• Title/Summary/Keyword: $C^2-continuity$

Search Result 103, Processing Time 0.029 seconds

Long-term Results of Stellate Ganglion Block in Patients with Olfactory Dysfunction

  • Moon, Ho Sik;Chon, Jin Young;Lee, Sang Hoon;Ju, Yu Mi;Sung, Choon Ho
    • The Korean Journal of Pain
    • /
    • v.26 no.1
    • /
    • pp.57-61
    • /
    • 2013
  • Background: Olfactory dysfunction, including anosmia and hyposmia is difficult to treat. Although the mechanism is not well known, stellate ganglion block (SGB) is used to treat olfactory dysfunction. There are no prior studies on the long-term effects of SGB on olfactory dysfunction. The purpose of this study was to evaluate the continuity of therapeutic effects and patient satisfaction with SGB treatment. Methods: This was a follow-up study carried out via a telephonic survey. The olfactory function of the patient was evaluated using a visual analog scale (VAS). We checked VAS three times: VAS-I (pre-treatment VAS), VAS-A (post-treatment VAS), and VAS-C (VAS at follow up telephone survey). We divided the subjects into 2 groups according to their responsiveness to SGB: the responsive (R group) and the unresponsive groups (UR group). Patient satisfaction was evaluated using a Likert scale. Results: Out of the 40 subjects, 37 responded to the telephone survey. In the UR group, there was difference in the olfactory function. However, in the R group, there were significant VAS differences; VAS-I was $9.6{\pm}0.7$, VAS-A was $5.1{\pm}4.2$, and VAS-C was $2.7{\pm}$2.7 (P < 0.05). On the Likert scale, patient satisfaction was as follows: grade 1, 17 patients (45.9%); grade 2, 6 patients (16.2%); grade 3, 6 patients (16.2%); and grade 4, 8 patients (21.6%). Conclusions: SGB is a safe, long-lasting, and effective therapeutic modality for olfactory dysfunction treatment.

Formulation Method of a Solid-To-Beam Transitional Finite Element (연속체-보 천이 유한요소의 구성)

  • Park, Woo-Jin;Lim, Jang-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.351-356
    • /
    • 2000
  • Various transition elements are generally used for the effective analysis of a complicated mechanical structure. In this paper, a solid-to-beam transition finite element which connects a continuum element and a $c^1-continuity$ beam element each other is proposed. The shape functions of the transition finite elements, which a 8-noded hexahedral solid element fur 3D analysis and a 4-noded quadrilateral plane element fur 2D analysis are connected to a Euler's beam element, are explicitely formulated. In order to show the effectiveness and convergence characteristics of the proposed transition elements. numerical tests are performed for various examples and their results are compared with those obtained by other methods. As the result of this study. following conclusions are obtained: (1)The proposed transition finite elements show the monotonic convergence characteristics because of having used the compatible displacement folds. (2)As being used the transition element in the finite element analysis, the finite element modelings are more convenient and the analysis results are more accurate because of the formulation characteristies of the Euler's beam element.

  • PDF

An Efficient Spatial Error Concealment Technique Using Adaptive Edge-Oriented Interpolation (적응적 방향성 보간을 이용한 효율적인 공간적 에러 은닉 기법)

  • Park, Sun-Kyu;Kim, Won-Ki;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5C
    • /
    • pp.487-495
    • /
    • 2007
  • When error occurs during the network transmission of the image, the quality of the restored image is very serious. Therefore to maintain the received image quality, the error concealment technique is necessary. This paper presents an efficient spatial error concealment method using adaptive edge-oriented interpolation. It deals with errors on slice level. The proposed method uses boundary matching method having 2-step processes. We divide error block into external and internal region, adaptively restore each region. Because this method use overall as well as local edge characteristics, it preserves edge continuity and texture feature. The proposed technique reduces the complexity and provide better reconstruction quality for damaged images than the previous methods.

