• Title/Summary/Keyword: $CO_2$ emission coefficient

Search Result 60, Processing Time 0.027 seconds

Environmental Damage Theory Applicable to Kenya

  • ONYANGO, James;KIANO, Elvis;SAINA, Ernest
    • Asian Journal of Business Environment
    • /
    • v.11 no.1
    • /
    • pp.39-50
    • /
    • 2021
  • Purpose: This study seeks to establish the environmental damage theory applicable to Kenya. The analysis is based on annual data drawn from World Bank on carbon dioxide emissions (CO2e) and gross domestic product per capita (GDPPC) for Kenya spanning 1963 to 2017. Research Methodology: The study adopts explanatory research design and autoregressive distributed lag model for analysis. Results: The results revealed a coefficient of -0.017 for GDPPC and 0.004 for GDPPC squared indicating that economic growth has negative effect on CO2e in the initial stages of growth but positive effect in the high growth regime with the marginal effect being higher in the initial growth regime. The findings suggest a U-shaped relationship consistent with Brundtland Curve Hypothesis (BCH). Conclusions: The findings emphasize the need for sustainable development path that enables present generations to meet own needs without compromising the capacity of future generations to meet their own. Sustainable development may include, investment in renewable energies like wind, solar and adoption of energy efficient technologies in production and manufacturing. The study concludes that BCH is applicable to Kenya and that developing affordable and effective mechanisms to boost sustainable development implementation is necessary to decrease the anthropogenic impact in the environment without any attendant reduction in the economic growth.

An Experimental Study on Measurement of Flow Coefficient Using the Steady-Flow Test Rig (정상유동장치를 이용한 유량계수 측정에 관한 실험적 연구)

  • Park, Sang-Wook;Choi, Ik-Soo;Noh, Ki-Chol;Ryu, Soon-Pil;Yoon, Keon-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.423-429
    • /
    • 2012
  • Miller cycle is considered as an effective means to meet the regulation on Tier II and to reduce $CO_2$ emission. For this cycle, the amount of intake air supplied should be enough increased. Therefore, the intake system with minimized resistance for air flow is under consideration. In this study, the flow coefficients of intake valves were measured in order to obtain the basic data for the cycle simulation and intake port design. The flow coefficients were measured using the steady-flow test rig. As a test result for the poppet valve used the marine engine with medium speed, the flow coefficients are increased to about 0.62 with the valve lift. In addition it is confirmed that the flow coefficients have the characteristic value irrelevant to the S/B ratio.

The Microstructural and Electrical Properties of Ni-Mn-Co Oxide for the Application of NTC Thermistors (NTC 서미스터로 응용을 위한 Ni-Mn-Co 산화물의 미세구조와 전기적 특성)

  • Kim, Kyeong-Min;Lee, Sung-Gap;Kwon, Min-Su;Kim, Young-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.6
    • /
    • pp.361-365
    • /
    • 2017
  • In this paper, we investigated the effect of Co content on the microstructural and electrical properties of $Ni_{0.79}Mn_{2.21-x}Co_xO_4$ (x=0 to 0.25) specimens. Solid-state reaction was used to prepare the bulk specimens. XRD (X-ray diffraction) patterns showed that all compositions had a cubic spinel phase. As a result of the microstructural properties, FE-SEM(field-emission scanning electron microscopy) analysis showed a dense structure, and the mean grain size increased from $5.24{\mu}m$ to $7.33{\mu}m$ with an increase of Co content from x=0 to 0.25. All specimens exhibited the typical NTC thermistor characteristics as the electrical resistance exponentially decreased with increasing temperature. The resistivity and the B-value of $Ni_{0.79}Mn_{1.96}Co_{0.25}O_4$ were $2959{\Omega}{\cdot}cm$ and 3719, respectively.

Sensitivity Analysis (Q10) of Carbon Dioxide Flux with Soil Temperature in the Grassplot (잔디밭에서 지온에 대한 이산화탄소 플럭스의 민감도(Q10) 분석)

