• Title/Summary/Keyword: ${\sigma}$상

Search Result 187, Processing Time 0.023 seconds

A Design of a Reconfigurable 4th Order ΣΔ Modulator Using Two Op-amps (2개의 증폭기를 이용한 가변 구조 형의 4차 델타 시그마 변조기)

  • Yang, Su-Hun;Choi, Jeong-Hoon;Yoon, Kwang Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.51-57
    • /
    • 2015
  • In this paper, in order to design the A / D converter with a high resolution of 14 bits or more for the biological signal processing, CMOS delta sigma modulator that is a 1.8V power supply voltage - were designed. we propose a new structure of The fourth order delta-sigma modulator that needs four op amps but we use only two op amps. By using a time -interleaving technique, we can re-construct the circuit and reuse the op amps. Also, we proposed a KT/C noise reduction circuit to reduce the thermal noise from a noisy resistor. We adjust the size of sampling capacitor between sampling time and integrating time, so we can reduce almost a half of KT/C noise. The measurement results of the chip is fabricated using a Magna 0.18um CMOS n-well1 poly 6 metal process. Power consumption is $828{\mu}W$ from a 1.8V supply voltage. The peak SNDR is measured as a 75.7dB and 81.3dB of DR at 1kHz input frequency and 256kHz sampling frequency. Measurement results show that KT/C noise reduction circuit enhance the 3dB of SNDR. FOM of the circuit is calculated to be 142dB and 41pJ / step.

A Study on the Statistical Characteristics of Precipitation & Temperature Data of Four Cities and the Statistical Criterion of Climate Change (우리나라 4개 도시의 강수량과 기온자료의 통계적 특성과 기후변화의 통계적 기준에 관한 연구)

  • 이상훈;장영기
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.180-188
    • /
    • 1991
  • 기후변화를 나타내는 연구 결과들은 기온이나 강수량을 대상으로 하여 두 기간 평균치의 비교, 5년 이동평균치의 圖示, 회귀분석 등의 방법들을 사용하여 발표되지만 대부분의 경우 밑바탕이 되는 모집단의 통계적 특성을 엄격히 검토하지 않는 정성적인 분석인 경우가 많다. 서울, 부산, 인천, 목포 등 4개 지점의 80년 동안의 연강수량과 연평균기온자료를 분석한 결과 기온은 정규분포를 나타내므로 전통적인 t-검정과 회귀분석을 적용할 수 있다. t-검정 결과 두 기간(1920 $sim$ 1949, 1961 ~ 1990)은 연평균기온에서 0.3$^{\circ}$C에서 $0.8^{\circ}$C의 의의있는 차이를 보였다. 최근 30년의 연평균기온자료를 회귀분석한 결과 1년에 $0.02^{\circ}$C의 증가경향을 나타내었다. 연강수량은 정적인 왜곡도를 보이므로 정규분포를 가정하는 母數的 통계분석을 적용해서는 안되며 비모수적 통계분석법을 적용해야 한다. 연강수량의 분석에는 t-검정에 상응하는 Mann-Whitney 검정을 적용해 본 결과 두 기간(1920 ~ 1949, 1961 ~ 1990)의 평균은 통계적으로 의의있는 차이가 없었다. 회귀분석에 상응하는 Mann's 검정과 이 연구에서 새로이 제안된 Median Slope Change Estimator를 적용해 본 결과 역시 통계적으로 의의있는 변화가 없었다. Median Slope Change Estimator는 비모수적 통계치로서 회귀분석의 기울기에 해당하는 연변화를 나타낼 수 있는데 분석하려는 자료의 정규분포성을 요구하지 않으며 異常點(outlier) 영향에 덜 민감하다는 장점이 있으므로 주목하여 연구할 만한 가치가 있다.^{\circ}$~40$^{\circ}$ 구간에서는 ${\sigma}_c$와 I$_{sa}$, 40$^{\circ}$~90$^{\circ}$ 구간에서는 ${\sigma}_c$와 I$_{sd}$가 각각 양호한 상관관계를 보여준다. 또한 상관비(K=${\sigma}_c$/I$_s$)는 약 13정도로서 일반적으로 적용되는 비, 24와 상당한 차이가 있다. 이러한 현상은 호상편마암의 구조적 및 역학적 이방성 특성으로 인한 결과라고 판단된다. 한편 맥암류에서 K가 약 23정도로서 일반적인 비 24에 상당히 접근한다. 따라서, 이방성 구조가 뚜렷한 암석에서 상관비 24는 항상 적용할 수는 없으며 일축압축강도시험과 병행 실시하여 적용하는 것이 바람직하다.다. 한편, 감작감염후 77일과 도전감염후 7일의 시점에 있어서 sRBC에 대한 면역능에 미치는 영향은 전자의 양상과 비슷하였는데 대조에 비하여 지연형 과민반응과 로제트 형성능이 현저하게 저하되었다. 이 시점에 있어서의 유충회수율은 대조가 10.5% 이었는데 비하여 8.3%이었다.e also compared for the cases of Kim et al, which again gives promising agreement.면적 306~453$\textrm{cm}^2$, 유색계의 경우 수당면적 340~453$\textrm{cm}^2$ 일 때 경제능력을 제대로 발휘할 수 있고 경제성이 있는 것으로 나타났다. 첨가구가 높은 경향이 있었다8.4%. 79.7% 그리고 80.2%였다.

