• Title/Summary/Keyword: ${\mu}-CT$

Search Result 258, Processing Time 0.03 seconds

The Microstructure and Microwave Dielectric Properties of Ceramics in the System CaTiO3-Li0.5Nd0.5TiO3

  • Lowe, Tristan;Azough, Feridoon;Freer, Robert
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.4
    • /
    • pp.328-332
    • /
    • 2003
  • Ceramics of xCaTiO$_3$-(1-x)Li$_{0.5}$Nd$_{0.5}$TiO$_3$(xCT-(1-x)LNT) series have been prepared by the mixed oxide route. Powders were calcined at 110$0^{\circ}C$ ; cylindrical specimens were fired at temperatures in the range 1300-150$0^{\circ}C$. Sintered products were typically 90-95% dense. The microstructures were dominated by angular grains typically 1.3${\mu}{\textrm}{m}$ to 3.5 ${\mu}{\textrm}{m}$ in size. Twinning in the microstructures was analysed using Electron Back Scattered Diffraction (EBSD). Microwave dielectric properties of xCT-(1-x)LNT at 2.1 GHz ($\varepsilon$$_{r}$, Qxf, and $\tau$r) were 170,3800 GHz and 744 ppm/$^{\circ}C$ for pure CaTiO$_3$ and 80,2000 GHz and -240 ppm/$^{\circ}C$ for LNT. The $\tau$r decreases almost linearly from 744 for pure CaTiO$_3$ to -240 for pure LNT.LNT.T.

Red Ginseng Extract Reduced Metastasis of Colon Cancer Cells In Vitro and In Vivo

  • Seo, Eun-Young;Kim, Woo-Kyoung
    • Journal of Ginseng Research
    • /
    • v.35 no.3
    • /
    • pp.315-324
    • /
    • 2011
  • This study investigated the effect of red ginseng extract on metastasis of colon cancer cells in vitro and in vivo. Wound healing migration, cell motility, invasion, and activity, protein expression, and mRNA expression of matrix metalloproteinases (MMPs) were examined in SW480 human colon cancer cells. SW480 cells were cultured with or without $100{\mu}g/L$ PMA in the absence or presence of various concentrations (100, 200, or $300{\mu}g/mL$) of red ginseng extract. Red ginseng extract treatment caused signifi cant suppression of cell motility and invasion (p<0.05) in SW480 cells. Red ginseng extract inhibited MMP-2 and MMP-9 activity and their protein and mRNA expression in a dose-dependent manner (p<0.05) in SW480 cells. For experimental metastasis, BALB/c mice were injected intravenously with CT-26 mouse colon cancer cells in the tail vein, and were orally administered various concentrations (0, 75, 150, or 300 mg/kg body weight) of red ginseng extract for 3 weeks. Numbers of pulmonary nodules were signifi cantly decreased in mice that were fed red ginseng extract (p<0.05). Plasma MMP-2 and MMP-9 activity signifi cantly decreased in response to treatment with red ginseng extract in mice (p<0.05). These data suggest that red ginseng extract may be useful for prevention of cancer invasion and metastasis through inhibition of MMP-2 and MMP-9 pathways.

Nondestructive Evaluation of Microstructure of SiCf/SiC Composites by X-Ray Computed Microtomography

  • Kim, Weon-Ju;Kim, Daejong;Jung, Choong Hwan;Park, Ji Yeon;Snead, Lance L.
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.378-383
    • /
    • 2013
  • Continuous fiber-reinforced ceramic matrix composites (CFCCs) have a complex distribution of porosity, consisting of interfiber micro pores and interbundle/interply macro pores. Owing to the complex geometry of the pores and fiber architecture, it is difficult to obtain representative microstructural features throughout the specimen volume with conventional, destructive ceramographic approaches. In this study, we introduce X-ray computed microtomography (X-ray ${\mu}CT$) to nondestructively analyze the microstructures of disk shaped and tubular $SiC_f$/SiC composites fabricated by the chemical vapor infiltration (CVI) method. The disk specimen made by stacking plain-woven SiC fabrics exhibited periodic, large fluctuation of porosity in the stacking direction but much less variation of porosity perpendicular to the fabric planes. The X-ray ${\mu}CT$ evaluation of the microstructure was also effectively utilized to improve the fabrication process of the triple-layered tubular SiC composite.

