• Title/Summary/Keyword: $COD_s$

Search Result 699, Processing Time 0.027 seconds

Treatment of High Concentration Organic Wastewater with a Sequencing Batch Reactor (SBR) Process Combined with Electro-flotation as a Solids-liquid Separation Method

  • Choi, Younggyun;Park, Minjeong;Park, Mincheol;Kim, Sunghong
    • Environmental Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.395-399
    • /
    • 2014
  • Operation characteristics of the sequencing batch reactor (SBR) process with electro-flotation (EF) as a solid liquid separation method (EF-SBR) were investigated. EF-SBR process showed excellent solid-liquid separation performance which enabled to separate biosolids from liquid phase within 30 min and to extend cyclic reaction time. Although influent organic loading rate was increased stepwise from 5 to 15 g COD/day, food to microorganisms (F/M) ratio could be maintained about 0.3 g COD/g VSS/day in EF-SBR because biomass concentration could be easily controlled at desired level by EF. However, it was impossible to increase biomass concentration at the same level in control SBR (C-SBR) process because solid-liquid separation by gravity settling showed a limitation at higher mixed liquor suspended solids (MLSS) concentration with 60 min of settling time. Total chemical oxygen demand (TCOD) removal efficiency of EF-SBR process was not decreased although influent organic loading rate became 3 times higher than initial value. However, it was seriously deteriorated in C-SBR process after increasing the rate over 10 g COD/day, which was accounted for insufficient organic removal by relatively higher food to microorganisms (F/M) ratio as well as biosolids wash-out by a limitation of gravity sedimentation.

The vertical environmental characteristics in the tidal flat sediments (갯벌의 수직적 환경 특성)

  • 김종구;유선재
    • Journal of Environmental Science International
    • /
    • v.9 no.2
    • /
    • pp.125-129
    • /
    • 2000
  • As one of the fundamental survey to evaluate purification capacity of pollutants at the tidal flat sediments, we studied vertical environmental characteristics in three tidal flat sediments, Chunjangdae, Eueunri and Gyewhado. These are dissmilar to external feature in each other. The results of this study may be summarized as followed; As the results of particle analysis, Eueunri tidal flat fediment located in Keum river estuary consists of 98.98% as silt & clay, Chunjangdae tidal flat sediment located in SeocheonGun consists of 97.99% as sand. And Gyewhado tidal flat sediment located in Saemankeum in Saemankeum area consists area consists of 32.81% as silt & clay and 67.19% as sand. The concentration of organic pollutants(I.L., COD, POC, PON) in Eueunri tidal flat sediment which highly content of silt & clay were 3~4 times higher than others. The concentration of organic pollutants at each layer were slightly increase goes with deepen layer. The linear correlation between I.L. and COD, POC, PON were obtained. Correlation coefficients were in range of 0.821~0.940. Also the correlation between pH and COD, POC, PON were high(>r=0.9). Filteration rate in Chunjangdae tidal flat sediment was 0.01584cm/s as mean value, but the other were almost nothing filtered off.

  • PDF

Applicability of the lenten류s Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant (석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성)

  • Lee, Kyu-Hoon;Kim, Mi-Hwa;Park, Tae-Joo
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.501-508
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton's reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

  • PDF

The Effects of Light Intensity, Inoculum Size, and Cell Immobilisation on the Treatment of Sago Effluent with Rhodopseudomonas palustris Strain B1

  • Ibrahim, Shaliza;Vikineswary, S.;Al-Azad, Sujjat;Chong, L.L.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.5
    • /
    • pp.377-381
    • /
    • 2006
  • A study was carried out to determine a suitable light intensity and inoculum size for the growth of Rhodopseudomonas palustris strain B1. The pollution reduction of sago effluent using free and immobilised R. palustris cells was also evaluated. The growth rate in glutamatemalate medium was highest at 4 klux compared to 2.5 and 3 klux. The optimal inoculum size was 10% (v/v). Both the COD and BOD of the sago effluent were reduced by 67% after three days of treatment. The difference in biomass production or BOD and COD removal with higher inoculum sizes of 15 and 20% was minimal. This could be attributed to limited nutrient availability in the substrate. The use of immobilised cells of R. palustris reduced the pollution load 10% less compared to pollution reduction by free cells. Hence, there was no significant difference in using free or immobilised cells for the treatment of sago effluent.