  • PDF

Design of a Fourth-Order Sigma-Delta Modulator Using Direct Feedback Method (직접 궤환 방식의 모델링을 이용한 4차 시그마-델타 변환기의 설계)

  • Lee, Bum-Ha;Choi, Pyung;Choi, Jun-Rim
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.6
    • /
    • pp.39-47
    • /
    • 1998
  • A fourth-order $\Sigma$-$\Delta$ modulator is designed and implemented in 0.6 $\mu\textrm{m}$ CMOS technology. The modulator is verified by introducing nonlinear factors such as DC gain and slew rate in system model that determines the transfer function in S-domain and in time-domain. Dynamic range is more than 110 dB and the peak SM is 102.6 dB at a clock rate of 2.8224 MHz for voiceband signal. The structure of a ∑-$\Delta$ modulator is a modified fourth-order ∑-$\Delta$ modulator using direct feedback loop method, which improves performance and consumes less power. The transmission zero for noise is located in the first-second integrator loop, which reduces entire size of capacitors, reduces the active area of the chip, improves the performance, and reduces power dissipation. The system is stable because the output variation with respect to unit time is small compared with that of the third integrator. It is easy to implement because the size of the capacitor in the first integrator, and the size of the third integrator is small because we use the noise reduction technique. This paper represents a new design method by modeling that conceptually decides transfer function in S-domain and in Z-domain, determines the cutoff frequency of signal, maximizes signal power in each integrator, and decides optimal transmission-zero frequency for noise. The active area of the prototype chip is 5.25$\textrm{mm}^2$, and it dissipates 10 mW of power from a 5V supply.

  • PDF

Annual Variation and Gas/Particie Partitioning of PCDD/DFs of Ambient Air at Busan, Korea (부산의 대기 중 PCDD/DFs의 연간 변화와 가스/입자상 분배)

  • Ok, Gon;Park, No-Jin;Hwang, Sung-Min;Lee, Seok-Hyung;Kim, Jee-Hoon;Kim, Sung-Yong
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.447-457
    • /
    • 2010
  • This study aims to monitor the variation of concentration of PCDD/DFs between the gaseous phase-particulate phases in the ambient air of urban area in Korea. This monitoring is evaluated by using the Junge-Pankow model and the Koa absorption model with the application of the Octanol-air partition coefficient. In this study, the ambient air samples were analyzed according to each congener group of the PCDD/DFs by HRGC/HRMS, which have been investigated for the past 5 years. In the results, the annual variation in the concentration level of $\Sigma$PCDD/DFs in TSP was increased from $1588\;fg/m^3$ in 1998 to $5123\;fg/m^3$ in 2002, and from 31 fg I-TEQ/$m^3$ to 94 fg I-TEQ/$m^3$ in the $\Sigma$I-TEQ. In the case of PUF of gaseous phase sample, their variation was increased from $1615\;fg/m^3$ in 1998 to $2237\;fg/m^3$ in 2002, and in the $\Sigma$I-TEQ from 12 fg I-TEQ/$m^3$ to 17 fg I-TEQ/$m^3$. The relative coefficient between the gas phase concentration of PCDD/DFs and the temperature was a value of 0.744; the contributive rate of the temperature to the gaseous phase concentration was 0.554. According to the results, the pattern of the coefficient of distribution based on log $p_L^0$ is similar to the ambient air of the urban areas.

