• Title/Summary/Keyword: $^{60}Co\{\gamma}-ray$

Search Result 274, Processing Time 0.022 seconds

Investigation of gamma radiation shielding capability of two clay materials

  • Olukotun, S.F.;Gbenu, S.T.;Ibitoye, F.I.;Oladejo, O.F.;Shittu, H.O.;Fasasi, M.K.;Balogun, F.A.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.957-962
    • /
    • 2018
  • The gamma radiation shielding capability (GRSC) of two clay-materials (Ball clay and Kaolin)of Southwestern Nigeria ($7.49^{\circ}N$, $4.55^{\circ}E$) have been investigated by determine theoretically and experimentally the mass attenuation coefficient, ${\mu}/{\rho}(cm^2g^{-1})$ of the clay materials at photon energies of 609.31, 1120.29, 1173.20, 1238.11, 1332.50 and 1764.49 keV emitted from $^{214}Bi$ ore and $^{60}Co$ point source. The mass attenuation coefficients were theoretically evaluated using the elemental compositions of the clay-materials obtained by Particle-Induced X-ray Emission (PIXE) elemental analysis technique as input data for WinXCom software. While gamma ray transmission experiment using Hyper Pure Germanium (HPGe) spectrometer detector to experimentally determine the mass attenuation coefficients, ${\mu}/{\rho}(cm^2g^{-1})$ of the samples. The experimental results are in good agreement with the theoretical calculations of WinXCom software. Linear attenuation coefficient (${\mu}$), half value layer (HVL) and mean free path (MFP) were also evaluated using the obtained ${\mu}/{\rho}$ values for the investigated samples. The GRSC of the selected clay-materials have been compared with other studied shielding materials. The cognizance of various factors such as availability, thermo-chemical stability and water retaining ability by the clay-samples can be analyzed for efficacy of the material for their GRSC.

Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.

Radiation induced synthesis of (gelatin-co-PVA)-g-poly (AAc) copolymer as wound dressing material

  • Kaur, Inderjeet;Bhati, Pooja;Sharma, Sushma
    • Advances in materials Research
    • /
    • v.3 no.4
    • /
    • pp.183-197
    • /
    • 2014
  • Copolymers of gelatin and poly (vinyl alcohol), (PVA) grafted by acrylic acid (AAc) with excellent water absorption and retention abilities under neutral conditions were successfully synthesized using $^{60}Co$ gamma radiations in presence of ammonium persulphate (APS), as water soluble initiator and sodium bicarbonate ($NaHCO_3$) as foaming agent. The optimum synthesis conditions pertaining to maximum swelling percentage were evaluated as a function of gelatin/PVA ratio, amount of water, concentration of APS, $NaHCO_3$, monomer concentration and total irradiation dose. Maximum percent swelling (1694.59%) of the copolymer, gelatin-co-PVA, was obtained at optimum $[APS]=2.92{\times}10^{-1}mol/L$, $[NaHCO_3]=7.94{\times}10^{-2}mol/L$ and 1.5 mL of water at total dose of 31.104 kGy while in case of grafted copolymer, (gelatin-co-PVA)-g-poly(AAc), maximum percent swelling (560.86%) was obtained using $8.014{\times}10^{-1}mol/L$ of AAc in 9 mL water with 31.104 kGy preirradiation dose. The pristine and grafted copolymers were characterized by Fourier Transform Infrared Spectroscopy (FTIR), Scanning electron Microscopy (SEM), Thermal gravimetric analysis (TGA) and X-Ray Diffraction (XRD) methods. The copolymers loaded with an antiseptic, Povidone, were used as wound dressing materials for wounded gastrocnemius muscle of mice and the results exhibit that (gelatin-co-PVA)-g-poly (AAc) copolymer is a potent wound dressing material as compared to the copolymer.

An Immunohistochemical Study of Pheasant Testis in Active, Inactive and Damaged States (번식기, 비번식기 및 손상상태에 따른 한국꿩 고환의 면역조기화학적 연구)

