• Title/Summary/Keyword: ${\mu}-CT$

Search Result 258, Processing Time 0.023 seconds

Corrosion Quantification of Reinforcing Bar in Concrete Using Micro Computer Tomography (Micro-CT 활용 콘크리트 내 철근 부식 정량을 위한 실험적 연구)

  • Jang, In-Dong;Yi, Chong-Ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.252-253
    • /
    • 2019
  • Corrosion of rebars in reinforced concrete structures is a major factor that shortens the life of the structure. As corrosion progresses, the adhesion between the concrete tissues and the rebar decreases and the cracks in the concrete due to the expansion of the oxide intensify. Although it is necessary to measure corrosion behavior of rebars inside the concrete to measure degradation of structures due to rebar corrosion, no studies have been conducted to measure corrosion of rebars in In-situ state. In this study, corrosion of rebars in reinforced concrete specimens was attempted to be quantified using micro-computer tomography. Since corrosion of concrete takes several months per 10mm of cover, accelerated corrosion techniques were applied. Accelerated corrosion on the specimen was conducted by applying a 10 V magnetic field to the buried rebar and external electrodes with the specimen submerged in a 10% calcium chloride solution. The experiment found that within two weeks, more than 40% of rebar reduction occurred, and the cracks in the radial cracks occurred through the concrete structure, leading to the transfer of the oxide produced through the cracks to the surface of the specimen.

  • PDF

Aseptic Meningitis after a Lumbar Epidural Steroid Injection -A case report- (요부 경막외 스테로이드 주입 후 발생한 무균성 수막염 -증례 보고-)

  • Hwang, Byeong Mun;Leem, Jung Gil
    • The Korean Journal of Pain
    • /
    • v.18 no.1
    • /
    • pp.52-55
    • /
    • 2005
  • Complications following a well conducted epidural steroid injection are rare. A 50-year-old man developed a headache and neck stiffness 2 days after a lumbar epidural steroid injection. Under the impression of aseptic meningitis, fluid and nonsteroidal anti-inflammatory drug therapy was started immediately after cerebrospinal fluid (CSF) sampling. The CSF was turbid, and revealed a white blood cell count, protein, glucose and pressure of $550/{\mu}l$ (98% lymphocyte), 107.9 mg/dl, 48 mg/dl (serum 113 mg/dl) and $17cmH_2O$, respectively. The CSF stain and culture, and antibody test and polymerase chain reaction for pathogens were negative. A computed tomography (CT) scan of the brain revealed no abnormality, and a chest roentgenogram and the results of the neurological examination were normal. Under the impression of aseptic meningitis, the condition was managed conservatively, without antibiotics. Seven days later, the clinical symptoms had improved, and the patient discharged.

Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon (직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가)

  • Jung, hae youn;Seok, jin yong;Hong, joo wan;Chang, nam jun;Choi, byeong don;Park, jin hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose : The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Materials and Methods : Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and $R_{50%}$ was calculated to assess low dose spillage as per treatment plan. $D_{25%}$ of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. Results : There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and $R_{50%}$ on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum $D_{25%}$ was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest time was observed on 1A-VMAT. All plans indicated over 99.5%(p=0.00) of gamma pass rate (2 mm, 2%) in portal dosimetry quality assurance. Conclusion : As a result of study, postoperative prostate cancer radiation therapy for patient using a rectal balloon, there was no significant difference of PTV coverage but 1A-VMAT and 2A-VMAT were more efficient for dose reduction of normal tissue and OARs. Between VMAT plans. $R_{50%}$ and MU were little lower in 2A-VMAT but 1A-VMAT has the shortest delivery time. So it is regarded to be an effective plan and it can reduce intra-fractional motion of patient also.