Estimation of Daily Net Radiation from Synoptic Meteorological Data (종관기상자료에 의한 순폭사량 추정)

  • 이변우;김병찬;명을재
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.36 no.3
    • /
    • pp.204-208
    • /
    • 1991
  • Five models for net radiation estimation reported by Linacre(1968), Berljand(1956), Nakayama et al. (1983), Chang (1970) and Doorenbos et al. (1977) were tested for the adaptability to Korea. A new model with effective longwave radiation term parameterized by air temperature, solar radiation and vapor pressure was formulated and tested for its accuracy. Above five models with original parameter values showed large absolute mean deviations ranging from 0.86 to 1.64 MJ/$m^2$/day. The parameters of the above five models were reestimated by using net radiation and meteorological elements measured in Suwon, Korea. These five models with new parameter values showed absolute mean deviations ranging from 0.74 to 0.88 MJ/$m^2$/day. The following model was newly formulated: Rn=(1- $\alpha$) Rs- $\sigma$ $T_{k}$$^{4}$ (0.0103 Exp (0 .0731 Rs) -0.0475 (equation omitted) +0 .2478) ($R^2$=0.997, n=63) where $\alpha$ =albedo, $\sigma$=Stefan-Boltzmann constant, Rs=solar radiation in MJ/$m^2$/day, Tk =air temperature in Kelvin and $e_{a}$=vapor pressure in mb. This model revealed 0.4988 MJ/$m^2$/day in absolute mean deviation when applied to an independent set of meteorological data.a.a.

  • PDF

Thermal and Mechanical Properties of Rapidly Solidified Zr-Ni-Cu-Al-Ti Alloy (급냉응고법으로 제조한 Zr-Ni-Cu-Al-Ti 합금의 열적, 기계적 성질)

  • Choe, Ik-Seok;Han, Tae-Gyo;Ji, Yong-Gwon;Im, Byeong-Mun;Kim, Yeong-Hwan;Kim, In-Bae
    • Korean Journal of Materials Research
    • /
    • v.11 no.3
    • /
    • pp.171-177
    • /
    • 2001
  • The thermal and mechanical properties of amorphous Z $r_{62-x}$N $i_{10}$C $u_{20}$A $l_{8}$ $Ti_{x}$ (x=3, 6, 9at%) alloys were investigated. The crystallization process was confirmed as amorphous longrightarrow amorphous + Z $r_2$A $l_3$+ Zr + (Ni,Ti) longrightarrow Z $r_2$Cu + Al + (Ni,Ti) for 3at%Ti, amorphous longrightarrow amorphous + Al longrightarrow $Al_2$Ti + NiZr + CuTi for 6at%Ti and amorphous longrightarrow amorphous + Zr + Al longrightarrow Zr + $Al_2$Zr + Al $Ti_3$+ CuTi for 9at%Ti. lickers hardness ( $H_{v}$ ) increased with increasing volume fraction( $V_{f}$ ) of pricipitates for all concerned compositions. Tensile fracture strength ($\sigma_{f}$ ) showed a maximum value 1219MPa at $V_{f}$ = 38% for 3at%Ti, 1203MPa at $V_{f}$ = 2% for 6at%Ti and 1350MPa at $V_{f}$ = 5% for 9at%Ti. The $\sigma_{f}$ was rapidly decreased after showing the maximum value. The $V_{f}$ corresponding to rapidly decreased $\sigma_{f}$ coincided with the $V_{f}$ transited from ductile to brittle fracture surface.ace.

