• 제목/요약/키워드: $^{99m}Tc$-MDP bone scan

검색결과 60건 처리시간 0.03초

B형 간염 백신 접종 후 일시적으로 관찰된 $^{99m}Tc$-MDP의 미만성 간 섭취 (Transient Diffuse Hepatic Uptake of $^{99m}Tc$-MDP after Hepatitis B Vaccination)

  • 김현진;박영하;황성수;김상흠;정수교
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권1호
    • /
    • pp.48-50
    • /
    • 2006
  • A 38-year-old female with arthralgia in right elbow joint for 6 months was referred for a bone scan which showed diffuse uptakes of $^{99m}Tc$-MDP in the liver and spleen without hepatosplenomegaly. She had a history of hepatitis B vaccination 3 days ago. These uptakes were disappeared on the follow-up bone scan after 4 months. We suggest this transient diffuse hepatic uptake after vaccination of hepatitis B might be due to aluminum component within the hepatitis B vaccine as adjuvant.

간경변환자에서 복부외상후 일시적으로 관찰된 $^{99m}Tc$-MDP Bone Scan의 비장 섭취 1예 (A Case of with Transient splenic Hot Uptake on $^{99m}Tc$-Methylene Diphosphonate(MDP) Bone Scan Following Blunt Abodominal Trauma with Underlying Liver Cirrhosis)

  • 원종현;김재명;김정한;추길연;박석오;성상규;최대섭;김진승
    • 대한핵의학회지
    • /
    • 제27권2호
    • /
    • pp.309-314
    • /
    • 1993
  • 저자등은 33세 남자 환자에서 검사실 소견과 복부 전산화 단층촬영, 간 신티그라피 및 골주사, 복부 초음파 및 수술소견을 통해 알콜성 및 C형 간염에 의한 간경화를 동반한 환자가 교통사고로 복부 외상에 의한 간하부열상을 받아 복강내출혈로 입원한 환자에서 일시적으로 골주사소견에서 비장에 섭취를 보이는 것이 복부 비장의 잠재적 외상으로 인한 것으로 사료되며, 비장 비대 외에는 특이소견이 보이지 않으며 기전이 명확하지 않은 골주사상 비장섭취를 보인 1예를 경험하였기에 문헌 고찰과 함께 보고하는 바이다.

  • PDF

$Al^{3+}$ 존재가 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 미치는 영향 (Effect of $Al^{3+}$ on Labeling Efficiency and Biodistribution of $^{99m}Tc$-MDP)

  • 장영수;정재민;김영주;곽철은;이동수;정준기;이명철;고창순
    • 대한핵의학회지
    • /
    • 제30권3호
    • /
    • pp.361-366
    • /
    • 1996
  • 본 연구는 $^{99}Mo-^{99m}Tc$ 발생기시스템에서 용출될 수 있는 알루미늄이 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 어떤 영향을 미치는지를 보기 위한 실험이다. 알루미늄이온 농도 ($0-62.5{\mu}g/ml$)를 증가시킬수록 $^{99m}Tc$-MDP의 표지효율은 급격히 떨어지며 상대적으로 $^{99m}Tc$ pertechnetate와 hydrolyzed reduced $^{99m}Tc$ 부위의 상대적인 양은 증가되었다. $^{99m}Tc$-MDP는 알루미늄 존재하에서도 상당히 안정하였다. 알루미늄에 의해 $^{99m}Tc$-MDP 반응물이 교질을 형성하는지를 보기 위해 $0.22{\mu}m$ syringe filter로 여과한 액은 여과하지 않은 것과 유의한 차이를 나타내지 않았다. 마우스에 대한 생체내 분포실험은 알루미늄에 의해 $^{99m}Tc$-MDP의 표지효율이 떨어지고 $^{99m}Tc$ pertechnetate의 증가로 인해 혈액과 심장의 흡수는 증가하나 간과 뼈의 흡수는 별다른 차이를 나타내지 않았다. 랫트의 골스캔에서는 $5{\mu}g/ml$의 알루미늄농도에서는 영상의 차이가 없으나 $10{\mu}g/ml$ 농도에서는 하복부의 흡수가 높게 나타났다. 이상의 결과는 알루미늄이 $^{99}Mo-^{99m}Tc$ 발생기시스템 칼럼의 용출제한량인 $10{\mu}g/ml$이하에서도 MDP의 표지효율에 상당한 영향을 미칠 수 있다는 것을 보여준다. 따라서$^{99m}Tc$-MDP 골스캔시 연조직에의 흡수가 보이는 경우에도 방사성의약품의 방사화학적 순도에 대한 정도관리가 충분히 이루어 졌다면 $^{99}Mo-^{99m}Tc$ 발생기시스템에서 용출되는 알루미늄에 의한 영향은 배제될 수 있다.

