• Title/Summary/Keyword: $2{\times}$ magnification

Search Result 134, Processing Time 0.027 seconds

Bio-accumulation of 210Pb and 210Po within the Trophic Level of Phytoplankton-Zooplankton-Anchovy-Mackerel in the Coastal Water of the Jeju Island, Korea (제주도 근해 식물플랑크톤-동물플랑크톤-멸치-고등어 영양단계에서 210Pb과 210Po의 생물농축)

  • Cho, Boeun;Kim, Suk Hyun
    • Ocean and Polar Research
    • /
    • v.38 no.2
    • /
    • pp.139-148
    • /
    • 2016
  • The activity concentrations of $^{210}Po$ and $^{210}Pb$ within phytoplankton-zooplankton-anchovy-mackerel in the coastal water of the Jeju Island were determined to understand their distribution and bio-accumulation along the trophic level. In the surface water, the total activity concentrations of $^{210}Po$ and $^{210}Pb$ were $0.83{\pm}0.004mBq\;kg^{-1}$ and $1.27{\pm}0.03mBq\;kg^{-1}$. And the dissolved activity concentration of $^{210}Po$ and $^{210}Pb$ were $0.75{\pm}0.06mBq\;kg^{-1}$ and $1.22{\pm}0.09mBq\;kg^{-1}$ respectively. In the phytoplankton, the concentration factor (CF) of $^{210}Po$ and $^{210}Pb$ were $1.5{\times}10^5$ and $2.6{\times}10^4$ shows $^{210}Po$ is 5 times higher compared to $^{210}Pb$. The similar CF factor in the zooplankton of $^{210}Po$ was derived as $1.4{\times}10^5$. The CF of $^{210}Po$ in anchovy was increased twice compared to that in plankton. This is the evidence that there is $^{210}Po$ bio-magnification in the trophic level of plankton-anchovy. However the $^{210}Po$ activity concentration in the muscle tissue of mackerel was one-hundred times lower than that in anchovy. This reflects that in the trophic level of anchovy-mackerel, the bio-accumulation of $^{210}Po$ is decreased. The activity concentrations of $^{210}Po$ in the internal organs of anchovy and mackerel were 8 to 38 times higher than those in muscle tissues. In phytoplankton-zooplankton-anchovy, the CF of $^{210}Pb$ was decreased five times along the trophic level in order. In anchovy-mackerel it was decreased by 30-70%.

Optical Design of a Zoom Eyepiece (Zoom접안경에 대한 광설계)

  • 임천석;이상수;박충선;김재순
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.356-363
    • /
    • 1994
  • By Gaussian optics, a zoom eyepiece is analyzed, which has the diameter of exit pupil 0.5 em, eyerelief 1 em, and angular magnification $M_a=7~15$. The initial design is based on this analysis. Telescope objective which was previously designed has focal length($(f_u')$ 21.0 em, and its clear aperture is 6.2 em. Zoom telescope has half field angle $\beta=1.5^{\circ}$ at the entrance pupil and at exit pupil it is $\beta'=1.5^{\circ}\times(7~15)=10.5^{\circ}~22.5^{\circ}$. Zoom eyepiece consists of three groups, of which each one satisfies the Seidel 3,d order aplanatization. Final design is obtained by optimization for the finite ray aberration, and the zoom eyepiece is assessed on the basis of the resolution of eyes.f eyes.

  • PDF

Flexural strength of indirect composite resin with different polymerization conditions (중합 조건에 따른 간접복합레진의 굴곡강도)

  • Geum, Young-Hee;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.333-341
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the flexural strength of indirect composite resins with different polymerization conditions. Methods: Ten specimens ($2mm{\times}2mm{\times}25mm$) of each composite resins (Tescera (T), Gradia (S) and Sinfony (S)) were fabricated by two polymerization methods : manufacturers's and light heat pressure. Composite resins polymerized by manufacturers's method and light heat pressure served as control (TS, GS and SS) and experimental groups (TE, GE and SE), respectively. The composite resins were tested for flexural strength and the surface of composite resins were observed with scanning electron microscope (SEM) under X1,000 magnification. Results: The flexural strength values of cured composite resin decreased in the following order: TE (195.4MPa), TS (179.8MPa), GE (169.9MPa), SE (137.7MPa), SS (111.1MPa) and GS (100.9MPa) groups. Conclusion: The flexural strength values between the control and the experimental groups were not significantly different although experimental groups showed higher flexural strength values than control groups.

