• 제목/요약/키워드: ${\Delta}Y$-system

검색결과 1,289건 처리시간 0.026초

Seismic response of foundation-mat structure subjected to local uplift

  • El Abbas, Nadia;Khamlichi, Abdellatif;Bezzazi, Mohammed
    • Coupled systems mechanics
    • /
    • 제5권4호
    • /
    • pp.285-304
    • /
    • 2016
  • The effects of large rotations and p-delta on the dynamic response of a structure subjected to seismic loading and local uplift of its foundation were analyzed in this work. The structure was modeled by an equivalent flexible mat mounted on a rigid foundation that is supported either by a Winkler soil type or a rigid soil. The equations of motion of the system were derived by taking into account the equilibrium of the coupled foundation-mat system where the structure was idealized as a single-degree-of-freedom. The obtained nonlinear coupled system of ordinary differential equations was integrated by using an adequate numerical scheme. A parametric study was performed then in order to evaluate the maximum response of the system as function of the intensity of the earthquake, the slenderness of the structure, the ratio of the mass of the foundation to the mass of the structure. Three cases were considered: (i) local uplift of foundation under large rotation with the p-delta effect, (ii) local uplift of foundation under large rotation without including the p-delta effect, (iii) local uplift of foundation under small rotation. It was found that, in the considered ranges of parameters and for moderate earthquakes, assuming small rotation of foundation under seismic loading can yield more adverse structural response, while the p-delta effect has almost no effect.

Enhanced Transformation Efficiency of an Anticoagulant Hirudin Gene into Saccharomyces cerevisiae by a Double ${\delta}-Sequence$

  • Kim, Myoung-Dong;Yoo, Young-Je;Rhee, Sang-Ki;Seo, JIn-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권1호
    • /
    • pp.61-64
    • /
    • 2001
  • Delta-integration vectors were constructed for the purpose of achieving homologous integration of the hirudin expression cassette into the chromosome of Saccharomyces cerevisiae. A double $\delta$ system truncated with the unnecessary bacterial genes, and consequently having a reduced insert size for integration, showed a four-fold increase in transformation efficiency at given DNA concentrations, and as a result, the constructed recombinant yeast strain had a 1.3-fold enhancement in hirudin expression level compared with a single $\delta$ system.

  • PDF

A Three-Phase Four-Wire DSTATCOM for Power Quality Improvement

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • 제8권3호
    • /
    • pp.259-267
    • /
    • 2008
  • Power quality improvement in a three-phase four-wire system is achieved using a new topology of DSTATCOM (distribution static compensator) consisting of a star/delta transformer with a tertiary winding and a three-leg VSC (voltage source converter). This new topology of DSTATCOM is proposed for power factor correction or voltage regulation along with harmonic elimination, load balancing and neutral current compensation. A tertiary winding is introduced in each phase for a delta connected secondary in addition to the star-star windings and this delta connected winding is responsible for neutral current compensation. The dynamic performance of the proposed DSTATCOM system is demonstrated using MATLAB with its Simulink and Power System Blockset (PSB) toolboxes under varying loads. The capacitor supported DC bus of the DSTATCOM is regulated to the reference voltage under varying loads.

PID 제어방식에 근거한 퍼지 제어 시스템의 설계 (Design of fuzzy control system based on PID control scheme)

  • 김관준;이철희;남현도
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.404-407
    • /
    • 1993
  • In this paper, a new PID fuzzy controller(FC) is presented. The linguistic control rules of PID FC is separated into two parts : one is e-.DELTA.e part, and the other is .DELTA.$^{2}$e - .DELTA.e part. And then two FCs employing these rule base individually are synthesized. The control input to the process is decided by taking weighted mean of the outputs of two FCs. The proposed PID FC improve the transient response of the system and gives better performance than the conventional PI FC.

  • PDF

PI와 PD의 병렬 구성에 의한 퍼지 PID제어 시스템 (Fuzzy PID control System by Parallel PI and PD Control)

  • 이철희
    • 산업기술연구
    • /
    • 제13권
    • /
    • pp.43-48
    • /
    • 1993
  • In this paper, a new PID fuzzy controller (FC) is presented. The linguistic control rules of PID FC is separated into two parts : one is $e-{\Delta}e$ part, and the other is ${\Delta}^2e-{\Delta}e$ part. And then two FCs employing these rule base indivisually are synthesized. The control input to the process is decided by taking weighted mean of the outputs of two FCs. The proposed PID FC improve the transient response of the system and gives better performance than the conventional PI FC.