  • PDF

뼈 스캔상 우연히 발견된 그레이브스 갑상선기능항진증에서 갑상선의 섭취증가 (Incidental Visualization of Thyroid Gland on Bone Scan Caused by Graves' Hyperthyroidism)

  • 손명희;정환정;김동욱;임석태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권2호
    • /
    • pp.154-155
    • /
    • 2009
  • A 45-year-old man presented with fatigue and weight loss underwent a Tc-99m MDP bone scan because of increased serum alkaline phosphatase. Delayed images at 4 hours demonstrated diffuse increased activity throughout both lobes of the thyroid in the absence of activity of the stomach and salivary glands. Thyroid laboratory indices and a Tc-99m pertechnetate thyroid scan suggested Graves' hyperthyroidism.

$^{99m}Technetium-methylene$ Diphosphonate의 전신 골격주사술을 이용한 관절염의 핵의학적 진단 (Scintigraphic Detection of Adjuvant-induced Arthritis in Rats Using $^{99m}Technetium-methylene$ Diphosphonate)

  • 강성수;궁성수;배춘식;최석화
    • 한국임상수의학회지
    • /
    • 제18권2호
    • /
    • pp.133-138
    • /
    • 2001
  • 본 연구는 랫드에서 Freund's complete adjuvant를 랫드의 후지에 투여하여 인의적으로 유발된 관절염을 진단하기 위한 방법으로 $^{99m}Technetium-MDP (^{99m}Tc_MDP$)을 이용한 골 스캔의 임상적 의의를 찾고자 하였다. 성숙 Sprague-Dawley 암컷 랫드를 대조군과 실험군으로 분리하고, 골의 스캔은 0.05mCi의 $^{99m}Tc_MDP$를 정맥 주사하여 3시간 후에 전신 영상을 얻었다. 골의 스캔과 방사선학적 평가를 비교한 겨과 관절염 유발 7일 후부터 관절염의 병변이 관찰되었지만, 방사선학적 소견에서는 14일 후부터 병변이 관찰되었다. 골의 스캔에서 관절염 유발 7일 후에 유의적으로 골의 이상적 섭취 증각가 관찰되었고(p<0.05), 21일 후에는 전지와 후지의 모든 부위에서 골의 이상적 섭취 증가가 관찰되었지만, 방사선학적 소견에서는 후지에서만 병변 부위가 관찰되었다. 이상의 결과에서 $^{99m}Tc_MDP$을 이용한 골의 스캔은 류마티스 관절염을 임상적으로 진단하는데 방사선학적 진단보다 효과적인 방법임을 알 수가 있었고, 골의 스캔은 류마티스 관절염을 초기에 진단하는데 유효한 진단방법임을 확인하였다.

  • PDF

악성종양에서 골수면역신티그라피를 이용한 골수전이의 평가 : $^{99m}Tc$-MDP 뼈스캔과의 비교 (Bone Marrow Immunoscintigraphy for the Detection of Skeletal Metastasis in Malignant Tumors: A Comparison with $^{99m}Tc$-MDP Bone Scan)

