• Title/Summary/Keyword: ${\mu}CT$

Search Result 258, Processing Time 0.036 seconds

Identification and Three-Dimensional Characterization of Micropore Networks Developed in Granite using Micro-Focus X-ray CT

  • Choo, Chang-Oh;Takahashi, Manabu;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.179-189
    • /
    • 2014
  • We analyzed the three-dimensional distribution of micropores and internal structures in both fresh and weathered granite using micro-focus X-ray computed tomography (micro-CT). Results show that the pore radius in fresh granite is mostly in the range of $17-50{\mu}m$, the throat radius is in the range of $5-25{\mu}m$, and the coordination number (CN) of pores is less than 10. In contrast, the pore radius in weathered granite is mostly in the range of $20-80{\mu}m$, the throat radius is in the range of $8-30{\mu}m$, and the CN is less than 12. In general, a positive linear relationship exists between pore radius and CN. In addition, both the size and the density of pores increase with an increasing degree of rock weathering. The size of the throats that connect the pores also increases with an increasing degree of weathering, which induces fracture propagation in rocks. Micro-CT is a powerful and versatile approach for investigating the three-dimensional distributions of pores and fracture structures in rocks, and for quantitatively assessing the degree of pore connectivity.

MICRO-CT를 이용한 쥐 대퇴골의 유한요소 해석

  • 변창환;오택열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.296-296
    • /
    • 2004
  • 실험상의 어려움으로 인하여 생체역학 분야에서 유한요소법은 최선의 대안으로 여겨지고 있다. 또한, CT를 비롯한 여러 디지털 장비로부터 얻은 영상데이터를 이용하여 유한요소모델을 생성하는 방법으로 모델 생성 속도의 향상을 가져와 더욱 효율을 높이고 있다. 그러나, 일반 CT의 해상도를 가지고는 골(bone) 변화의 주를 이루고 있는 해면골(trabecular bone)의 변화를 파악하기에는 큰 어려움이 따른다. 이에 본 논문에서는 10~20$\mu\textrm{m}$ 정도까지의 해상도를 가지는 Micro-CT의 영상데이터를 이용하여 유한요소 모델을 생성하고 해석하여 보았다.(중략)

  • PDF

Effects on Alzheimer's disease by Jimitang in CT105-overexpressed SK-N-SH cell lines (CT105로 유도된 신경모세포종 세포주에서 지미탕(指迷湯)의 항치매효과)

  • Kang, Sung-Jun;Park, Chang-Gook;Park, Chi-Sang
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.482-491
    • /
    • 2004
  • Alzheimer's disease(AD) is a geriatric dementia that is widespread in old age. In the near future AD may be the biggest problem in public health service. Although a variety of oriental therapies in the study of Jimitang have been traditionally utilized for the treatment of AD, their pharmacological effects and active mechanisms have not been fully elucidated. This study in an investigation of effects of Jimitang on apoptotic cell death induced by CT105 overexpression in SK-N-SH neuroblastoma cell lines. DNA fragmentation, neurite outgrowth assay and LDH activity assay were examined. The regeneratory and inhibitory effects on Alzheimer's disease in pCT105-induced neuroblastoma cell lines by Jimitang water extract were examined. Findings from these experiments have shown that Jimitang inhibits the synthesis or activities of CT105, which has neurotoxicities and apoptotic activities in cell lines. In addition, pretreatment of $Jimitang(>50\;{\mu}g/mL\;for\;12\;hours)$ partially prevented CT(105)-induced cytotoxicity in SK-N-SH cell lines, and were inhibited by pretreatment. $Jimitang(>50\;{\mu}g/mL\;for\;12\;hours)$ repaired CT(105)-induced neurite outgrowth when SK-N-SH cell lines were transfected with CT(105). Results of this study show that. in the Jimitang group, the apoptosis in the nervous system in inhibited, the repair against the degerneration of neuroblastoma cells by CT105 expression is promoted. In addition, Jimitang was found to inhibit DNA fragmentation induced by CT105 overexpression, and promote neurite outgrowth. These findings suggest that Jimitang is beneficial for the treatment of AD.

