• Title/Summary/Keyword: $2{\times}2$ 검증테이블

Search Result 6, Processing Time 0.049 seconds

Enhancing the Satisfaction Value of User Group Using Meteorological Forecast Information: Focused on the Precipitation Forecast (기상예보 정보 사용자 그룹의 만족가치 제고 방안: 강수예보를 중심으로)

  • Kim, In-Gyum;Jung, Jihoon;Kim, Jeong-Yun;Shin, Jinho;Kim, Baek-Jo;Lee, Ki-Kwang
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.382-395
    • /
    • 2013
  • The providers of meteorological information want to know the level of satisfaction of forecast users with their services. To provide better service, meteorological communities of each nation are administering a survey on satisfaction of forecast users. However, most researchers provided these users with simple questionnaires and the respondents had to choose one answer among different satisfaction levels. So, the results of this kind of survey have low explanation power and are difficult to use in developing strategy of forecast service. In this study, instead of cost-loss concept, we applied satisfaction-dissatisfaction concept to the $2{\times}2$ contingency table, which is a useful tool to evaluate value of forecast, and estimated satisfaction value of 24h precipitation forecasts in Shanghai, China and Seoul, Korea. Moreover, not only the individual satisfaction value of forecast but the user group's satisfaction value was evaluated. As for the result, it is effective to enhance forecast accuracy to improve the satisfaction value of deterministic forecast user group, but in the case of probabilistic forecast, it is important to know the level of dissatisfaction of user group and distribution of probability threshold of forecast users. These results can help meteorological communities to search for a solution which can provide better satisfaction value to forecast users.

Verification of skin dose according to the location of tumor in Tomotherapy (토모테라피 시 종양의 위치에 따른 피부선량 검증)

  • Yoon, Bo Reum;Park, Su Yeon;Park, Byoung Suk;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • Purpose : To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. Materials and Methods : In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5mm and 10mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3mm and 5mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. Results : The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5mm and 3mm respectively. If placed 5mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5mm and 3mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2~17.1% whereas if the tumor is 5mm away from the ceiling part, the figure decreased to 2.8~9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment. Conclusion : This study found gaps between planned skin doses and actual doses in the Tomotherapy treatment planning. Especially to the Tomo-cocuh direction, skin doses were found to be larger than the planned doses. Thus, during the treatment of tumors near the Tomo-couch, doses will need to be more accurately calculated and more efforts to verify skin doses will be required as well.

Hardware Design for JBIG2 Huffman Coder (JBIG2 허프만 부호화기의 하드웨어 설계)

  • Park, Kyung-Jun;Ko, Hyung-Hwa
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.2
    • /
    • pp.200-208
    • /
    • 2009
  • JBIG2, as the next generation standard for binary image compression, must be designed in hardware modules for the JBIG2 FAX to be implemented in an embedded equipment. This paper proposes a hardware module of the high-speed Huffman coder for JBIG2. The Huffman coder of JBIG2 uses selectively 15 Huffman tables. As the Huffman coder is designed to use minimal data and have an efficient memory usage, high speed processing is possible. The designed Huffman coder is ported to Virtex-4 FPGA and co-operating with a software modules on the embedded development board using Microblaze core. The designed IP was successfully verified using the simulation function test and hardware-software co-operating test. Experimental results shows the processing time is 10 times faster than that of software only on embedded system, because of hardware design using an efficient memory usage.

  • PDF

The Effect of The Virtual Reality Rehabilitation System on Activities of daily living, cognitive function, self-esteem in Stroke (가상현실재활시스템 적용에 따른 뇌졸중 환자의 일상생활활동, 인지기능, 자아존중감의 개선효과)

