• Title/Summary/Keyword: $2{\times}$ 배율

Search Result 60, Processing Time 0.026 seconds

Development of Dot Sight with 2× Magnification (2× 배율 도트사이트 장치의 개발)

  • Lee, Dong-Hee;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.435-440
    • /
    • 2012
  • Purpose: The purpose of this study is developing the dot sight with a $2{\times}$ magnification. Methods: To magnify the target when we see the far through the non-magnified dot sight, we develop the new optical device which is detachable to the non-magnified dot sight. A new optical device is designed to facilitate the transition of an existing non-magnification ($1{\times}$) dot sight to the $2{\times}$ magnification dot sight. Results: We could design and fabricate the $2{\times}$ afocal optical system which is detachable to the non-magnified dot sight and be composed by a pair of doublet. When the system developed in this study was used, we could aim the external target by twice magnification, so we could further improve the accuracy of aim. Conclusions: We could design and manufacture the $2{\times}$ afocal optical system which can be detachable to the non-magnified dot sight. With the results, we could aim the external target by twice magnification, so we could further improve the accuracy of aim.

Classification of Breast Tumor Cell Tissue Section Images (유방 종양 세포 조직 영상의 분류)

  • 황해길;최현주;윤혜경;남상희;최흥국
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.4
    • /
    • pp.22-30
    • /
    • 2001
  • In this paper we propose three classification algorithms to classify breast tumors that occur in duct into Benign, DCIS(ductal carcinoma in situ) NOS(invasive ductal carcinoma) The general approach for a creating classifier is composed of 2 steps: feature extraction and classification Above all feature extraction for a good classifier is very significance, because the classification performance depends on the extracted features, Therefore in the feature extraction step, we extracted morphology features describing the size of nuclei and texture features The internal structures of the tumor are reflected from wavelet transformed images with 10$\times$ and 40$\times$ magnification. Pariticulary to find the correlation between correct classification rates and wavelet depths we applied 1, 2, 3 and 4-level wavelet transforms to the images and extracted texture feature from the transformed images The morphology features used are area, perimeter, width of X axis width of Y axis and circularity The texture features used are entropy energy contrast and homogeneity. In the classification step, we created three classifiers from each of extracted features using discriminant analysis The first classifier was made by morphology features. The second and the third classifiers were made by texture features of wavelet transformed images with 10$\times$ and 40$\times$ magnification. Finally we analyzed and compared the correct classification rate of the three classifiers. In this study, we found that the best classifier was made by texture features of 3-level wavelet transformed images.

  • PDF

정액의 희석배율 및 주입 정자수가 닭의 수정능력에 미치는 영향

  • 김학규;나재천;최철환;장병귀;상병돈;이상진
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2002.11a
    • /
    • pp.116-117
    • /
    • 2002
  • This study was conducted to investigate the effects of dilution rate and stored time of semen at 5, 25 and 35$^{\circ}C$ on mobility in liquid rooster semen. At 5$^{\circ}C$ cold temperature, no significant difference were found in sperm mobilities on dilution rate and stored time among treatments stored at 5$^{\circ}C$. Sperm mobility for the conservation of 1 hours at 25$^{\circ}C$ and 3 hours at 35$^{\circ}C$ were significantly higher for 1:2 and 1:3 dilution rate(semen: diluent) groups than for 1:1 dilution rate group(P〈0.05), In Fertility results after artificial insemination with different number of sperm per dole, fertilization rate of liquid rooster semen diluted with skim milk-glucose solution were 90.67, 94.00, 96.00, and 98.67% for 0.2${\times}$10$\^$8//dose, 0.4${\times}$10$\^$8//dose, 1.0${\times}$10$\^$8//dose, and 2.0${\times}$10$\^$8//dose groups, respectively. To have more than 90% fertility, 0.2${\times}$10$\^$8/ sperm per dose for the artificial insemination (AI) could be used, And to have more 94% fertility, 0.4${\times}$10$\^$8/ sperm per dose AI could be used practically.

Design and fabrication of a zoom optics having 20 magnification range for mid-IR(3.7-4.8$\mu$m) FLIR system (3.7-4.8$\mu$m 파장대역 FLIR 시스템을 위한 20:1 줌 렌즈 광학계 설계 및 제작)

  • 김현숙;김창우;홍석민
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.462-467
    • /
    • 1999
  • This paper describes the design and fabrication of mid-IR $(3.7-4.8{\mu}m)$ zoom optics which is used for FUR (Forward Looking Infra-Red) system with 320 $\times$ 240 focal plane arrays. The zoom optics has 20 magnification range and maximun 40$^{\circ}$$\times$30$^{\circ}$ of super wide field of view. The locus of zoom is almost linear, which gives easy access of mechanical and electro-mechanical design. The on-axis MTF of zoom optics has been measured and it shows diffraction limited optical performance. For example, it gives 0.692 at 24 cycles/mm at highest magnification, and 7.6 cycles/mradof resolving power is achieved with the operation of attached micro-scanning system.system.

  • PDF

Design of Two Zoom Infrared Camels using Noise Uniformity Correction by Shutter Lens (셔터렌즈에 의한 검출기 불균일 보정을 적용한 이중배율 적외선 카메라 설계)

  • Ahn, Gyou-Bong;Kim, Seo-Hyun;Jung, Jae-Chul;Jo, Mun-Shin;Kim, Chang-Woo;Kim, Hyun-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.135-141
    • /
    • 2007
  • This paper describes the design technology for a third generation thermal imaging system, which is more compact than before, using a $320\times240$ mid-IR focal plane detector. The third generation non-scanning thermal imaging system was constructed as a compact thermal imaging module as a reconnaissance, surveillance and navigation sensor for helicopter and infantry vehicles in the $1980's\sim1990's$ and now, we designed a new compact infrared camera and studied a new type of non-uniformity correction lens fer this camera.

