reduction effect. The heat pump of all heat sources has been recognized as renewable energy and the policy to encourage has been implemented. In the recently revised Renewable Energy Law, the hydrothermal source (surface sea water) heat pump was newly included in renewable energy. In addition, the scope of application of heat pumps has expanded in the mandatory installation of renewable energy for new buildings, remodeling buildings, and reconstructed buildings based on this law. However application to heat pumps using all natural energy as heat source has been put off. In this revision, the ratio of renewable energy to the total energy produced by the heat pump was fixed at 73%, which depends on coefficient of performance of heat pump. The ratio of renewable energy is $1-1.8/COP_H$, and should be calculated including the coefficient of performance of the heat pump. Using a high efficiency heat pump or a high-temperature heat source increases the coefficient of performance and also reduces $CO_2$ emissions. It is necessary to expand the application of heat pumps as renewable energy equipment and to improve the correct calculation of renewable energy production.

Experimental Study on the Performance of a CO2 Heat Pump Water Heater under Various Operating Conditions (이산화탄소 급탕 열펌프의 운전조건에 따른 성능 특성에 관한 실험적 연구)

  • Sohn, Dong-Jin;Baek, Chang-Hyun;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.273-280
    • /
    • 2011
  • In this study, the steady state performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, compressor frequency, EEV opening, and water mass flow rate. Transient state performance tests were also conducted to investigate major system effects associated with the interaction between the $CO_2$ heat pump water heater and the water tank. Optimum refrigerant charge amount for the system was 1600 g. At compressor frequencies of 50 Hz and 60 Hz, water mass flow rates of 95 kg/h and 105 kg/h, and EEV opening of 8% and 16%, the water heating temperatures were $65^{\circ}C$ and $68^{\circ}C$ and COPs were 3.0 and 2.8, respectively. In the transient condition, the instantaneous COP decreased with an increase in the inlet water temperature.