• Title/Summary/Keyword: $1^{st}$ molar

Search Result 238, Processing Time 0.023 seconds

Finite Element Stress Analysis on the Supporting Tissues depending upon the Position of Osseointegrated Implants Supporting Fixed Bridges (고정성 보철물을 지지하는 골유착성 임플란트의 위치에 따른 지지조직에서의 유한요소적 응력분석)

  • Yoon, Dong-Joo;Shin, Sang-Wan;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.87-99
    • /
    • 1993
  • Many studies have been reported on the successful replacement of missing teeth with osseointegrated dental Implants. However, little research has been carried out on the bio-mechanical aspect of the stress on the surrounding bone of the free-standing type of dental implant prostheses. This experimental study was aimed to analyze the stress distribution pattern on the supporting tissues depending upon the position of osseointegrated implants supporting fixed bridges. In the cases of unilateral partially edentulous mandible (the 2nd premolar and the 1st and 2nd molars missing), two osseointegrated implants were placed at the 2nd premolar and 2nd molar sites (Model A) , the 1st and 2nd molar sites (Model B, Anterior cantilevered type), the 2nd premolar and 1st molar sites (Model C, Posterior cantilevered type). Chewing forces of dentate patients and denture wearer were applied vertically on the 2nd premolar, the 1st molar, and the 2nd molar of each model. A 3-Unit fixed partial denture was constructed at each model and cantilevered extension parts were involved in Model B and Model C. Two dimensional finite element analysis was undertaken. The commercial software (Super SAP) for IBM 16 bit personal computer was utilized. The results were as follows : 1. The magnitude of applied load influenced on the total value of stresses, but did not in-fluence on the pattern of stress distribution. 2. The magnitude of stress developed from the supporting tissues were in order of Model C,Model A,Model B. 3. High stresses were concentrated on the cervical and apical portion of the implant/bone interface. 4. A difference of the stress magnitude on the implant/bone interface between mesial and distal implant was most prominant in Model C and in order of Model A and Model B. 5. The stresses developed in Model A were evenly distributed throughout both implants. 6. The stresses concentrated on the cervical portion of cantilevered side were higher in the posterior cantilevered type than in the anterior cantilevered type.

  • PDF

A new rationale for preservation of the mandibular third molar in orthognathic patients with missing molars

  • Baik, Un-Bong;Kim, Yoon-Ji;Chae, Hwa-Sung;Park, Je-Uk;Julian, Stefania;Sugawara, Junji;Lee, Ui-Lyong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.1
    • /
    • pp.63-67
    • /
    • 2022
  • Controversies exist regarding the need for prophylactic extraction of mandibular third molars in patients who plan to undergo orthognathic surgery. An 18-year-old male patient was diagnosed with mandibular prognathism and maxillary retrognathism with mild facial asymmetry. He had a severely damaged mandibular first molar and a horizontally impacted third molar. After extraction of the first molar, the second molar was protracted into the first molar space, and the third molar erupted into the posterior line of occlusion. The orthognathic surgery involved clockwise rotation of the maxillomandibular complex as well as angle shaving and chin border trimming. Patients who are missing or have damaged mandibular molars should be monitored for eruption of third molars to replace the missing posterior tooth regardless of the timing of orthognathic surgery.

ORTHOPANTOMOGRAPHIC STUDY OF THE MAXILLARY SINUS (Orthopantomograph에 의한 상악동의 형태학적 연구)

  • Kim Hyun Joo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.1 no.1
    • /
    • pp.5-11
    • /
    • 1971
  • The author has observed the orthopantomograms of the maxillary sinus which were taken by special exposure method to study mesiodistal dimension, shape, symmetrical relationship, bony septum of the maxillary sinus and relationship between upper. 1st molar and the maxillary sinus, that were selected 56 cases of 23 to 27 years old male, who have good. systemic conditions and no missing teeth on upper posterior molar in normal occlusion, and obtained following conclusions: 1. Mesiodistal dimensions of the maxillary sinus are shown as follows; The mean of left dimension is 50.94±8.34㎜ and of right dimension is 49.50±9.87㎜. 2. To the shape of the maxillary sinus, V or U shape are 33cases(29.5%) and W shape are 77 cases(70.5%). 3. In the ralationship between upper 1st molar and floor of the maxllary sinus, superimposition are 62 cases (55.36%) and aproach are 50 cases (44.64%). 4. In the right and left symmetrical relationship of the maxillary sinus, symmetry are 37cases (66.07%) and asymmetry are 19 cases (33.93%). 5. The bony septums in the maxillary sinuses revealed that presence of bony septums are 29 cases (25.8%) and absence are 83 cases (74.11%).

