Abstract
Purpose: The purpose of this in vitro study was to compare the marginal fit of POM restorations with 3 different thickness of metal coping. Methods: 2.0mm Occlusal reduction, 1.0mm preparation of axial wall with 6degree taper, and chamfer margin was prepared a maxillary first premolar on dentiform. Duplicate prepared die and, make 30 individual dies with Ni-Cr metal. Make 3 groups of 30 press ceramic on Metal crown with different thickness of metal coping; 10 of 0.1mm, 10 of 0.3mm, 10 of 0.5mm thickness metal coping. The marginal fit of the crowns was evaluated 50 points per 1 crown, around the crown margin circumference under a optical microscope at original magnification ${\times}100$. A 1-way analysis of variance (ANOVA) was used to compare data. Results: The mean marginal discrepancy for POM with 0.1mm metal copings was $72.56{\mu}m$, $67.83{\mu}m$ for 0.3mm metal coping POMs, and $72.56{\mu}m$ for 0.5mm metal coping POM. The 1-way ANOVA showed significant difference among 3 groups. Conclusion: The marginal fit of pressed-on-metal (POMs) was best with 0.3mm thickness of metal coping, fallowing by 0.1mm, and 0.5mm in the order.
Keywords
POM; lucite glass ceramic; marginal fit;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 김윤영, 박원희, 유동엽, 이영수. 열-가압을 이용한 금속 도재관과 전통적인 금속 도재관의 변연 적합도 비교연구. 대한치과보철학회지, 48(4), 273-279, 2010.
2 American Dental Association, ANSI/ADA Specification No. 8 for zinc phosphate cement. In Guide to Dental Materials and Devices (ed 5). Chicago, IL: American Dental Association, 87-88, 1970-1971.
3 Bjorn AL, Bjorn H, Grkovic B. Marginal fit of restorations and its relation to perioddental bone level. Part II. Crowns. Odontol Revy. 21, 337-346, 1970.
4 Carter JM, Sorensen SE, Johnson RR, Teitelbaum RL, Levine MS. Punch shear testing of extracted vital and endodontically treated teeth. J Biomech. 16, 841-848, 1983.   DOI   ScienceOn
5 Gassino G, Barone Monfin S, Scanu M, Spina G, Preti G. Marginal adaptation of fixed prosthodontics: a new in vitro 360-degree external examination procedure. Int J Prosthodont. 17, 218-223, 2004.
6 Gemalmaz D, Alkumru HN. Marginal fit changes during porcelain firing cycles. J Prosthet Dent. 73, 49-54, 1995.   DOI   ScienceOn
7 Groten M, Axmann D, Poster L, Weber H. Determination of the minimum number of marginal gap measurement required for practical in vitro testing. J Prosthet Dent. 83, 40-49, 2000.   DOI   ScienceOn
8 Mclean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 131, 107-111, 1971.   DOI   ScienceOn
9 Pera P, Bassi F, Carossa S. In vitro marginal adaptation of alumina porcelain ceramic crown. J Prosthet Dent. 72, 585-590, 1994.   DOI   ScienceOn
10 Shillingburg HT, Hobo S, Fisher DW. Preperation design and marginal distortion in porcelain-fused- to-metal restorations. Prosthet Dent, 29, 276-84, 1973.   DOI   ScienceOn
11 Sorensen JA. A standardized method for determination of crown margin fidelity. J Prosthet Dent, 64, 18-24, 1990.   DOI   ScienceOn
12 Waerhaug J. Tissue reactions around artificial crowns. J periodontal, 24, 172-185, 1963.
13 White SN, Kipnis V. Effect of adhesive luting agents on the marginal seating of cast restorations. J Prosthet Dent, 69, 28-31, 1993.   DOI   ScienceOn
14 Wu JC, Wilson PR. Optimal cement space of resin luting cement. Int J Prosthodont, 7, 209-215, 1994.