• Title/Summary/Keyword: $\rho$-power

Search Result 351, Processing Time 0.025 seconds

Research for the Pulsating Pressure Characteristics by a Damper and an Accumulator in the High Frequency Hydraulic System (고주파 유압시스템에서 감치장치와 축압기에 의한 맥동 충격파 감쇄특성에 대한 연구)

  • Kim, Yang-Soo;Kim, Jae-Soo;Rho, Hyung-Woon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.641-647
    • /
    • 2004
  • Characteristics of the high frequency pulsatile flow have been investigated experimentally to understand the flow phenomena in the hydraulic system. The accumulator in high frequency hydraulic system but that is not effective all frequency zone. Therefore, a hydraulic damper used with accumulator is suggested to reduce the high frequency pulsatile where the accumulator is not effective. The pulsating pressure obtained by Pressure measurement system are analyzed to power spectral density distribution. According to the variations of pump input pressure and actuator acceleration frequency, the pressure is measured with or without an accumulator or pulsatile damper The amplitude of pressure with damper is very lower than those without accumulator or damper due to absorbing function of damper. As the frequency of actuator acceleration is increased, the effect of damper becomes very important to decrease the amplitude of pulsatile Pressure waveform with high frequencies.

  • PDF

A Study on the Optimal Investment Method for Distribution Systems Interconnected with Dispersed Generations (분산전원이 연계된 배전계통의 최적 설비투자 방안에 관한 연구)

  • Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2179-2185
    • /
    • 2008
  • This paper deals with the optimal investment method for distribution facilities, based on the analytical approach for the reliability assessment in distribution systems interconnected with new dispersed generations. The existing approach can estimate the expected reliability performance of distribution systems by a direct assessment of the configuration of the systems using the reliability indexes such as NDP(Non-Delivery Power) and NDE(Non-Delivery Energy). The indexes can only consider the number and configuration of the load, but can not consider the characteristics of the load which is the one of the most important factor in the investment cost for the distribution systems. Therefore, this paper presents the new performance indexes for the investment of the distribution facilities considering both the expected interruption cost for the load section and the operation characteristics of dispersed generations. The results from a case study show that the proposed methods can be a practical tool for the voltage management in distribution systems including dispersed sources.

Design of decoder for Pulse-Position Modulation with Trellis-Coded Modulation on Non-Directed Indoor Infrared Channel (간접 실내 적외선 채널에서 Pulse-Position Modulation with Trellis-Coded Modulation을 위한 복호기 설계)

  • Jeong, S.;Rho, S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2467-2469
    • /
    • 1998
  • We examine the performance of high-speed non-directed infrared links using pulse-position modulation (PPM) with trellis-coded modulation (TCM) to mitigate the effects of multipath-induced intersymbol interference(ISI) on such links. Using the measured characteristics of multipath indoor infrared channels, we calculate BER curves and ISI power penalties for maximum-likelihood sequence detection of 8-PPM links using rate-2/3 trellis codes operation at 10 and 30Mb/s. Our results indicate that the suggested decoder of PPM with TCM is a very promising decoder on high-speed non-directed infrared channels.

  • PDF

A Study on the Dominant Oscillation Mode in the Multi-Machine System Using Static Var Compensator (무효 전력 보상장치를 이용한 다기 계통의 주요 진동 모드에 관한 연구)

  • Kwon, S.H.;Chang, B.H.;Rho, K.M.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.804-807
    • /
    • 1996
  • This paper addresses the small-signal stability and control problems associated with a Static Var Compensator and its power system stabilizer. The major emphasis is on determination of suitable location for SVC arid stabilizer signal tuning through eigenvalues and frequency response techniques. To determinate of suitable location for SVC, this paper used transfer function residues. Adequate oscillation damping is achieved by the use of stabilizing signals, designed through frequency response techniques and added to SVC. The study system is Benchmark System.

  • PDF

A study on the Optimal Operation of Step Voltage Regulator(SVR) in the Distribution Feeders(3) (고압배전선로의 선로전압조정장치(SVR)의 최적운용에 관한 연구(3))

  • Lee, Eun-Mi;Rho, Dae-Seok;Park, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.97-99
    • /
    • 2003
  • This paper deals with optimal voltage regulation methods of line voltage regulator(SVR : Step Voltage Regulator) in power distribution systems. In order to deliver suitable voltages to as many customers as possible, the optimal sending voltage of SVR should be decided by the effective operation of voltage regulators at the distribution feeders and substations. In this paper, a new voltage regulation method based on the existing method is presented and an optimal coordination method of multiple voltage regulators is extended. The results from a case study show that the proposed methods can be a practical tool for the voltage regulation in distribution systems.

