• 제목/요약/키워드: $CO_2$ Flux

검색결과 645건 처리시간 0.027초

FCW의 가스 발생제가 스패터링에 미치는 영향 (Effects of gas formers of flux cored wire on spattering)

    • Journal of Welding and Joining
    • /
    • 제16권5호
    • /
    • pp.93-99
    • /
    • 1998
  • Effects of gas formers of MgCO$_3$, CaCO$_3$ and Li$_2$CO$_3$ on the spattering phenomena were investigated for non-shielded flux cored arc welding. Spattering phenomena were pictured using high speed camera as a speed of 3000 frames per sec. As experimental results, spattering modes were classified into 4 types. The modes were spattering by arc force, gas explosion, short circuit and pore escape. The amount of spatters by arc force was 30%, gas blowing force was 40%, short circuit 10%, pore escape was 10% and others were 10%. When Li$_2$CO$_3$ was added, the amount of spatters was largest, and it decreased in the order of CaCO$_3$ and MgCO$_3$.

  • PDF

Poly(1-methyl-4-vinylpyridium iodide-co-styrene)막을 통한 유기음이온의 투과특성 (Transport Characteristics of Organic Anions through Poly (1-methyl-4vinylpyridium iodide-co-styrene) Membrane)

  • 이광재;한정우박돈희조영일
    • KSBB Journal
    • /
    • 제6권2호
    • /
    • pp.207-213
    • /
    • 1991
  • In this study poly (1-methyl-4-vinylpyridinium iodide-co-styrene) membrane with pyridinium cation as a fixed carrier was synthesized and the transport characteristics of the membrane was examined over various factors. As the concentration of the fixed carrier in the membrane was increased, the water content was increased. Meanwhile, the counter current of the organic anion and the chloride ion, the following results were obtained. Initial flux of Cl-, organic anion and Na+ decreased with the increasing thickness of membrane, and as the concentration of the fixed carrier increases, the initial flux of Cl- and organic anion increase but the initial flux of Na+ decreased. The flux equation of the organic anion, CCl3COO- was obtained from saturation kinetics as follows;$V_{o}=\frac{(8.67{\times}10^{-5}){\cdot}[NaCl]}{9.63{\times}10^{-2}+[NaCl]} mol/cm^2h$

  • PDF

수평관내 $CO_2$의 초임계 영역내 열전달에 관한 연구 (The heat transfer characteristics of supercritical $CO_2$ in a horizontal tube)

  • 오후규;이동건;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.526-532
    • /
    • 2005
  • The cooling heat transfer coefficient of $CO_2$(R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter. a pre-heater and gas cooler(test section). The test section consists of a smooth, horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $400\;kg/m^{2}s$ and the inlet cooling pressure of 7.5 MPa to 10.0 MPa. The variation of heat transfer coefficient tends to decrease as cooling pressure of $CO_2$ increases. The heat transfer coefficient with respect to mass flux increases as mass flux increases. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with that predicted by Blasius's correlation. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Bringer-Smith.

수평관내 이산화탄소의 증발 압력강하 (Evaporation Pressure Drop of Carbon Dioxide in a Horizontal Tube)

  • 구학근;손창효
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.63-69
    • /
    • 2007
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

  • PDF

앙상블 칼만 필터 기반 탄소추적시스템의 아시아 지역 탄소 순환 진단에의 적용 (Application of Carbon Tracking System based on Ensemble Kalman Filter on the Diagnosis of Carbon Cycle in Asia)

  • 김진웅;김현미;조천호
    • 대기
    • /
    • 제22권4호
    • /
    • pp.415-427
    • /
    • 2012
  • $CO_2$ is the most important trace gas related to climate change. Therefore, understanding surface carbon sources and sinks is important when seeking to estimate the impact of $CO_2$ on the environment and climate. CarbonTracker, developed by NOAA, is an inverse modeling system that estimates surface carbon fluxes using an ensemble Kalman filter with atmospheric $CO_2$ measurements as a constraint. In this study, to investigate the capability of CarbonTracker as an analysis tool for estimating surface carbon fluxes in Asia, an experiment with a nesting domain centered in Asia is performed. In general, the results show that setting a nesting domain centered in Asia region enables detailed estimations of surface carbon fluxes in Asia. From a rank histogram, the prior ensemble spread verified at observational sites located in Asia is well represented with a relatively flat rank histogram. The posterior flux in the Eurasian Boreal and Eurasian Temperate regions is well analyzed with proper seasonal cycles and amplitudes. On the other hand, in tropical regions of Asia, the posterior flux does not differ greatly from the prior flux due to fewer $CO_2$ observations. The root mean square error of the model $CO_2$ calculated by the posterior flux is less than the model $CO_2$ calculated by the prior flux, implying that CarbonTracker based on the ensemble Kalman filter works appropriately for the Asia region.