Treatment of Oily Wastewater with WPO and CWO

  • Han, Mei;Chen, Yihui;He, Fang;Yu, Li
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.1
    • /
    • pp.68-71
    • /
    • 2014
  • Petroleum refining unavoidably generates large volumes of oily wastewater. The environmentally acceptable disposal of oily wastewater is a current challenge to the petroleum industry. Nowadays, more attentions have been focused on the treatment techniques of oily wastewater. Oily wastewater contained highly concentrated and toxic organic compounds. Wet peroxide oxidation (WPO) and catalytic wet oxidation (CWO) were applied to eliminate pollutants to examine the feasibility of the WPO/CWO of oily wastewater. The results indicated that more than 80% chemical oxygen demand (COD) removal from oily wastewater was achieved with CWO. Homogenous catalyst, $NaHCO_3$ and $Na_2CO_3$ and NaOH showed effective removal for pollutants in oily wastewater. Greater than 90% COD removal was achieved with WPO. It was concluded that WPO was a far more effective process for oily wastewater.

Physiochemical Characteristics and Heavy Metal in the Surface Sediments of Marine Shellfish Farming Waters in Anjung Bay, Korea (안정만 패류양식해역의 표층퇴적물의 지화학적특성과 중금속 함량)

  • Jeong, Woo-Geon;Cho, Sang-Man;Lee, Sang-Jun
    • The Korean Journal of Malacology
    • /
    • v.30 no.4
    • /
    • pp.421-428
    • /
    • 2014
  • Total 20 surface sediments were collected in Anjung bay to investigate the physicochemical environment and heavy metal contents. The physicochemical investigation ranged from 6.41% to 11.68% (average $9.52{\pm}1.28%$) for ignition loss (IL), from 17.99 mg/g to 43.84 mg/g (average $27.53{\pm}6.39mg/g$) for chemical oxygen demand (COD), and from 0.05 mg/g to 0.61 mg/g (average $0.17{\pm}0.14mg/g$) for acid volatile sulfide (AVS) with significant correlation between water content (W/C) and COD. A contour of spatial distribution indicated higher organic pollution at the bottom of ascidian, Stylea clava, cultural waters. Most of metals contents was not exceeded the NOAA's effect range-low (ERL). Estimated enrichment factor (EF) ranging 0.96-1.12 indicated that the sediment environment of the studied waters was relatively pristine from heavy metal pollution in spite of increased vessel traffics, so far.

Remediation of Water Quality Using Up-Flow Circulation Apparatus(UFCA) in a Reservoir (용승순환장치를 이용한 호소의 수질개선에 관한 연구)

  • Kang, Chang-Min;Chung, Seon-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.255-260
    • /
    • 2008
  • This study was conducted to analyse the effects of the UFCA for treating polluted water in a reservoir. The UFCA mixes water by circulation of surface and bottom water layers. The circulation supplies oxygen to bottom of the reservoir, resulting in water quality improvement. With a UFCA in use, we surveyed the changes of temperature, pH, transparency, depth, conductivity, DO, COD, BOD, T-N, T-P and Chlorophyll-a for 7 months from Feb. to Aug. in 2004 in our experimental reservoir. There was little difference in the surface and bottom temperatures of the reservoir because of water mixing by the UFCA. However, pH was changed from 7 to 9. The transparency of water was about 80 cm through the all periods. Conductivity was $150\;{\mu}S/cm$ in early Feb., but increased to $270\;{\mu}S/cm$ in early March. Little change was seen in DO with depth, but it was maintained above 6 mg/l in June and July. BOD increased from 2.1 to 12.2 mg/l. The study reservoir did not undergo any eutrophication during the period of our experiment, but the comparison reservoir had an algae-bloom. The COD in the experimental reservoir increased from 5.4 to 14.5 mg/l. The COD concentration of the experimental reservoir was higher than comparison reservoir at the beginning of the study but in August this situation was reversed. SS concentration increased from 13.5 to 23.5 mg/l in Feb., but it fell from between 8.5 to 11.2 mg/l in July. T-N was increased from 1.3 to 4.9 mg/l. It increased up to 3 times in the rainy season as compared to other components. However the comparison reservoir increased up to 40 times higher than the experimental reservoir in the same period. T-P increased from 0.04 to 0.17 mg/l. The ratio of T-N to T-P increased from 20:1 to 40:1 which means that T-P was a growth limiting factor for algae and aquatic plants. Chlorophyll-a increased from 20 to 120 mg/l, and its concentration was correlated with T-P, such that Chlorophyl-a concentration increased with increased of T-P concentration. The concentrations of COD, T-N, T-P and other parameters were higher in the experimental reservoir than in the comparison reservoir but this situation was reversed in July, when the most severe eutophication occurred. The results show that overall the experimental reservoir was greatly remedied by UFCA. The UFCA accelerated the degradation of aquatic organic materials through effective supply of air with up-flow and circulation of water. We conclude that the UFCA can be very effective in aspect of the remediation of water quality incontaminated reservoirs and lakes.

