• Title/Summary/Keyword: $CO_2$ 모니터링

Search Result 366, Processing Time 0.029 seconds

Preliminary Results of the Pre-injection Monitoring Survey at an Offshore CO2 Injection Site in the Yeongil Bay (영일만 해상 CO2 주입 실증 사이트에서의 주입 전 모니터링 탐사 예비결과)

  • Park, Myong-Ho;Lee, Chang Shik;Kim, Byoung-Yeop;Kim, Ji-Hoon;Kim, Kyu Jung;Shinn, Young Jae
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.247-258
    • /
    • 2018
  • In the demonstration-scale offshore $CO_2$ storage project, the monitoring team studies geophysical and geochemical monitoring of $CO_2$ injections in the Yeongil Bay, in which a $CO_2$ test injection (about 100t) was performed in January, 2017 and further injections in larger scales are planned for 2018 and 2019. In this study, the development status of the Korea-type Hydro-Geophone OBS (Ocean Bottom Sensor) and the geochemical baseline survey (focused on some anions of sediment pore water) are suggested as the preliminary results of the pre-injection test.

Geophysics for Carbon Capture and Storage in Korea (국내 CO2 지중저장과 지구물리탐사의 역할)

  • Hwang, Se-Ho;Park, Kwon-Gyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.16-19
    • /
    • 2009
  • Recently, CO2 geologic storage (geologic sequestration) has been concerned as one of methodologies for reducing greenhouse gas. We expect that geophysical approach plays an important role in the site selection, characterization, and monitoring during CO2 injection or post-injection. Especially we believe that monitoring and verification technologies such as surface and borehole geophysical methods are an important part of making CO2 geologic storage an acceptable method.

  • PDF

Global monitoring of carbon monoxide (CO) by MOPITT (모피트를 이용한 일산화탄소의 전지구적 모니터링)

  • 최성득;장윤석;이상희;최기혁
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.413-414
    • /
    • 2003
  • 최근의 대기오염과 기후변화는 특정 지역에만 국한되지 않고 전지구 규모로 발생하고 있다. 따라서 인공위성에 탑재된 원격 센서들을 이용한 대기환경 모니터링이 주목을 받고 있다. 일산화탄소 (CO)는 OH 농도와 직접적인 관련이 있는 대류권 화학에서 매우 중요한 미량기체이며, 대기 중 lifetime이 약 2개월이므로 산불이나 대규모 공업단지에서 생성된 CO를 포함한 오염물질들의 추적자로 사용될 수 있다. 이러한 취지에서 MOPITT (Measurement of Pollution in The Troposphere) 기기가 개발되어, 1999년에 지구관측위성인 Terra에 탑재되어 CO 및 CH$_4$ 모니터링을 수행하고 있다. (중략)

  • PDF

International developments in geological storage of $CO_2$ ($CO_2$의 지질학적인 저장에 있어서의 국제적인 개발들)

  • Freund, Paul
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 2006
  • Geological storage of captured $CO_2$ is a new way of reducing greenhouse gas emissions to protect the climate, but is based on the established technology associated with injection of fluids underground. The geological formations of interest for this technique include operational and depleted oil and gas fields, and deep saline aquifers. Prediction of storage performance will depend on models of the behaviour of $CO_2$ in geological formations; these need to be refined and verified, and methods of monitoring developed and proved. These needs can be met through monitored demonstration and research projects. Current commercial projects that are demonstrating $CO_2$ storage include Sleipner, Weyburn, ORC, and In Salah; research projects include West Pearl Queen, Nagaoka, and Frio. In this paper, some of the monitored injection projects are described. The reservoirs employed for storing $CO_2$, and the associated monitoring techniques, are briefly reviewed. It is argued that small-scale research projects, used to develop techniques and prove models, are complementary to the large-scale monitored injections that will establish the viability of this technique for mitigating climate change.

Monitoring of plant induced electrical signal of broccoli (Brassica oleracea var. italica) under changing light and CO2 conditions (광 및 CO2 변화 조건에서 브로콜리(Brassica oleracea var. italica)의 전기적 신호 모니터링)

  • Park, Jin Hee;Kim, Han-Na
    • Journal of Applied Biological Chemistry
    • /
    • v.64 no.4
    • /
    • pp.351-356
    • /
    • 2021
  • Changing environmental conditions can affect plant growth by influencing water and nutrient transport and photosynthesis. Plant physiological responses under changing environmental conditions can be non-destructively monitored using electrodes as plant induced electrical signal (PIES). Objective of the study was to monitor PIES in response to increased CO2 and decreased photosynthetic photon flux density (PPFD). The PIES increased during day time when transpiration and photosynthesis occurs and monitored CO2 concentration was negatively correlated to the PIES. Enhanced CO2 concentration slightly reduced PIES, but the effect of increased CO2 was limited by light intensity. The effect of reduced PPFD was not appeared immediately because water and nutrient transport was not promptly affected by the light. The study was conducted to evaluate short-term effect of increasing CO2 and decreasing PPFD, hence proline content and chlorophyll fluorescence was not significantly affected by the conditions.