  • Kang, Dong-hwan;So, Yoon Hwan;Kwon, Byung Hyuk;Kim, Park Sa
    • Journal of Environmental Science International
    • /
    • v.28 no.9
    • /
    • pp.785-795
    • /
    • 2019
  • In order to analyze the sensitivity of carbon dioxide flux by soil temperature in the grassplot, carbon dioxide flux and soil temperature were observed 24 times from March, 2010 to March, 2011 at nine sites in the grassplot. The average of $CO_2$ in the grassplot is $2.2{\sim}36.7^{\circ}C$, the highest in August, the lowest in January, and the average of carbon dioxide flux is $12{\sim}1479mgCO_2{\cdot}m^{-2}{\cdot}hr^{-1}$, and the carbon dioxide emission from the grassplot to the atmosphere was 10 times higher in summer than in winter. The temperature response coefficient estimated by the exponential function of carbon dioxide flux according to soil temperature was ranged from 0.1065 to 0.1274, and the increase tendency of $CO_2$ flux with soil temperature was linear at $0{\sim}20^{\circ}C$ and exponential at $20{\sim}40^{\circ}C$. The $Q_{10}$ values for each of nine observation sites on the grassplot was in the range of 2.901 ~ 3.575, and the $Q_{10}$ value using the total data observed in the lawn was estimated to be 3.374. In the homogeneous grassplot area, the average of $Q_{10}$ values by observation point and the $Q_{10}$ value by the total data were estimated similarly.

A Study on the Pro-Environmental Energy Supply Program of Urban Enterprises on the concept of BAT(Best Available Technology): Application of Air Environmental Indices and Benefit-Cost Analysis Based (한 도시 사업체 에너지 수급의 최적화 방안 연구 - 대기오염지수와 경제성 평가를 중심으로 -)

  • Kwon, Yong-Sik;Kim, Yong-Bum;Chung, Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.89-102
    • /
    • 1998
  • The purpose of this study is to seek AEI(Air Environmental Indices), PSI(Pollutant Standard Index) and the urban air quality control goal(the best available alternative energy program) by assessing the best ratio of energy types used in urban enterprises, based on harmful health effect and air quality standard and costs. This study is focused on an urban area(Puchun), where area sourcees are associated with heavy traffic, large population, and its industrial sources with large emissions. In the first step, air modeling, estimation of AEI and PSI, and benefit-cost analysis were carried out. In the second step, we assessed that 660 scenarios about the ratio of B-C oil, light oil and LNG used in urban enterprises with regard to air quality and cost. In the third step, the best available alternative energy program was selected for the ratio of energy species(B-C oil, light oil and LNG) by using the lexicographic method. From the emission analysis, main source of $NO_2$ is identified as industries and air quality is evaluated according to the ratio of B-C oil, light oil and LNG used in urban enterprise. The modeling data of TSP, $SO_2$, $NO_2$, CO, $O_3$, by ISC3 and PBM are respectively $118{\mu}g/m^3$, 0.027ppm, 0.025ppm, 2.0ppm, 0.55ppm in indurstrial area. That data are close to Environmental Air Quality Standard. By means of sensitivity analysis, we obtained the difference in concentration between the areas(Nae-dong, Joong-dong) according to the ratio of B-C oil, light oil and LNG used in the industries. From the result of alternatives assessment the lowest AEI value and cost, the ratio of B-C oil, light oil and LNG are 2.5%, 20%, 77.5%, respectively.

  • PDF

The Study of Donor-Acceptor Chromophores and Diketopyrrolopyrrole(DPP) Analogues (Donor-Acceptor 발색단과 디케토피롤로피롤(DPP) 유도체에 관한 연구)

  • Kim, HunSoo;Kim, SeungHoi;Park, SooYoul
    • Tribology and Lubricants
    • /
    • v.32 no.5
    • /
    • pp.141-146
    • /
    • 2016
  • The diketopyrrolopyrrole (DPP) pigment is a bicyclic 8-π-electron system containing two lactam units. Typical DPP derivative pigments have melting points of over 350°C and very low solubility in most solvents, and show absorption in the visible region with a molar extinction coefficient of 33,000 dm2mol−1 and strong photoluminescence with maxima in the range 500–600 nm. X-ray structure analyses of DPP show that the whole molecule is almost in one plane. The phenyl rings are twisted out of the heterocyclic plane and the intermolecular hydrogen bonding between neighboring lactam NH and carbonyl units influences the structure of the DPP pigment in the solid state. In this study, mono-N-alkylation and mono-N-arylation were undertaken for Pigment Red 264 or Pigment Orange 73 with alkyl halide and aryl halide, respectively, in the presence of sodium tert-butoxide as a base catalyst to improve the solubility of DPP pigments and their application as CO2 indicators. The synthetic yield was in the range 11–88%. The indicator dyes are highly soluble in organic solvents and shows pH-dependent absorption (λmax 501 and 572 nm for the protonated and deprotonated forms, respectively) and emission (λmax 524 and 605 nm for the protonated and deprotonated forms, respectively) spectra. The mono-N-alkylated and mono-N-arylated DPP pigment was identified by 1H-NMR (1H-Nuclear Magnetic Resonance Spectrometer), FT-IR (Fourier Transform Infrared Spectroscopy), and MS (Mass Spectrometry). According to the results of color and hue properties obtained by a color matching analyzer, the synthesized DPP pigment material can be used as a CO2 indicator.

