• 제목/요약/키워드: $\Omega$ Type

검색결과 730건 처리시간 0.028초

Association between fish and shellfish, and omega-3 PUFAs intake and CVD risk factors in middle-aged female patients with type 2 diabetes

  • Kim, Hyesook;Park, Seokyung;Yang, Hyesu;Choi, Young Ju;Huh, Kap Bum;Chang, Namsoo
    • Nutrition Research and Practice
    • /
    • 제9권5호
    • /
    • pp.496-502
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: This study was performed to investigate the association between the dietary intake of fish and shellfish, and omega-3 polyunsaturated fatty acids (PUFAs) and cardiovascular disease (CVD) risk factors in the middle-aged Korean female patients with Type 2 diabetes (T2D). SUBJECTS/METHODS: A cross-sectional analysis was performed with 356 female patients (means age: 55.5 years), who were recruited from the Huh's Diabetes Clinic in Seoul, Korea between 2005 and 2011. The dietary intake was assessed by a validated semi-quantitative food frequency questionnaire and analyzed using the Computer Aided Nutritional Analysis program (CAN-Pro) version 4.0 software. RESULTS: In a multiple regression analysis after the adjustment for confounding factors such as age, BMI, duration of diagnosed T2D, alcohol consumption, fiber intake, sodium intake, and total energy intake, fish and shellfish intake of the subjects was negatively associated with triglyceride and pulse wave velocity (PWV). Omega-3 PUFAs intake was negatively associated with triglyceride, systolic blood pressures, diastolic blood pressures, and PWV. The multiple logistic regression analysis with the covariates showed a significant inverse relationship between the omega-3 PUFAs consumption and prevalence of hypertriglyceridemia [OR (95% CI) for greater than the median compared to less than the median: 0.395 (0.207-0.753)]. CONCLUSIONS: These results suggest that the consumption of fish and shellfish, good sources of omega-3 PUFAs, may reduce the risk factors for CVD in the middle-aged female patients with T2D.

Calcium Ions are Involved in Modulation of Melittin-induced Nociception in Rat: I. Effect of Voltage-gated Calcium Channel Antagonist

  • Shin, Hong-Kee;Lee, Kyung-Hee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제10권5호
    • /
    • pp.255-261
    • /
    • 2006
  • Melittin-induced nociceptive responses are mediated by selective activation of capsaicin-sensitive primary afferent fibers and are modulated by excitatory amino acid receptor, cyclooxygenase, protein kinase C and serotonin receptor. The present study was undertaken to investigate the peripheral and spinal actions of voltage-gated calcium channel antagonists on melittin-induced nociceptive responses. Changes in mechanical threshold and number of flinchings were measured after intraplantar (i.pl.) injection of melittin $(30\;{\mu}g/paw)$ into mid-plantar area of hindpaw. L-type calcium channel antagonists, verapamil [intrathecal (i.t.), 6 or $12\;{\mu}g$; i.pl.,100 & $200\;{\mu}g$; i.p., 10 or 30 mg], N-type calcium channel blocker, ${\omega}-conotoxin$ GVIA (i.t., 0.1 or $0.5\;{\mu}g$; i.pl., $5\;{\mu}g$) and P-type calcium channel antagonist, ${\omega}-agatoxin$ IVA (i.t., $0.5\;{\mu}g$; i.pl., $5\;{\mu}g$) were administered 20 min before or 60 min after i.pl. injection of melittin. Intraplantar pre-treatment and i.t. pre- or post-treatment of verapamil and ${\omega}-conotoxin$ GVIA dose-dependently attenuated the reduction of mechanical threshold, and melittin-induced flinchings were inhibited by i.pl. or i.t. pre-treatment of both antagonists. P-type calcium channel blocker, ${\omega}-agatoxin$ IVA, had significant inhibitory action on flinching behaviors, but had a limited effect on melittin-induced decrease in mechanical threshold. These experimental findings suggest that verapamil and ${\omega}-conotoxin$ GVIA can inhibit the development and maintenance of melittin-induced nociceptive responses.

PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구 (A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS)

  • 이장우;최충석
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.121-127
    • /
    • 2016
  • 본 논문에서는 대전류공급장치(PCITS)에 의해 소손된 강이음쇠형(iron fittings type) 금속플렉시블호스(CSST)의 구조 및 전기적 특성을 해석하였다. CSST는 보호 피막, 튜브, 너트, 클램프 링, 플레어 캡, 소켓, 볼 밸브 등으로 구성되어 있다. CSST의 내전압 평가는 전기 충전부와 비충전부 사이에 교류 전압 220 V를 1분간 인가하여 견뎌야 한다. 직류 500 V에 의한 절연 성능의 평가는 온도 상승 시험 전에 $1M{\Omega}$ 이상, 시험이 끝난 후에는 $0.3M{\Omega}$ 이상을 요구한다. 정상 제품의 평균 저항은 $11.5m{\Omega}$이었으나 PCITS로 130 A를 흘려 소손된 제품의 평균 저항 $11.50m{\Omega}$이었다. 또한 130 A가 약 10 s 흘렀을 때 튜브의 보호 피막이 일부 용융되었고, 검정색의 연기가 발생하였다. 60 s 경과되면 튜브의 대부분이 적색으로 발열되며, 전류가 120 s 흘렀을 때는 적열 범위가 넓어졌다. 95%의 신뢰 구간(CI)의 검증에서 P 값은 0.019로 정규 분포를 갖지 못하였으나 Anderson-Darling (AD) 통계량은 0.896, 표준 편차는 0.5573 등으로 양호한 특성을 나타냈다.

황동이음쇠형 금속플렉시블호스(CSST)의 저항 특성 및 소손 패턴 해석에 관한 연구 (A Study on the Analysis of the Resistance Characteristics and Damage Patterns of Brass Fittings Type CSST)

  • 이장우;최충석
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.67-73
    • /
    • 2016
  • 본 논문에서는 연소기에 사용되는 황동이음쇠형 CSST의 구조, 난연성 및 신뢰성 검증을 실시하였다. 황동이음쇠형 CSST는 보호 피막, 튜브, 너트, 클램프 링, 소켓, 볼 밸브 등으로 구성되어 있다. CSST의 적용 범위는 JIA가 4.2 kPa로 가장 높고, KS D 3625는 3.24 kPa이다. 정상 제품에 대한 신뢰 구간의 평균 저항은 $7.36m{\Omega}$으로 해석되었다. 난연성 실험이 완료된 후 신뢰 구간의 평균 저항은 $6.67m{\Omega}$이다. 정상 제품에 대한 AD는 1.584이며, 표준 편차는 0.3972로 해석되었다. 그리고 난연성 실험이 완료된 소손된 제품의 AD는 1.145이고, 표준 편차는 0.2467로 정상 제품에 비해 양호한 것으로 해석되었다. 또한 히스토그램 분석에서 정상 제품의 저항 평균은 $7.359m{\Omega}$이고, 표준 편차는 0.3972이었다. 그리고 난연성 실험이 완료된 후의 히스토그램의 저항 평균은 $6.67m{\Omega}$이며, 표준 편차는 0.2467이다.

Compact, Wavelength-selectable, Energy-ratio Variable Nd:YAG Laser at Mid-ultraviolet for Chemical Warfare Agent Detection

  • Kim, Jae-Ihn;Cho, Ki Ho;Lee, Jae-Hwan;Ha, Yeon-Chul
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.243-247
    • /
    • 2019
  • We have developed a compact, wavelength-selectable, Q-switched Nd:YAG laser at mid ultraviolet for chemical warfare agent detection. The fundamental wave at 1064 nm is delivered by a pulsed solid state laser incorporating with a square-type Nd:YAG rod in a resonator closed by two crossed Porro prisms for environmental reliability. The output energy at 213 nm ($5{\omega}$) and 266 nm ($4{\omega}$) by ${\chi}^{(2)}$ process in the sequentially disposed BBO crystals are measured to be 6.8 mJ and 15.1 mJ, respectively. The output wavelength is selected for $5{\omega}$ and $4{\omega}$ by a motorized wavelength switch. The energy ratio of the $5{\omega}$ to the $4{\omega}$ is varied from 0.05 to 0.85 by controlling the phase matching temperature of the nonlinear crystal for sum-frequency generation without change of the output pulse parameters.

