• 제목/요약/키워드: $\phi-q-n$

검색결과 80건 처리시간 0.021초

부시형 전기트리의 성장에 따른 부분방전 펄스의 분포 특성 (Properties of Distribution of PD Pulses accompanying with Propagation of bush-type Tree)

  • 강성화;정수현;이광우;장동욱;류부형;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1478-1480
    • /
    • 1998
  • Inception and propagation of electrical tree and properties of partial discharge(PD) pulses accompanying with tree in low density polyethylene were discussed. We observed the characteristics of process of electrical tree by using optical microscope and investigated the statistical characteristics of the PD pulses by analyzing PD quantities and distribution patterns. The PD pulses were analyzed by q-n, $\phi$-n and $\phi$-q distribution. The statistical operators used were skewness(s), kurtosis(k) and average phase angle. The skewness and average discharge phase angle of PD pulses increased as the Propagation of tree. The kurtosis was about 1.8 at the Inception of tree, but It increased as the propagation of tree.

  • PDF

전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석 (Properties on the Distribution Pattern of Discharge Signals Generated in the Power Cable)

  • 소순열;홍경진;이우기;이동인;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.13-18
    • /
    • 1998
  • After Computer-based PD measurement was referred in the 1970's, the new technology and a number of digital system have been studied. And the selection of PD patterns, extraction of relevant information for PD recognition are discussed because the number of pulse as a function of discharge magnitude and discharge pulse as a function of the power frequency cycl4e offer the information of the aging insulation. This paper investigates the discharge phase($\phi$) and magnitude(q), as well as the number of discharge(n) with regard to discharge signals generated in power cable. Therefore, according to properties analysis on the distribution of $\phi$ , q and n, it is able to apply in the aging analysis of power cable which visual observation is impossible and distribution change of discharge signals offers much information for risk degree on aging progress of insulation materials.

  • PDF

XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형 (Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface)

  • 조경순
    • 한국컴퓨터산업학회논문지
    • /
    • 제6권2호
    • /
    • pp.357-364
    • /
    • 2005
  • 최근 들어 우리나라에서는 설치의 간편성과 높은 신뢰도를 가진 전력케이블의 사용이 증가하고 있다. 전력케이블은 출고 전에 IEEE std. 404-1993 시험을 거쳐 안정성을 확인하고 있지만 포설시 발생하는 접속부 내부의 결함으로 인하여 많은 문제가 발생하고 있다. 특히 불순물 혼입 또는 공극 발생시 고장율은 증가하게 된다 부분방전 검출은 포설 후 전력케이블의 상태를 관측할 수 있는 유용한 방법이다. 본 연구에서는 부분방전 특성을 평가하고자 케이블 접속재인 EPR과 케이블 절연체인 XPLE 사이에 인공 결함을 발생시킨 후 데이터 취득 시스템을 이용하여 $\Phi-q-n$ 특성을 검출하였으며, 부분방전의 정량적 해석을 위해 필요한 통계량을 계산하였으며, 신경망 모델을 적용하여 패턴 분석을 수행하여 $88\~96\%$의 구별이 가능하였다.

  • PDF

XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형 (Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface)

  • 조경순
    • 한국컴퓨터산업학회논문지
    • /
    • 제6권2호
    • /
    • pp.279-286
    • /
    • 2005
  • 최근 들어 우리나라에서는 설치의 간편성과 높은 신뢰도를 가진 전력케이블의 사용이 증가하고 있다. 전력케이블은 출고 전에 IEEE std. 404-1993 시험을 거쳐 안정성을 확인하고 있지만 포설시 발생하는 접속부 내부의 결함으로 인하여 많은 문제가 발생하고 있다. 특히 불순물 혼입 또는 공극 발생시 고장율은 증가하게 된다. 부분방전 검출은 포설 후 전력케이블의 상태를 관측할 수 있는 유용한 방법이다. 본 연구에서는 부분방전 특성을 평가하고자 케이블 접속재인 EPR과 케이블 절연체인 XPLE 사이에 인공 결함을 발생시킨 후 데이터 취득 시스템을 이용하여 $\Phi-q-n$ 특성을 검출하였으며, 부분방전의 정량적 해석을 위해 필요한 통계량을 계산하였으며, 신경망 모델을 적용하여 패턴 분석을 수행하여 $88\~96\%$의 구별이 가능하였다.

