• Title/Summary/Keyword: $\phi$ -q-n

Search Result 79, Processing Time 0.023 seconds

Properties on the Distribution Pattern of Discharge Signals Generated in the Power Cable (전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석)

  • 소순열;홍경진;이우기;이동인;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.13-18
    • /
    • 1998
  • After Computer-based PD measurement was referred in the 1970's, the new technology and a number of digital system have been studied. And the selection of PD patterns, extraction of relevant information for PD recognition are discussed because the number of pulse as a function of discharge magnitude and discharge pulse as a function of the power frequency cycl4e offer the information of the aging insulation. This paper investigates the discharge phase($\phi$) and magnitude(q), as well as the number of discharge(n) with regard to discharge signals generated in power cable. Therefore, according to properties analysis on the distribution of $\phi$ , q and n, it is able to apply in the aging analysis of power cable which visual observation is impossible and distribution change of discharge signals offers much information for risk degree on aging progress of insulation materials.

  • PDF

Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface (XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형)

  • Cho, Kyung-Soon
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.357-364
    • /
    • 2005
  • The prefabricated type used generally in Korea to join cable runs on new installations or to repair broken Cable runs on existing installations, because installation is very simple and save time. This type is a permanent, shielded and submersible cable joint for direct burial or vault application. It confirms to the requirements of IEEE std. 404-1993 by factory testing, but many problems of insulated cable systems are caused by internal defects of the joint part which have to be mounted ensile. Faults arise from impurities or voids. A suitable solution for a monitoring of cable joints during the after-laying test and service is partial discharge detection. Specimen obtained 1mm thickness from the insulation of real power cable and cable joint. <중략>The partial discharges are measured to determine their time dependence for 60 minutes and the influence of applied electrical stress under 30kV. $\Phi-q-n$ properties were measured using detection impedance, high pass filter and computerized data acquisition system. Statistic Value like maximum charge, repetition rate, average charge, etc. are calculated. It is possible to quantitative analysis of $\Phi-q-n$ properties from this statistic value and pattern analysis.

  • PDF

Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface (XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형)

  • Cho Kyung-Soon
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.279-286
    • /
    • 2005
  • The prefabricated type used generally in Korea to join cable runs on new installations or to repair broken Cable runs on existing installations, because installation is very simple and save time. This type is a permanent, shielded and submersible cable joint for direct burial or vault application. It confirms to the requirements of IEEE std. 404-1993 by factory testing, but many problems of insulated cable systems are caused by internal defects of the joint part which have to be mounted ensile. Faults arise from impurities or voids. A suitable solution for a monitoring of cable joints during the after-laying test and service is partial discharge detection. <중략> $\Phi-q-n$ properties were measured using detection impedance, high pass filter and computerized data acquisition system. Statistic Value like maximum charge, repetition rate, average charge, etc. are calculated. It is possible to quantitative analysis of $\Phi-q-n$ properties from this statistic value and pattern analysis.

  • PDF

Possibility of Drought stress Indexing by Chlorophyll Fluorescence Imaging Technique in Red Pepper (Capsicum annuum L.) (고추의 엽록소 형광 이미지 분석법에 의한 한발스트레스 지표화 가능성)

  • Yoo, Sung-Yung;Eom, Ki-Cheol;Park, So-Hyun;Kim, Tae-Wan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.676-682
    • /
    • 2012
  • The objectives of this study focused on measuring chlorophyll fluorescence related to drought stress comparing some parameters. Almost parameters were declined although they were not significant on the basis of mean values of fluorescence of total leaf area. While the ratio of fluorescence intensity variable chlorophyll ($F_V$) to fluorescence intensity maximal chlorophyll ($F_M$) was not changed, the effective quantum yield of photochemical energy conversion in photosystemII (${\Phi}PSII$) and chlorophyll fluorescence decrease ratio ($R_{fd}$) were slightly reduced, indicating inhibition of the electron transport from quinone bind protein A ($Q_A$) to quinone bind protein B ($Q_B$). Some parameters such as non-photochemical quenching rate ($NPQ_{_-LSS}$) and coefficients of non-photochemical quenching of variable fluorescence (qN) in mid-zone of leaf and near petiole zone leaf were significantly enhanced within 4 days after drought stress, which can be used as physiological stress parameters. Decrease in ${\Phi}PSII$ could was significantly measured in all leaf zones. In conclusion, three parametric evidences for chlorophyll fluorescence responses such as ${\Phi}PSII$, NPQ, and qN insinuated the possibility of photophysiological indices under drought stress.

Liquid Membrane Permeation of Nitrogen Heterocyclic Compounds Contained in Model Coal Tar Fraction

  • Kim, Su-Jin;Kang, Ho-Cheol;Kim, Yong-Shik;Jeong, Hwa-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1143-1148
    • /
    • 2010
  • We investigated the separation of nitrogen heterocyclic compound (NHC) contained in a model coal tar fraction comprising four kinds of NHC [indole (In), quinoline (Q), iso-quinoline (iQ), quinaldine (Qu)], three kinds of bicyclic aromatic compound (BAC) [1-methylnaphthalene (1MN), 2-methylnaphthalene (2MN), dimethylnaphthalene (DMN) mixture with ten structural isomers (DMNs; regarded as one component)], biphenyl (Bp) and phenyl ether (Pe) by liquid membrane permeation (LMP). A batch-stirred tank was used as the permeation unit. An aqueous solution of saponin and n-hexane were used as the liquid membrane and the outer oil phase, respectively. Yield and selectivity of individual NHC was much larger than that of BAC, Bp and Pe. Increasing the initial mass fraction of the saponin to the membrane solution ($C_{sap,0}$) and the initial volume fraction of O/W emulsion to total liquid in a stirred tank (${\phi}_{OW,0}$) resulted in deteriorating the yield of individual NHC, but increasing the stirring speed (N) resulted in improving the yield of each NHC. With increasing $C_{sap,0}$, the selectivity of each NHC based on DMNs increased. Increasing ${\phi}_{OW,0}$ and N resulted in decreasing the selectivity of individual NHC based on DMNs. At an experimental condition fixed, the sequence of the yield and selectivity in reference to DMNs for each NHC was Q > Qu = iQ > In. Furthermore, we compared LPM method with methanol extraction method in view of the separation efficiency (yield, selectivity) of NHC.