On Securing Continuity of Long-Term Observational Eddy Flux Data: Field Intercomparison between Open- and Enclosed-Path Gas Analyzers (장기 관측 에디 플럭스 자료의 연속성 확보에 대하여: 개회로 및 봉폐회로 기체분석기의 야외 상호 비교)

  • Kang, Minseok;Kim, Joon;Yang, Hyunyoung;Lim, Jong-Hwan;Chun, Jung-Hwa;Moon, Minkyu
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.3
    • /
    • pp.135-145
    • /
    • 2019
  • Analysis of a long cycle or a trend of time series data based on a long-term observation would require comparability between data observed in the past and the present. In the present study, we proposed an approach to ensure the compatibility among the instruments used for the long-term observation, which would allow to secure continuity of the data. An open-path gas analyzer (Model LI-7500, LI-COR, Inc., USA) has been used for eddy covariance flux measurement in the Gwangneung deciduous forest for more than 10 years. The open-path gas analyzer was replaced by an enclosed-path gas analyzer (Model EC155, Campbell Scientific, Inc., USA) in July 2015. Before completely replacing the gas analyzer, the carbon dioxide ($CO_2$) and latent heat fluxes were collected using both gas analyzers simultaneously during a five-month period from August to December in 2015. It was found that the $CO_2$ fluxes were not significantly different between the gas analyzers under the condition that the daily mean temperature was higher than $0^{\circ}C$. However, the $CO_2$ flux measured by the open-path gas analyzer was negatively biased (from positive sign, i.e., carbon source, to 0 or negative sign, i.e., carbon neutral or sink) due to the instrument surface heating under the condition that the daily mean temperature was lower than $0^{\circ}C$. Despite applying the frequency response correction associated with tube attenuation of water vapor, the latent heat flux measured by the enclosed-path gas analyzer was on average 9% smaller than that measured by the open-path gas analyzer, which resulted in >20% difference of the sums over the study period. These results indicated that application of the additional air density correction would be needed due to the instrument heat and analysis of the long-term observational flux data would be facilitated by understanding the underestimation tendency of latent heat flux measurements by an enclosed-path gas analyzer.

Determining of Weighting Factor for Two-Point Interpolation Filters (2-점 보간법 필터에서의 가중치 결정)

  • Ha, Mi-Ryeong;Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.3
    • /
    • pp.706-712
    • /
    • 2014
  • This paper describes a determining method of weighting factors for two-point interpolation filters. The interpolation filters is implemented by applying modifying functions to the linear interpolation. Here, there is a problem of determining weights when modifying functions being engaged. The previous method determined the weights by imposing c1-continuity on the interpolation kernels. However, this approach is unable to use the property of individual modifying functions. In this paper, on the basis of spectral analyses of the modifying functions and image signals, we provide a determination method by experimental results. Thus, many experiments are carried out to do so. The results indicate that different weights are required for different modifying functions and also the proposed method outperforms than the previous method.

Surgical Repair of Single Ventricle (Type III C solitus) (단심실 -III C Solitus 형의 수술치험-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.281-288
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF

Surgical Treatment of Left Subclavian Aneurysm -A case report- (Subclavian artery 의 동맥류 -1예 수술 경험-)

  • Lee, Sung Haing;Lee, Sung Koo;Han, Sung Sae;Lee, Khil Rho;Kim, Song Myung
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.245-250
    • /
    • 1976
  • A 33 year-old man was admitted with chief complaints of severe sharp pain on left upper interscapular region and motor weakness of left arm for 9 days. He had a history of blunt trauma over left shoulder about 3 years ago. Physical examination showed a ping pong ball sized mass which was located at the left supraclavicular area and was firm, fixed, and nonpulsatile. No bruit or murmur was obtained over the mass. Ipsilaterally, radial, ulnar, and brachial pulse were very weak and ptosis and anhidrosis were noticed. Neurologic examination revealed moderate or severe weakness of flexion and extension of left elbow, wrist and fingers, and anesthesia of the skin in left C8-T1 dermatome and hypalgesia in left C6-C7 dermatome. Retrograde aortography demonstrated complete obstruction of left subclavian artery. An exploratory operation was performed through the left 4th intercostal space. It was found that the mass was a left subclavian aneurysm of traumatic false type. Proximal and distal ligation of the aneurysm were applied and the sac was partially removed. The continuity of the subclavain artery was established by the use of a 6mm. Dacron graft from the root of the subclavian to the axillary artery. Postoperatively the patient was improved from the circulatory and neurologic disturbances.