  • Kim, Young-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5476-5484
    • /
    • 2015
  • The purpose of this study was to verify the clinical usefulness of the virtual reality rehabilitation system which Academic-Industrial cooperation develop through clinical experiment for recovering the functional abilities in stroke. For this purpose, 24 Stroke(hemorrhage13, infarction11)participated in a clinical experiment. They were randomly assigned to the virtual reality rehabilitation system group(n=13) and conventional rehabilitation training(Activities of daily living, cognition training, motor control) group(n=11). All participant were evaluated with three standardized assessment tools(Functional Independent Measure; FIM, Mini-Mental State Examination for Korean; MMSE-K, Self-esteem scale) before and after the planned intervention sessions. All participant were intensively carried out for 8weeks, 3times a week. The results were as follows. The experimental group showed significant improvements for Activities of daily living, basic cognitive abilities and self-esteem related with life satisfaction after the interventions(p<.05). There were no significant differences between two groups for all assessment tool after interventions. Because of this experimental results, the virtual reality rehabilitation system showed the clinical utility for recovering the function in stroke. Further studies are needed to verify the clinical usefulness on the improvement of various functions in brain injury and dementia.

Development of a High Resolution SPECT Detector with Depth-encoding Capability for Multi-energy Imaging: Monte Carlo Simulation (다중에너지 영상 획득을 위한 Depth-Encoding 고분해능 단일광자단층촬영 검출기 개발: 몬테칼로 시뮬레이션 연구)

  • Beak, Cheol-Ha;Hwang, Ji-Yeon;Lee, Seung-Jae;Chung, Yong-Hyun
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.93-98
    • /
    • 2010
  • The aim of this work was to establish the methodology for event positioning by measuring depth of interaction (DOI) information and to evaluate the system sensitivity and spatial resolution of the new detector for I-125 and Tc-99m imaging. For this purpose, a Monte Carlo simulation tool, DETECT2000 and GATE were used to model the energy deposition and light distribution in the detector and to validate this approach. Our proposed detector module consists of a monolithic CsI(Tl) crystal with dimensions of $50.0{\times}50.0{\times}3.0\;mm^3$. The results of simulation demonstrated that the resolution is less than 1.5 mm for both I-125 and Tc-99m. The main advantage of the proposed detector module is that by using 3 mm thick CsI(Tl) with maximum-likelihood position-estimation (MLPE) method, high resolution I-125 imaging and high sensitivity Tc-99m imaging are possible. In this paper, we proved that our new detector to be a reliable design as a detector for a multi-energy SPECT.

Verify Image-Guided Shifts for 6DoF Couch using Yonsei Cancer Center QA Set (Yonsei Cancer Center QA Set을 이용한 6DoF Couch의 이동 정확성 검증)

  • Jung, Dongmin;Park, Hyokuk;Yoon, Jongwon;Lee, Sangkyu;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.7-18
    • /
    • 2017
  • Purpose: A QA Set was established to verify the movement accuracy of image-guided 6DoF Couch and to evaluate its usefulness. Materials and Methods: Two sets of linear accelerators equipped with 6DoF Couch and CBCT were used. Using the established QA Set, each CBCT image was obtained over 15 times through the Penta-Guide Phantom installed with off-set shift values along six translational (Translation; TX, TY, TZ) and rotational (Rotation, Pitch; RX, Roll; RY, Yaw; RZ) directions. Using this method, we compared the reference image and the registration image, and we analyzed the error calculated by measuring the positional accuracy of the modified 6DoF Couch. Results: The Air Cavity corresponding to the Pixel of the reference image and the registration image were all contained between 30 and 66, and the revealing high registration accuracy. Error between the modified off-set value of 6DoF Couch and the measured value along translational directions were $0.25{\pm}0.18mm$ in the TX direction, $0.25{\pm}0.25mm$ in the TY direction, and $0.36{\pm}0.2mm$ in the TZ direction. Misalignments along the rotational axis were $0.18{\pm}0.08^{\circ}$ in the RX direction, $0.26{\pm}0.09^{\circ}$ in the RY direction, and $0.11{\pm}0.08^{\circ}$ in the RZ direction, it was corrected precisely for any value. Conclusion: Using the YCC QA Set, we were able to verify the error of 6DoF Couch along both the translational and rotational directions in a very simple method. This system would be useful in performing Daily IGRT QA of 6DoF Couch.

  • PDF