• 제목/요약/키워드: $CO_2$ concentration distribution

검색결과 314건 처리시간 0.027초

Comparison of Model-simulated Atmospheric Carbon Dioxide with GOSAT Retrievals

  • Shim, Chang-Sub;Nassar, Ray;Kim, Jhoon
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권4호
    • /
    • pp.263-277
    • /
    • 2011
  • Global atmospheric $CO_2$ distributions were simulated with a chemical transport model (GEOS-Chem) and compared with space-borne observations of $CO_2$ column density by GOSAT from April 2009 to January 2010. The GEOS-Chem model simulated 3-D global atmospheric $CO_2$ at $2^{\circ}{\times}2.5^{\circ}$ horizontal resolution using global $CO_2$ surface sources/sinks as well as 3-D emissions from aviation and the atmospheric oxidation of other carbon species. The seasonal cycle and spatial distribution of GEOS-Chem $CO_2$ columns were generally comparable with GOSAT columns over each continent with a systematic positive bias of ~1.0%. Data from the World Data Center for Greenhouse Gases (WDCGG) from twelve ground stations spanning $90^{\circ}S-82^{\circ}N$ were also compared with the modeled data for the period of 2004-2009 inclusive. The ground-based data show high correlations with the GEOS-Chem simulation ($0.66{\leq}R^2{\leq}0.99$) but the model data have a negative bias of ~1.0%, which is primarily due to the model initial conditions. Together these two comparisons can be used to infer that GOSAT $CO_2$ retrievals underestimate $CO_2$ column concentration by ~2.0%, as demonstrated in recent validation work using other methods. We further estimated individual source/sink contributions to the global atmospheric $CO_2$ budget and trends through 7 tagged $CO_2$ tracers (fossil fuels, ocean exchanges, biomass burning, biofuel burning, net terrestrial exchange, shipping, aviation, and CO oxidation) over 2004-2009. The global $CO_2$ trend over this period (2.1 ppmv/year) has been mainly driven by fossil fuel combustion and cement production (3.2 ppmv/year), reinforcing the fact that rigorous $CO_2$ reductions from human activities are necessary in order to stabilize atmospheric $CO_2$ levels.

상용 Al2O3 분말의 비교분석 및 이를 이용하여 제조한 슬러리의 분산 특성 (Comparative Analysis of Commercial Al2O3 Powders and the Dispersion Characteristics of Slurries Produced Using Them)

  • 권모세;유승준;김진호;정경훈;이종근;김응수
    • 한국재료학회지
    • /
    • 제34권1호
    • /
    • pp.27-33
    • /
    • 2024
  • Al2O3 has excellent sintering properties and is important in semiconductor manufacturing processes that require high-temperature resistance and chemical inertness in a plasma environment. In this study, a comprehensive analysis of the chemical characteristics, physical properties, crystal structure, and dispersion stability of three commercially available Al2O3 powders was conducted. The aim was to provide a technological foundation for selecting and utilizing appropriate Al2O3 powders in practical applications. All powders exhibited α-Al2O3 as the main phase, with the presence of beta-phase Na2O-11Al2O3 as the secondary phase. The highest Na+ ion leaching was observed in the aqueous slurry state due to the presence of the secondary phase. Although the average particle size difference among the three powders was not significant, distinct differences in particle size distribution were observed. ALG-1SH showed a broad particle size distribution, P162 exhibited a bimodal distribution, and AES-11 displayed a uniform unimodal distribution. High-concentration Al2O3 slurries showed differences in viscosity due to ion release when no dispersant was added, affecting the electrical double-layer thickness. Polycarboxylate was found to effectively enhance the dispersion stability of all three powders. In the dispersion stability analysis, ALG-1SH exhibited the slowest sedimentation tendency, as evidenced by the low TSI value, while P162 showed faster precipitation, influenced by the particle size distribution.

