• Title/Summary/Keyword: $+1.0{\times}$ Magnification

Search Result 89, Processing Time 0.025 seconds

Light-emitting diode assessment of dentinal defects: the role of presumed extraction forces

  • Coelho, Marcelo Santos;Card, Steven J.;Tawil, Peter Z.
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.232-239
    • /
    • 2017
  • Objectives: The evaluation of iatrogenic dentinal defects in extracted teeth may be influenced by extraction forces and prolonged dry times. The purpose of this study was to compare the presence of dentinal defects in freshly extracted, periodontally compromised teeth with those in a group of teeth with uncontrolled extraction forces and storage time. Materials and Methods: The experimental group consisted of eighteen roots obtained from teeth extracted due to periodontal reasons with class II or III mobility. They were kept in saline and sectioned within 1 hour following extraction. The control group consisted of matched root types obtained from an anonymous tooth collection, consistent with previous dentinal defect studies. The slices were obtained at 3, 6, and 9 mm from the apex. The imaging process exposed all specimens to no more than 60 seconds of dry time. The ${\times}12.8$ magnification was used for the 9 mm slices and ${\times}19.2$ magnification for the 3 mm and 6 mm slices under light-emitting diode (LED) transillumination. The root canal spaces and periodontal tissues were masked to minimize extraneous factors that might influence the evaluators. Chi-square test was used for statistical analysis. Results: Dentinal defects were detected in 17% of the experimental group teeth, compared to 61% of control teeth (p = 0.015). Conclusions: LED transillumination assessment of freshly extracted roots with class II or III mobility showed smaller number of dentinal defects than roots with uncontrolled storage time and extraction forces. The use of freshly extracted roots with mobility should be considered for future dental defect assessment studies.

Comparison of the marginal fit of POM restorations with different thickness of metal copings (코핑 두께의 차이에 따른 POM 보철물의 변연적합도 연구)

  • Lim, Hyung-Tek
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.135-143
    • /
    • 2012
  • Purpose: The purpose of this in vitro study was to compare the marginal fit of POM restorations with 3 different thickness of metal coping. Methods: 2.0mm Occlusal reduction, 1.0mm preparation of axial wall with 6degree taper, and chamfer margin was prepared a maxillary first premolar on dentiform. Duplicate prepared die and, make 30 individual dies with Ni-Cr metal. Make 3 groups of 30 press ceramic on Metal crown with different thickness of metal coping; 10 of 0.1mm, 10 of 0.3mm, 10 of 0.5mm thickness metal coping. The marginal fit of the crowns was evaluated 50 points per 1 crown, around the crown margin circumference under a optical microscope at original magnification ${\times}100$. A 1-way analysis of variance (ANOVA) was used to compare data. Results: The mean marginal discrepancy for POM with 0.1mm metal copings was $72.56{\mu}m$, $67.83{\mu}m$ for 0.3mm metal coping POMs, and $72.56{\mu}m$ for 0.5mm metal coping POM. The 1-way ANOVA showed significant difference among 3 groups. Conclusion: The marginal fit of pressed-on-metal (POMs) was best with 0.3mm thickness of metal coping, fallowing by 0.1mm, and 0.5mm in the order.

Effects of Caponization on Bone Characteristics and Histological Structure in Chickens

  • Chen, Kuo-Lung;Chang, Ming-Huang;Tsay, Shiow-Min;Hurng, Huaang-Youh;Chiou, Peter Wen-Shyg
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.2
    • /
    • pp.245-251
    • /
    • 2006
  • The aim of this study was to investigate the effects of caponization on the bone characteristics, biomechanical property and histology in Taiwan country chickens fed to market age of 26 wks. Male Taiwan country chickens $D{\times}L_2$ were caponized or sham-operated at 8 wks of age, and selected healthy sham-operated and completely caponized chickens (prominent degenerated comb) were selected at 16 wks old and fed to 26 wks old for the trials. Fifteen intact male chickens (Intact), sham-operated chickens (Sham) and caponized chickens (Capon) were assigned for trial 1, and sixteen Intact and Capon were assigned for trial 2. Results in trial 1 showed that the abdominal fat and relative abdominal fat weights of Capon were significantly heavier than Intact and Sham (p<0.05), while the tibia weight and relative weight were the lightest (p<0.05). The tibia breaking strength, bending moment and stress of Capon were the poorest among groups (p<0.05). The trial 2 produced the similar observation that Capon were significantly lighter than Intact (p<0.05) in the tibia weight, relative tibia weight and their biomechanical properties. On histological determinations, Capon showed a thinner cartilage end and fewer chondrocytes (about 50%) and trabecular, and bigger marrow cavity; while decreased hemopoietic cells number with increased adipocytes than Intact observed by H&E stain and at low magnification. At high magnification, Capon showed a decrease in the chondrocyte size by 33 to 50%, with smaller nucleus located near the cell membrane, and exhibited monocellular form chondrocytes. Capon also showed a less strongly acidic sulfated mucosubstance with weaker dyeing property within cartilage zone, and smaller chondrocytes size by Alcian blue stain.