$Ru^{+3}$, $Pt^{+4}$로 표면 처리한 GaSb의 결정 성장과 특성 (Study on the Crystal Growth and Characterization of GaSb treated with $Ru^{+3}$, $Pt^{+4}$)

  • 이재구;오장섭;송복식;정성훈;문동찬;김선태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.77-80
    • /
    • 1995
  • GaSb crystals were grown by the vertical Bridgman method. P-type GaSb crystals were grown with Ga:Sb=1:1 at % ratio without dopants and with Te, respectively. Also, GaSb:Te crystals were investigated. Lattice constants were 6.117${\AA}$ for p-type. The carrier concentration, the resistivity, and the carrier mobility measured by the van der Pauw method were p≡8 x $10^{16}$$cm^{-3}$, p≡0.20$\Omega$-cm, ${\mu}$$_{n}$$400\textrm{cm}^2$$V^{-1}$$sec^{-1}$ for p-type, n≡1 x $10^{17}$$cm^{-3}$, p≡0.15 $\Omega$-cm, ${\mu}$$_{n}$$500\textrm{cm}^2$$V^{-1}$$sec^{-1}$ for n-type at 300K. In case of treating with metal ion of $Ru^{+3}$, $Pt^{+1}$, p≡2 x $10^{17}$$cm^{-3}$, p≡0.08$\Omega$-cm, ${\mu}$$_{n}$≡420$\textrm{cm}^2$$V^{-1}$$sec^{-1}$ for p-type, n≡2.5 x $10^{17}$$cm^{-13}$, p≡0.07 $\Omega$-cm, ${\mu}$$_{n}$≡520$\textrm{cm}^2$$V^{-1}$$sec^{-1}$ for n-type were obtained.

  • PDF

절연링형 금속플렉시블호스(CSST)의 저항 특성 및 신뢰성 평가 (The Resistance Characteristics and Reliability Evaluation of an Insulation Ring Type of Corrugated Stainless Steel Tubing(CSST))

  • 이장우;김점식;최충석
    • 한국안전학회지
    • /
    • 제31권6호
    • /
    • pp.25-31
    • /
    • 2016
  • This paper has analyzed the structure, applicable regulations and the resistance characteristics of insulation ring type of CSST (Corrugated Stainless Steel Tubing for Gas). With the flammability test conducted in accordance with KS C IEC 60811-1-1, the evaluation of insulation resistance, temperature characteristics, and reliability has been conducted. An insulation ring type CSST consists of protective coating, tube, nut, insulation ring, packing, socket, and ball valve. Connecting an insulation ring type CSST to gas tubings for gas appliance is not permitted, moreover, the product shall be installed inside a sleeve pipe in case of buried installation such as the ceiling. Damages on protective coating and tube were detected when fire was applied to the test sample with a portable torch for 60 seconds. The insulation resistance of a normal product was $49.59M{\Omega}$, while that of the product completed the flammability test reduced to $9.21M{\Omega}$. The mean insulation resistance within the confidence Interval of 95% using the mini tap program 17 was $49.59M{\Omega}$ and the mean insulation resistance within the confidence interval reduced to $9.21M{\Omega}$. In the normal distribution analysis of 95% confidence interval, the value-P of the normal product was stable at 0.075 and AD(Anderson-Darling) statistic value was turned out to be 0.063, which is very normal, and the standard deviation was analyzed as 0.2586. The value P of the product completed the flammability test resulted in 0.005, the AD was 1.355 and the standard deviation reduced to 0.07908.

Current-Mode Electronically Tunable Universal Filter Using Only Plus-Type Current Controlled Conveyors and Grounded Capacitors

  • Minaei, Shahram;Turkoz, Sait
    • ETRI Journal
    • /
    • 제26권4호
    • /
    • pp.292-296
    • /
    • 2004
  • In this paper we present a new current-mode electronically tunable universal filter using only plus-type current controlled conveyors (CCCII+s) and grounded capacitors. The proposed circuit can simultaneously realize lowpass, bandpass, and highpass filter functions - all at high impedance outputs. The realization of a notch response does not require additional active elements. The circuit enjoys an independent current control of parameters $\omega_0$ and $\omega_0/Q$. No element matching conditions are imposed. Both its active and passive sensitivities are low.

  • PDF