• Title/Summary/Keyword: $\phi-q-n$

Search Result 80, Processing Time 0.028 seconds

Partial Discharge Characteristics of Silicone Rubber for Insulator by Impurities (불순물에 따른 애자용 실리콘고무의 부분방전특성)

  • Kim, T.Y.;Lee, H.J.;Shin, H.T.;Lee, C.H.;Lee, D.J.;Kim, W.K.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.506-509
    • /
    • 2003
  • In this paper, the $\Phi$-q-n pattern and average discharge power of silicone rubber have investigated effect of inter impurities. It's changed impurities by silicone oil, water and copper. Applied voltage is AC 3, 4, 4.5, 5, 5.5[kV]. And data acquisition time is 10 second(600 cycles). These results suggest that partial discharge(PD) is shower negative polar than positive polar at 3[kV]. Positive polar's PD value increased with increase of applied voltage. The Conductivities expressed same $\Phi$-q-n pattern in positive polar and negative polar at phase region.

  • PDF

Partial Discharge Diagnosis of Interface Defect by the Distribution Statistical Analysis (분포 통계 해석에 의한 계면 결함 부분방전 진단)

  • Cho, Kyung-Soon;Lee, Kang-Won;Kim, Won-Jong;Hong, Jin-Woong;Shin, Jong-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.4
    • /
    • pp.348-353
    • /
    • 2008
  • Most of the high voltage insulation systems, such as the power cable joint having hetero interface, are composed of more than two different insulators to improve insulating performance. The partial discharge(PD) in these hetero interface is expected to affect the total insulation performance. Thus, it is important to study electrical properties on these interfaces. This study described the influence of copper and semiconductive substance defects on $\Phi$-q-n distribution between the interface of the model cable joints to classify PD source. PD was sequentially detected for 600 cycles of the applied voltage. The K-means cluster analysis has been analyzed to investigate the $\Phi$-q-n distribution. The skewness-kurtosis(Sk-Ku) plot from K-means clustering results was defined to quantify cluster distribution and classify distribution patterns. The Sk-Ku plot is composed of skewness and kurtosis along abscissa and ordinate which indicate the asymmetry and the sharpness of distribution. As a result of the Sk-Ku plot, it was confirmed that the data was distributed in 1st 2nd and 3rd quadrant at copper foreign substance defect, but in case of semiconductive foreign substance, the data was distributed in 2nd quadrant only.

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.

A Experimental Investigation on the PD Characteristics depending on the various Artificial Voids In Epoxy Insulator (에폭시 절연체의 보이드 크기에 따른 부분방전 특성연구)

  • Choi, C.K.;Lee, J.S.;Kim, J,T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1853-1855
    • /
    • 2000
  • An experimental investigation has been performed in order to understand the $\Phi$-q-n characteristics related to the PD taking place from the various size of artificial defects inserted in epoxy insulation. In this purpose, PD has been detected simultaneously by two different methods such as commercialized PD detector(TE571) and our detection system using self designed CT type sensor. Under the presence of void in epoxy insulation, PD has been initiated at the voltages between 16kV and 20kV which are much lower than the dielectric strength of epoxy insulation (130kV/mm$\sim$l50kV/mm). And also it is revealed that $\Phi$-q-n characteristics have been observed to be dependent upon the size of the artificial defects. Throughout this work, the on site applicability of the self designed Sensor has also been proved by comparing the results with those from the commercialized PD detector. And more one, considerable basic data regarding the insulation, diagnosis could be provided to understand the presence of the voids possibly inserted into the epoxy insulation system of the power apparatus.

  • PDF

IMPROVED MULTIPLICITY RESULTS FOR FULLY NONLINEAR PARABOLIC SYSTEMS

  • Jung, Tacksun;Choi, Q-Heung
    • Korean Journal of Mathematics
    • /
    • v.17 no.3
    • /
    • pp.283-291
    • /
    • 2009
  • We investigate the existence of multiple solutions (${\xi},{\eta}$) for perturbations of the parabolic system with Dirichlet boundary condition $$(0.1)\;\begin{array}{lcr}{\xi}_t=-L{\xi}+g_1(3{\xi}+{\eta})-s{\phi}_1-h_1(x,t)\;in\;{\Omega}{\times}(0,\;2{\pi}),\\{\eta}_t=-L{\eta}+g_2(3{\xi}+{\eta})-s{\phi}_1-h_2(x,t)\;in\;{\Omega}{\times}(0,\;2{\pi}).\end{array}$$ We show the existence of multiple solutions (${\xi},{\eta}$) for perturbations of the parabolic system when the nonlinearity $g^{\prime}_1,\;g^{\prime}_2$ are bounded and $3g^{\prime}_1(-{\infty})+g^{\prime}_2(-{\infty})<{\lambda}_1,\;{\lambda}_n<3g^{\prime}_1(+{\infty})+g^{\prime}_2(+{\infty})<{\lambda}_{n+1}$.