마우스 골재생모델의 제작방법 검토와 골질(bone quality) 및 골양(bone quantity) 파라미터의 해석

  • Lee, Ji-Uk;Kawahara, Keita;Nakano, Takayoshi;Kim, Seung-Eon;Yun, Hui-Suk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.44.1-44.1
    • /
    • 2009
  • 최근 경조직 재생 (hard tissue regeneration) 에 대한 연구가 활발히 진행되고 있다. 그러나 이와같은 연구는 결손도입의 어려움 및 이차적인 골절의 위험성 때문에 대형동물을 중심으로 진행되고 있으며, 그 결과 동물실험에 있어서 시간적 경제적으로 큰 리스크를 수반한다. 그러나 유전자 변형동물의 대부분은 마우스이며, 분자생물학적 관점에서 골재생의 과정을 이해하기 위해서는 마우스를 이용한 골재생 모델의 확립이 필요하다. 따라서 본 연구에서는 마우스를 통해 경조직 재생모델의 제작방법을 검토함과 동시에, 골재생부위에 대한 골질 (bone quality) 및 골양 (bone quantity) 평가의 방법을 수립하는 것을 목적으로 하였다. 골결손은 생후 8주의 마우스에 시술하였다. 치과용 드릴을 이용하여 경골 (tibia) 길이의 30 % 부근의 내측(medial) 면에서 골수강 (marrow cavity) 방향으로 $500\;{\mu}m\varphi$의 원주형 결손을 도입하였다. 시술 후의 골재생과정을 관찰하기 위해 ${\mu}CT$ (SMX-100CT: Simazu) 를 이용하여 주기적으로 촬영하였으며, 골양 (BV/TV) 의 회복과정은3D-bon (RATOC) 을 이용하여 정량적인 해석을 수행하였다. 그리고 재생부의 골질 (아파타이트 배행성; BAp orientation) 평가는 투과형micro-beam XRD (R-AXIS BQ: Rigaku)를 이용하여 수행하였다.

  • PDF

The effect of high-temperature on foamed concrete

  • Canbaz, Mehmet;Dakman, Hafid;Arslan, Baris;Buyuksungur, Arda
    • Computers and Concrete
    • /
    • v.24 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Within the scope of this study, the foam solution was prepared by properly mixing sulfonate based foam agent with water. Furthermore, this solution was mixed with the mixture of fine sand, cement, and water to produce foamed concrete. The mixture ratios which are the percentage of foam solution used in foam concrete were chosen as 0, 20, 40 and 60% by vol. After these groups reached 28 days of strength, they were heated to 20, 100, 400 and $700^{\circ}C$ respectively. Afterward, high-temperature effects on the foamed concrete were obtained by employing physical and mechanical properties tests. Additionally, SEM (scanning electron microscope) and EDX (energy-dispersive X-ray spectroscopy) tests were employed to analyze the microstructure, and ${\mu}-CT$ (micro computed tomography) images were used to reconstruct 3-D models of the heat-treated specimens. Then, these models are analyzed to examine the void structures and the changes in these structures due to the high temperatures. The study has shown that the void structures reduce the high-temperature effects and the foam solution could be mixed with concrete up to 40 % by vol. where the high strength of foamed concrete is non-mandatory.