  • PDF

고추의 엽록소 형광 이미지 분석법에 의한 한발스트레스 지표화 가능성 (Possibility of Drought stress Indexing by Chlorophyll Fluorescence Imaging Technique in Red Pepper (Capsicum annuum L.))

  • 유성녕;엄기철;박소현;김태완
    • 한국토양비료학회지
    • /
    • 제45권5호
    • /
    • pp.676-682
    • /
    • 2012
  • 본 연구에서는 생육초기 고추의 한발 스트레스 조건에서 작물 생육에 미치는 영향을 구명하기 위해 엽록소 이미지형 광분석을 이용하여 엽록소 형광 매개변수를 비교분석 하였다. 비록 통계적 유의성이 인정되지는 않았지만 전체 잎의 이미지에 나타나는 형광매개변수들의 평균값은 감소하는 경향이었다. 가변형광값에대한 최대형광값의 비는 변동이 없는 반면, 광계II의 정류상태에서의 양자수득율 및 형광감쇄율은 다소 감소하였다. 이러한 현상은 퀴논 A 단백질로부터 퀴논 B 단백질로의 전자전달의 감소를 의미하였다. 잎의 중앙부위와 엽병부근에서의 비광학적 소광 및 가변형광의 비광학적 소광 상수는 한발스트레스 4일 후 유의성있게 증가하였다. 즉 생리적 스트레스 매개변수로 활용이 가능하였다. 광계II에서의 정류상태 양자수득율의 감소는 고추잎의 모든 부위에서 공통적으로 유의성있게 측정되었다. 결론적으로 ${\Phi}PSII$ ($QY_{_-LSS}$), $NPQ_{_-LSS}$, qN 등의 엽록소형광 매개변수들은 고추의 한발스트레스를 판단할 수 있는 생리적 지표로 활용 가능한 것으로 유의성이 인정되었다.

Liquid Membrane Permeation of Nitrogen Heterocyclic Compounds Contained in Model Coal Tar Fraction

  • Kim, Su-Jin;Kang, Ho-Cheol;Kim, Yong-Shik;Jeong, Hwa-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1143-1148
    • /
    • 2010
  • We investigated the separation of nitrogen heterocyclic compound (NHC) contained in a model coal tar fraction comprising four kinds of NHC [indole (In), quinoline (Q), iso-quinoline (iQ), quinaldine (Qu)], three kinds of bicyclic aromatic compound (BAC) [1-methylnaphthalene (1MN), 2-methylnaphthalene (2MN), dimethylnaphthalene (DMN) mixture with ten structural isomers (DMNs; regarded as one component)], biphenyl (Bp) and phenyl ether (Pe) by liquid membrane permeation (LMP). A batch-stirred tank was used as the permeation unit. An aqueous solution of saponin and n-hexane were used as the liquid membrane and the outer oil phase, respectively. Yield and selectivity of individual NHC was much larger than that of BAC, Bp and Pe. Increasing the initial mass fraction of the saponin to the membrane solution ($C_{sap,0}$) and the initial volume fraction of O/W emulsion to total liquid in a stirred tank (${\phi}_{OW,0}$) resulted in deteriorating the yield of individual NHC, but increasing the stirring speed (N) resulted in improving the yield of each NHC. With increasing $C_{sap,0}$, the selectivity of each NHC based on DMNs increased. Increasing ${\phi}_{OW,0}$ and N resulted in decreasing the selectivity of individual NHC based on DMNs. At an experimental condition fixed, the sequence of the yield and selectivity in reference to DMNs for each NHC was Q > Qu = iQ > In. Furthermore, we compared LPM method with methanol extraction method in view of the separation efficiency (yield, selectivity) of NHC.