  • 이경한;최창운;방영주;정준기;정홍근;이명철;김병국;김노경;고창순
    • 대한핵의학회지
    • /
    • 제28권1호
    • /
    • pp.89-97
    • /
    • 1994
  • Although bone scan is a highly sensitive test for detecting bone metastasis, its findings are often limited in specificity and cannot be used for assessing the bone marrow. Bone marrow scintigraphy may provide useful information but previous experience with radiolabelled colloid has been disappointing. Recently, $^{99m}Tc$ labeled anti-granulocyte monoclonal antibody (anti-NCA-95 MAb) has been introduced as a new bone marrow imaging agent. To evaluate the usefulness of $^{99m}Tc$ anti-NCA MAb bone marrow scans for detecting skeletal metastasis, bone marrow scans of 44 malignant tumor patients were evaluated and compared with bone scan findings. Bone scan showed abnormal lesions in 26(59%) cases, and 18 of these patients also had an abnormal bone marrow scan. Seven of the 8 patients who had normal bone marrow scan despite bone scan lesions were confirmed to be free from metastasis. There was one case with a marrow defect despite normal bone scan but the presence of metastasis was not determined due to loss of follow up. Bone scan demonstrated a total of 64 lesions while bone marrow scan showed 38 lesions. Fifty percent (32/64) of the bone scan lesions had matching marrow defects while the remaining 50% did not. Most of these non matched lesions were suggested to be nonspecific lesions such as rib fractures or degenerative change. Meanwhile bone marrow scan was able to detect 6 new lesions not detected by bone scan, bit metastasis in each lesion was not confirmed. Bone marrow scan was also helpful in assessing equivocal bone scan lesions to be of metastatic nature in 10 patients by demonstrating a matched marrow defect. Thus $^{99m}Tc$ anti-NCA MAb bone marrow scan can help exclude metastasis in patients with nonspecific bone scan lesions and may be able to detect metastatic lesions not seen with bone scan. It appears useful as a complementary study to bone scan in evaluating malignant tumor patients.

  • PDF

이중에너지 X선 흡수법을 이용한 골밀도 측정시 99mTc-MDP 투여 전·후 측정값의 변화 (Change in the Measured Value at 99mTc-MDP Administration before and after Bone Density Measurement using the Dual Energy X-ray Absorptiometry)

  • 강용길;원도연;정홍문
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.43-48
    • /
    • 2017
  • 최근 동위원소를 이용한 뼈 스캔 (Bone Scan)검사 후 골밀도 (BMD; Bone Mineral Density)검사를 당일검사로 병행한 경우 이로 인한 골밀도 측정값에 오차 발생 가능성이 제기되고 있으나 방사성의약품 표지화합물 투여 후 이중에너지 X선을 이용한 골밀도 측정값 변화에 대한 임상적 자료가 미비하여 핵의학 체내검사 후 당일 골다공증 검사의 측정값에 대한 논란의 소지가 있다. 따라서 동위원소 표지화합물인 $^{99m}Tc-MDP$가 골밀도 측정값에 영향을 미치는지 임상적 측면에서 실험하였다. 실험에 참가한 대상자의 평균 나이는 $35.17{\pm}9.45$세로 실험 대상자 17명 중 대사성 질환과 골밀도 측정에 영향을 줄 수 있는 허리뼈 압박골절 및 몸쪽 넓적다리뼈 골절이 있는 자를 제외한 12명 중 정상 골밀도 T-scores>-1.0의 환자 6명을 대상으로 $^{99m}Tc-MDP$ 투여 전 후 측정값을 분석한 결과 허리뼈에서 전 후 각각 평균 $0.975{\pm}0.084g/cm^2$, $0.966{\pm}0.078g/cm^2$으로 $0.009g/cm^2$ 증가, 우측 몸쪽 넓적다리뼈에서는 전 후 각각 평균 $0.909{\pm}0.078g/cm^2$, $0.913{\pm}0.086g/cm^2$으로 $0.004g/cm^2$ 감소, 좌측 몸쪽 넓적다리뼈에서는 각각 평균 $0.887{\pm}0.099g/cm^2$, $0.881{\pm}0.103g/cm^2$으로 $0.007g/cm^2$의 증가를 보여 몸쪽 넓적다리뼈 보다 허리뼈에서 더 큰 골밀도 변화를 보여주었다. 그러나 허리뼈와 몸쪽 넓적다리뼈 전체에서 전 후 변화 평균은 $0.0038{\pm}0.014g/cm^2$으로 골밀도 측정값에 유의한 영향이 없음을 알 수 있으며, 또한 두 실험간 전체 상관계수는 0.987으로 방사성동위원소 표지화합물인 $^{99m}Tc-MDP$ 투여가 골밀도 측정값에 영향을 주지 않았다. 따라서 140 keV의 감마선 에너지를 방출하는 테크네슘 표지화합물을 이용한 뼈 스캔검사 후 골밀도 측정값에 유의한 영향을 미치지 않음을 확인하였다. 그러나 핵의학적 체내검사와 골다공증 검사를 당일로 검사함으로 인한 환자의 피폭을 고려한다면 시간 간격을 두고 검사를 시행하는 것이 좋을 것으로 사료된다.