Experimental Study on Estimation of $CO_2$ Saturation by the Electrical Resistivity Monitoring during $CO_2$ Injection for Rock Samples ($CO_2$ 지중저장에 의한 전기비저항 모니터링 및 포화도 예측을 위한 실험 연구)

  • Kim, Jong-Wook;Song, Young-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.388-396
    • /
    • 2010
  • As a part of basic studies on monitoring and saturation estimation of carbon dioxide ($CO_2$) storage using resistivity survey, laboratory experiment has been conducted to measure the change of the electrical resistivity through repeated experiments of supercritical $CO_2$ and brine water injection into homogeneous and heterogeneous sandstones. The $CO_2$ saturation is estimated by using resistivity index based on the resistivity measurements. The experimental results of two types of sandstones show that the effect of pore structure in the rock and the effect of contained clay minerals in the rock can be affected to calculate the $CO_2$ saturation. The result can be useful to evaluate the $CO_2$ saturation based on resistivity survey at the site where $CO_2 sequestrates.

Soil CO2 Monitoring Around Wells Discharging Methane (메탄 유출 관정 주변의 토양 CO2 모니터링)

  • Chae, Gitak;Kim, Chan Yeong;Ju, Gahyeun;Park, Kwon Gyu;Roh, Yul;Lee, Changhyun;Yum, Byoung-Woo;Kim, Gi-Bae
    • Economic and Environmental Geology
    • /
    • v.55 no.4
    • /
    • pp.407-419
    • /
    • 2022
  • Soil(vadose zone) gas compositions were measured for about 3 days to suggest a method for monitoring and interpreting soil gas data collected around wells from which methane(CH4) is outflowing. The vadose zone gas samples were collected within 1 m around two test wells(TB2 and TB3) at Pohang and analyzed for CO2, CH4, N2 and O2 concentrations in situ. CO2 flux was measured beside TB2. In addition, gas samples from well head in TB2 and atmospheric air samples were collected for comparison. Carbon isotopes of CO213CCO2) of samples collected on the last day of the study period were analyzed in the laboratory. The two test wells (TB2 and 3) were 12.7 m apart and only TB3 was cemented to the surface. According to the bio-geochemical process-based interpretation, the relationships between CO2 and O2, N2, and N2/O2 of vadose zone gas were plotted between the lines of CH4 oxidation and CO2 dissolution. In addition, the CH4 concentrations of gas samples from the wellhead of the uncemented well (TB2) were 5.2 times higher than the atmospheric CH4 concentration. High CO2 concentrations (average 1.148%) of vadose zone gas around TB2 seemed to be attributed to the oxidation of CH4. On the other hand, the vadose zone CO2 around the cemented well(TB3) showed a relatively low concentration(0.136%). This difference indicates that the vadose zone gas(including CO2) around the CH4 outflowing well were strongly affected by well completion(cementing). This study result can be used to establish strategies for environmental monitoring of soil around natural gas sites, and can be used to monitor leakage around injection and observation wells for CO2 geological storage. In addition, the method of this study is useful for soil monitoring in natural gas storage and oil-contaminated sites.

Monitoring $CO_2$ injection with cross-hole electrical resistivity tomography (시추공간 전기비저항 토모그래피를 이용한 $CO_2$ 주입 모니터링)

  • Christensen, N.B.;Sherlock, D.;Dodds, K.
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.44-49
    • /
    • 2006
  • In this study, the resolution capabilities of electrical resistivity tomography (ERT) in the monitoring of $CO_2$ injection are investigated. The pole-pole and bipole-bipole electrode configuration types are used between two uncased boreholes straddling the $CO_2$ plume. Forward responses for an initial pre-injection model and three models for subsequent stages of $CO_2$ injection are calculated for the two different electrode configuration types, noise is added and the theoretical data are inverted with both L1- and L2-norm optimisation. The results show that $CO_2$ volumes over a certain threshold can be detected with confidence. The L1-norm proved superior to the L2-norm in most instances. Normalisation of the inverted models with the pre-injection inverse model gives good images of the regions of changing resistivity, and an integrated measure of the total change in resistivity proves to be a valid measure of the total injected volume.

Air Quality Monitoring System Using NDIR-CO$_2$ Sensor for Underground Space based on Wireless Sensor Network (비분산적의선 CO$_2$센서를 이용한 무선 센서 네트워크 기반의 지하 공기질 모니터링 시스템)

  • Kwon, Jong-Won;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.28-38
    • /
    • 2009
  • In this study, a remote air quality monitoring system for underground spaces was developed by using NDIR-based CO$_2$ sensor. And the remote monitoring system based on wireless sensor networks was installed practically on the subway station platform. More than 6.5 million citizens commutate everyday by the Seoul subway transportation that is the most typical public transportation. They concern about air quality with increasing interest on public health or many workers in subway stations or underground shopping centers. Recently, the Korean Ministry of Environment has operated the air quality monitoring system in some subway stations for testing phase. However, it showed many defects which are large-scale, high-cost and maintenance of precision sensors imported from abroad. Therefore this research includes the reliability test and a theoretical study about the inexpensive commercialized CO$_2$ sensor for reliable measurement of air quality which changes rapidly by the surrounding environments. And then we develop the wireless sensor nodes and the gateway applied for remote air quality monitoring. In addition, web server program was realized to manage air quality in the subway platform. This result will be valuable for a basic research for air quality management in underground spaces for future study.