  • PDF

백동지역 변성염기성암과 그 주변암에서의 고생대 후기 변성작용과 그에 대한 지구조적 의미 해석

  • 오창환;전은영;최선규;송석환
    • Proceedings of the Mineralogical Society of Korea Conference
    • /
    • 2001.06a
    • /
    • pp.143-144
    • /
    • 2001
  • 경기육괴의 남서부에 해당하며 옥천구조대의 북쪽에 위치한 백동-홍성 일대의 충청남도 일원에는 선캠브리아기의 편마암복합체내에 초염기성암체들이 소규모 렌즈상의 암체로 이 지역에 우세한 구조선 방향인 북북동 방향으로 배열되어 산출된다. 이들 초염기성암채들이 조산대에 형성되는 알파인형이며 전형적인 상부 맨틀기원의 암석이 부분용융된 맨틀 잔여물로서 지표로의 이동과정에서 변성작용을 받아 대부분은 사문석화 혹은 활석화된 것으로 보고되어 있다. 본 연구의 주대상인 변성염기성암을 포함하는 백동지역의 초염기성암은 홍성도폭내 덕정리 편암암체 내에 주변 편마암체와 단층으로 접하면서 나타난다. 덕정리 편마암체는 주로 각섬석 화강편마암으로 구성되어있다. 백동지역의 초염기성암내에는 변성염기성암이 층상으로 협재되어 나타난다. 이들 변성염기성암은 석류석, 단사휘석, 각섬석, 사장석으로 주로 이루어진 석류석 각섬암이며 금홍석도 포함하고 있다. 많은 석류석 주변에는 사장석과 각섬석으로 이루어진 심플렉타이트가 발달되어있다. 석류석 각섬암내 심플렉타이트가 형성되지 않은 석류석 가장자리로부터 계산된 변성 온도-압력 조건은 590-72$0^{\circ}C$, 9-l0kb이며 심플렉타이트가 잘 형성된 석류석 주변부로부터는 490-$600^{\circ}C$, 4-6.3kb의 변성 온도-압력 조건이 계산되었다. 이에 반해 변성염기성암을 포함한 초염기성암체 주변에 나타나는 석류석-각섬석 화강편마암으로 부터는 570-78$0^{\circ}C$, 11.6-l6kb의 변성 온도-압력 조건을 얻었다. 석류석 각섬암에서 석류석내에 포획물로 나타나는 휘석(Xjd, 4-11)이 기질에 나타나는 휘석(Xid, 1-6)보다 높은 제이다이트 성분을 갖는다. 이는 석류석 중심부가 석류석 주변부보다 변성압력 조건이 높았을 가능성을 지시한다. 즉 연구지역의 석류석 각섬암은 주변의 각섬석 화강편마암과 같이 에콜로자이트상-상부각섬암상-고압백립암상의 점이대에 해당하는 변성작용을 받은후 초염기성암의 사문암화 작용시기에 1차 후퇴변성작용을 그리고 그후의 활석화 시기에 심플렉타이트를 형성하는 2차 후퇴변성작용을 받았다. 이러한 후퇴변성작용시기에 많은 유체가 침입하였고 그 결과 초염기성암내의 변성염기성암이 주변 화강편마암보다 후퇴변성작용을 강하게 받았을 것으로 예상된다. 변성염기성암의 변성연대를 구하기 위해 두 석류석 각석암 시료에 대해 석류석-전암 Sm-Nd 등시선 연령을 구하였다. 두 개의 석류석 각섬암으로부터 계산된 전암-석류석 연령은 297.9$\pm$5.7(2$\sigma$)Ma 그리고 268.7$\pm$3.3(2$\sigma$)Ma를 나타낸다. 석류석의 Sm-Nd 폐쇄온도가 700-75$0^{\circ}C$임을 고려할 때 두 석류석 각섬암으로부터 계산된 연대는 최고 변성작용 혹은 초기 냉각 시기를 지시할 가능성이 높다. 한편 전암의 두 동위원소 자료로부터 계산된 전암의 연령은 408Ma이다. 이러한 연구 결과는 연구지역의 석류석 각섬암이 시루리아기 후기 혹은 데본기 초기에 관입 후 석탄기 후기에서 페름기 중기에 주변 화강편마암과 함께 섭입작용을 받았을 가능성을 지시한다.