  • ;Karl-heinz Wrobel
    • Korean Journal of Poultry Science
    • /
    • v.24 no.3
    • /
    • pp.107-116
    • /
    • 1997
  • In order to achieve optimal reproductive performance, reliable morphological and physiological basic data on the reproductive organs are desirable. Adult male Korean ring-necked pheasant in inactive(mid of January) and active state (end of April) were used in this study. In addition, five active state pheasants were received a single dose of 60Co-ray 500 rads each to damage the testes. The objective of this study was to investigate the distribution pattern of protein gene product (PGP) 9.5 and ${\alpha}$-tubulin in the pheasant testes of the active, inactive and ${\gamma}$-ray irradiated active states. The results obtained were summarized as follows 1. The seminiferous tubules collected in inactive states( mid of Jan) showed narrow lumen, and the spermatogonia and the Sertoli cell were well preserved. The PGP 9.5 immunoreactivity of these tubules showed a positive reaction in paranucleus area of the spermatogonia, and a positive reaction in a small number of the Leydig cells in the interstitium of the seminiferous tubules. 2. The seminiferous tubules were dilated in active state(end of April) as compared with the inactive state. The PGP 9.5 reactivity in these tubules showed a positive reaction in many Leydig cells in the interstitium of the seminiferous tubules, and the testes of ${\gamma}$-ray irradiated group showed partially weak reaction in the interstitium of the seminiferous tubules. 3. The ${\alpha}$-tubulin reactivity in the seminiferous tubules of the inactive testes was strongly positive in the cytoplasmic process of the Sertoli cell from the basal stem region to the apical ex-tension. From the broad part of the stem region to the luminal space, the active testes showed a strong positive reaction. The ${\gamma}$-ray irradiated groups showed diminished reaction in the basal region.

  • PDF

Effect of Composition of γ-Al2O3/SiO2 Mixed Support on Fischer-Tropsch Synthesis with Iron Catalyst (철 기반 촉매의 Fischer-Tropsch 합성에서 γ-Al2O3/SiO2 혼합 지지체 조성의 영향)

  • Min, Seon Ki;No, Seong-Rae;You, Seong-sik
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.436-442
    • /
    • 2017
  • Fischer-Tropsch synthesis is the technology of converting a syngas (CO+$H_2$) derived from such as coal, natural gas and biomass into a hydrocarbon using a catalyst. The catalyst used in the Fischer-Tropsch synthesis consists of active metal, promoter and support. The types of these components and composition affect the reaction activity and product selectivity. In this study, we manufactured an iron catalyst using ${\gamma}-Al_2O_3/SiO_2$ mixed support (100/0 wt%, 75/25 wt%, 50/50 wt%, 25/75 wt%, 0/100 wt%) by an impregnation method to investigate how the composition of ${\gamma}-Al_2O_3/SiO_2$ mixed support effects on the reaction activity and product selectivity. The physical properties of catalyst were analyzed by $N_2$ physical adsorption and X-Ray diffraction method. The Fischer-Tropsch synthesis was conducted at $300^{\circ}C$, 20bar in a fixed bed reactor for 60h. According to the results of the $N_2$ physical adsorption analysis, the BET surface area decreases as the composition of ${\gamma}-Al_2O_3$ decreases, and the pore volume and pore average diameter increase as the composition of ${\gamma}-Al_2O_3$ decreases except for the composition of ${\gamma}-Al_2O_3/SiO_2$ of 50/50 wt%. By the results of the X-Ray diffraction analysis, the particle size of ${\alpha}-Fe_2O_3$ decreases as the composition of ${\gamma}-Al_2O_3$ decreases. As a result of the Fischer-Tropsch synthesis, the CO conversion decreases as the composition of ${\gamma}-Al_2O_3$ decreases, and the selectivity of C1-C4 decreases until the composition of ${\gamma}-Al_2O_3$ was 25 wt%. In contrast, the selectivity of C5+ increases until the composition of ${\gamma}-Al_2O_3$ is 25 wt%.

A Monte Carlo Study of Dose Enhancement according to the Enhancement Agents (몬테칼로 기법을 이용한 방사선 선량증가 물질에 따른 선량증가 효과 평가)

  • Kim, Jung-Hoon;Kim, Chang-Soo;Hwang, Chulhwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.93-99
    • /
    • 2017
  • Dose enhancement effects at megavoltage (MV) X and ${\gamma}-ray$ energies, and the effects of different energy levels on incident energy, dose enhancement agents, and concentrations were analyzed using Monte Carlo simulations. Gold, gadolinium, Iodine, and iron oxide ($Fe_2O_3$) were compared as dose enhancement agents. For incident energy, 4, 6, 10 and 15 MV X-ray spectra produced by a linear accelerator and a Co-60 ${\gamma}-ray$ were used. The dose enhancement factor (DEF) was calculated using an ICRU Slab phantom for concentrations of 7, 18, and 30 mg/g. The DEF was higher at higher concentrations of dose enhancement agents and at lower incident energies. The calculated DEF ranged from 1.035 to 1.079, and dose enhancement effects were highest for iron oxide, followed by iodine, gadolinium, and gold. Thus, this study contributes to improving the therapeutic ratio by delivering larger doses of radiation to tumor volume, and provides data to support further in vivo and in vitro studies.