수도권지역에서 수치 토지피복지도 작성을 통한 대기환경부문 활용사례 연구 - MM5내 기온 및 바람장의 민감도 분석과 식생분포에 기인한 VOC 배출량 및 CO2 플럭스의 실시간 산정을 중심으로 - (A Study on Examples Applicable to Numerical Land Cover Map Data for Atmospheric Environment Fields in the Metropolitan Area of Seoul - Real Time Calculation of Biogenic CO2 Flux and VOC Emission Due to a Geographical Distribution of Vegetable and Analysis on Sensitivity of Air Temperature and Wind Field within MM5 -)

  • 문윤섭;구윤서
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.661-678
    • /
    • 2006
  • Products developed in this research is a software which can transfer the type of shape(.shp) into the type of ascii using the land cover data and the topography data in the metropolitan area of Seoul. In addition, it can calculate the $CO_2$ flux according to distribution of plants within the land cover data. The $CO_2$ flux is calculated by the experimental equation which is compose of the meteorological parameters such as the solar radiation and the air temperature. The net flux was shown in about $-19ton/km^2$ by removing $CO_2$ through the photosynthesis during daytime, and in 2 ton/km2 by producing it through the respiration during nighttime on 10 August 2004, the maximum day of air temperature during the period of 3yr(2001 to 2004), in the metropolitan area of Seoul. Spatial distribution of the air temperature and the wind field is simulated by substituting the middle classification of the land cover map data, upgraded by the Korean Ministry of Environment(KME), for the land-use data of the United States Geological Survey(USGS) within the Meteorological Mesoscale Model Version 5(MM5) on 10 August 2006 in the metropolitan area of Seoul. Difference of the air temperature between both data was shown in the maximum range of $-2^{\circ}C\;to\;2.9^{\circ}C$, and the air temperature due to the land use data of KME was higher than that of USGS in average $0.4^{\circ}C$. Also, those of wind vectors were meanly lower than that of USGS in daytime and nighttime. Furthermore, the hourly time series of Volatile Organic Components(VOCs) is calculated by using the Biosphere Emission and Interaction System Version 2(BEIS2) including the new land cover data and the meteorological parameters such as the air temperature and so]ar insolation. It is possible to calculate the concentration of ozone due to the biogenic emission of VOCs.

유동층 연소로에서 유.무연탄 혼합 연소법을 이용한 국내산 저질 무연탄의 활용에 관한 연구 (A Study on the Use of Low-Grade Domestic Anthracite by Anthracite - Bituminous Coal Blend Combustion in a Fluidized Bed Combustor)

  • 정종현;조상원
    • 한국환경과학회지
    • /
    • 제6권3호
    • /
    • pp.267-276
    • /
    • 1997
  • It has been studded that combustion and the production of air pollution of anthracite - bituminous coal blend In a fluidized bed coal combustor, The objects of thIns study were to investigate mixing characteristics of the particles as well as the combustibility of the low grade domestic anthracite coal and Imported h19h calorific bltununous coal in the fluidized bed coal combustor. They were used as coal samples ; the domestic low grade anthracite coal with heating value of 2,010kca1/kg and the Imported high grade bituminous coal with beating value of 6,520kca1/kg. Also, the effects of air flow rate and anthracite fraction on the reaching time of steady state condition have been studied. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 300sc1h which was the fastest. It has been found that $O^2$ and $CO^2$ concentration were reached steady state at about 100 minute. It has been found that $O^2$ concentration decreased and $CO^2$ concentration increased as the height of fluidlzed bed Increased. It was found that splash zone was mainly located from 25cm to 35cm above distributor. Also, as anthracite traction Increased, the mass of elutrlatlon particles Increased, and $CO^2$ concentration decreased. As gk flow rate Increased,$O^2$ concentration decreased and $CO^2$ concentration increased. Regardless of anthracite fraction and flow rate, the uncombustible weight percentage according to average diameter of elutriation particles were approldmately high In the case of One Particles. As anthracite traction and k now rate Increased, elutriation ratio Increased. As anthracite fraction was increased, exit combustible content over feeding combustible content was Increased. Regardless of anthracite fraction, size distribution of Ued material from discharge was almost constant. Over bed temperature 85$0^{\circ}C$ and excess air 20% , the difference of combution efficiencies were little. It is estimate that the combustion condition In anthracite-bituminous coal blend combustion is suitable at the velocity 0.3m/s, bed temperature 85$0^{\circ}C$, the excess air 20%.