  • PDF

EFFECTS OF BONE MORPHOGENETIC PROTEIN ON THE HEALING OF PERIODONTIUM AFTER TOOTH REPLANTATION OF THE RAT (치아재식시 골형태형성단백이 치주조직 치유에 미치는 영향)

  • Kim, Ji-Sook;Park, Joon-Bong;Lee, Man-Sup;Kwon, Young-Hyuk;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.501-521
    • /
    • 2002
  • The purpose of this study is to evaluate the influences of the bone morphogenetic protein (BMP) on the healing of periodontal ligament and alveolar bone after replantation of tooth, and to examine the possibility of its clinical application. 45 Sprague Dawley rats weighted about 100 gram were divided into 3 experimental groups by different dose of BMP. All the upper right and left 1st molar were extracted after 5 days feeding of 0.4% ${\beta}$-aminopropionitrile, and right molar were used as experimental group and left molar were used as control group. The root surface of experimental molar were treated with 25,50 and l00ng/ml of human recombinant Bone morphogenetic protein-4 (rh-BMP-4) with micropipet, and 1M Sodium hypochloride were used on control root surface. All the experimental animals were sacrificed as 1, 2, 4, 7 and 14 days after autoreplantation of upper 1st molar into their own position. The maxilla were disected included both side of 1st molar. The collected tissue were processed from demineralization to paraffin embeding as usual procedure, and the specimens were prepared with Hematoxylin-Eosin stain for the light microscopic evaluation. The results of this study were as follows : 1. There was no significant differences between control and experimental site on 1 and 2 days after replantation of tooth. In the case of 4th days, the evidence of tissue regeneration were observed on experimental site to compare the controls. New osteoid were revealed on high concentration of BMP at 7 days after replantation, and it became more obvious at 14 days, 2. The effect of the rh-BMP-4 coated on root surface was revealed slight influences for the prolifertion of cells of periodontium and tissue regeneration as dose-dependent pattern. 3. Bony ankylosis was observed between alveolar bone and root surface due to the remarkable amount of osteoid formation on the 14 days after replantation of root. In the conclusion, it was suggested that topical application of the rhBMP-4 on the root surface has influence on the periodontal ligament and alveolar bone. The application method of BMP on the root should be designed with calculation of proper concentration.

A TWO DIMENSIONAL STRESS ANALYSIS COMPARING FIXED PROSTHETIC APPROACHIES TO THE TILTED MOLAR ABUTMENT

  • YANG, H.S.;Thompson, V.P.
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.1-11
    • /
    • 1991
  • A two dimensional finite element method was used to analyze the changes in mechanical behavior of the supporting structures when a fixed prosthesis replaced a mandibular 1st molar. In the unrestored situation as the degree of bone resorption increased, there was a corresponding increase in stress in the periodontium. Tilting of the molar abutment induced the additional stress on the mesial side of the root. The presence of a fixed prosthesis markedly reduced the magnitude and distribution of stress in the periodontium. The mechanical advantage obtained by a fixed prosthesis was greater in the situation of a tilted 2nd molar with reduced bone support than with the higher bone levels.

  • PDF

A Study on Calcification of Crown of Rermanent Tooth by Orthopantomography (Orthopantomography에 의한 영구치 치관 석회화에 관한 연구)

  • Cho, Sa-Hyun
    • The Journal of the Korean dental association
    • /
    • v.11 no.12
    • /
    • pp.787-799
    • /
    • 1973
  • Surveying the calcification degree of permanent tooth crown in 719 Korean children (Male 387, female 332) from 2 to 10 years old by orthopantomograph, the author got the following results. 1. Female was earlier than male in calcification of permanent teeth. 2. The results of the complete calcification of the permanent tooth crown were as follows. 3. The completion of calcification in the mandibular crown was seen earlier than that of the maxilla. 4. The order of calcification in permanent tooth crowns was as follows : 1 st molar, central incisor, lateral incisor, canine, 1st premolar, 2nd premolar, and 2nd molar. 5. The completion of calcification of the permanent crowns in Korean children was slightly retarded comparing with the Japanese and the American children.

  • PDF

A STUDY ON THE CORRELATIONS BETWEEN MESIODISTAL CROWN DIAMETERS OF THE DECIDUOUS AND SUCCESSIONAL PERMANENT TEETH (유치와 후속 영구치 근원심 폭경의 상관관계에 관한 연구)