${\gamma}-ray$ Effects on Steroid Hormone Concentration of Mouse Ovarian Follicles (생쥐의 난소내 스테로이드호르몬 농도에 미치는 ${\gamma}$-선의 영향)

  • Lee, Young-Keun;Kim, Jin-Kyu;Yoon, Yong-Dal
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.3
    • /
    • pp.179-188
    • /
    • 1994
  • Mice were whole body irradiated with dose of 2.88Gy and 7.2Gy(Co-60) in order to observe the morphological and functional changes in radio sensitive mouse ovary. Microtechnical sectionates of $7{\mu}m$ thickness from ovary were made for light microscopy and concentrations of progesterone, testosterone and estradiol in ovarian homogenates were analyzed by radioimmunoassay. Gamma radiation resulted in the increase of atretic ratio of preantral and antral follicles, the increase of progesterone concentration in ovarian homogenates, and the low level of testosterone and estradiol. It is suggested that radiation protect the activity of $3{\beta}-HSD$(hydroxysteroid dehydrogenase) and isomerase in the follicular theca cell followed by low level of testosterone and estradiol and thereafter follicular atresia proceed.

  • PDF

Determination of Radiolysis Produce of DHOA by GC/MS (GC/MS를 이용한 DHOA의 방사선 분해생성물 분석)

  • Yang, Han-Beom;Lee, Eil-Hee;Lim, Jae-Kwan;Chung, Dong-Yong;Kim, Kwang-Wook;Kim, Jong-Seung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • Dihexyloctanamide(DHOA) was used as an extractant or phase modifier with the diamide extractants in a solvent extraction process for a radioactive liquid waste treatment. The degradation compounds of the DHOA extractant, irradiated with $^{60}Co$ gamma ray, were octanoic acid and dihexylamine which are identified by a Fourier transform infrared(FT-IR) and gas chromatograph/mass spectrometer(GC/MS) analysis, and determined by the GC/MS with selected ion monitoring(SIM) mode. Retention behavior of octanoic acid, tridecane (internal standard) and dihexylamine in total ion chromatogram (TIC) were 8.65 min., 9.79 min., and 10.27 min., respectively. With increasing the absorbed dose of the $\gamma$-ray irradiated DHOA, the concentration of octanoic acid was decreased and that of dihexylamine was increased.

  • PDF

The Analysis of Total Ionizing Dose Effects on Analog-to-Digital Converter for Space Application (우주용 ADC의 누적방사선량 영향 분석)

  • Kim, Tae-Hyo;Lee, Hee-Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.85-90
    • /
    • 2013
  • In this paper, 6bit SAR ADC tolerant to ionizing radiation is presented. Radiation tolerance is achieved by using the Dummy Gate Assisted (DGA) MOSFET which was proposed to suppress the leakage current induced by ionizing radiation and its comparing sample is designed with the conventional MOSFET. The designed ADC consists of binary capacitor DAC, dynamic latch comparator, and digital logic and was fabricated using a standard 0.35um CMOS process. Irradiation was performed by Co-60 gamma ray. After the irradiation, ADC designed with the conventional MOSFET did not operate properly. On the contrary, ADC designed with the DGA MOSFET showed a little parametric degradation of which DNL was increased from 0.7LSB to 2.0LSB and INL was increased from 1.8LSB to 3.2LSB. In spite of its parametric degradation, analog to digital conversion in the ADC with DGA MOSFET was found to be possible.

Synthesis of DMDBTDMA and determination of radiolysis products by GC/MS (DMDBTDMA의 합성 및 방사선 분해산물의 GC/MS 분석)

  • Yang, Han-Beom;Lee, Eil-Hee;Park, Gyo-Beom
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.403-411
    • /
    • 2008
  • Dimethyldibutyltetradecylmalonamide (DMDBTDMA) extractant was used in a solvent extraction process for a radioactive liquid waste treatment. For the study of radiolysis phenomena, DMDBTDMA was synthesized and the degradation compounds (n-methylbutylamine, tetradecane, 1-tetradecanol) in the DMDBTDMA extractant, irradiated with $^{60}Co$ gamma ray, were identified and determined as radiolysis products by a Fourier transform infrared (FT-IR), gas chromatograph/mass spectrometer (GC/MS) analysis and GC/MS with selected ion monitoring (SIM) mode. Retention behavior of n-methylbutylamine, n-dodecane, tetradecane and 1-tetradecanol in the total ion chromatogram with the standard materials and n-dodecane as the internal standard (ISTD) were 2.35 min., 8.83 min., 10.68 min. and 12.75 min., respectively. In the case of tetradecane, there was a linear relationship between the concentration of the tetradecane and the absorbed dose of the ${\gamma}$-ray irradiated DMDBTDMA.