  • PDF

GC/ECD와 HRGC/HRMS 분석을 이용한 변압기 절연유 중 PCBs 농도 및 이성체 분포 (PCBs concentration and congener distribution in transformer insulation oil samples using GC/ECD and HRGC/HRMS analysis)

  • 김경수;김형섭;송병주;정미정;김종국;박석운;신선경
    • 분석과학
    • /
    • 제18권3호
    • /
    • pp.232-240
    • /
    • 2005
  • 절연유 중 PCBs 총 농도를 GC/ECD와 HRGC/HRMS를 이용하여 정량한 결과 각각 N.D. ${\sim}154.04{\mu}g/g$$0.087{\sim}223.6{\mu}g/g$(TEQ 농도는 0.00067~6.8 ng WHO-TEQ/g)으로 검출되었으며, 6개의 시료에서 2 ppm을 초과하였다. 고농도 시료일수록 정량방법의 차이로 인해 ECD와 HRMS의 분석결과가 차이를 나타내었다. 절연유 중 PCBs의 피크패턴 및 군집분석을 사용하여 시료에 함유된 PCBs 제품형태를 추정할 수 있었으며, Aroclor 1248 제품은 함유되어 있지 않았다. Co-PCBs 이성체 분포에 있어서 non-ortho 치환 이성체에 비해 mono-ortho 치환 이성체가 높은 비율을 나타내었으며, PCB-167 이성체가 가장 높은 비율을 차지하였다. 또한 절연유 중 Co-PCBs의 이성체패턴은 소각로 배출가스, 환경 대기시료 뿐만 아니라 PCBs 제품(Aroclor, Kanechlor)과도 다른 이성체 패턴을 나타내었다.

고농도 알코올 혼합 석유제품이 자동차 성능 및 배출가스에 미치는 영향 연구 (The Study on Effect of Emissions and Performance of a Conventional Vehicle using the High Concentration Alcohol Blended Petroleum Product)

  • 김성우;도진우;김기호;하종한
    • 한국수소및신에너지학회논문집
    • /
    • 제26권6호
    • /
    • pp.629-637
    • /
    • 2015
  • As concern about energy security and global warming many countries have been making effort to reduce fossil fuel. In the case of US, as one of the efforts, the standards of the alcohol vehicle fuels(including blended with gasoline) have been established. Alcohol is known that make some trouble concerning startability, durability and corrosion when using as fuel of a conventional vehicle. For these reason, alcohol usage needs not only the fuel standard, but also a modified car. In the case of Korea, although there are no the standard and the modified vehicle yet, high concentration alcohol blended fuel has being sold at illegal market. In this study, exhaust gas and performance of the conventional vehicle that alcohol(methanol and isopropyl alcohol) blends were fueled were measured to notify danger of using them without preparation of institutional arrangements. Also, to analyze correlation characteristics of the fuels and them, property test of the fuels was conducted. The test result show that bad-startability caused by low RVP and high T10 affected increase in NMOG and CO. NOx was increased under the highest short term fuel trim caused by high Oxygen content and low NHV of alcohol. According to increasing as alcohol content, fuel economy and acceleration ability were decreased but $CO_2$ was not significantly decreased.

서울시 대기 중 $H_2O_2$의 농도 (Hydrogen Peroxide Concentrations in Air in Seoul)

  • 강충민;김희강
    • 한국대기환경학회지
    • /
    • 제16권1호
    • /
    • pp.61-68
    • /
    • 2000
  • Gas-phase hydrogen peroxide(H2O2) concentrations were measured to investigate it's distribution in the ambient air in downtown Seoul(Kwanghwamum and Mullae-dong). These measurements were made during four season, from April 30, 1998 to January 29, 1999, using Cold Trap and HPLC. Measurements were also made of other photochemical oxidants and trace gases(O3, NO2, CO and SO2) and meteorological parameters(relative humidity, temperature, solar radiation and wind speed). The mean of all observations was 0.10 ppbv and the range measured was below the level of detection(>0.01 ppbv) to 0.47ppbv. The higher seasonal mean concentrations showed during the summer(0.21 ppbv) and concentrations of H2O2 showed a diurnal variation with maximum concentrations in the afternoon(12:30∼14:00). The results from the corrrelation analysis showed that the concentration of gaseous H2O2 is strongly dependent on the other air pollutants(NO2, CO and O3) and meteorological parameters(relative humidity, temperature and solar radiation.)

  • PDF

YH1885의 체내동태(제1보):흰쥐에서 $^{14)C-YH1885$의 단회투여시 흡수, 조직분포 및 배설 (Pharmacokinetic Study of YH1885 (I): Absorption, Distribution and Excretion of $^{14)C-YH1885$ in Rats)