THE SEALING ABILITY OF OBTURATION TECHNIQUES IN OPEN APEX (개방 근첨 치아의 근관 충전방법에 따른 치근단 폐쇄효과에 관한 연구)

  • So, Hyun;Choi, Ho-Young;Choi, Kyung-Kyu;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.435-445
    • /
    • 2000
  • The purpose of this study was to compare the leakage of four different obturation techniques in conjunction with immediate apical barrier of ${\beta}$-tricalcium phosphate(TCP) in teeth with open apex. Eighty single-rooted human premolar teeth were prepared and sectioned horizontally, so maximum diameter in apex was 4mm. Apical defects that were similar to open apex, were created with #1/2 round bur and SF104R bur. The apical foramen were opened to a size 80 file extended 3mm beyond the apex. The teeth were placed into the oasis block soaked saline to simulate periapical tissue often associated with pulpless teeth and received apical barriers consisting of TCP followed by obturation using lateral condensation technique, vertical condensation technique, continuous wave technique and thermoplasticized gutta-percha injection technique. Two unobturated teeth served as positive and negative controls. Teeth were immersed in resorcinol-formaldehyde resin for S days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then sectioned horizontally at 1.5mm(level 1), 2.5mm(level 2) and 3.5mm(level 3) from the apex, and examined under a stereomicroscope at ${\times}40$ magnification. The photographs were taken at ${\times}40$ magnification of the filling in each level and scanned. The leakage length in tooth/resin interface was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the leakage length of canal wall infiltrated with resin to the total length of the canal and was analyzed statistically(One-way ANOVA and Scheffe test). The result were as follows : 1. At the level 1, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), and the most leakage in the continuous wave technique group(group 3). There was statistically significant difference between the thermoplasticized gutta-percha injection technique group and the continuous wave technique group(p<0.05). 3. At the level 3, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there were no statistically significant differences between other groups(p>0.05). These results suggest that thermoplasticized gutta-percha injection technique which had 1mm apical gutta-percha matrix after the formation of TCP apical barrier, can demonstrate favorable apical sealing.

  • PDF

Development of the Imaging Optical System for the 545 nm Fluorescent Plate of X-ray (X선용 545 nm 형광판 결상광학계 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • To develop an imaging optical system for the 545 nm fluorescent plate of X-ray. Methods: We designed and manufactured a new imaging optical system for the 545 nm fluorescent plate of X-ray by Sigma 2000 program after deciding the design comparison standards referred to Canon CX2-70 model. Results: The characteristics of the new imaging optical system for the 545 nm fluorescent plate of X-ray have the magnification of -0.225x, the image field size of $90mm{\times}90mm$, and the 0.033 mm resolution line width at the 30% MTF value criterion. These mean that the new model has a capability of deciphering for the more large screen and the resolution of deciphering is superior to that of Canon CX2-70 model. Also the image side NA (-0.196) of the new model is about $\sqrt{2}$ times than that (-0.139) of CX2-70 and the object side NA (0.044) of the new model is about 2 times than that (0.022) of CX2-70. These mean that the sensitivity of the film in the new design model is able to be increased to about 4 times and there is the possibility of reducing the bombed time of X-ray to 1/4 times. Conclusions: We could design and manufacture the imaging optical system for the 545 nm fluorescent plate of X-ray having the possibility of reducing the bombed time of X-ray to 1/4 times in comparision to Canon CX2-70 model, the characteristics of which have the image field size of $90mm{\times}90mm$ and the MTF of 30% or more at 15 lines/mm criterion.

  • PDF

Super-Resolution Transmission Electron Microscope Image of Nanomaterials Using Deep Learning (딥러닝을 이용한 나노소재 투과전자 현미경의 초해상 이미지 획득)

  • Nam, Chunghee
    • Korean Journal of Materials Research
    • /
    • v.32 no.8
    • /
    • pp.345-353
    • /
    • 2022
  • In this study, using deep learning, super-resolution images of transmission electron microscope (TEM) images were generated for nanomaterial analysis. 1169 paired images with 256 × 256 pixels (high resolution: HR) from TEM measurements and 32 × 32 pixels (low resolution: LR) produced using the python module openCV were trained with deep learning models. The TEM images were related to DyVO4 nanomaterials synthesized by hydrothermal methods. Mean-absolute-error (MAE), peak-signal-to-noise-ratio (PSNR), and structural similarity (SSIM) were used as metrics to evaluate the performance of the models. First, a super-resolution image (SR) was obtained using the traditional interpolation method used in computer vision. In the SR image at low magnification, the shape of the nanomaterial improved. However, the SR images at medium and high magnification failed to show the characteristics of the lattice of the nanomaterials. Second, to obtain a SR image, the deep learning model includes a residual network which reduces the loss of spatial information in the convolutional process of obtaining a feature map. In the process of optimizing the deep learning model, it was confirmed that the performance of the model improved as the number of data increased. In addition, by optimizing the deep learning model using the loss function, including MAE and SSIM at the same time, improved results of the nanomaterial lattice in SR images were achieved at medium and high magnifications. The final proposed deep learning model used four residual blocks to obtain the characteristic map of the low-resolution image, and the super-resolution image was completed using Upsampling2D and the residual block three times.