  • Lee, Doo-Hee;Chung, Kyu-Rhim;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.15 no.2
    • /
    • pp.341-352
    • /
    • 1985
  • The primary objective of this study is to estimate of the mesiodistal crown diameters of the unerupted permanent successors derived from the mesiodistal crown diameters of the deciduous teeth in Korean population. The subjects were 54 individuals (twenty nine boys and twenty five girls) with normal occlusion aged 6 to 13 years. The mesiodistal crown diameters of the deciduous and the successional permanent teeth were measured from the longitudinal dental cast models using the sliding calipers (Mitutoyo Co.). From the study, the results are as follows; 1. Sex differences of mesiodistal won diameters were less in the deciduous teeth, but male were more than that of female in the successional permanent teeth. 2. The mesiodistal crown diameters of the deciduous central incisors, lateral incisors, canines were smaller than that of the successional permanent teeth and the deciduous 1st molars, and 2nd molars were more larger than that of the successional permanent teeth. 3. Size differences between sum of the mesiodistal crown diameters of central incisors and lateral incisors in the decidous teeth and the successional permanent teeth were $7.20{\pm}1.79mm$ in upper, $5.38{\pm}1.64mm$ in lower and that of canine,1st molar and 2nd molar in the deciduous teeth and the successional permanent teeth were $0.56{\pm}1.19mm$ in upper, $2.22{\pm}1.19mm$ in lower. 4. In male, the correlation coefficients between the upper deciduous central incisor and the successional permanent tooth (r = 0.57) and in female, the correlation coefficients between the upper deciduous 1st molar and the successional permanent tooth (r=0.67) appeared the highest. 5. The regression constants were determined to estimate the mesiodistal crown diameters of the unerupted successional permanent teeth.

  • PDF

Three Dimensional Study of Miniscrew about Installation Area and Angle (미니스크류 식립 각도 및 부위에 대한 3차원적 연구)

  • Jo, Hee-Sang;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • Minimizing damage to anatomical structure is a prerequisite for skeletal anchorage system to install a miniscrew. This research has focused on evaluating the stability and safety of installation in the maxillary molar buccal area, in which most miniscrews are installed clinically and initial fixation is weak. CT (computerized tomography)images were taken for surveying the possibility of damaging to adjucent teeth in accordance with installation angle. If we install a mini-screw($1.2{\times}6.0mm$) in the maxillary molar buccal area, it would be located generally in the 5~8mm upper of CEJ and 3~5mm inner of the cortical bone surface. We has measured the space between roots And comparison has been made for gender and the space between roots in accordance with the 3 different angles of installation(30 degree, 40 degree, 60 degree) in 3 categories. Category 1 : between 1st molar and 2nd molar Category 2 : between 1st molar and 2nd premolar Category 3 : between 1st premolar and 2nd premolar The result are as follow; 1. The space for category 1 was significantly small. 2. For the installation angle, it was safer to install with steeper angle in category 1 and category 2, but not in category 3. According to these results, the installation a miniscrew in category 2, 3 is safer than in category 1. And it is safer to install with steeper angle in category 1 and category 2.

CASE REPORT OF DENTIGEROUS CYST OF MANDIBLE TREATE BY ENUCLEATION (하악골에 발생한 함치성양종의 치험예)

  • Choie, Mok-Kyun;Bae, Chang;Kim, Suck-Kyun
    • The Journal of the Korean dental association
    • /
    • v.16 no.11 s.114
    • /
    • pp.857-860
    • /
    • 1978
  • An instance of dentigerous cyst, 6×2.5×1.5cm, occurred in posterior region of the right mandible, originated from 3rd molar, involved the 2nd premolar, 1st and 2nd molar in a 38-year-old man was observed and surgical enucleation followed by careful excision of all cyst wall was successfully carried out, recovery and healing were rapid and uncomplicated.

  • PDF

Localization of mandibular canal and assessment of the remaining alveolar bone in posterior segment of the mandible with single missing tooth using cone-beam computed tomography: a cross sectional comparative study

  • Alrahaimi, Saif Fahad;Venkatesh, Elluru
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.100-105
    • /
    • 2017
  • Objectives: Localization of the mandibular canal (MC) and measurement of the height and width of the available alveolar bone at the proposed implant site in the posterior segment of the mandible using cone-beam computed tomography (CBCT) in patients with a single missing tooth. Materials and Methods: A cross-sectional study was performed where CBCT scans of the patients with a single missing tooth in the posterior segment of the mandible-premolar, I (1st) molar, and II (2nd) molar were used. The scans were assessed using OnDemand3D software (version 1.0; CyberMed Inc., Seoul, Korea) for localization of the MC asnd remaining alveolar bone both vertically (from the superior position of the MC to the crest of the alveolar ridge) and horizontally (buccolingual, 3 mm below the crest of the alveolar ridge). The findings were statistically analyzed using independent t-test. Results: A total of 120 mandibular sites (40 sites for each of the three missing premolar, I molar, and II molar) from 91 CBCT scans were analyzed. The average heights (from the alveolar crest to the superior margin of the MC) at the premolar, I molar, and II molar areas were $15.19{\pm}2.12mm$, $14.53{\pm}2.34mm$, and $14.21{\pm}2.23mm$, respectively. The average widths, measured 3 mm below the crest of the alveolar ridge, at the premolar, I molar, and II molar areas were $6.22{\pm}1.96mm$, $6.51{\pm}1.75mm$, and $7.60{\pm}2.08mm$, respectively. There was no statistically significant difference between males and females regarding the vertical and horizontal measurements of the alveolar ridges. Conclusion: In the study, the measurements were averaged separately for each of the single missing teeth (premolar, I molar, or II molar), giving more accurate information for dental implant placement.