Studies on the antimetastasis & antiangiogenesis effects of Gamisoamsan (가미소암산(加味消癌散)의 혈관신생(血管新生) 억제에 관한 항암효과 연구)

  • Yoon Sung-Chan;Ahn Seong-Hun;Kim Jin-Kyeoung;Mun Yeon-Ja;Chu Yeong-Guk;Jeong Gyu-Yong;Whoo Won-Hong
    • Herbal Formula Science
    • /
    • v.10 no.2
    • /
    • pp.113-126
    • /
    • 2002
  • Soamsan is known as an anti-cancer remedy in the traditional Korean Medicine. To enhance the synergic effects of anti-cancer activity of Soamsan, this study reconstituted the original components of Soamsan with a slight modification and produced a novel herbal remedy, namely Gamisoamsan. Extracts of Gamisoamsan inhibited the growth of cultured CT-26 cells, mouse colon adenocarcinoma, in a dose-dependent manner $(1\;to\;50{\mu}g/ml)$, and $ID_{50}$ was estimated approximately $16.7{\mu}g/ml$. Using tumor-bearing mouse model, in which was produced by subcutaneous injection of CT-26 cells ($1{\times}10^5$cells). the effects of Gamisoamsan on tumor growth and host survival were examined by evaluating tumor volume and increase in life span. When Gamisoamsan extracts in variable doses of 100, 200 and 500mg/kg body weight per day were orally administered to tumor-bearing mice, following results were obtained: Improvement in the hematological parameters following Gamisoamsan treatment such as hemoglobin contents, red blood cells and white blood cells of the tumor-bearing mice have been observed. Gamisoamsan treatment also showed a prolongation of life span and a reduction of tumor volume in the CT-26 tumor hosts. The results of the present study suggest that Gamisoamsan extracts has a potential anti-tumor activity and may be an useful remedy to prevent and/or treat cancer.

  • PDF

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF

The Consideration of nuclear medicine technologist's occupational dose from patient who are undergoing 18F-FDG Whole body PET/CT : Aspect of specific characteristic of patient and contact time with patient (18F-FDG Whole Body PET/CT 수검자의 거리별 선량 변화에 따른 방사선 작업종사자의 유효선량 고찰: 환자 고유특성 및 응대시간 측면)

  • Kim, Sunghwan;Ryu, Jaekwang;Ko, Hyunsoo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.67-75
    • /
    • 2018
  • Purpose The purpose of this study is to investigate and analyze the external dose rates of $^{18}F-FDG$ Whole Body PET/CT patients by distance, and to identify the main factors that contribute to the reduction of radiation dose by checking the cumulative doses of nuclear medicine technologist(NMT). Materials and Methods After completion of the $^{18}F-FDG$ Whole Body PET/CT scan($75.4{\pm}3.3min$), the external dose rates of 106 patients were measured at a distance of 0, 10, 30, 50, and 100 cm from the chest. Gender, age, BMI(Body Mass Index), fasting time, diabetes mellitus, radiopharmaceutical injection information, creatine value were collected to analyze individual factors that could affect external dose rates from a patient's perspective. From the perspective of NMT, personal pocket dosimeters were worn on the chest to record accumulated dose of NMT who performed the injection task($T_1$, $T_2$ and $T_3$) and scan task($T_4$, $T_5$ and $T_6$). In addition, patient contact time with NMT was measured and analyzed. Results External dose rates from the patient for each distance were calculated as $246.9{\pm}37.6$, $129.9{\pm}16.7$, $61.2{\pm}9.1$, $34.4{\pm}5.9$, and $13.1{\pm}2.4{\mu}Sv/hr$ respectively. On the patient's aspect, there was a significant difference in the proximity of gender, BMI, Injection dose and creatine value, but the difference decreased as the distance increased. In case of dialysis patient, external dose rates for each distance were exceptionally higher than other patients. On the NMT aspect, the doses received from patients were 0.70, 1.09, $0.55{\mu}Sv/person$ for performing the injection task($T_1$, $T_2$, and $T_3$), and were 1.25, 0.82, $1.23{\mu}Sv/person$ for performing the scan task($T_4$, $T_5$, $T_6$). Conclusion we found that maintaining proper distance with patient and reducing contact time with patient had a significant effect on accumulated doses. Considering those points, efforts such as sufficient water intake and encourage of urination, maintaining the proper distance between the NMT and the patient(at least 100 cm), and reducing the contact time should be done for reducing dose rates not only patient but also NMT.

