• Title/Summary/Keyword: $^{252}Cf$

Search Result 72, Processing Time 0.033 seconds

Neutron Dose Response of Tradescantia Stamen Hair Pink Mutations and RBE (자주달개비 수술털 분홍돌연변이의 중성자 선량반응과 RBE)

  • Kim, Jin-Kyu;Kim, Won-Rok
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.17-23
    • /
    • 1998
  • Dose response relationships for one of biological end-points (gene mutation) in somatic cells of Tradescantia 4430 clones were studied using neutrons coming out of a californium-252 isotopic source. And the relative biological effectiveness (RBE) of neutrons in relation to X-rays in the induction of TSH pink mutations was assessed. Inflorescences were irradiated with X-ray from X-ray generator and neutrons from $^{252}Cf$ source. Irradiated cuttings were incubated with aeration in neutrient solution under the controlled condition. For more than 4 weeks after irradiation cell mutations were scored. Pink mutation frequencies were calculated from the pooled data for the peak interval (days 6 to 13 post-irradiation). Somatic cell mutations in TSH showed linear dose response relationships in the range of neutron doses available for the experiment. The RBE values estimated for neutrons in relation to X-rays were in the range 3.1 to 6.8, which were much lower than normally recognized value.

  • PDF

성토다짐의 밀도 및 수분 측정에 관한 연구

  • 김기준
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.38-46
    • /
    • 2002
  • 본 연구에서는 성토 다짐용 밀도 및 수분의 측정을 위하여 중성자 검출기는 2개 이상 그리고 감마선 검출기는 5개 이상 사용하여 함을 알 수 있었고, 또한 방사능 대비 방사선 방출수가 다른 선원에 비하여 우수한 Co-60 감마선원과 Cf-252 중성자 선원을 본 계기에 이용하는 것이 정밀도를 향상시키기 위하여 유리하다는 것을 알 수 있었다. 본 연구에서 설계하고 제작한 성토 다짐용관리용 밀도 및 수분 함량 측정기는 국내의 도로 공사 현장에서 성토의 다짐관리를 위하여 이용될 수 있을것으로 사료된다.

  • PDF

Analysis of Rainfall-Runoff Characteristics on Bias Correction Method of Climate Change Scenarios (기후변화 시나리오 편의보정 기법에 따른 강우-유출 특성 분석)

  • Kum, Donghyuk;Park, Younsik;Jung, Young Hun;Shin, Min Hwan;Ryu, Jichul;Park, Ji Hyung;Yang, Jae E;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.241-252
    • /
    • 2015
  • Runoff behaviors by five bias correction methods were analyzed, which were Change Factor methods using past observed and estimated data by the estimation scenario with average annual calibration factor (CF_Y) or with average monthly calibration factor (CF_M), Quantile Mapping methods using past observed and estimated data considering cumulative distribution function for entire estimated data period (QM_E) or for dry and rainy season (QM_P), and Integrated method of CF_M+QM_E(CQ). The peak flow by CF_M and QM_P were twice as large as the measured peak flow, it was concluded that QM_P method has large uncertainty in monthly runoff estimation since the maximum precipitation by QM_P provided much difference to the other methods. The CQ method provided the precipitation amount, distribution, and frequency of the smallest differences to the observed data, compared to the other four methods. And the CQ method provided the rainfall-runoff behavior corresponding to the carbon dioxide emission scenario of SRES A1B. Climate change scenario with bias correction still contained uncertainty in accurate climate data generation. Therefore it is required to consider the trend of observed precipitation and the characteristics of bias correction methods so that the generated precipitation can be used properly in water resource management plan establishment.

Effects of Combined Irradiation of Neutrons and ${\gamma}$-Rays on the Pink Mutation Frequencies in Tradescantia (중성자와 감마선 중복 조사가 자주달재비 분홍돌연변이율에 미치는 영향)

  • Kim, Jin-Kyu;Lee, Young-Keun;Kim, Jae-Sung;Shin, Hae-Shick;Hyun, Soung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.67-73
    • /
    • 2000
  • The effects of combined irradiation of neutrons and ${\gamma}$-rays were analysed by means of Tradescantia stamen hair (TSH) assay. Potted plants were irradiated with $0{\sim}2$ Gy of ${\gamma}$-rays. For the combined treatments, the plants were irradiated with neutrons from $^{252}Cf$ 24 hours before or after ${\gamma}$-irradiation. The slopes of dose-response curves were 5.98, 6.17 and 7.48, in ${\gamma}$-rays, ${\gamma}$-rays+neutrons, and neutrons+${\gamma}$ -rays irradiated groups, respectively. The biological efficacy of radiations in the induction of pink mutations increased by 25% in neutrons+${\gamma}$-rays irradiated group, while it increased by 12% in ${\gamma}$-rays+neutrons irradiated group. The combined irradiation with two kinds of radiations results in the different efficacy of radiation depending on the order of irradiations, which is of great importance in the related fields such as sterilization and radiotherapy.

