• Title/Summary/Keyword: $1^{st}$-order measurement

Search Result 93, Processing Time 0.024 seconds

A STUDY ON THE MEASUREMENT OF DENIAL AGE (Dental Age측정에 관한 연구)

  • Park, Soon-Seo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.21 no.2 s.34
    • /
    • pp.341-351
    • /
    • 1991
  • Dental maturity is one of the index of physiological maturity indicators. To investigate the relationship between dental maturity and chronological age, the author took the orthopantomograms of 984 students, aged 7 through 17 years, having normal occlusion. The orthopantomograms were examined and calcification degree of each tooth on the left side was rated according to the method described by Demirjian. On the basis of findings of this study, the following results were obtained. 1. The root completion periods of mandibular permanent teeth were as follows; Central Incisor M $8.32{\pm}1.03\;years$ F $7.96{\pm}1.04\;years$ Lateral Incisor M $9.40{\pm}1.30\;years$ F $9.01{\pm}0.90\;years$ Canine M $12.81{\pm}1.24\;years$ F $11.42{\pm}0.94\;years$ 1st Premolar M $12.76{\pm}1.74\;years$ F $12.19{\pm}1.33\;years$ 2nd Premolar M $13.31{\pm}1.88\;years$ F $12.88{\pm}1.49\;years$ 1st Molar M $9.60{\pm}1.69\;years$ F $9.30{\pm}1.16\;years$ 2nd Molar M $14.38{\pm}1.73\;years$ F $13.96{\pm}1.63\;years$ 2. Sexual differences in same age group at given calcification stage were not significant statistically. 3. The developmental order in mandibular permanent teeth was as follows; a) central incisor, b) lateral incisor, c) 1st molar, d) canine and 1st premolar, e) 2nd premolar, f) 2nd molar.

  • PDF

The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area (도심지 발파공사장의 발파진동 특성)

  • 이연수;장서일
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.521-526
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, Z(perpendicularity) axis was the highest value in vibration level, but vertical axis was the highest value at 25m point and longitudinal axis was the highest value at 50m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, 2 axis was the highest value in vibration level, but in vibration velocity transverse axis was the highest value at ground, was vertical axis at 1st floor, was longitudinal axis at 3rd floor and was vertical and longitudinal axis at 5th floor. The vibration level and the vibration velocity of 50m point showed higher correlation value than 25m point at the ground, but those of 25m point showed higher correlation value than 50m point at the apartment.

  • PDF

The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area (도심지 발파공사장의 발파진동 특성)

  • 장서일;이연수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.632-638
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured by the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, 2 (perpendicularity) axis was the highest value in vibration level, but vertical direction was the highest value at 25 m point and longitudinal direction was the highest value at 50 m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, Z axis was the highest value in vibration level, but in vibration velocity transverse direction was the highest value at ground, was vertical direction at 1st floor, was longitudinal direction at 3rd floor and was vertical and longitudinal direction at 5th floor. The vibration level and the vibration velocity of 50 m point showed higher correlation value than 25 m point at the ground, but those of 25 m point showed higher correlation value than 50 m point at the apartment.

THE STATISTICAL STUDY OF INTERDENTAL SPACE IN THE PRIMARY DENTITION (유치열(乳齒列)의 치간공극(齒間空隙)에 관(關)한 통계학적(統計學的) 연구(硏究))

  • Ko, Chun-Suk
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.7 no.1
    • /
    • pp.53-61
    • /
    • 1980
  • The purpose of this study was to statistically evaluate the spacing of primary dentition according to whether or not a space existed and measurement of amount of space in 205 children (male 114, female 91) from 2 to 6 years of age. The results were as follows; 1. In the incidence of interdental space on each region, spacing between the primary lateral incisors and primary canine in maxilla and between the primary canine and 1st primary molar in mandible showed the highest percentage, on the other hand, spacing between the 1st and 2nd primary molars in both jaw showed the lowest percentage. 2. In the kinds of interdental space, the state of primate space and other space together showed the highest percentage, and in the degree of spacing, $S_2$ showed the highest percentage in both jaw. 3. In the incidence of primate space, maxillary primate space showed higher percentage than mandibular primate space in bilateral case. 4. In the type of arch form, spaced arch showed higher percentage than closed arch and about the half of closed arch showed crowding. 5. In both Jaw, available space showed incisor segments, canine segments, and premolar segments in order of amount, and there were not statistically significant differences of sex or jaws in the amount of available space.