  • PDF

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

Outcome of typhlitis in children with cancer (소아암 환자에서 발생한 막창자염(typhlitis)의 치료성적)

  • Lee, Jae Min;Choi, Kwang Hae;Hah, Jeong Ok
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.2
    • /
    • pp.156-161
    • /
    • 2008
  • Purpose : Neutropenic enterocolitis is an acute, life-threatening inflammation of the small and large bowel, often seen in children with malignancies during periods of prolonged or severe neutropenia. The optimal management for typhlitis in pediatric oncology patients has been debateful between operative and nonoperative approaches. The purpose of this study was to review the outcome of medical management of patients who were diagnosed as typhlitis. Methods : The records of 207 pediatric cancer patients who were diagnosed and treated at the pediatric department of Yeungnam University Hospital for cancer between August, 2002 and July, 2007 were reviewed. Results : Among 207 patients, 12 (5.7%) children aged 9 to 14 years, were diagnosed clinically to have typhlitis. Clinical symptoms and signs of patients were fever, abdominal pain and tenderness, diarrhea, vomiting and rebound tenderness. Bowel-wall thickening (> 4mm) was seen on CT or ultrasonography. All patients were treated with antibiotics combinations of teicoplanin, carbapenem, aminoglycoside, or other third generation cephalosporin and metronidazole or clindamycin. Eight patients were treated with additional antifungal agents. Other supportive management included bowel rest, total parenteral nutrition, and G-CSF administration. All patients recovered completely and did not need any surgical management. Conclusion : Early diagnosis and aggressive supportive treatment appears to be important for complete recovery and survival of typhlitis.

Clinical Usefulness of D-dimer Test with Semiquantitative Latex Agglutination Method in Pulmonary Embolism (폐색전증에서 반정량적 Latex 응집법으로 시행한 D-dimer 검사의 유용성에 관한 연구)

  • Kim, Dong Kyun;Chun, Kang Il;Kim, Yang-Ki;Lee, Young-Mok;Kim, Ki Up;Uh, Soo-taek;Kim, Yong Hoon;Park, Choon Sik;Park, No Jin;Choi, Tae Youn
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.651-655
    • /
    • 2005
  • Background : Diagnosing a pulmonary embolism is difficult because its presenting symptoms are nonspecific and there are limitations with all of the objective tests. The D-dimer is known to be a marker of the lysis of intravascular cross-linked fibrin as a result of the activation of the endogenous fibrinolytic pathways, and the D-dimer assay is these an objective method for diagnosing a pulmonary embolism. This study assessed the benefits of the D-dimer test for diagnosing a pulmonary embolism using semiquantitative latex agglutination. Methods : The latex agglutination results of 185 patients were retrospectively reviewed. The D-dimer test was performed at the time a pulmonary embolism was suspected. Ninety patients(group I) were diagnosis with PE through spiral chest CT or a chest CT angiogram, perfusion/ventilation scans, and/or pulmonary angiogram. Ninety-five patients (group II) were found not to have a pulmonary embolism through the above tests. Results : The male to female ratio and mean age in groups I and II was 37:55, and 57 years old to 50:45 and 52 years old, respectively. When the cut off value for a positive D-dimer assay was set to $500{\mu}g$, the sensitivity, positive predictive value, negative predictive value and specificity was 86.7%, 61.4%, 79.3%, and 48.4%, respectively. Conclusion : The semiquantitative latex agglutination method in the D-dimer test has a lower sensitivity and negative predictive value than the well known ELISA test particularly for small emboli. Therefore, this test is not a suitable screening test for excluding a pulmonary embolism.

Tissue Inhomogeneity Correction in Clinical Application of Transmission Dosimetry to Head and Neck Cancer Radiation Treatment (두경부 방사선 치료 환자에서 투과선량 알고리즘의 임상 적용시 불균질 조직 보정에 관한 연구)

  • Kim Suzy;Ha Sung Whan;Wu Hong Gyun;Huh Soon Nyung
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.155-163
    • /
    • 2004
  • Purpose : To confirm the reproducibility of in vivo transmission dosimetry system and the accuracy of the a1gorithms for the estimation of transmission dose in head and neck radiation therapy patients. Materials and Methods : From September 5 to 18, 2001, transmission dose measurements were peformed when radiotherapy was given to brain or head and neck cancer patients. The data of 35 patients who were treated more than three times and whose central axis of the beam was not blocked were analyzed in this study. To confirm the reproducibility of this system, transmission dose was measured before dally treatment and then repetitively every hour during the treatment time, with a field size of 10$\times$10 cm$^{2}$ and a delivery of 100 MU. The accuracy of the transmission dose calculation algorithms was confirmed by comparing estimated dose with measured dose. To accurately estimate transmission dose, tissue inhomogeneity correction was done. Results : The measurement variations during a day were within $\pm$0.5$\%$ and the dally variations in the checked period were within $\pm$ 1.0$\%$, which were acceptable for system reproducibility. The mean errors between estimated and measured doses were within $\pm$5.0$\%$ in Patients treated to the brain, $\pm$2.5$\%$ in head, and $\pm$ 5.0%$\%$in neck. Conclusion : The results of this study confirmed the reproducibility of our system and its usefulness and accuracy for dally treatment. We also found that tissue inhomogeneity correction was necessary for the accurate estimation of transmission dose in patients treated to the head and neck.