  • PDF

Determination of Microdosimetric Quantities of Several Neutron Calibration Fields at KAERI

  • Kim, B.H.;Kim, J.S.;Kim, J.L.;Chang, S.Y.;Cho, G.;McDonald, J.C.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.327-335
    • /
    • 2003
  • The commercially available neutron survey meter, the REM500, which uses a tissue equivalent proportional counter (TEPC) and the self-constructed TEPC were used to determine the microdosimetric quantities of several neutron calibration fields at Korea Atomic Energy Research Institute (KAERI). Microdosimetric spectra, absorbed dose, dose equivalent as well as quality factor were derived and compared with several neutron fields which were produced by using the shadow objects to make neutron scattered and being used as a kind of realistic neutron calibration fields at KAERI. The response of REM500 as a function of mean energy was evaluated with these neutron fields using the counts measured and the predetermined reference value. The response of the self-made TEPC and the REM500 was compared using one of the neutron calibration filelds of a $^{252}Cf$ source. The reference quantities of scattered neutron calibration fields were determined using a Bonner Sphere (BS). The value of frequency-mean lineal energy, dose-mean lineal energy and quality factor of two $^{252}Cf$ sources (unmoderated and $D_2O$ moderated) were determined to check the differences in the reference neutron fields between KAERI and Pacific Northwest National Laboratory (PNNL, USA) and the results were in good agreement within 1%. It means that there is no big difference in dosimetric quantifies of neutron calibration fields of two laboratories.

Characterization of a CLYC Detector and Validation of the Monte Carlo Simulation by Measurement Experiments

  • Kim, Hyun Suk;Smith, Martin B.;Koslowsky, Martin R.;Kwak, Sung-Woo;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.48-55
    • /
    • 2017
  • Background: Simultaneous detection of neutrons and gamma rays have become much more practicable, by taking advantage of good gamma-ray discrimination properties using pulse shape discrimination (PSD) technique. Recently, we introduced a commercial CLYC system in Korea, and performed an initial characterization and simulation studies for the CLYC detector system to provide references for the future implementation of the dual-mode scintillator system in various studies and applications. Materials and Methods: We evaluated a CLYC detector with 95% $^6Li$ enrichment using various gamma-ray sources and a $^{252}Cf$ neutron source, with validation of our Monte Carlo simulation results via measurement experiments. Absolute full-energy peak efficiency values were calculated for gamma-ray sources and neutron source using MCNP6 and compared with measurement experiments of the calibration sources. In addition, behavioral characteristics of neutrons were validated by comparing simulations and experiments on neutron moderation with various polyethylene (PE) moderator thicknesses. Results and Discussion: Both results showed good agreements in overall characteristics of the gamma and neutron detection efficiencies, with consistent ~20% discrepancy. Furthermore, moderation of neutrons emitted from $^{252}Cf$ showed similarities between the simulation and the experiment, in terms of their relative ratios depending on the thickness of the PE moderator. Conclusion: A CLYC detector system was characterized for its energy resolution and detection efficiency, and Monte Carlo simulations on the detector system was validated experimentally. Validation of the simulation results in overall trend of the CLYC detector behavior will provide the fundamental basis and validity of follow-up Monte Carlo simulation studies for the development of our dual-particle imager using a rotational modulation collimator.

The system design for contents measurement of density and moisture in compaction (성토의 밀도 및 수분 함량을 측정하기 위한 시스템 설계)

  • 김기준
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.7 no.4
    • /
    • pp.37-45
    • /
    • 2002
  • In this study, to measure the density and moisture of compaction, it is designed to use the 2 neutron and 5 gamma-ray detectors. Also, it can be know that Co-60 gamma-ray and Cf-252 neutron source are more useful for this system, because discharge of radiation are better than other sources. They are more profitable to improve their accuracy. Especially, to remove the interference of their reciprocal action between neutron and gamma-ray detectors it is designed shield materials with lead between 2 neutron and 5 gamma-ray detectors each other. It is performed the optimal design to shield under the suggested values completely. Because this system will use portable, so decrease of their weight are so important. For this reason, it can be decrease their weight of 5.2[kg] with shield material between each detectors and it can be think mote easy to carry and use on the industrial Spot.