  • PDF

The Optimal Scheduling and Operational characteristics on Battery Energy Storage System (전지전력저장설비의 최적운용 및 운전특성에 관한 연구)

  • Song, Kil-Yeong;Oh, Kwang-Hae;Kim, Yong-Ha;Rho, Dae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.102-105
    • /
    • 1993
  • The objective of this study is to solve the operation scheduling problem of plural battery energy storage systems (BESS), and to find useful intonation from its result. Unlike conventional energy storage system, BESS has on hardware characteristics such as high efficiency, fast-acting response and operational loss. Considering rate constraints of thermal unit power as well as hardware characteristics of BESS, the operation scheduling has an intricated problem. In order to solve this optimization problem, we use successive approximations dynamic programming. In two types of operation, the proposed algorithm is applied to test system. one is daily optimal operation, the other weekly optimal operation.

  • PDF

A Study of Digital Message Transfer System based on R-NAD for FM Radios (FM무전기를 통한 디지털 메시지 전송장비에 R-NAD 적용 연구)

  • Rho, Hai-Hwan;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.523-526
    • /
    • 2010
  • FM Radio communication operating mode is half-duplex mode. FM radio network access control shall be used to detect the presence of active transmissions on a multiple-subscriber-access communications network and shall provide a means to preclude data transmissions from conflicting on the network. In this study, we implemented R-NAD(Random Network Access Delay) that is one of network access control method.

  • PDF

A Study on the Power Quality Analysis for Photovoltaic System Using the LabVIEW S/W Systems (LabVIEW에 의한 태양광 연계시의 전력품질 특성에 관한 연구)

  • Song, Suk-Hwan;Kim, Byung-Mok;Park, Oh-Sung;Heo, Sang-Wn;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.56-59
    • /
    • 2010
  • 태양광과 풍력과 같은 분산전원이 배전계통에 연계되어 운용되는 경우, 수용가의 규정전압인 220${\pm}$6%(207[V]~233[V])를 벗어나는 현상이 발생할 수 있다. 본 논문에서는 태양광이 연계되는 위치에 따라 변동하는 선로임피던스(R${\pm}$jX)에 의하여 발생하는 순시 전압상승 및 전압강하에 의한 전력품질[과전압/저전압] 저하 현상을 LabVIEW S/W를 이용하여 확인하였으며, 이에 따른 문제점을 분석하고 그 해결책을 제시하였다.

  • PDF

Technical Trend on Excitation Capacitors on Harmonic Amplification of Wind Induction Generator (풍력 유도발전기의 여자 축전지에 따른 고주파 증폭에 관한 기술 동향)

  • Rho, Sang-Pil;Park, Jung-Seok;Lee, Young-Gil;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1976-1977
    • /
    • 2007
  • This paper introduce the electrical quantities of a three-phase-connected wind induction generator (WIG) under sudden connection of static loads. An intelligent power-system recorder/monitor is employed to measure threephase voltages and currents of the studied system at WIG's terminals and load's terminals for 5 minutes. A laboratory 300 W wound-rotor induction machine driven by a blushless DC motor is utilized as the studied WIG. Since the generated harmonic currents are randomly varied, total harmonic distortion (THD) of current using cumulative probability density function is employed to determine the penetration of harmonic distortion. The results show that the harmonic currents generated by the studied WIG may be severely amplified to a high level by the connected self-excited capacitance at the stator's terminals.

  • PDF

Nuclear Power Plant Site Evaluation Using Site Population-Meteorology Factor (인구ㆍ기상인자에 의한 원자력 발전소 부지 평가)

  • Byung Hwan Rho;Chang Sun Kang
    • Nuclear Engineering and Technology
    • /
    • v.14 no.1
    • /
    • pp.17-21
    • /
    • 1982
  • In this paper, as a site evaluation technique, SPMF(Site Population-Meteorology Factor) which is modified from SPF(Site Population Factor) of tile USNRC model, is defined from site population and meteorology data in order to consider the radiological impacts to the population at large from the atmospheric dispersion of the radioactive effluents released during routine plant operation as well as accidental conditions. The SPMF model proved its propriety from the comparison of SPMF and SPF for Kori site. The relative suitability of Korean sites to the U.S. sites have been also examined using SPF.

  • PDF