Development on a Roofed Pechan Prism Type Scope with Long Eye Relief (긴 안점거리를 갖는 지붕형 페찬 프리즘 타입 스코프 개발)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.247-255
    • /
    • 2010
  • Purpose: Developing a roofed Pechan prism type scope with long eye relief. Methods: To reduce the overall length and to lengthen the eye relief of scope, the objective part was designed by adopting the roofed Pechan prism and also the eyepiece part was designed by adopting the field lens with minus refractive power in front of reticle, respectively. Finally, by integrating above two parts, the roofed Pechan prism type scope with 90 mm eye relief was developed. Results: The characteristics of the developed and fabricated scope with 90 mm eye relief by integrating the objective part with the roofed Pechan prism and the eyepiece part with minus refractive power had the magnification of $+3.0{\times}$, the length from the 1st lens to the last lens of about 121 mm, the barrel diameter of 28 mm, and the effective objective-diameter of 17 mm. Also it was found that the line width of resolution was about 900 cycles/rad at the 50% MTF value criterion. Conclusions: We could design and manufacture the roofed Pechan prism type scope with 90 mm eye relief, the characteristics of which had the magnification of $3.0{\times}$, the MTF above 50% at 900 cycles/rad, and the length from the 1st lens to the last lens of about 121 mm.

Serological Detection of Plant Viruses with latex-test (Latex-Test에 의한 식물 바이러스의 검정)

  • 박은경;김정화;이영근
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.1 no.1
    • /
    • pp.33-38
    • /
    • 1979
  • A simple test using latex-agglutination was developed to detect serologically tobacco mosaic virus (TMV), soybean mosaic virus (SoyMV), and barley stripe mosaic virus (BSMV) from infected Plants. Latex spheres ( 0.81 $\mu$, Difco) were adsorbed with immuno globulin purified by electrophoresis from crude antiserum against viruses. The antibody- sensitized latex suspension was mixed with sap from virus -infected leaves in a glass capillary tube (inner diam. 1mm $\times$ 100 mm length) The mixture, after agitation, was observed under a stereo microscope at low magnification (X20 - X4O), to examine the reaction between antigen (Virus) and its antibody. Flocculation occurred when the reaction was positive.

  • PDF

Deep UV 마이크로 리소그라피를 위한 새로운 4-반사경 광학계에 관한 수차해석

  • 김종태;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1993
  • A design of four-mirror optical system with reduction magnification 5X for deep UV ($\lambda$=248 nm of KrF excimer laser) submicron lithography is presented. Initially by using the paraxial quantities, the domain of solution for $t=d_1+d_2+d_3$<0 (d;: distance between the mirror $c_i$ and $c_{i+1}$ is found for the system which is free from the four off-axial Seidel first order aberrations that are coma, astigmatism, field curvature, and distortion. The solution with $d_5$=2.95 (normalized with respect to $c_i$= -1) is choosen and the aspherization is carried out to the spherical mirror surfaces ($c_3$ and $c_4$ in order to reduce the axial and residual off-axial higher order aberrations. The numerical aperture of the final system is as large as 0.4, which gives Rayleigh resolution of 0.38 $\mu\textrm{m}$.

  • PDF

Development of the Imaging Optical System for the 545 nm Fluorescent Plate of X-ray (X선용 545 nm 형광판 결상광학계 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • To develop an imaging optical system for the 545 nm fluorescent plate of X-ray. Methods: We designed and manufactured a new imaging optical system for the 545 nm fluorescent plate of X-ray by Sigma 2000 program after deciding the design comparison standards referred to Canon CX2-70 model. Results: The characteristics of the new imaging optical system for the 545 nm fluorescent plate of X-ray have the magnification of -0.225x, the image field size of $90mm{\times}90mm$, and the 0.033 mm resolution line width at the 30% MTF value criterion. These mean that the new model has a capability of deciphering for the more large screen and the resolution of deciphering is superior to that of Canon CX2-70 model. Also the image side NA (-0.196) of the new model is about $\sqrt{2}$ times than that (-0.139) of CX2-70 and the object side NA (0.044) of the new model is about 2 times than that (0.022) of CX2-70. These mean that the sensitivity of the film in the new design model is able to be increased to about 4 times and there is the possibility of reducing the bombed time of X-ray to 1/4 times. Conclusions: We could design and manufacture the imaging optical system for the 545 nm fluorescent plate of X-ray having the possibility of reducing the bombed time of X-ray to 1/4 times in comparision to Canon CX2-70 model, the characteristics of which have the image field size of $90mm{\times}90mm$ and the MTF of 30% or more at 15 lines/mm criterion.