An Analysis of Performance Error of Roundness Measuring Instrument -by phase different method- (眞圓度 測定器의 誤差特性에 대한 解析 -위상차법-)

  • 한응교;허문석;박익근
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.31-37
    • /
    • 1988
  • A phase different method to evaluate the instrument error of roundness measuring instrument and the form error of specimens for the calibration of the instrument is used. An instrument with a rotary table supported by an air bearing was calibrated by using the standard balls as a standard. The calibration was carried out repeatedly by setting the same ball in 12 phase angles(per 30.deg.) on the table and by recording their roundness errors with a magnification of 100,000 times. As a result of data analysis of all the observations, readout at each of 144 orientations(per 2.5.deg.) from recorded data file, the error of performance of the instrument and the specimens are separated. In the particular instrument used in the present experiment, the error of the instrument was determined with the accuracy of 0.0164 (.mu.m) and the form error of the specimens was determined with the accuracy of 0.0264,0.0172(.mu.m), respectively. If the instrument was calibrated by using the above specimens, then the accuracy of the measurement of roundness error can be improved to about 0.017 (.mu.m).

  • PDF

Design & Manufacturing of Surgical Telescope with 3.5 times magnification. (배율 3.5X 의료용 망원경의 설계 및 제작)

  • 이호찬;김재순;이재형;이하덕
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.112-113
    • /
    • 2003
  • 일반, 혹은 신경외과 의사가 작은 수술부위의 구멍을 통해 미세한 혈관수술 등을 할 때, 혹은 치과의사가 환자의 입을 통해서 입 속을 치료할 때, 수술 혹은 치료를 하는 대상의 크기는 굵은 혈관의 경우 지름이 30~40$\mu\textrm{m}$, 치아 속 신경의 역시 굵은 경우에 2.8$\mu$m 에 지나지 않는다. 그러나 일반적인 눈의 분해능은 1분인데, 이는 40cm의 거리에 있는 0.06mm 크기의 물체(9lp/mm)를 구분하는 능력이다. 특별한 광학장비 없이 물체에 가까이 감으로써 시력을 향상시킬 수는 있지만 단순히 가까이 다가가는 것만으로는 수술과 같은 섬세한 임상작업을 하는데는 제한이 많고, 특히 작은 구멍이나 좁은 관을 통해 가까운 물체를 볼 때는 양안 시차의 불일치(stereofocusing) 문제가 발생한다. (중략)

  • PDF

Four Spherical Mirror Stepper Optics for Deep UV Micro-Lithography (Deep UV 마이크로 리소그라피용 Stepper를 위한 4구면 반사경계)

  • 조영민;이상수;박성찬
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.186-192
    • /
    • 1991
  • For the micro-lithography using a excimer laser beam $(\lambda\leq0.248$\mu\textrm{m})$. a mirror system consisting of four spherical surfaces with reductlon magnification 5X is designed. Initially the aplanat, flat field and the distortion free condition of the system are analytically investigated within Seidel 3rd order aberrations. And the computer-aided optimization technique has been employed for the further improved performance of the system. The final system has N.A. of 0.15 and image field diameter 3.3 mm, and has the diffraction-limited performance for KrF eximer laser beam.

  • PDF

An Analysis of Performance Error of High Precision Measuring Instrument (진원도 측정기의 오차특성에 관한 연구)

  • 한응교;노병옥;허민석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.862-874
    • /
    • 1989
  • A phase evil method and spectrum analysis were instrument error which is originated from measurement system and the form error of standard specimens. An instrument with a rotating table supported by an air bearing is calibrated using standard specimens. The phase of standard specimens was measured 12 times on the rotating table with rotating 30 in turn and its measurement magnification was set by 100000 times. As a result of data analysis of all the observations, read out at each of 144 orientations(per 2.5) from recorded datafiles, the error of the performance of the instrument and those of the standard specimens are evaluated and a systematic deviation of the instrument is determined. In the particular instrument used in the present experiment, the deviation of the instrument is determined with the accuracy of 15nm and those of standard specimens with the accuracy of 23, 13 n, respectively. The reproducibility of the instrument is investigated, too. If the instrument is calibrated by using the above standard specimens, then the accuracy of the measurement of roundness error can be improved to about 15nm.