  • PDF

Assembly Neutron Moderation System for BNCT Based on a 252Cf Neutron Source

  • Gheisari, Rouhollah;Mohammadi, Habib
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.101-105
    • /
    • 2018
  • In this paper, a neutron moderation system for boron neutron capture therapy (BNCT) based on a $^{252}Cf$ neutron source is proposed. Different materials have been studied in order to produce a high percentage of epithermal neutrons. A moderator with a construction mixture of $AlF_3$ and Al, three reflectors of $Al_2O_3$, BeO, graphite, and seven filters (Bi, Cu, Fe, Pb, Ti, a two-layer filter of Ti+Bi, and a two-layer filter of Ti+Pb) is considered. The MCNPX simulation code has been used to calculate the neutron and gamma flux at the output window of the neutronic system. The results show that the epithermal neutron flux is relatively high for four filters: Ti+Pb, Ti+Bi, Bi, and Ti. However, a layer of Ti cannot reduce the contribution of ${\gamma}$-rays at the output window. Although the neutron spectra filtered by the Ti+Bi and Ti+Pb overlap, a large fraction of neutrons (74.95%) has epithermal energy when the Ti+Pb is used as a filter. However, the percentages of the fast and thermal neutrons are 25% and 0.5%, respectively. The Bi layer provides a relatively low epithermal neutron flux. Moreover, an assembly configuration of 30% $AlF_3+70%$ Al moderator/$Al_2O_3$ reflector/a two-layer filter of Ti+Pb reduces the fast neutron flux at the output port much more than other assembly combinations. In comparison with a recent model suggested by Ghassoun et al., the proposed neutron moderation system provides a higher epithermal flux with a relatively low contamination of gamma rays.

Measuring and unfolding fast neutron spectra using solution-grown trans-stilbene scintillation detector

  • Nguyen Duy Quang;HongJoo Kim;Phan Quoc Vuong;Nguyen Duc Ton;Uk-Won Nam;Won-Kee Park;JongDae Sohn;Young-Jun Choi;SungHwan Kim;SukWon Youn;Sung-Joon Ye
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1021-1030
    • /
    • 2023
  • We propose an overall procedure for measuring and unfolding fast neutron spectra using a trans-stilbene scintillation detector. Detector characterization was described, including the information on energy calibration, detector resolution, and nonproportionality response. The digital charge comparison method was used for the investigation of neutron-gamma Pulse Shape Discrimination (PSD). A pair of values of 600 ns pulse width and 24 ns delay time was found as the optimized conditions for PSD. A fitting technique was introduced to increase the trans-stilbene Proton Response Function (PRF) by 28% based on comparison of the simulated and experimental electron-equivalent distributions by the Cf-252 source. The detector response matrix was constructed by Monte-Carlo simulation and the spectrum unfolding was implemented using the iterative Bayesian method. The unfolding of simulated and measured spectra of Cf-252 and AmBe neutron sources indicates reliable, stable and no-bias results. The unfolding technique was also validated by the measured cosmic-ray induced neutron flux. Our approach is promising for fast neutron detection and spectroscopy.

영광 원자력발전소 원자로 건물내 중성자 스펙트럼 측정

  • 손중권;신상운;조찬희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.594-599
    • /
    • 1998
  • 출력 운전중 원자로 건물내의 중성자 에너지 스펙트럼의 분포를 살펴보기 위해 중성자 스펙트럼 측정을 수행하였다. 영광4흐기 원자로 건물내 100ft 상에서 4곳, 122ft 상에서 4곳, 144 ft 상에서 8곳을 Bonner Multisphere Spectrometer(BMS) 시스템을 이용하여 중성자 스펙트럼을 측정하였다. BMS는 Cf-252 선원으로 교정하였으며 측정된 데이터는 BUNKI 코드를 이용하여 unfolding 하여 에너지 스펙트럼을 얻었다 분석 결과 100 ft의 경우 평균 중성자 에너지는 0.100 ~ 1.954 MeV, Fluence는 4.913$\times$$10^2$ ~ 1.478$\times$$10^4$ n/$\textrm{cm}^2$, 선량율은 0.56 ~ 289.37 mrem/hr의 분포를, 122 ft의 경우 평균 중성자 에너지는 0.122 ~ 0.320 MeV, Fluence는 4.586$\times$$10^{0}$ ~ 7.743$\times$$10^3$ n$\textrm{cm}^2$, 선량율은 0.05 ~ 201.46 mrem/hr의 분포를, 144 ft의 경우 평균 중성자 에너지는 0.062 ~ 0.578 MeV, Fluence는 7.922$\times$$10^{0}$ ~ 1.703$\times$$10^2$ n/$\textrm{cm}^2$, 선량율은 0.10 ~ 45.58 mrem/hr의 분포를 보였다.

  • PDF