  • PDF

Numerical Investigation of Ion and Radical Density Dependence on Electron Density and Temperature in Etching Gas Discharges (식각공정용 가스방전에서 이온 및 활성종 밀도의 전자밀도 및 온도 의존성에 대한 수치해석적 분석)

  • An, Choong-Gi;Park, Min-Hae;Son, Hyung-Min;Shin, Woo-Hyung;Kwon, Deuk-Chul;You, Shin-Jae;Kim, Jung-Hyung;Yoon, Nam-Sik
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.422-429
    • /
    • 2011
  • Dependence of radical and ion density on electron density and temperature is numerically investigated for $Cl_2$/Ar, $CF_4$, $CF_4/O_2$, $CF_4/H_2$, $C_2F_6$, $C_4F_8$ and $SF_6$ discharges which are widely used for etching process. We derived a governing equation set for radical and ion densities as functions of the electron density and temperature, which are easier to measure relatively, from continuity equations by assuming steady state condition. Used rate coefficients of reactions in numerical calculations are directly produced from collisional cross sections or collected from various papers. If the rate coefficients have different values for a same reaction, calculation results were compared with experimental results. Then, we selected rate coefficients which show better agreement with the experimental results.

B-spline Curve Approximation Based on Adaptive Selection of Dominant Points (특징점들의 적응적 선택에 근거한 B-spline 곡선근사)

  • Lee J.H.;Park H.J.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • This paper addresses B-spline curve approximation of a set of ordered points to a specified toterance. The important issue in this problem is to reduce the number of control points while keeping the desired accuracy in the resulting B-spline curve. In this paper we propose a new method for error-bounded B-spline curve approximation based on adaptive selection of dominant points. The method first selects from the given points initial dominant points that govern the overall shape of the point set. It then computes a knot vector using the dominant points and performs B-spline curve fitting to all the given points. If the fitted B-spline curve cannot approximate the points within the tolerance, the method selects more points as dominant points and repeats the curve fitting process. The knots are determined in each step by averaging the parameters of the dominant points. The resulting curve is a piecewise B-spline curve of order (degree+1) p with $C^{(p-2)}$ continuity at each knot. The shape index of a point set is introduced to facilitate the dominant point selection during the iterative curve fitting process. Compared with previous methods for error-bounded B-spline curve approximation, the proposed method requires much less control points to approximate the given point set with the desired shape fidelity. Some experimental results demonstrate its usefulness and quality.

Approximate solutions on the absorption process of an aqueous LiBr falling film : effects of vapor flow (리튬브로마이드 수용액 유하액막의 흡수과정에 대한 근사 해법 : 증기 유동의 영향)

  • Kim, B.J.;Lee, C.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.144-152
    • /
    • 1997
  • Film absorption involves simultaneous heat and mass transfer in the vapor-liquid system. In the present work, the absorption process of water vapor by an aqueous soluton of LiBr flowing inside of the vertical tube was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the heat and mass transfer rate. Particularly the effects of vapor flow conditions on the absorption process were investigated in terms of the vapor Reynolds number. As the vapor Reynolds number increased, the shear stress at the vapor-solution interface also increased. Consequently solution film became thinner at higher vapor flowrate under the co-currentflow condition. Thinner film was capable of higher heat transfer to the wall and leaded to higher absorption rate of the water vapor into the solution film.

  • PDF