  • PDF

THE EFFECT OF OBTURATION TECHNIQUES ON THE APICAL MICROLEAKAGE OF ROOT CANALS (근관충전방법에 따른 치근단부 근관의 미세누출에 관한 연구)

  • Yoo, Hyung-Jun;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.213-222
    • /
    • 1998
  • Advisor: Prof. The quality of apical seal obtained with 3 different gutta-percha obturation techniques was compared in 49 recently extracted single rooted teeth. The root canals were instrumented using step-back technique and obturated with laterally condensed gutta-percha, Continuous Wave gutta-percha, and hybrid technique. Teeth were suspended in black India ink for 7 days, cleared, and then examined under a stereomicroscope at ${\times}10$ magnification. The results were as follows; 1. All experimental groups produced favorable apical seal. 2. The mean leakage was $0.23{\pm}0.25mm$ for group 1, $0.17{\pm}0.21mm$ for group 2, and $0.19{\pm}0.23mm$ for froup 3, but there was no statistical difference amoung them. Within the limits of the results of this experiment, the Continuous Wave gutta-percha obturation technique demonstrated relatively favorable apical sealing effect and shorter obturation time. Thus, it is thought that this obturation technique is a acceptable method for clinical use but further studies on this metter should be conducted.

  • PDF

Improvement of Preservation Quality of Chilled Bull Semen Using ${\alpha}$-tocopherol as an Antioxidant

  • Jha, Pankaj Kumar;Paul, Ashit Kumar;Rahman, M. Bozlur;Tanjim, M.;Bari, Farida Yeasmin;Alam, M. Golam Shahi
    • Journal of Embryo Transfer
    • /
    • v.28 no.1
    • /
    • pp.31-39
    • /
    • 2013
  • Alpha-tocopherol as an antioxidant acts in preservation of chilled semen by preserving cell membrane damage from lipid peroxidation. Optimum concentrations of ${\alpha}$-tocopherol in egg yolk-citrate (EYC) extender need to be studied in crossbred bull's semen. Different concentrations of ${\alpha}$-tocopherol viz. 0, 1, 2, 4 and 6mg per ml of extender were used. Semen was collected once a week from four bulls used to regular collection, aged 4 to 7 years, weighing 320 to 450 kg, and with body condition score 4 to 4.5 and scrotal circumference 23 to 32 cm. Semen was evaluated routinely and sperm morphology was viewed under light microscope at ${\times}1,000$ magnification after fixing with buffered formal saline. Over 90% had normal head, acrosome, mid-piece and tail. Semen was diluted with egg-yolk-citrate extender to produce $15{\times}10^6$ spermatozoa/ml and 0, 1, 2, 4 and 6 mg/ml ${\alpha}$-tocopherol were added. The semens amples were kept at $8^{\circ}C$. Sperm motility and viability were examined daily up to 5 days under light microscopy at ${\times}200$ magnification. Sperm viability was acceptable (${\geq}40%$) up to the $4^{th}$ day with all concentrations of ${\alpha}$-tocopherol and up to the $5^{th}$ day with 2 mg/ml ${\alpha}$-tocopherol. Sperm motility was acceptable (${\geq}40%$) up to the $3^{rd}$ day irrespective of ${\alpha}$-tocopherol concentration, and up to the $4^{th}$ day with 2 mg/ml ${\alpha}$-tocopherol. It is suggested that the lifespan of chilled semen may be extended up to 4 days by adding 2mg/ml ${\alpha}$-tocopherol.

Thermal imaging sensor design using 320×240 IRFPA (320×240 적외선 검출기를 이용한 열상센서의 설계)

  • Hong Seok Min;Song In Seob;Kim Chang Woo;Yu Wee Kyung;Kim Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.423-428
    • /
    • 2004
  • The development of a compact and high performance MWIR thermal imaging sensor based on the SOFRADIR 320${\times}$240 element IRCCD detector is described. The sensor has 20 magnification zoom optics with the maximum 40$^{\circ}$${\times}$30$^{\circ}$ of super wide field of view and 7.6 cycles/mrad of resolving power with the operation of attached micro-scanning system. In order to correct nonuniformities of detector arrays, we have proposed a multi-point correction method using defocusing of the optics and we have acquired the highest quality images. The MRTD of our system shows good results below 0.05K at spatial frequency 1 cycles/mrad at narrow field of view. Experimental data and obtained performances are presented and discussed.