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

Increased Regulatory T cells in Thyroid Adenocarcinoma in a Mixed Breed Dog (갑상샘 암종을 가진 개에서 조절 T 세포의 증가)

  • Kim, Jun-Hwan;Hong, Yeon-Jung;Kim, Bumseok;Kim, Yunhye;Park, Jin-Ho;Chung, Tae-Ho;Park, Chul
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.482-485
    • /
    • 2013
  • This case report describes the increment of regulatory T cells in thyroid carcinoma of a mixed breed dog compared with normal dogs. A mixed breed dog was referred for a submandibular mass and hyperthermia. Right cervical mass was detected during the physical examination and radiography identified right cervical mass suspected thyroid gland. Accurate location and size of mass was confirmed using computed tomography and 3D reconstructed images. After confirmation of mass, surgical resection was performed and evaluation of regulatory T cells in blood of this patient was performed using flow cytometric assay. The percentage of regulatory T cells was 38.28% of all CD4 (+)/CD25 (+) T cells. This result was higher than median percentage of regulatory T cells of healthy 8 beagles ($7.66{\pm}1.65%$ (p<0.01) of all CD4 (+)/CD25 (+) T cells). And masses were confirmed as giant cell thyroid carcinoma based on histopathologic examination. After surgical resection of cervical mass was performed, the owner didn't want chemotherapy. Seven days later, cervical mass came out again. And CBC showed severe leukocytosis (WBC $47.6{\times}10^3/{\mu}L$) and non-regenerative anemia (PCV 21%). Suspected pulmonic metastasis regions became more severe. Finally the dog died of severe anemia and respiratory disorder.

Suppression of Osteoporotic bone loss on the site to which low Intensity Ultrasound is Irradiated - In vivo test on BMD and Morphological Characteristics (저강도 초음파 조사 부위의 골 소실 억제 효과 -골 밀도 및 형태학적 특성 평가)

  • Ko, Chang-Yong;Seo, Dong-Hyun;Kim, Hyo-Seon;Kim, Han-Sung;Kim, Sang-Hee;Kim, Jin-Man;Kim, Ki-Won;Lim, Do-Hyung
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • Purpose : The aim of this study is to evaluate a possibility of clinical application for the effects of low intensity ultrasound stimulation (LIUS) in morphological characteristics (i.e., structure, bone mineral density) of bone on osteoporotic fracturesprevention. Materials and Methods : Eight virgin 14-week-old ICR mice (approximate weight 25g) were used and ovariectomized (OVX) to induce osteoporosis. Right tibia (US) for each mouse served as the LIUS (1.5MHz frequency, 1.0 kHz pulse repetition on frequency, $30mW/cm^2$ intensity, $200{\mu}s$ pulse length, and stimulation for 20 minutes a day and 5 days a week over a 6-week period). Left tibia (CON) for each mouse served as the non-stimulated controls. Structural parameters and bone mineral density ($g/cm^3$) on trabecular bone of tibiae were calculated and measured from images derived in-vivo micro computed tomography (micro-CT) at 0 week and after 6weeks. Results : The BV/TV and Tb.N in US group were significantly bigger than those in CON group. The Tb.Pf in US group, moreover, was significantly smaller than that in CON group (p<0.05).For the others structural parameters and BMD, however, there were no significant difference between US group and CON group (p>0.05). Conclusion : The LIUS might prevent bone loss and keep bone connectivity in osteoporotic bones. Therefore, the LIUS might prevent effectively the osteoporotic fractures in clinics.