수질 장기관측자료를 활용한 우리나라의 지하수 수질변동 특성

  • 김규범;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.94-96
    • /
    • 2003
  • Since 1995, MOCT(Ministry of Construction and Transportation) and KOWACO(Korea Water Resources Corporation) have established the National Groundwater Monitoring Network in South Korea and also MOE(Ministry of Environment) has operated Groundwater Quality Monitoring network. Until 2001, 202 monitoring stations by MOCT and 780 monitoring wells by MOE have been constructed, measured groundwater level and analyzed water samples. Groundwater quality analysis has been conducted two times a year during last 6 years for all monitoring wells. The quality data has about 15 components including pH, COD, Count of Coliform group, and etc.. Trend analysis has been peformed for 6 components(Coliform, pH, COD, NO$_3$-N, Cl and EC) of water quality which are analyzed more than 7 times for total monitoring wells. Two test methods have been used ; Sen's test and Mann-Kendall test. These trend tests have been done at the 0.05 significance level. By the result of Sen's test, Count of Coliform group has either upward or downward trends at 4.3 percent of the monitoring points. pH does at 5.6 percent, COD does at 8.6 percent, Nitrate-Nitrogen does at 13.2 percent, Chloride does at 13.4 percent, and. EC does at 11.6 percent of the monitoring points. The exact causes of the groundwater quality trends are difficult to specify. Notable downward trends in nitrate at many monitoring points may be the result of reduction on some contamination sources. Potential causes include diminished agricultural areas, improvements in sewage treatment and a decrease in atmospheric deposition. Increase in chloride at many monitoring points may be the result of increased non-point source pollution such as road salting and runoff from sprawling paved developments and suburbs.

  • PDF

A Study on Membrane Fouling by COD fraction of Influent in Submerged MBR (침지식 MBR을 이용한 유입수의 COD fraction에 따른 막오염 특성 연구)

  • Li, Sang-Jeong;Joo, Jae-Young;Bae, Yoon-Sun;Jung, In-Ho;Lee, Hae-Goon;Jeong, Chang-Hwa;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.681-689
    • /
    • 2011
  • Submerged membrane bio-reactor (SMBR) has several advantages such as high MLSS, long SRT, and low F/M ratio at wastewater treatment. So, this has widely applied over the world and many studies have been conducted. However, membrane fouling remains an inevitable problem. This study was investigated using bench-scale SMBR with three poeration modes. Raw waters were prepared by addition of starch, acetic and fibric acid to recovery water of zeolite. The efficiency of nitrification and COD were very stable as about 95% and 80%, respectively. And critical flux was 128.8L/$m^{2}$/hr. The result of biodegradability test was following values at the each mode : Ss+Xs/$C_{T}$=81.7%, 35.1% and 45.3%, $X_{I}+S_{I}/C_{T}=18.3%$, 64.9% and 54.7%. When particulate matters such as $X_{I}$ and $X_{S}$ in influent are increased, membrane fouling will take place more and more. A relative ratio of filtration resistance to the fouling occurred by the cake layer was increased when increased the portion of $X_{I}$ and polysaccharide. It was thought that the formation of cake layer was promoted due to bond between $X_{I}$ and vicid material s generated from the polysaccharide.

Optimal Conditions for Treatment of Swine Wastewater using Rhodopseudomonas palustris KK14 (Rhodopseudomonas palustris KK14를 이용한 돈분폐수처리의 최적조건 검토)

  • Kim, Han-Soo;Lee, Tae-Kyung;Kim, Hyuk-Il;Cho, Hong-Yon;Yang, Han-Chul
    • Applied Biological Chemistry
    • /
    • v.37 no.4
    • /
    • pp.295-302
    • /
    • 1994
  • For the development of biological wastewater treatment process using photosynthetic bacteria (PSB), photosynthetic sludge process consisted of anaerobic digestion and PSB reactor were designed for the treatment of swine wastewater and the optimal operating conditions in flask-scale were examined. Photosynthetic bacteria from soil, pond, rice field, ditch etc. were isolated in synthetic medium containing high amount of organic acids and finally isolated one strain KK14 which showed the most degradating ability of organic acids was selected for the treatment of swine wastewater. It was identified as Rhodopseudomonas palustris. In the anaerobic digestion stage, the maximum organic acid productivity was obtained at pH 5.0, $37^{\circ}C$, HRT 2 day and under anaerobic standing condition. The optimal operating conditions of PSB reactor for the treatment of swine wastewater were pH 7.0, $30^{\circ}C$ under 4,000 lux illumination, and optimal initial COD loading (kg COD/kg D. C. W of PSB) was 2 (20% v/v seeding) in the main purification stage. Maximum removal rate of COD reached 92% under the above optimal conditions for 5 days.

  • PDF