Optical Design of a Zoom Eyepiece (Zoom접안경에 대한 광설계)

  • 임천석;이상수;박충선;김재순
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.356-363
    • /
    • 1994
  • By Gaussian optics, a zoom eyepiece is analyzed, which has the diameter of exit pupil 0.5 em, eyerelief 1 em, and angular magnification $M_a=7~15$. The initial design is based on this analysis. Telescope objective which was previously designed has focal length($(f_u')$ 21.0 em, and its clear aperture is 6.2 em. Zoom telescope has half field angle $\beta=1.5^{\circ}$ at the entrance pupil and at exit pupil it is $\beta'=1.5^{\circ}\times(7~15)=10.5^{\circ}~22.5^{\circ}$. Zoom eyepiece consists of three groups, of which each one satisfies the Seidel 3,d order aplanatization. Final design is obtained by optimization for the finite ray aberration, and the zoom eyepiece is assessed on the basis of the resolution of eyes.f eyes.

  • PDF

Development of Scope with Abbe-König Prism (아베-코닉 프리즘을 이용한 스코프 개발)

  • Lee, Dong-Hee;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.509-517
    • /
    • 2013
  • Purpose: The purpose of this study is developing the 2.6 ${\times}$ optical scope with a Abbe-K$\ddot{o}$nig prism. Methods: First, considering the size of the effective aperture and the focal length of the objective lens, we designed an Abbe-K$\ddot{o}$nig prism. Next, we calculated the optical and geometric distances of Abbe-K$\ddot{o}$nig prism designed in this way. After allocating the focal length of the objective lens and the eyepiece lens so as to satisfy the magnification and optical effective distance of the entire system by using this calculation result, we completed the entire system by optimizing this optical system. Results: We were able to complete the optical scope of about 2.6 ${\times}$ magnification by designing an objective lens with a focal length of 63.13 mm which was composed of two pieces, an eyepiece with a focal length of 24.3 mm which was composed of four pieces, and an Abbe-K$\ddot{o}$nig prism with a face length 11.5 mm. Conclusions: We designed and fabricated an optical scope with 2.6 ${\times}$ magnification employing an Abbe-K$\ddot{o}$nig prism. Then, this system became the compacted optical system with a barrel diameter of 31 mm, characterized by an effective aperture of 12.0 mm and an effective optical barrel length of 103 mm and a resolution of 200 cycles/rad at 50% MTF criterion within the half viewing field angle of $6.42^{\circ}$.

Structure of $NiSi_2$(111) Surface : An Atomic View ($NiSi_2$(111) 표면의 구조 : 원자적 배율)

  • Kuk, Y.;Hasegawa, Y.;Tokumoto, H.
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.1
    • /
    • pp.23-27
    • /
    • 1993
  • NiSi2(111)을 Si(111) 표면 위에 증착하여 그 구조를 STM으로 연구하였다. 실리사이드는 그 표면이 (1$\times$1)의 구조를 띠고 여분의 trimer를 흡착 분자 구조로 가짐을 관찰하였다. 이 trimer로부터 실리사이드의 두 가지 구조 A, B를 구별할 수 있었다. 표면에 관착된 결함으로부터 표면구조는 내부와 같음을 보였다.

  • PDF

Enlargement of Field-of-View (FOV) of the CCD Camera by the Current Adjustment of the Projection Lens System in the KBSI-HVEM (KBSI-HVEM 투사렌즈 전류제어에 의한 CCD Camera의 Field of View(FOV) 확장)

  • Kim, Young-Min;Shim, Hyo-Sik;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.35 no.4
    • /
    • pp.98-104
    • /
    • 2005
  • A FOV (field-of-view) of the HV-MSC (high voltage multi-scan CCD, $1024{\times}1024$ pixels) camera mounted in the post-column HV-GIF (high voltage gatan image filter) has been drastically enlarged by the projection lens current adjustment. An imaging area of the HV-MSC camera obtained at the lowest magnification (2,000x) is $112{\mu}m^2$ which corresponds to the recording area of the film at the magnification of 8,800x, while the achievable recording area is only $0.43{\mu}m^2$ at the same magnification without this technique. Ignoring the image distortion of less than 5%, we have designed an on-site reference graph to estimate projection lens currents for microscope magnifications above 8,800x, where the recording area on the HVMSC is same as that on the film.

Advanced LWIR Thermal Imaging Sight Design (원적외선 2세대 열상조준경의 설계)

  • Hong, Seok-Min;Kim, Hyun-Sook;Park, Yong-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.209-216
    • /
    • 2005
  • A new second generation advanced thermal imager, which can be used for battle tank sight has been developed by ADD. This system uses a $480\times6$ TDI HgCdTe detector, operating in the $7.7-10.3{\mu}m$ wavelength made by Sofradir. The IR optics has dual field of views such as $2.67\times2^{\circ}$ in NFOV and $10\times7.5^{\circ}$ in WFOV. And also, this optics is used for athermalization of the system. It is certain that our sensor can be used in wide temperature range without any degradation of the system performance. The scanning system to be able to display 470,000 pixels is developed so that the pixel number is greatly increased comparing with the first generation thermal imaging system. In order to correct non-uniformity of detector arrays, the two point correction method has been developed by using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we have proposed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained the highest quality thermal image. The MRTD of the LWIR thermal sight shows good results below 0.05K at spatial frequency 2 cycles/mrad at the narrow field of view.