Analysis of the relationship among water-efficiency in the non-agricultural sector, economic growth, electricity generation, and CO2 emission - evidence from Korea - (우리나라에서 비농업 부문의 물 효율성, 경제성장, 전력생산 및 CO2배출 간의 관계 분석)

  • Jung, Yonghun;Lee, Seong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.12
    • /
    • pp.1229-1235
    • /
    • 2018
  • We have examined dynamic relationships among water-efficiency, economic growth, electricity generation, and $CO_2$ emissions in Korea using various time-series analysis methods for 1990-2014. While previous studies have been limited to economic growth, $CO_2$ emissions, and electricity generation, this study contributed to explain the relationship between existing variables and water-efficiency. We find that the four variables reach a balanced state in the long run through short-term adjustment, $CO_2$ emissions and economic growth are responsible for water efficiency, and that $CO_2$ emissions, economic growth and water efficiency are the causes of electricity generation. The long-term impact coefficient estimates on water-efficiency show that the increase in electricity generation and the decrease in $CO_2$ emissions increase water-efficiency. Although economic growth has increased water-efficiency, moreover, we have identified an inverted U-shaped relationship between economic growth and water-efficiency, which suggests that economic growth above a certain level reduces the rate of increase in water-efficiency.

The Performance Test and the Feasibility Study for a Dual-Source Heat Pump System Using the Air and Ground Heat Source (공기 및 지열 이용 Dual-Source 히트펌프 시스템의 성능실험 및 경제성 분석)

  • Nam, Yujin;Chae, Ho-Byung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.212-217
    • /
    • 2014
  • Recently, the use of renewable energy has been increased due to growing concern on the energy-saving at buildings and the reduction of $CO_2$ emission. In the field of architecture, to reduce the energy consumption of heating, cooling and hot water supply, heat pump systems with renewable energy has been developed and used in various applications. However, there have been many of researches on the large-scale commercial heat pump systems, but the research and the field application of a compact heat pump system is rare. Therefore, in order to develop the compact heat pump for the small-scale residential building, this study conducted the performance test and feasibility study for a hybrid heat pump using the heat source of air, solar and ground. In the results of experiments through a trial product, the average COP of cooling mode with ground heat source was 4.75, and it of heating mode was 4.03. Furthermore, the average COP of cooling mode with air heat source was 2.60, and it of heating mode was 2.92. Finally, payback period of the system was calculated as 9.2 years.

Determination of Biotin by HPLC (고성능 액체크로마토크래피를 이용한 Biotin의 정량)

  • Kim, Dong-Soo;Lee, Young-Ja;Jeong, Dong-Youn;Lee, Dong-Yup;Ahn, Moon-Kyu
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.499-503
    • /
    • 2003
  • A high performance liquid chromatography gradient elution method with fluorescence detection for the determination of biotin in pure form and pharmaceutical preparations has been developed. BrMDMC gives intense fluorescence and the fluorescence was monitored with excitation at 360 nm and emission at 410 nm. The calibration curve for biotin shows good linearity over the range of 5 ~ 400 ng with correlation coefficient of 0.999. The detection limit of biotin was 2 ng and the result of recovery was 98.75% with relative standard deviation of 1.1%.

Durability Performance Evaluation On Early-Aged Concrete with Rice Husk Ash and Silica Fume (Rice Husk Ash와 실리카퓸을 혼입한 초기재령 콘크리트의 내구성능 평가)

  • Saraswathy, Velu;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.343-351
    • /
    • 2015
  • Currently, lots of researches have been performed for reducing cement usages due to increasing social/engineering problems caused by $CO_2$ emission. Supplementary cement materials like fly ash, slag, and silca fume are usually employed for cement replacement, and nowadays rice husk ash (RHA) is widely studied for enhancement of concrete performance as mineral admixture. In this paper, concrete samples with RHA and SF which is known for its engineering advantages are prepared and a resistance to chloride attack is evaluated in early-aged concrete. For the work, replacement ratios of 10~30% for RHA concrete and 2~8% for SF concrete are considered, and various durability tests such as density, void, sorptivity, current measurement, and chloride diffusion coefficient are performed including mechanical test like compressive and tensile strength. Replacement of RHA 10~15% shows better improvement of corrosion resistance and strength than that of SF 2~4% and normal concrete, which shows a strong applicability for utilization as construction materials.