$^{99m}Tc$-MDP 유방 스캔은 유방 종괴의 감별진단에 임상적인 유용성이 있는가? (Is $^{99m}Tc$-MDP Mammoscintigraphy Useful in Patients with Breast Mass Lesions?)

  • 박석건;이연희;류진우;유선미
    • 대한핵의학회지
    • /
    • 제32권2호
    • /
    • pp.151-160
    • /
    • 1998
  • 목적: 유방 종괴의 악성과 양성종양의 감별진단에 있어서 $^{99m}Tc$-MDP 유방촬영의 임상적의의를 알고자 하였다. 대상 및 방법: 34명의 여자 환자에서 $^{99m}Tc$-MDP를 이용한 유방스캔을 하고, 그 결과를 필름 유방촬영 및 조직생검 결과와 비교하였다. $^{99m}Tc$-MDP의 섭취는 양측 유방에 대칭적으로 섭취가 없는 경우(배경과 같은 정도)를 grade 0, 섭취가 있으나 양측 유방에 전반적으로 대칭적으로 있을 때는 grade 1, 비대칭적인 섭취가 있으나 희미하거나 의심스러운 경우는 grade 2, 비대칭적으로 한쪽에 국소적인 열소가 있는 경우를 grade 3라고 하였다. 결과: 정상 환자들의 $^{99m}Tc$-MDP유방촬영 소견은, 양쪽 유방이 대칭적이면서 균일하게 거의 배경 정도의 방사능 섭취를 보이거나, 유방의 실질 전체에 걸쳐서 미만성으로 섭취를 보이며, 국소적인 $^{99m}Tc$-MDP의 섭취를 보인 예는 한 예도 없었다. 악성종양환자 7명 중 6명은 grade 2(2명)와 grade 3(4명)의 소견을 보였다. 1명은 스캔 상 grade 1으로 나타났다. 양성 종양환자 6명에서는 grade 3이 3명, grade 1이 3명이었다 섬유낭포성질환에서는 7명 중 1명에서만 grade 3으로 종괴처럼 보였고 grade 2 가 3명, grade 1이 2명, 0가 1명이었다. Lesion/Back-ground Ratio 는 정상인 경우 $1.05{\pm}0.20$($average{\pm}1sd$), 섬유낭포성질환의 경우 $1.20{\pm}0.36$, 양성 종양의 경우는 $1.68{\pm}0.09$, 악성 종양의 경우는 $1.66{\pm}0.62$였다. 정상 및 섬유낭포성질환은 종양과 차이가 있었지만, 양성종양과 악성종양은 유의한 차이가 없었다. 결론: $^{99m}Tc$-MDP 유방스캔은 Piccolo 등의 보고와는 달리, 유방종괴를 호소하는 환자에서 고형종괴의 발견에는 무리가 없으나, 일상적으로 양성과 악성을 구분하기 위하여 사용하기에는 부족할 것으로 결론을 내렸다. 그러나 유방암 환자에서 전신 골스캔을 시행하면서 2상 영상(2 phase image)의 개념으로 초기 유방영상을 얻는 등의 방법으로 활용을 할 수는 있을 것으로 생각하였다.

  • PDF

원발성 유방암에서 질병병기 분류 및 추적검사 $^{99m}Tc-MDP$ 골 신티그램의 의의 ($^{99m}Tc$ MDP-Bone Scintigraphy for Preoperative and Follow up Assessment in Primary Breast Cancer)

  • 이강욱;방영주;정준기;이명철;조보연;김노경;고창순
    • 대한핵의학회지
    • /
    • 제22권1호
    • /
    • pp.59-64
    • /
    • 1988
  • Because carcinoma of breast is known to readily metastasize to the bone, early detection of metastasis spread is very important. Two hundred thirty four consecutive patients who had $^{99m}Tc-MDP$ bone scans prior to treatment and during the follow up period were studied retrospectively to determine the contribution of the scans to staging, treatment and follow up examination between Jan. 1980 and Apr. 1987 in Seoul National University Hospital. 1) Positive bone scan rates in initial clinical stage I, II, III and IV were 0%, 4%, 14% and 53%, respectively. 2) The higher clinical stage is, the more cumulative risk of conversion to positive bone scan is during the same follow up period. 3) Conversion rate to positive bone scan in patients with lymph node metastasis is higher (50%) than those without metastasis (18%) (P < 0.001). We concluded that the bone scan in primary breast cancer was very useful to evaluate initial clinical stage and to perform the follow up examination.

  • PDF