  • PDF

Geochemical Study of the Cretaceous Granitic Rocks in Yeosu Area (여수 지역에 분포하는 백악기 화강암류에 대한 지화학적 연구)

  • Wee, Soo-Meen;Kim, Eun-Hyo
    • Journal of the Korean earth science society
    • /
    • v.30 no.3
    • /
    • pp.267-281
    • /
    • 2009
  • Cretaceous intrusive and extrusive rocks are widely distributed in the southern part of the Korean peninsula, possibly the result of intensive magmatism which occurred in response to subduction of the Pacific plate beneath the northeastern part of the Eurasian plate. Geochemical and petrological study on the Cretaceous granitic rocks of the Yeosu area were carried out in order to constrain the petrogenesis of the granitic rocks and to establish the paleotectonic environment of the southwestern part of the Korean peninsula. Igneous rocks of the Yeosu area consist of diorite, hornblende biotite pite and micrographic granite. Chondrite normalized REE patterns show generally enriched in LREE ($(La/Lu)^{cN}$=4.2-13.3). Diorites show flat to slight negative Eu anomalies while micrographic granites have strong negative Eu anomalies. The ${\Sigma}REE$ of the granites are 76.2-235 ppm, which corresponds to the range of the continental margin granite. Whole rock chemical data of the granitic rocks from the Yeosu area indicate that the rocks have characteristics of calc-alkaline series in the subalkaline field. On the A/NK vs. A/CNK and tectonic discrimination diagrams, parental magma type of the granites corresponds to I-type and volcanic arc granite (VAG). Interpretations of the chemical characteristics of the granitic rocks favor their emplacement in a compressional tectonic regime at continental margin during the subduction of Pacific plate.

Effects of Liquid Surface Tension on the Heat Transfer Coefficient in a Three-Phase Slurry Bubble Column (삼상슬러리 기포탑에서 액상의 표면장력이 열전달 계수에 미치는 영향)

  • Lim, Ho;Lim, Dae Ho;Jin, Hae-Ryong;Kang, Yong;Jung, Heon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.499-504
    • /
    • 2012
  • Characteristics of overall heat transfer were investigated in a three-phase slurry bubble column with relatively low surface tension media, which has been frequently encountered in the fields of industry. The heat transfer phenomena was examined in the system which was composed of a coaxial vertical heater and a proper of bubble column. The heat transfer coefficient was estimated from the measured mean value of temperature difference between the heater surface and the column proper at the steady state condition. Effects of gas velocity ($U_G$), solid fraction in the slurry phase ($C_S$) and surface tension (${\sigma}_L$) of continuous liquid media on the overall heat transfer coefficient (h) in the bubble column were determined. The mean value of temperature difference was estimated from the data of temperature difference fluctuations with a variation of time. The amplitude and mean value of temperature difference fluctuations with respect to the elasped time appeared to decrease with decreasing the surface tension of liquid phase. The overall heat transfer coefficient between the immersed heated and the bubble column increased with an increase in the gas velocity or solid fraction in the slurry phase, but it decreased with an increase in the surface tension of continuous liquid media. The overall heat coefficient in the slurry bubble column with relatively low surface tension media was well correlated in term of operating variables and dimensionless groups within this experimental conditions.

A Study on Tensile Restraint Crack Critical Stress Characteristcs of Gravity-Wet-Type Underwater Welded Joints (중력식 습식 수중용접부의 인강구속균열 임계응력 특성에 관한 연구)

  • O, Se-Gyu;Gang, Mun-Ho;Han, Sang-Deok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.61-65
    • /
    • 1987
  • In this study, the characteristics of TRC (tensile restraint crack) critical stress in the gravity type underwater wet welding process and in the in-air welding have been investigated for Y, y and 45$^{\circ}$r grooves using the KR Grade A-3 steel plates and the E4303 covered electrodes. The following results were obtained: (1) In the TRC tests, the initial critical stress of Y groove is higher than those of the 45$^{\circ}$r single bebel grooves in both in-air and underwater weldings, and the cold fracture sensitivity is higher in the underwater welding than in the in-air welding. (2) The hardness of underwater weld metal is the highest in heat affected zone is about Hk 365 in the in-air weld but Hk 670 in the underwater weld which is higher for cooling speed is more rapid, resulting in the lower critical stress by increase of fracture sensitivity. (3) The diffusible hydrogen quantity for 48 hours is about 18cc/100g-weld-metal in the in-air welding but 48cc/100g-weld-metal in the underwater welding. So that, in the case of underwater welding the diffusible hydrogen penetrates about 3 times more than that in the in-air welding.

  • PDF