Flip Chip PKG 신뢰성 향상을 위한 Flux Immunity 개선 MUF 구현 방안 연구 (A Study on Flux Immunity MUF for Improving Flip Chip PKG Reliability)

  • 이준신;이현숙;김민석;김성수;문기일
    • 마이크로전자및패키징학회지
    • /
    • 제29권2호
    • /
    • pp.49-52
    • /
    • 2022
  • Flip Chip 제품 난이도 증가에 따라 신뢰성 관점에서 안정적인 Package (이하 PKG) 소재 기술에 대한 관심이 점차 높아지는 추세이다. 현재 flip chip PKG의 주요 신뢰성 불량은 Sn bridge와 Cu 확산 이다. 위 2가지 형태 모두 본질적으로는 bump 주변 잔류한 flux residue에 의하여 발생한 미세 공극이 유발하는 불량이다. 이러한 형태의 신뢰성 불량 발생 문제점을 최소화하기 위해 Molded Under-Fill (이하 MUF) 소재의 핵심 조성과 flux 간 상관 관계를 검토하였다. 금번 연구를 통하여 MUF 소재의 main 구성 요소인 base resin, filler와 flux에 대한 상관 관계를 정의 하였으며, 이러한 lesson learn을 토대로 flux immunity가 개선된 MUF 소재 조성을 설계할 수 있었다. 현재 해당 소재 조성으로 흡습 신뢰성 85%/85%/24hrs 확보와 파괴 분석으로 bump 주변 미세 공극의 미 발생을 확인 하였다. 본 연구 결과는 양산 단계에서의 flip chip 공정 수율 향상과 MUF와 flux 간 상용성 연구에 대한 이해를 돕는데 기여할 것으로 예상된다.

갯벌, 논 및 산림 부지에서 지표와 대기 사이의 이산화탄소 플럭스 계절/공간 변동 분석 (Seasonal and Spatial Variations of CO2 Fluxes Between Surface and Atmosphere in Foreshore, Paddy Field and Woods Sites)

  • 강동환;권병혁;유훈선;김박사;김광호
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.963-975
    • /
    • 2011
  • For this research, they were monitored $CO_2$ flux and environmental factors ($CO_2$ concentration, soil temperature, soil moisture, soil organic carbon, soil pH, soil Eh) in foreshore, paddy field and woods sites at the winter season (January 2009) and the summer season (September 2009). Seasonal and spatial variations for monitored data were analyzed, and linear regression functions of $CO_2$ flux as environmental factors were estimated. $CO_2$ fluxes averaged between surface and atmosphere monitored in foreshore and paddy field at the winter season were shown $-8\;mgCO_2m^{-2}hr^{-1}$ and $-25\;mgCO_2m^{-2}hr^{-1}$, respectively. $CO_2$ fluxes averaged between surface and atmosphere monitored in foreshore and paddy field at the summer season were shown $47\;mgCO_2m^{-2}hr^{-1}$ and $117\;mgCO_2m^{-2}hr^{-1}$, respectively. Thus, $CO_2$ was sunk from atmosphere to surface at the winter season and it was emitted from surface to atmosphere at the summer season. $CO_2$ fluxes in woods site were emitted $145\;mgCO_2m^{-2}hr^{-1}$ at the winter season and $279\;mgCO_2m^{-2}hr^{-1}$ at the summer season.

비휘발성이며 불연성인 새로운 납땜 Flux의 개발 (Development of a New Nonvolatile and Nonflammable Soldering Flux)

  • 배재흠;장용운;이통영;조기수
    • 청정기술
    • /
    • 제6권2호
    • /
    • pp.101-106
    • /
    • 2000
  • 비휘발성이고 불연성의 새로운 납땜 플럭스를 개발하였다. 이 플럭스는 기존의 플럭스에서 사용하는 VOC 물질인 이소프로판올/메타놀과 같은 용제를 사용하지 않고 VOC 규제물질이 아닌 디클로로프로판 용제를 사용하여 제조하였다. 이 플럭스는 기존의 이소프로판올/메타놀 용제로 제조한 플럭스에 비하여 전기절연성, 작업성, 신뢰성면에서 우수하였고 작업장의 환경 안정성 면에서 우수하며 경제적임을 확인할 수 있었다.

  • PDF

수평관내의 $CO_2$의 증발 열전달에 관한 연구 (Study on the Evaporation Heat transfer of $CO_2$ in a Horizontal tube)

  • 장승일;최선묵;김대희;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.240-241
    • /
    • 2005
  • The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 kg/$m^2s$, saturation temperature of 0$^{circ}C$ to 20$^{circ}C$, and heat flux of 10 to 30 kW/$m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

수평 평활관내 $CO_2$ 증발열전달 및 압력강하에 관한 연구 (Study on $CO_2$ Evaporation Heat Transfer and Pressure Drop in a Horizontal Smooth Tube)

  • 이상재;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.615-621
    • /
    • 2007
  • Experimental study on the heat transfer characteristics of $CO_2$ in a horizontal smooth tube was carried out to investigate the heat transfer coefficient and pressure drop during evaporation of $CO_2$. The experiment apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes ($200{\sim}1200kg/m^2s$), heat flukes ($10{\sim}100kW/m^2$) and saturation temperatures (-5, 0, $5^{\circ}C$). With increasing the heat flux, the evaporation heat transfer coefficient increased. But the variation of the heat transfer coefficient on the increase of the mass flux was not large. And the significantly drops of the heat transfer coefficient was observed at any heat flux and mass flux because of the change of the flow pattern in the tube. With increasing the saturation temperature, the heat transfer coefficient increased due to the promotion of a nucleate boiling. The measured pressure drop during evaporation increased with increasing the mass flux and decreasing the saturation temperature.