  • PDF

Measurement of Hydrogenation Characteristics of Pd Film by Using Electrical Resistivity Measurement Technique (전기저항 측정법을 이용한 Pd박막의 수소화 특성 측정)

  • Cho, Young-Sin;Lee, Ho-Jae;Lee, Jong-Suk
    • Journal of Hydrogen and New Energy
    • /
    • v.7 no.2
    • /
    • pp.173-180
    • /
    • 1996
  • 4-probe resistivity measurement technique was used to study kinetics of hydrogen absorption-desorption on Pd film($520{\AA}$ thick) at room temperature upto 1 bar. Kinetics data are fitted well to 1st order kinetics equation in ${\alpha}$ and ${\alpha}^{\prime}$ phases. In ${\alpha}+{\alpha}^{\prime}$ phase, absorption kinetics was very complicated, but it could be explained partially with nucleation and growth process. Ln(dR/dt) vs. time plot gives rate constant k value(R is resistance of sample, t is time). k value for absorption is $4^{-6}{\times}10^{-4}/sec$ in ${\alpha}$ phase. k is increasing upto $4^{\times}10^{-2}/sec$ as hydrogen pressure increasing in ${\alpha}^{\prime}$ phase. k is proportional to ln(Pop/Peq), where Peq is equilibrium plateau pressure and Pop is the opposing pressure. In contrast to bulk sample k value was decreasing with increasing number of A-D cycling in ${\alpha}^{\prime}$ phase absorption.

  • PDF

Spectral Properties of the Sound From the Mechanical Valve Employed in an Implantable Biventricular Assist Device (이식형 양심실 보조 장치에 사용된 기계식 판막의 음향 스펙트럼 특성)

  • 최민주;이서우;이혁수;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.439-448
    • /
    • 2001
  • This paper considers the acoustical characteristics of the closing click sounds of the mechanical valves employed in an implantable biventricular assist device (BYAD) and their re1evance to the Physical states of the valved. Bj rk Shiley Convexo Concave tilting disk valve was chosen for the study and acoustic measurement was made for the BYAD operated in a mock circulatory system as well as implanted in an animal (sheep). In the BYAD operated in the mock circulatory system. three different states of the valve were examined, ie. normal. mechanically damaged. pseudo-thrombus attached. Microphone measurement for the BVAD implanted in the animal was carried out for five days at a regular time interval from one day after implantation. Characteristic spectrum of the sound from the valve was estimated using Multiple Signal Classification (MUSIC) in which the optimal order was determined according to Bayesian Information Criterion (BIC) . It was observed that the mechanical damage of the valve resulted in changes of the structure of the acoustic spectrum. In contrast. the thrombus formed on the valve did not change much the basic structure of the spectrum but brought about altering the spectral Peak frequencies and energies. Maximum spectral Peak (MSP) with the greatest energy was seen at 2 kHz for the normal valve and it was shifted to 3 kHz for the calve attaching the Pseudo-thrombus. Unlike the normal valve, strong spectral Peak appeared around 7 kHz in the sound from the valve mechanically damaged. In the case of the BYAD implanted in the animal. as the thrombus grew, acoustic energy was reduced relatively more in the low frequency components (〈 2 kHz) and the frequencies of the 1st, 2nd and 3rd MSP were increased little. The thrombus formation would result in reduction in both the variability of the 1st, 2nd and 3rd MSP and the value of the BIC optimal order.

  • PDF

Design and Characterization of Low-noise Dewar for High-sensitivity SQUID Operation (고감도 SQUID 냉각을 위한 저잡음 듀아의 설계 및 특성 조사)

  • Yu, K.K.;Lee, Y.H.;Kim, K.;Kwon, H.;Kim, J.M.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.152-157
    • /
    • 2010
  • We have fabricated the low noise liquid helium(LHe) dewar with a different shape of thermal shield to apply the 64-channel SQUID(Superconducting Quantum Interference Device) gradiometer. The first shape of thermal shield was made of an aluminum plate with a wide width of 100 mm slit and the other shape was modified with a narrow width of 20 mm slit. The two types of dewars were estimated by comparing the thermal noise and the signal-to-noise ratio(SNR) of magnetocardiography(MCG) using the $1^{st}$ order SQUID gradiometer system cooled each dewar. The white noise was different as a point of the dewar. The noise was increased as close as the edge of dewar, and also increased at the thermal shield with the more wide width slit. The white noise of the dewar with thermal shield of 100 mm slit was 6.5 fT/$Hz^{1/2}$ at the center of dewar and 25 fT/$Hz^{1/2}$ at the edge, and the white noise of the other one was 3.5 - 7 fT/$Hz^{1/2}$. We measured the MCG using 64-channel SQUID gradiometer cooled at each LHe dewar and compared the SNR of MCG signal. The SNR was improved of 10 times at the LHe dewar with a modified thermal shield.