  • PDF

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Hevey Metal Levels in Urine of Residents in Industrial Area (일부 공단지역 주민의 요 중 중금속 농도에 관한 연구)

  • Jou, Hye-Mee;Choi, Su-Hyeon;Chung, Eun-Kyung;Jung, Soon-Won;Yang, Won-Ho;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.565-574
    • /
    • 2011
  • This study analyzed the concentration of the heavy metals(Cd, Hg, iAs) of urine(n=576) from May, 2007 to Oct 2007. The subject was residents in G, Y, H industrial area, Jeollanam-do, in which exposure due to the adjacency of the industrial complex. As to the heavy metal concentration in the urine of the residents in the whole exposed region and the comparing region, the content of cadmium, mercury, and inorganic arsenic in the exposed region group were 1.23, 1.85, and 8.80 ${\mu}g$/g_ct respectively, and those of the comparing region group were 1.87, 2.00, and 8.93 ${\mu}g$/g_ct respectively, which indicates that the concentration of the comparing group was higher than that of the exposed group. The heavy metal concentration for each age group increased in proportion to age except those under 10 for some substances(p<0.01). As to geometric mean concentration cadmium and inorganic arsenic in urine according to the smoking history of the subject, the concentration of the smoking group and the non-smoking group were 1.65 ${\mu}g$/g_ct and 9.13 ${\mu}g$/g_ct respectively, while those of the non-smoking group were 1.47 ${\mu}g$/g_ct and 8.91 ${\mu}g$/g_ct respectively, which indicates that the former is higher than the latter. As to the inorganic arsenic concentration in urine according to the food preference, in order of vegetable, fish, and meat showed high concentration (p<0.01). To clarify the factors affecting the heavy metal concentration in urine among the subjects, the multiple regression analysis was conducted. As a result, it turned out that as to cadmium content in urine, gender, age, drinking, and smoking have influence on the subjects, with explanatory adequacy of 37.5 %.

Effect of Mutan Isolated from Streptococcus mutans on the Healing of Bone Defect in Rat (Streptococcus mutans로부터 분리한 Mutan이 흰쥐의 골결손부 치유에 미치는 영향)

  • Kwon, Hyun-Jung;Kim, Yong Hyun;Han, Kook-Il;Jung, Eui-Gil;Han, Man-Deuk
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.98-105
    • /
    • 2015
  • We investigated the effects of a mutan (water-insoluble ${\alpha}$-glucans) isolated from Streptococcus mutans on the healing of bone defect in rat. Sprague-Dawley rats were divided into control (saline-treated), lipopolysaccharide (LPS)-treated, and mutan-treated groups (n=6 per group). Experimental bone defects were surgically created with round fissure bur at the buccal surface of the left mandibular. The control groups was administered with saline solution (0.1 ml/100 g), while the LPS and mutan group was given LPS and mutan (1 mg/kg body weight) three times weekly. After 4 weeks the rats were sacrificed, the healing of bone defect was assessed by bone mineral density (BMD) and micro-computed tomography (${\mu}CT$) examination. Percent bone volume (bone volume/tissue volume [BV/TV]), trabecular thickness (Tb.Th), and trabecular number (Tb.N) parameters of ${\mu}CT$ showed higher values in control group than LPS and mutan group. Bone surface/volume ratio (BS/BV), trabecular bone pattern factor (Tb.Pf), and structure model index parameters of ${\mu}CT$ showed higher values in LPS group than mutan group. BMD values of mutan treated-alveolar bones were significantly lower for than that of the LPS group. Therefore, we suggest that mutan, water-insoluble ${\alpha}$-glucans from S. mutans may be induce the induction of periodontal diseases.

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.