Data-Base of Statistical Parameters from PD generated in Solid Insulation (고체절연재료에서 발생하는 부분방전 특성량의 Data-Base 구축)

  • Kang, S.H.;Lee, H.G.;Park, Y.G.;Kim, W.S.;Lee, Y.H.;Park, J.N.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1927-1929
    • /
    • 2000
  • PD indicates the inception and progress of degradation of solid insulation system, so it has been used to determine degradation of insulation. PD provides means for detection and recognition of defects. However, there is still marked difficult to recognize defects by PD methods. In this paper, we investigated properties of PD in solid insulation by using statistical method with surface discharge, electrical tree and void discharge with source of discharge, we used statistical parameters of PD distributions specified such as $H_n(q)$, $H_{an}(\phi)$, $H_n(\phi)$, $H_a(\phi)$. The parameters induced from its specified distributions are average discharge, average repetition rate, Skewness, Kurtosis, asymmetry and correlation. From the parameters, we classified PD patterns and built up DB(data-base).

  • PDF

A Study on the Technology Measuring Partial Discharge for Long Term Aging Experiments of Insulation Materials (장시간 절연체 열화실험을 위한 부분방전측정기술 연구)

  • Seon, Jong-Ho;Kim, Gwang-Hwa;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.665-672
    • /
    • 2000
  • This paper described the measurement technology to analyze the partial discharge characteristics for long term aging of insulations. This system was consisted of high voltage generation and measurement part, PD detection part, digital conversion and signal processing part. We used the VXI system for digital conversion and signal processing part. In the digital conversion part, we studied the error of partial discharge magnitude and memory capacity for reading digital signal with the sampling rate. In the signal processing part, we showed the program algorithm to count pulses and read peak values of partial discharge. The allowable minimum sampling rate of digizer was decided to 250kS/s through analyzing test. We confirmed that this system was very useful in the study of $\phi-q-n$ characteristics of long term PD experiments with specimens being consisted of internal void defects and CIGRE II electrodes.

  • PDF

Improvement of tip analysis model for drilled shafts in cohesionless soils

  • Chen, Yit-Jin;Wu, Hao-Wei;Marcos, Maria Cecilia M.;Lin, Shiu-Shin
    • Geomechanics and Engineering
    • /
    • v.5 no.5
    • /
    • pp.447-462
    • /
    • 2013
  • An analysis model for predicting the tip bearing capacity of drilled shafts in cohesionless soils is improved in this study. The evaluation is based on large amounts of drilled shaft load test data. Assessment on the analysis model reveals a greater variation in two coefficients, namely, the overburden bearing capacity factor ($N_q$) and the bearing capacity modifier for soil rigidity (${\zeta}_{qr}$). These factors are modified from the back analysis of drilled shaft load test results. Different effective shaft depths and interpreted capacities at various loading stages (i.e., low, middle, and high) are adopted for the back calculation. Results show that the modified bearing capacity coefficients maintain their basic relationship with soil effective friction angle ($\bar{\phi}$), in which the $N_q$ increases and ${\zeta}_{qr}$ decreases as $\bar{\phi}$ increases. The suggested effective shaft depth is limited to 15B (B = shaft diameter) for the evaluation of effective overburden pressure. Specific design recommendations for the tip bearing capacity analysis of drilled shafts in cohesionless soils are given for engineering practice.

The Discharge Distribution Analysis of Cross-Linking Polyethylene due to Shape of Electrode (전극 형태에 따른 가교폴리에틸렌 절연체의 방전분포해석)

  • Kim, Tag-Yong;Yang, Jae-Hoon;Kim, Gwi-Yeol;Lee, Chung-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.308-311
    • /
    • 2004
  • In this paper, we investigated $\phi-q-n$ distribution to inquire discharge characteristic according to variation of electrode. Also, we investigated Weible distribution of discharge number using Weible analysis to search the relationship between a part discharge and shape of electrode. We increased voltage 1[kV] AC 60[Hz] of impressed voltage, data is acquired a generating discharge for 10 seconds after impressing voltage. Also, as we repeated the experiment 10 times at same condition, analyzed foible using data except for maximum and minimum. As the result, we confirmed that discharge generating and discharge quantity were significantly increased narrowing radius of electrode, also discharge frequency was close to shape of a standard distribution.

  • PDF

Partial Discharge Characteristics of Silicone Rubber for Insulator by Impurities (불순물에 따른 애자용 실리콘고무의 부분방전특성)

  • Kim, T.Y.;Lee, H.J.;Shin, H.T.;Lee, C.H.;Lee, D.J.;Kim, W.K.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.506-509
    • /
    • 2003
  • In this paper, the $\Phi$-q-n pattern and average discharge power of silicone rubber have investigated effect of inter impurities. It's changed impurities by silicone oil, water and copper. Applied voltage is AC 3, 4, 4.5, 5, 5.5[kV]. And data acquisition time is 10 second(600 cycles). These results suggest that partial discharge(PD) is shower negative polar than positive polar at 3[kV]. Positive polar's PD value increased with increase of applied voltage. The Conductivities expressed same $\Phi$-q-n pattern in positive polar and negative polar at phase region.

  • PDF