  • 안병락;;;;;이종옥
    • 약학회지
    • /
    • 제41권3호
    • /
    • pp.335-344
    • /
    • 1997
  • The absorption, distribution and excretion of $^{14}C$ labeled YH1885 {5,6-Dimethyl-2(4-fluorophenylamino)-4-(1-methyl-1,2,3,4-tetrahydroisoquinolin-2-yl)pyrimidine hydroc hloride), a new proton pumpinhibitor, were investigated in rats after a single administration of $^{14}C$-YH1885. 1. After intravenous administration of 5mg/kg, the blood level of radioactivity declined in a biphasic fashion with the mean terminal elimination half-life of 12.4hr. 2. After oral administration of 20mg/kg, the maximum blood level of radioactirity was reached at 4.0hr in female rats. The blood level of radioactivity-time profiles in male and female rats were similar, and the absorptionof $^{14}C$-YH1885 was not affected by food. 3. Appproximately 89% and 1% of radioactivity of the total dose were excreted in feces and urine, respectively. 4. Biliary excretion of radioactivity was 47.9% of the dose. Enterohepatic circulation of radioactivity was 49.6%. 5. Radioactivity was excreted maily into feces via bile. 6. The concentration of radioactivity in most tissues reached the peak level at 4.0hr after dosing, and then declined. Autoradiograms of male rats showed that the radioactivity levlels in the fat, harder's gland, liver and G-Itract were higher than those in the other tissues and the elimination of radioactivity from fat and liver was slow. 7. Autoradiograms of a pregnant rat showed that radioactivity was transferred to mammary gland, placenta and fetus. The radioactivity level in the mammary gland was higher than that in the blood.

  • PDF

석탄입자 크기가 가스화에 미치는 영향 (The Effect of the Size of Coal Particles on Gasification Reactions)

  • Cho, Seok-Yeon;Seo, Kyung-Won
    • 에너지공학
    • /
    • 제6권1호
    • /
    • pp.77-86
    • /
    • 1997
  • 본 연구에서는 Alaska Usibelli 아역청탄이 사용되는 실린더형 석탄 가스화기내에서 석탄의 입자크기가 반응성 유동장과 주요 생성물의 농도분포에 미치는 영향을 고찰하기 위하여 미분탄 입자의 크기를 40 $\mu\textrm{m}$, 60 $\mu\textrm{m}$, 100 $\mu\textrm{m}$, 120 $\mu\textrm{m}$ 및 140 $\mu\textrm{m}$로 각각 나누어 전산모사를 수행하였다. 모사결과, 가스화기내에서 석탄의 입자크기가 가스화 생성물의 농도분포에 커다란 영향을 미침을 알 수 있었다. 입자의 크기가 100 $\mu\textrm{m}$일 때 가스화기 출구에서 주 생성물인 CO와 H$_2$가 최대로 생성되고 이때 이들의 평균 몰분율은 각각 0.62, 0.16(dry basis, inert free)으로 예측되었다 또한 냉가스 효율도 입자크기가 100 $\mu\textrm{m}$일때 최고치 83%로 예측되었다.

  • PDF

일방향 도로터널내 화재 발생시 역류를 막는 환기속도결정에 관한 축소모형실험 (The Reduced Model Test for the Determination of Ventilation Velocity to Prevent Backflow in Uni-directional Road Tunnel during a Fire Disaster)

  • 유영일;이희근
    • 터널과지하공간
    • /
    • 제8권2호
    • /
    • pp.107-117
    • /
    • 1998
  • In the case of a fire disaster in a uni-directional road tunnel, it is important to determine the critical ventilation velocity to prevent the backflow travelling toward the tunnel exit where vehicles are stopped. The critical ventilation velocity is horizontal velocity to prevent hot smoke from moving toward the tunnel exit. According to Froude modelling, the model tunnel whcih was 300mm in diameter and 21 m in length was made of acryl tubes. Inner section of acryl tubes was clothed with polycarbonate. 1/20 scaled model vehicles were installed to simulate the situation that vehicles are stopped in the tunnel exit. Methanol in a pool type burner was burned in the middle of tunnel to simulate a fire hazard. In this study, the basis of determining the critical ventilation velocity is the ventilation flow rate that is able to maintain the allowable CO concentration in the tunnel section. We assumed that the allowable CO concentration was backflow dispersion index. Futhermore, We intended to find out CO distribution and temperature distribution according as we changed ventilation velocity. The results of this study were that no backflow happened when ventilation velocity was 0.52 m/s in the case of 5.75 kW. If we adapt these results of a fire disaster releasing 10MW heat capacity in real tunnel which is 400m in length, no backflow happens when ventilation velocity is 2.31m/s. After we figured out dimensionless heat release rate and dimensionless ventilation velocity of model test and those of real test to verify experimental correctness, we tried to find out correlation between experimental results of model tunnel and those of real tunnel.

  • PDF