The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.19
no.2
/
pp.114-120
/
2008
This paper proposed the band pass filter(BPF) with feeding structure using $\pi$-type transmission line by means of transforming the input/output coupled-lines of the half wavelength parallel coupled-line BPF into K-inverter, then substituting $\pi$-type transmission line equivalence for K-inverter. The proposed method supplies solution with what the half wavelength parallel coupled-line BPF's input/output coupled-lines are realized. Also it can quite reduce efforts and time needed to optimize filter performance when is compared to reported method using tapped line structure because formulas is very simple and accurate. On the basic of the proposed method, the BPF with feeding structure using $\pi$-type transmission line has been designed and fabricated. The validity of proposed method was proven by the measured result.
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.19
no.8
/
pp.862-877
/
2008
In this paper, two types of wideband 3-dB ring hybrids are compared and discussed to show the ring hybrid with a set of coupled-line sections better. However, the better one still has a realization problem that perfect matching can be achieved only with -3 dB coupling power. To solve the problem, a set of coupled-line sections with two shorts is synthesized using one- and two-port equivalent circuits and design equations are derived to have perfect matching, regardless of the coupling power. Based on the design equations, a modified ${\Pi}-type$ of transmission-line equivalent circuit is newly suggested. It consists of coupled-line sections with two shorts and two open stubs and can be used to reduce a transmission-line section, especially when its electrical length is greater than ${\pi}$. Therefore, the $3\;{\lambda}/4$ transmission-line section of a conventional ring hybrid can be reduced to less than ${\pi}/2$. To verify the modified ${\Pi}-type$ of transmission- line equivalent circuit, two kinds of simulations are carried out; one is fixing the electrical length of the coupled-line sections and the other fixing its coupling coefficient. The simulation results show that the bandwidths of resulting small transmission lines are strongly dependent on the coupling power. Using modified and conventional ${\Pi}-types$ of transmission-line equivalent circuits, a small ring hybrid is built and named a compact wideband coupled-line ring hybrid, due to the fact that a set of coupled-line sections is included. One of compact ring hybrids is compared with a conventional ring hybrid and the compared results demonstrate that the bandwidth of a proposed compact ring hybrid is much wider, in spite of being more than three times smaller in size. To test the compact ring hybrids, a microstrip compact ring hybrid, whose total transmission-line length is $220^{\circ}$, is fabricated and measured. The measured power divisions($S_{21}$, $S_{41}$, $S_{23}$ and $S_{43}$) are -2.78 dB, -3.34 dB, -2.8 dB and -3.2 dB, respectively at a design center frequency of 2 GHz, matching and isolation less than -20 dB in more than 20 % fractional bandwidth.
Chua's circuit is a simple electronic network which exhibits a variety of bifurcation and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper, a transmitter and a receiver using two identical Chua's circuits are proposed and synchronizations of a T or ${\pi}$ type power line are investigated. Since the synchronization of the power line system is impossible by coupled synchronization, theory having both the drive-response and the coupled synchronization is proposed. As a result, the chaos synchronization has delay characteristics in the power line transmission system caused by the line parameters L and C
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.24
no.6
/
pp.602-612
/
2013
In this paper, a design and fabrication of miniaturized 5.3 GHz reflection type $360^{\circ}$ analog phase shifter with branch line coupler and $360^{\circ}$ variable reactance load. In order to miniaturize phase shifter, novel branch line coupler is proposed. The novel branch line coupler is miniaturized using transformation of transmission line to T and ${\pi}$ type equivalent circuit. The miniaturized branch line coupler has small size of above 50 % compared with conventional branch line coupler. For wide phase shift range, $360^{\circ}$ variable reactance load structure is adopted. Especially, the structure was improved for linear phase shift by adding transmission line which acts as an impedance transformer. The improved structure was miniaturized using the equivalent lumped-element of transmission line. The fabricated phase shifter with $15{\times}15mm^2$ shows wide phase shift of above $480^{\circ}$, the insertion loss of -4~-6 dB and the reflection loss of below -20 dB at 5.3 GHz under 0~10 V control voltage range.
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.13
no.2
/
pp.123-129
/
2002
5-bit broadband MMIC phase shifter has been designed and fabricated. For the broadband performance, 11.25$^{\circ}$, 22.5$^{\circ}$, 45$^{\circ}$ and 90$^{\circ}$ bit have been designed with Lange coupler and 180$^{\circ}$ bit has been implemented by using shorted coupled line with Lange coupler and $\pi$-network of transmission line. Due to Lange coupler with large size, the Lange couplers have been folded far circuit size reduction. Low loss PIN diode has been utilized as a switch for each bit. Fabricated 5-bit broadband phase shifter shows the measured results that RMS phase error of 5 major phases is 3.5$^{\circ}$, maximum insertion loss is 12.5 dB, and maximum input and output return loss are 7 dB and 10 dB, respectively. The size of fabricated phase shifter is 6.5$\times$5.3 $ extrm{mm}^2$.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.24
no.2
/
pp.16-26
/
2010
The transmission valuation methodology we propose here captures the interaction between generation and transmission investment decisions recognizing that a transmission expansion can impact the profitability of new resources investment, so that a methodology should consider both the objectives of investors in resources and the transmission planner. In this perspective, this paper purports to develop the mixed-integer programming based transmission expansion planning optimization software, which is well designed to determine the construction time and place of new generators, transmission lines, and substations as well as their capacities to minimize total expenditures related to their investment and operations while meeting technical constraints such as capacity margin, constitution ratio of power resources, spinning reserves, energy and fuel constraints, transmission line outages and losses, pi-type branching, and so on. Finally, Garver's simple system is adopted to validate not simply the accuracy but the efficiency of the proposed model in this paper.
The Journal of the Institute of Internet, Broadcasting and Communication
/
v.16
no.1
/
pp.239-244
/
2016
The polarization characteristics of polarization-insensitive directional coupler based on double sandwiched rib-type and curved waveguides are explored in detail by using conformal transformation method (CTM) and longitudinal modal transmission-line theory(L-MTLT). To obtain the polarization-insensitive condition of polarization-insensitive curved directional coupler(PI-CDC), the coupling length and coupling efficiency according to the inner radius of PI-CDC are analyzed for quasi-TE and quasi-TM modes. The numerical results show that the PI-CDC with a few micrometer scales can be realized by properly choosing the curvature and structural and material parameters of double sandwiched layers. Furthermore, the mode profiles propagating through PI-CDC are evaluated, and the influence on coupler performance has been investigated.
Kim, Kwi-Soo;Gwon, Chil-Hyeun;Dorjsuren, Baatarkhuu;Lim, Jong-Sik;Ahn, Dal
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.20
no.5
/
pp.444-449
/
2009
This paper presents the design of a dual band branch line hybrid coupler(BLHC) with different power division ratios at two bands. In the proposed design, transmission lines of the BLHC are transformed to $\pi$-type equivalent circuits which represent different impedances and $\lambda/4$ electrical length at two frequency bands. In order to verify the proposed method, a dual band coupler with different power division ratios is designed for 0.9 GHz and 2 GHz applications. The desired power division ratios are 1:1 and 1:3 at the two operating frequency bands. The measured results show excellent performance with an insertion loss of less than 0.33 dB, a return loss of less than -18.07 dB, and good isolation characteristics.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.