A Study on Elementary Pre-service Teacher's Understanding about 'Estimation' (초등예비교사의 '어림하기' 이해에 대한 고찰)

  • Kim, Sung Joon
    • East Asian mathematical journal
    • /
    • v.33 no.2
    • /
    • pp.177-197
    • /
    • 2017
  • The purpose of this study is to investigate and analyze the understandings of elementary pre-service teachers about 'estimation' in the elementary mathematics. Together with this analysis, we identify elementary pre-service teacher's Mathematical Pedagogical Contents Knowledge(MPCK), especially focusing to Subject Matter Knowledge(SMK). In order to this goals, we investigate contents relating to 'estimation' from $1^{st}$ curriculum to 2009 revised curriculum and compare 'rounding up', 'rounding off', 'rounding' in the elementary mathematics textbooks. As results of investigations, 'estimation' has been teaching at the 'Measurement' domain from $3^{rd}$ curriculum, but contexts of measuring weaken from $7^{th}$ curriculum. 'Rounding up(off)' is defined three types in the textbooks from $1^{st}$ to 2009 revised curriculum. And we examine elementary pre-service teachers through the questions on these 'estimation' contents. On the analysis of pre-service teacher's understanding relating MPCK, four themes is summarized as followings; the understanding of '0' in the 'rounding up', the cognitive gap between 'rounding up' and 'rounding off', the difference of percentage of correct answers according to types of question in the 'rounding up', and the difference between the definition of 'rounding up' and the definition of 'rounding'.

A Study on Spectral Characteristics of Korean White Pine (Pinus koraiensis $S_{IEB}$ et. $Z_{UCC}$) Needles in Gwangju-gun, Kyunggi-do, Korea (경기도 광주지역 잣나무 침엽의 분광특성에 관한 연구)

  • Joo Yeong-Teuk;Kim Young-Chai;Chung Dong-Jun;Kim Hong-Ryul
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.2
    • /
    • pp.103-109
    • /
    • 1999
  • This study was carried out to investigate spectral characterisistics and chlorophyll contents of Pinus koraiensis needles in Gwangju-gun, Kyunggi-do. In spectrum analysis by each age, needle showed difference on 700∼1,100 nm(NIR : near infrared ray). Light reflexibility keeps constant between 1st year needle and 3rd year needle, current year needle's value was higher than others and that was higher for 400∼500 nm and 600∼700 nm at 550 nm. Transmission to needle's age showed the highest result in current year needle. It showed in order of current, 1st, 2nd and 3rd year needle at 550 nm and 750 nm. Especially, current year needles of Pinus koraiensis showed a tendency to change transmission coefficient in NIR. The result of transmission coefficient measurement by each position of slope showed in order of middle slope, upper slope and lower slope. But the gathered needle in middle slope made marked change at NIR. Chlorophyll a content of the upper slope's needles was higher than other 4 positions but a component ratio was lower. In needle of the oppressed tree, Chlorophyll a content was rather low than others. Chlorophyll a content by slope positions, the upper slope's needle showed a highest value(4.48 mg/g) and lower slope was lowest value(1.35 mg/g). Chlorophyll b content also showed a similar tendency to chlorophyll a and chlorophyll(a+b) contents.

  • PDF

On the study of the measurement of blasting Vibration and Sound influenced to housing structure at Wire-Tunnelling (부산 통신구굴진 발파작업으로 인한 지상주택 구조물에 미치는 진동폭음영향계측조사보고)

  • Huh Ginn
    • Explosives and Blasting
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1990
  • The Caustious blasting have often increased Complaints of ground Vibration and Sound when the Wire-Tunnel Constructed in Pusan. In order to prevent the influence to housing structure, it was necessary to predict blasting-Induced Vibration and Sound. The Suveyer determined the Burden and spacing of Drill holes, minimum delay charges within a allowable Vibration and Sound Level. Tunnel drilling and Ignition patterns are made as follows; No. 1 Tunel (Stable rock, hard rock) No.2 Tunnel (Instable plastic rock; wethered rock) and other Tunnels (Instable rock). The result of 1st testing blasting of No. 1 Tunnel was recorded Under allowable Vibration Level but sound was over 75 Db of allowable value. So Tunnel drilling pattern was amended with 52 Non-charg holes to reduce the blast-sound. The other pattern had no need to amend.

  • PDF