  • PDF

화력 발전소 증기 터빈의 자동기동을 위한 주증기 제어 밸브 수명해석 (Service Life Analysis of Control Valve for Automatic Turbine Startup of Thermal Power Plant)

  • 김효진;강용호;신철규;박희성;유봉호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.7-12
    • /
    • 2000
  • The automatic turbine startup system provides turbine control based on thermal stress. During the startup, control system monitors and evaluates main components of turbine using damage mechanism and life assessment. In case of valve chest, the temperature of inner/outer wall is measured by thermo-couples and the safety of these values are evaluated by using allowable ${\Delta}T$ limit curve during the startup. Because allowable ${\Delta}T$ limit curve includes life assessment, it is possible to apply this curve to turbine control system. In this paper, low cycle fatigue damage and combined rupture and low cycle fatigue damage criterion proposed for yielding the allowable ${\Delta}T$ limit curve of CV(control valve) chest. To calculate low cycle fatigue damage, the stress analysis of valve chest has peformed using FEM. Automatic turbine startup to assure service life of CV was achieved using allowable ${\Delta}T$ limit curve.

  • PDF

비접지 DC 급전시스템에서의 Delta-I 지락보호계전 시스템 (Development of Delta-I ground fault Protective Relaying Scheme for DC Traction Power Supply System)

  • 정상기;권삼영;정호성;김주락
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.529-535
    • /
    • 2006
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot identify the faulted region which causes long traffic delays and safety problem to passengers. A new ground fault protective relay scheme, ${\Delta}I$ ground fault protective relay, that can identify the faulted region is presented in this paper. In ${\Delta}I$ ground fault protective relaying scheme, ground fault is detected by 59, overvoltage relay, which operates ground switch installed between the negative bus and the ground. It preliminarily chooses the faulted feeder after comparing the current increases among feeders and trips the corresponding feeder breaker. After some time delay, it then recloses the breaker if it finds the preselected feeder is not the actual faulted feeder. Whether or not the preselected feeder is the actual faulted feeder is determined by checking the breaker trip status in the neighboring substation in the direction of the tripped breaker. If the corresponding breaker in the neighboring substation is also tripped, it finally judges the preselected feeder is actually a faulted feeder. Otherwise it recloses the tripped breaker. Its algorithms is presented and verified by EMTP simulation.

CELP 보코더에서 델타 피치 검색 방법 개선에 대한 연구 (An Algorithm to Reduce the Pitch Computational amount using Modified Delta Searching in CELP Vocoders)

  • 주상규
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2010년도 춘계학술발표논문집 1부
    • /
    • pp.269-272
    • /
    • 2010
  • In this paper, we propose the computation reduction methods of delta pitch search that is used in G.723.1 vocoder. In order to decrease the computational amount in delta pitch search the characteristic of proposed algorithms is as the following. First, scheme to reduce the computation amount in delta pitch search uses NAMDF. Developed the second scheme is the skipping technique of lags in pitch searching by using the threshold value. By doing so, we can reduce the computational amount of pitch searching more than 64% with negligible quality degradation.

  • PDF

${\delta}$ - 연산자를 이용한 강인한 서보 제어기의 설계 (A Design on Robust Servo Controller Using ${\delta}$ - Operator)

  • 황현준;김정택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2602-2604
    • /
    • 2000
  • In this paper, we study robust linear optimal model following servo system in the presence of disturbances and parameter perturbations. A technique to directly design the generalized differential operator based unified control system that covers both differential operator based continuous time and delta operator based discrete time case is presented. The quadratic criterion function for a linear system is used to design the robust unified servo control system. This servo control system is designed by applying a simple genetic algorithm to follow the output of the reference model optimally. The characteristics of the proposed servo system are analysed and simulated to verify the robustness.

  • PDF

유압 서보 모터를 위한 $e-{\Delta}e$ 위상평면을 이용한 이중 퍼지 로직 제어기 설계 (Design of Dual Fuzzy Logic Controller using $e-{\Delta}e$ Phase Plane for Hydraulic Servo Motor)

  • 신위재;문정훈
    • 융합신호처리학회논문지
    • /
    • 제8권3호
    • /
    • pp.222-226
    • /
    • 2007
  • 본 연구에서는 응답의 과도영역에서 특징점의 각 영역과 $e-{\Delta}e$ 위상평면을 이용하여 이중 퍼지룰을 구성하였다. 구성된 퍼지 제어룰은 기본 퍼지제어 룰에 비해 상승시간, 지연시간, 최대오브슈트 등을 줄일 수 있었으며 퍼지 룰의 제안방법은 $e-{\Delta}e$ 위상평면에서 하나의 퍼지룰은 과도영역에서 정상상태오차를 일으키고 다른 퍼지 제어 룰은 정상상태오차를 감소시키고 수렴영역에서 빠르게 수렴하도록 교대로 사용한다. 또한 $e-{\Delta}e$ 위상평면에서의 두 개의 퍼지 룰은 플랜트의 응답 특성에 따라 교체시기를 결정한다. DSP 프로세서를 사용하는 유압서보 모터 제어시스템을 통한 실험의 결과로서 제안된 이중 퍼지 제어 룰은 기본 퍼지 제어 룰에 비해 빠른 상승시간, 정정시간등 양호한 응답을 얻을 수 있음을 확인하였다.

  • PDF