Computer-Aided Diagnosis for Liver Cirrhosis using Texture features Information Analysis in Computed Tomography (컴퓨터단층영상에서 TIA를 이용한 간경화의 컴퓨터보조진단)

  • Kim, Chang-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Choi, Seok-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.4
    • /
    • pp.358-366
    • /
    • 2012
  • Cirrhosis is a consequence of chronic liver disease characterized by replacement of liver tissue by fibrosis, scar tissue and regenerative nodules leading to loss of liver function. Liver Cirrhosis is most commonly caused by alcoholism, hepatitis B and C, and fatty liver disease, but has many other possible causes. Some cases are idiopathic disease from unknown cause. Abdomen of liver Computed tomography(CT) is one of the primary imaging procedures for evaluating liver disease such as liver cirrhosis, Alcoholic liver disease(ALD), cancer, and interval changes because it is economical and easy to use. The purpose of this study is to detect technique for computer-aided diagnosis(CAD) to identify liver cirrhosis in abdomen CT. We experimented on the principal components analysis(PCA) algorithm in the other method and suggested texture information analysis(TIA). Forty clinical cases involving a total of 634 CT sectional images were used in this study. Liver cirrhosis was detected by PCA method(detection rate of 35%), and by TIA methods(detection rate of 100%-AGI, TM, MU, EN). Our present results show that our method can be regarded as a technique for CAD systems to detect liver cirrhosis in CT liver images.

Metal artifact SUV estimation by using attenuation correction image and non attenuation correction image in PET-CT (PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰)

  • Kim, June;Kim, Jae-II;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.21-26
    • /
    • 2016
  • Purpose Because of many advantages, PET-CT Scanners generally use CT Data for attenuation correction. By using CT based attenuation correction, we can get anatomical information, reduce scan time and make more accurate correction of attenuation. However in case metal artifact occurred during CT scan, CT-based attenuation correction can induce artifacts and quantitative errors that can affect the PET images. Therefore this study infers true SUV of metal artifact region from attenuation corrected image count -to- non attenuation corrected image count ratio. Materials and Methods Micro phantom inserted $^{18}F-FDG$ 4mCi was used for phantom test and Biograph mCT S(40) is used for medical test equipment. We generated metal artifact in micro phantom by using metal. Then we acquired both metal artifact region of correction factor and non metal artifact region of correction factor by using attenuation correction image count -to- non attenuation correction image count ratio. In case of clinical image, we reconstructed both attenuation corrected images and non attenuation corrected images of 10 normal patient($66{\pm}15age$) who examined PET-CT scan in SNUH. After that, we standardize several organs of correction factor by using attenuation corrected image count -to- non attenuation corrected count ratio. Then we figured out metal artifact region of correction factor by using metal artifact region of attenuation corrected image count -to- non attenuation corrected count ratio And we compared standard organs correction factor with metal artifact region correction factor. Results according to phantom test results, metal artifact induce overestimation of correction factor so metal artifact region of correction factors are 12% bigger than the non metal artifact region of correction factors. in case of clinical test, correction factor of organs with high CT number(>1000) is $8{\pm}0.5%$, correction factor of organs with CT number similar to soft tissue is $6{\pm}2%$ and correction factor of organs with low CT number(-100>) is $3{\pm}1%$. Also metal artifact correction factors are 20% bigger than soft tissue correction factors which didn't happened metal artifact. Conclusion metal artifact lead to overestimation of attenuation coefficient. because of that, SUV of metal artifact region is overestimated. Thus for more accurate quantitative evaluation, using attenuation correction image count -to-non attenuation correction image count ratio is one of the methods to reduce metal artifact affect.

  • PDF