  • PDF

PERIODIC SOLUTIONS FOR NONLINEAR PARABOLIC SYSTEMS WITH SOURCE TERMS

  • Jung, Tacksun;Choi, Q-Heung
    • Korean Journal of Mathematics
    • /
    • v.16 no.4
    • /
    • pp.553-564
    • /
    • 2008
  • We have a concern with the existence of solutions (${\xi},{\eta}$) for perturbations of the parabolic system with Dirichlet boundary condition $$(0.1)\;\begin{array}{lcr}{\xi}_t=-L{\xi}+{\mu}g(3{\xi}+{\eta})-s{\phi}_1-h_1(x,t)\;in\;{\Omega}{\times}(0,2{\pi}),\\{\eta}_t=-L{\eta}+{\nu}g(3{\xi}+{\eta})-s{\phi}_1-h_2(x,t)\;in\;{\Omega}{\times}(0,2{\pi})\end{array}.$$ We prove the uniqueness theorem when the nonlinearity does not cross eigenvalues. We also investigate multiple solutions (${\xi}(x,t),\;{\eta}(x,t)$) for perturbations of the parabolic system with Dirichlet boundary condition when the nonlinearity f' is bounded and $f^{\prime}(-{\infty})<{\lambda}_1,{\lambda}_n<(3{\mu}+{\nu})f^{\prime}(+{\infty})<{\lambda}_{n+1}$.

  • PDF

MULTIPLICITY OF POSITIVE SOLUTIONS FOR MULTIPOINT BOUNDARY VALUE PROBLEMS WITH ONE-DIMENSIONAL P-LAPLACIAN

  • Zhang, Youfeng;Zhang, Zhiyu;Zhang, Fengqin
    • Journal of applied mathematics & informatics
    • /
    • v.27 no.5_6
    • /
    • pp.1211-1220
    • /
    • 2009
  • In this paper, we consider the multipoint boundary value problem for the one-dimensional p-Laplacian $({\phi}_p(u'))'$(t)+q(t)f(t,u(t),u'(t))=0, t $\in$ (0, 1), subject to the boundary conditions: $u(0)=\sum\limits_{i=1}^{n-2}{\alpha}_iu({\xi}_i),\;u(1)=\sum\limits_{i=1}^{n-2}{\beta}_iu({\xi}_i)$ where $\phi_p$(s) = $|s|^{n-2}s$, p > 1, $\xi_i$ $\in$ (0, 1) with 0 < $\xi_1$ < $\xi_2$ < $\cdots$ < $\xi{n-2}$ < 1 and ${\alpha}_i,\beta_i{\in}[0,1)$, 0< $\sum{\array}{{n=2}\\{i=1}}{\alpha}_i,\sum{\array}{{n=2}\\{i=1}}{\beta}_i$<1. Using a fixed point theorem due to Bai and Ge, we study the existence of at least three positive solutions to the above boundary value problem. The important point is that the nonlinear term f explicitly involves a first-order derivative.

  • PDF

The intermediate solution of quasilinear elliptic boundary value problems

  • Ko, Bong-Soo
    • Journal of the Korean Mathematical Society
    • /
    • v.31 no.3
    • /
    • pp.401-416
    • /
    • 1994
  • We study the existence of an intermediate solution of nonlinear elliptic boundary value problems (BVP) of the form $$ (BVP) {\Delta u = f(x,u,\Delta u), in \Omega {Bu(x) = \phi(x), on \partial\Omega, $$ where $\Omega$ is a smooth bounded domain in $R^n, n \geq 1, and \partial\Omega \in C^{2,\alpha}, (0 < \alpha < 1), \Delta$ is the Laplacian operator, $\nabla u = (D_1u, D_2u, \cdots, D_nu)$ denotes the gradient of u and $$ Bu(x) = p(x)u(x) + q(x)\frac{d\nu}{du} (x), $$ where $\frac{d\nu}{du} denotes the outward normal derivative of u on $\partial\Omega$.

  • PDF

Properties and Classification of Patterns of Air Discharges (기중방전의 방전원별 특성분석 및 패턴분류)

  • Park, Yeong-Guk;Lee, Gwang-U;Jang, Dong-Uk;Gang, Seong-Hwa;Jeong, Gwang-Ho;Kim, Wan-Su;Lee, Yong-Hui;Im, Gi-Jo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

Partial Discharge Data Analysis with Unsupervised Classification (무감독분류 기법에 의한 부분방전 데이터 분석)

  • Cho, Kyungsoon;Hong, Seonhack
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.4
    • /
    • pp.9-16
    • /
    • 2018
  • This study described partial discharge(PD) distribution analysis between the XLPE(Cross-Linked PolyEthylene)and EPDM(Ethylene Propylene Diene Monomer) interface with unsupervised classification. The ${\phi}-q-n$ patterns were analyzed using phase resolved partial discharge(PRPD). K-means cluster analysis forms a cluster based on similarities and distances among scattered individuals, and analyzes the characteristics of the formed clusters, dividing the multivariate data into several groups according to the similarity of each characteristic, Is a statistical analysis that makes it easier to navigate. It was confirmed that the phase angle of the cluster with the maximum discharge charge was concentrated around $0^{\circ}$ and $180^{\circ}$ at 30 kV after the initial phase distribution localized around $90^{\circ}$ and $300^{\circ}$ expanded to the whole phase angle according to the voltage rise. The Euclidean distance between the center of gravity and the discharge charge in the ${\Phi}-q$ cluster increased with increasing applied voltage.