고체절연재료에서 발생하는 부분방전 특성량의 Data-Base 구축 (Data-Base of Statistical Parameters from PD generated in Solid Insulation)

  • 강성화;이흥규;박영국;김완수;이용희;박정남;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1927-1929
    • /
    • 2000
  • PD indicates the inception and progress of degradation of solid insulation system, so it has been used to determine degradation of insulation. PD provides means for detection and recognition of defects. However, there is still marked difficult to recognize defects by PD methods. In this paper, we investigated properties of PD in solid insulation by using statistical method with surface discharge, electrical tree and void discharge with source of discharge, we used statistical parameters of PD distributions specified such as $H_n(q)$, $H_{an}(\phi)$, $H_n(\phi)$, $H_a(\phi)$. The parameters induced from its specified distributions are average discharge, average repetition rate, Skewness, Kurtosis, asymmetry and correlation. From the parameters, we classified PD patterns and built up DB(data-base).

  • PDF

장시간 절연체 열화실험을 위한 부분방전측정기술 연구 (A Study on the Technology Measuring Partial Discharge for Long Term Aging Experiments of Insulation Materials)

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.665-672
    • /
    • 2000
  • This paper described the measurement technology to analyze the partial discharge characteristics for long term aging of insulations. This system was consisted of high voltage generation and measurement part, PD detection part, digital conversion and signal processing part. We used the VXI system for digital conversion and signal processing part. In the digital conversion part, we studied the error of partial discharge magnitude and memory capacity for reading digital signal with the sampling rate. In the signal processing part, we showed the program algorithm to count pulses and read peak values of partial discharge. The allowable minimum sampling rate of digizer was decided to 250kS/s through analyzing test. We confirmed that this system was very useful in the study of $\phi-q-n$ characteristics of long term PD experiments with specimens being consisted of internal void defects and CIGRE II electrodes.

  • PDF

Improvement of tip analysis model for drilled shafts in cohesionless soils

  • Chen, Yit-Jin;Wu, Hao-Wei;Marcos, Maria Cecilia M.;Lin, Shiu-Shin
    • Geomechanics and Engineering
    • /
    • 제5권5호
    • /
    • pp.447-462
    • /
    • 2013
  • An analysis model for predicting the tip bearing capacity of drilled shafts in cohesionless soils is improved in this study. The evaluation is based on large amounts of drilled shaft load test data. Assessment on the analysis model reveals a greater variation in two coefficients, namely, the overburden bearing capacity factor ($N_q$) and the bearing capacity modifier for soil rigidity (${\zeta}_{qr}$). These factors are modified from the back analysis of drilled shaft load test results. Different effective shaft depths and interpreted capacities at various loading stages (i.e., low, middle, and high) are adopted for the back calculation. Results show that the modified bearing capacity coefficients maintain their basic relationship with soil effective friction angle ($\bar{\phi}$), in which the $N_q$ increases and ${\zeta}_{qr}$ decreases as $\bar{\phi}$ increases. The suggested effective shaft depth is limited to 15B (B = shaft diameter) for the evaluation of effective overburden pressure. Specific design recommendations for the tip bearing capacity analysis of drilled shafts in cohesionless soils are given for engineering practice.

전극 형태에 따른 가교폴리에틸렌 절연체의 방전분포해석 (The Discharge Distribution Analysis of Cross-Linking Polyethylene due to Shape of Electrode)

  • 김탁용;양재훈;김귀열;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.308-311
    • /
    • 2004
  • In this paper, we investigated $\phi-q-n$ distribution to inquire discharge characteristic according to variation of electrode. Also, we investigated Weible distribution of discharge number using Weible analysis to search the relationship between a part discharge and shape of electrode. We increased voltage 1[kV] AC 60[Hz] of impressed voltage, data is acquired a generating discharge for 10 seconds after impressing voltage. Also, as we repeated the experiment 10 times at same condition, analyzed foible using data except for maximum and minimum. As the result, we confirmed that discharge generating and discharge quantity were significantly increased narrowing radius of electrode, also discharge frequency was close to shape of a standard distribution.